`/option/autoclean/vs/0` carries three fields and only `settingStatus` was read.
That one says the feature is enabled, which it is whether or not the unit is
drying right now, so nothing reported an actual cycle.
settingStatus: On <- the existing auto_clean switch
status: Stop supportedStatus: [Start, Stop]
progress: 0
Adds a binary sensor for `status` and a percentage sensor for `progress`.
Measured on a TP1X_DA-AC-CAC-01001, sampling the resource every eight seconds
across a cycle: `Start` with progress 98 while it ran, then `Stop` with progress 0
the moment it finished. The percentage matches the figure the appliance shows on
its own display, checked against 55% mid-run.
Golden state keys updated for the 18 fixtures that bind AUTO_CLEAN. The change is
additive — no key was removed from any of them.
Full suite passes (1070 tests, Python 3.13 via requirements-dev.txt).
- airconditioner.py: odor_controller_active binary_sensor + odor_controller_progress
sensor, read from the /mode/vs/0 SmartCoolClean_/ProgressSmartClean_ option tokens
(SmartThings cloud custom.airConditionerOdorController capability). Read-only --
no confirmed write command.
- Reporter's TP1X_DA-AC-RAC-01001_0000 dump: fan speed and WindFree preset already
bind via the existing composite climate entity, no code change needed there.
- en.json/nl.json: new entity names for the two additions.
- cs.json: new, full Czech translation catalog (mirrors en.json topology 1:1).
- New fixture + golden + tests locking in the odor-controller behavior.