Marc Billow 6033709f24 Replace the blanket "cannot connect" with a real failure taxonomy
Adding a device had one message for nearly every way it could fail: "Cannot
connect to the device. Verify the IP address is reachable and the CA
credentials are correct." That covers an IP with nothing on it, an
appliance on cloud-only firmware, a device still holding the session from
the last attempt, a device that answered and rejected our certificate, and
Home Assistant having no internet to reach Samsung's cloud. Only one of
those is fixed by checking the IP and the CA credentials, and the message
gave no way to tell which one you had.

The probe already gathers enough to tell them apart, so classify it:

- cert_rejected     the appliance sent a certificate alert. The CA
                    credentials aren't the AC14K_M CA it trusts, or they
                    don't pair. Far and away the most common real setup
                    mistake, and previously indistinguishable from a typo
                    in the IP address.
- handshake_failed  a fatal alert unrelated to the certificate (protocol or
                    cipher mismatch) -- no amount of fiddling with CA
                    credentials will fix it.
- handshake_timeout the ClientHello probe proved a DTLS server is right
                    there, but the handshake never finished. Usually the
                    appliance is still holding the association from a
                    previous attempt; it clears on its own in about a
                    minute.
- ports_closed      ICMP port-unreachable on the whole range: something is
                    at that address and it isn't exposing a local API.
                    Cloud-only firmware (TCP 8888 only) lands here.
- no_dtls_server    some ports open|filtered, none speaking DTLS -- likely
                    another device on that IP.
- no_response       nothing came back at all.
- cloud_unreachable couldn't reach Samsung's cloud gateway for the UUID.
                    An internet problem on HA's side, not the appliance's.
- unexpected_response  authenticated fine, then returned something we can't
                    read. Neither connectivity nor credentials.

Certificate alerts are read back out of the error text OpenSSL puts in
DtlsCoapSession's ConnectionError, not by re-probing. The library's
diagnostic probe would report the alert authoritatively, but it drives the
handshake far enough to commit association state on the device -- and an
orphaned association is exactly what makes the *next* attempt time out
(RFC 6347 4.2.8), which is a bad trade on a path the user is about to
retry.

Telling ports_closed from no_response needs the UDP sweep to separate a
refusal from an unreachable. Both leave a port "not live", but ECONNREFUSED
is a *response* -- the host is there -- while EHOSTUNREACH/ENETUNREACH mean
the datagram never left. A wrong IP on the local subnet never answers ARP
and fails every send that way, so treating the two alike would have told
those users their appliance was on cloud-only firmware. The sweep now
returns live/refused/unreachable separately, and the preferred-port rescue
moved out of it into _sweep_ports: the rescue is a candidate-selection
decision, and folding it into the sweep's verdict destroyed the evidence
the message is built from.

Every failure carries the error key that fits it, so the flow maps
exceptions instead of guessing, and logs the specifics (alert name, per-port
outcome, response code) at warning level -- the messages that mention the
log now have something to point at.

Certificate re-minting for a reused leaf is also narrower and more correct
as a result: it now triggers on CertRejected specifically, rather than on
"every attempt raised ConnectionError and a port was confirmed".

All five translation catalogs carry the eight new messages. The non-English
ones are my own work rather than a native speaker's; corrections welcome.
2026-08-03 20:29:53 +00:00
Marc Billow 15be379243 Rebuild device discovery on the ClientHello probe and resolve identity up front
Two problems, one setup path.

Port detection (issue #211): the config flow found the DTLS port by
elimination -- a 1-byte UDP probe can't tell a silent port from a real
DTLS server, so every port it couldn't rule out got a full certificate
handshake, and every false positive cost the whole 12s HANDSHAKE_TIMEOUT_S
before the next was tried. Adding an appliance took 30-40s.

smartthings-local 0.1.2 ships a stateless ClientHello probe that settles
this positively: a real DTLS server answers with a HelloVerifyRequest in
~1 RTT, and per RFC 6347 4.2.1 it does so without allocating association
state, so the probe leaves nothing behind on the appliance. The whole
49152-49160 range is probed at once and exactly one confirmed port is
given a certificate handshake. Fanning out is safe here in a way racing
real handshakes is not -- each probe is bounded by a 3s budget, so the
pool costs one probe's wall clock rather than the sum of the range, with
no losing threads left running behind us.

The UDP sweep stays as the fallback for when the probe confirms nothing:
it errs in the opposite direction (it reports everything it can't rule
out), so it still surfaces a device on a path that eats our ClientHello,
and it keeps its issue #192 preferred-port rescue.

Port detection now runs first and needs no credentials, so an unreachable
host fails before any round trip to Samsung's cloud. And a second
appliance reuses the existing entry's leaf cert rather than re-minting --
every device accepts the same one -- which makes adding one independent
of Samsung-cloud reachability. A confirmed-live device rejecting the
reused leaf (the UUID does rotate) re-mints and retries once, so reuse
stays self-correcting; a timeout doesn't, since a fresh cert can't fix
nothing answering.

Identity (issue #236): the coordinator seeded device_serial with the
configured host and only replaced it after the first successful poll. But
device_serial mints *permanent* registry keys -- entity unique_ids and
device identifiers -- so anything registering before that poll returned
was written into the registry keyed on the IP address forever. The
connection-mode sensor is added unconditionally rather than from `bound`,
so it was the reliable victim: when the serial-keyed identity appeared
moments later HA created a second device and entity, and the IP-keyed
pair was orphaned. Deleting them didn't help; the next restart that lost
the race recreated them.

The probe already learns the identity, so store it on the config entry --
serial, model, manufacturer, device type. The coordinator seeds
device_serial and its DeviceInfo from those at construction, so keys are
correct from the first entity that registers even if the first poll is
slow or fails outright. There is no placeholder left to correct.

Discovery now treats the registered identity as authoritative rather than
re-keying a device that already has registry entries; it adopts and
persists the polled identity only for an entry that has none, and warns
if a different appliance answers on the same IP.

Entry version 1 -> 2 recovers the serial from the entry's unique_id (the
flow has always keyed it on the probe's serial) and repairs what the old
registration orphaned: IP-keyed devices and entities are rewritten in
place where the serial-keyed key is free -- keeping entity_id, name, area
and every automation referencing them -- and removed where both exist,
since the IP-keyed one has been dead since the restart that made it.
Placeholder-serial boards (issues #83/#189) were keyed two ways at once,
`host:port` on the entry and `host` in the registry; migration collapses
the entry onto the registry's form. One resolve_serial() now serves both
sides, so they can't drift apart again.

The remaining step in the desired pipeline -- probe for subdevices, then
register devices, then populate entities -- already holds:
_enumerate_subdevices_blocking runs before _run_discovery, which runs
before platforms are forwarded. Duplicating it in the config flow would
mean re-running Pattern B's per-href fallback probe, which is the
opposite of what issue #211 is about.
2026-08-03 20:14:54 +00:00
Marc Billow 679c3d2bce Fix remaining pre-existing ty diagnostics in test files
Completes the isinstance/cast narrowing + Optional-field assert pattern
across the last batch of test files. custom_components and tests are
now both fully clean under ruff check, ruff format --check, and ty check.
2026-08-03 00:14:58 +00:00
Marc Billow 36a642135b Fix pre-existing ty diagnostics in a second batch of test files
Same isinstance/cast narrowing and Optional-field assert pattern as the
prior commits, covering the airconditioner, fridge, washer, operational,
subdevices, sensor_hysteresis, laundry, select_options, identity and
entities test files.
2026-08-03 00:11:05 +00:00
Marc Billow daf7e3787f Add ruff (lint + format) and ty (type checking) to the project
Adds [tool.ruff] and [tool.ty] config to pyproject.toml with a curated
ruff rule set (E, F, W, I, UP, B, C4, SIM, RUF, ASYNC, LOG, G, PIE, RET,
PERF, N), pins ruff/ty in requirements-dev.txt, reformats the whole tree
with `ruff format`, and fixes the pre-existing lint and type-check debt
those tools surfaced so both run clean.

Production-code type fixes include: HA's ConfigFlowResult vs. the
generic FlowResult in config_flow.py, narrowing BoundEntity.desc to its
platform-specific subclass (SelectDesc/NumberDesc/SensorDesc/etc.) via
cast() instead of an unchecked annotation, converting HA device_class
strings to their proper enum types, a resolve_registry callback typed
as `object` instead of `DeviceRegistry | None`, and a couple of other
narrow correctness fixes (CA key type validation, an index-out-of-bounds
false positive from an empty-tuple fallback, a bool/dict argument swap).

Test-file fixes are mechanical: narrowing SamsungEntityDescription to
the correct subclass via isinstance()/cast() before accessing
subclass-only fields, and asserting Optional write_fn/unit_fn fields
are set before calling them.
2026-08-02 23:56:38 +00:00
Marc Billow e642db462d fix: recognize all-same-hex-digit placeholder serials (#189)
_is_placeholder_serial only caught the ARTIK051_DONGLE_REF family's
'Nothing(SVC)' sentinel. The DA_WM_A51_20_COMMON (ARTIK051) laundry
board family reports a different one instead -- every character the
same repeated hex digit -- which passed through as a real, non-unique
serial. Two different physical units (a washer and a dryer) both
reporting the literal serialNum 'FFFFFFFFFFFFFFF' collided on the
config-entry unique_id, so the second device's config flow aborted as
already configured. Widen the check (both the config_flow.py and
coordinator.py copies) to also catch that sentinel shape.
2026-07-31 01:59:49 +00:00
Marc Billow bd3ca80d3c review: address Opus code-review findings on this branch
- config_flow: the #192 port-rescue made the "every port refused" fast-fail
  permanently unreachable (PREFERRED_PROBE_PORTS is always non-empty and
  always rescued), so removed the dead branch instead of leaving it as
  misleading dead code. A dead host now fails via the handshake loop's own
  error, which carries the real per-port reason.
- oven._has_option: added the is_stub_rep carve-out cooktop.py's identical
  per-token exists_fn already has on the same kind of href, so a not-yet
  sub-polled /mode/vs/0 doesn't permanently exclude energy_saving/
  cooktop_on_alert before their first real fetch lands.
- airconditioner.ENERGY_METER_LEGACY: build via dataclasses.replace() like
  its ENERGY_METER_GENERIC sibling, instead of hand-copying href/poll_tier
  (which would silently drift if common.ENERGY_METER ever gains a field).
- Fixed two stale comments: is_legacy_board()'s docstring still listed
  Volume among tokens needing legacy-only gating, though 'beep' now applies
  unconditionally across board generations; and common.py's UNIVERSAL
  invariant comment didn't mention that airconditioner also now excludes
  ENERGY_METER from the wholesale bundle.
- #191 (CAC token): added the fixture/golden/capability-test coverage the
  AVT token in the same branch got, including an honestly-documented list
  of the ten hrefs this board generation doesn't cover yet.
- fridge.cooler_temperature_setpoint: dropped the hardcoded "N °C" state
  labels -- the resource's own unit field isn't necessarily Celsius on a
  different model reporting the same href, and the options themselves are
  already read live via options_field, so a static per-value label risked
  asserting the wrong unit for a future device sharing this capability.
- airconditioner._legacy_cumulative_power_kwh: parse with float (matching
  common.wh_to_kwh's own numeric parsing) instead of this module's
  integer-only _int, so a decimal-formatted reading doesn't raise.
- test_config_flow: the port-rescue test bound the real 49154 directly,
  which could collide with an actually-running service on some machine;
  now monkeypatches PREFERRED_PROBE_PORTS to an OS-assigned port instead.
- oven.py: consolidated six byte-for-byte-identical single-token options
  write_fns (lamp/sound/fast_preheat/natural_steam/energy_saving/
  cooktop_on_alert) into one _option_switch_write(prefix) factory.

845 tests passing (up from 841 -- 4 new CAC coverage tests).
2026-07-29 18:04:23 +00:00
Marc Billow e8df8f7b0c fix(config_flow): always retry historically-confirmed DTLS ports (#192)
The liveness sweep's ICMP-based verdict isn't trustworthy on every network
path -- a segregated-VLAN report showed it calling three closed ports live
while missing the one port a concurrent nmap scan found genuinely
open|filtered, which also happened to be one of our two historically
confirmed DTLS ports. Rather than trust a "not live" verdict against that
prior, always give PREFERRED_PROBE_PORTS a real handshake attempt even when
the sweep excludes them, bounded to at most those two extra attempts.

This is a stop-gap for the reported failure mode, not a full fix for the
sweep's underlying unreliability -- left a comment on the issue with the
diagnosis and flagged the sweep itself for a deeper redesign.
2026-07-29 12:53:56 +00:00
Marc Billow cafd7d5afa refactor(registry): drop oneUiVersion from device-type detection
oneUiVersion looks like the signal you'd want -- the device naming its own
type, '7.0 Dishwasher' -- and it was the first thing detection consulted. It
never earned the position:

- Only 7 of 49 fixtures report it at all.
- All 7 resolve to the same registry from their modelNum board token alone.
- No device-support issue has ever been fixed by adding a mapping for it.
  Every one went through modelNum. The alias keys it needed in
  _REGISTRY_BY_KEY ('airpurifier', 'air_conditioner', 'hood') were
  speculative when the registries were first written and never used since.

So it bought a key-normalizing helper (_type_key), a lookup with a suffix
fallback (for_device), three alias keys, and a second config-flow step whose
only reason to exist was phrasing a sentence about oneUiVersion -- for a
signal that has never once been decisive.

Remove it from detection. It stays in diagnostics, where it's genuinely
useful: it names the firmware generation ('7.0 Air conditioner' is Tizen
Lite), which matters when triaging an issue.

Detection order was also duplicated in four places -- the coordinator, the
config flow's probe, the golden-regression harness, and the skill -- which
is how the harness and the shipped order drift apart. Collapse it into
by_type.resolve(resources), and call that everywhere.

The two "appliance type not recognized" config steps become one. They
differed only in whether they blamed a missing oneUiVersion, which is not a
distinction a user can act on, and never was.

Verified by the full suite (795 passing), including every golden regression
-- so entity output is byte-identical for all 49 device fixtures.

TestOneUiVersionIsNotConsulted locks in the premise rather than just the
outcome: for every dump that reports a oneUiVersion, the model strings alone
must still reach a registry. If a future device breaks that, the test says
so instead of the device silently losing half its entities.

Also note in requirements-dev.txt that Python 3.13 resolves the pinned
harness floor -- 3.12 and older resolve nothing and fail the whole install.
2026-07-29 02:14:13 +00:00
Marc Billow 2c9fda3db1 Catch the 'Nothing(SVC)' placeholder serial in both fallback sites (issue #83)
The ARTIK051_DONGLE_REF firmware family reports the literal string
"Nothing(SVC)" as serialNum on every unit -- non-empty, so the existing
`if not serial` checks in config_flow.py's _probe_and_validate and
coordinator.py's _run_discovery don't catch it. Two such appliances on
one install (a fridge and a freezer, each its own dongle) then collide:
config_flow gives both the same unique_id and rejects the second as
"already configured" (bug 2), and even once that's worked around,
device_serial feeds every entity's unique_id too, so the second
appliance's entities get silently dropped with "does not generate
unique IDs" log lines (bug 4).

Add _is_placeholder_serial (duplicated in both modules rather than
imported, to avoid pulling config_flow into the runtime coordinator's
import graph or vice versa for a two-line check) and treat it the same
as an empty serial: fall back to host/port.

Type detection (bug 1) and the door sensor's field-name gap (bug 3),
also reported in this issue, are already fixed via the
claude/device-support-issue-77-freezer branch, which hit the same
ARTIK051_DONGLE_REF family from a different report -- not duplicated
here.
2026-07-27 01:00:05 +00:00
Hmmbob b85af10ae1 Test translation coverage and dynamic fallbacks 2026-07-24 18:08:29 +02:00
Marc Billow c731ecefe5 feat: add debug options panel for arbitrary resource-href writes (#54)
Power users can now pick a resource href from a live dropdown, view its
current value, and POST a minimal patch straight to the device -- to pin
down device-specific write behavior without waiting on a new release.
Bypasses the remote-control block and all write_fn/validate_fn logic by
design; the existing remote-control settings toggle moves behind the same
options-flow menu.
2026-07-24 14:02:15 +00:00
Marc Billow 037dc9722f feat: add options flow to bypass the remote-control write block per device (issue #54)
The remote-control-off write block was device-wide and unconditional:
whenever a device reports remote control off, every write is rejected
with a user-facing error, on the assumption the device would reject it
anyway. Issue #54 reports a washer where that assumption doesn't hold --
default detergent/softener dosing writes through even with remote
control off, since they apply to the built-in programs too, not just a
custom remote-controlled cycle.

Add a per-device options flow (Settings > Devices & Services > this
device > Configure) with a single toggle, stored in entry.options (not
entry.data) so it doesn't affect the device's identity/unique_id.
coordinator.async_send_command reads it ahead of the existing
remote_control_enabled() check; defaults to False everywhere, so devices
that don't touch this option see no change in behavior.
2026-07-24 03:32:49 +00:00
Marc Billow 1576d095c8 ci: run pytest in CI; complete dev requirements; unblock socket test
The suite was never run in CI (only hassfest/HACS), and requirements-dev
listed only pytest + smartthings-local while conftest.py needs the full
Home Assistant test harness.

- requirements-dev.txt: add pytest-homeassistant-custom-component (pulls
  in home-assistant + pytest + pytest-socket) and the integration's
  runtime deps (cbor2, pyOpenSSL, cryptography) needed to import it.
- .github/workflows/validate.yml: add a Pytest job on Python 3.14
  (current Home Assistant's floor) that installs requirements-dev and
  runs the suite.
- test_config_flow.py: the UDP liveness-sweep test needs real loopback
  sockets, which the HA harness blocks by default; take the pytest-socket
  socket_enabled fixture so it runs instead of erroring.

Full suite: 249 passed.
2026-07-21 02:05:57 +00:00
Marc Billow 00c3ebaf75 feat: auto-detect DTLS port across the full 49152-49160 range
The config flow only probed 49154/49155, so appliances whose local
CoAP/DTLS API binds elsewhere in the ephemeral range (e.g. a dishwasher
answering on 49153) could never be added.

Add a fast UDP liveness sweep across 49152-49160 that uses the ICMP
port-unreachable / ECONNREFUSED asymmetry to find the live port(s)
before attempting the expensive DTLS handshake. Closed ports fall out
immediately; a live-but-silent port is kept as a candidate. The real
handshake then runs only against discovered ports, preferring the
historically known 49154/49155 when several look live.

Also drop the probe's /device/0 GET deadline from a bare 15s literal to
a named PROBE_GET_TIMEOUT_S constant (10s) — the slowest observed full
dump is ~8s, and 10s matches the per-resource read timeout used
elsewhere.

Bumps version to 0.5.0.
2026-07-20 21:52:35 +00:00
Marc Billow 22c5295d18 feat(washer): wire model-number fallback into discovery and config flow 2026-07-11 12:53:57 -05:00
Marc Billow d2699f0f5b Add diagnostics platform, config-flow gap warning, issue template
Completes the device-capability-diagnostics spec:

- diagnostics.py: the standard HA diagnostics hook, returning device type,
  one_ui_version, unbound hrefs, and the redacted raw resource tree, plus
  integration and smartthings-local version numbers. This is what the
  Repairs issue (added in the previous commit) points users at, and what
  they attach to a device-support issue.
- config_flow.py: _probe_and_validate now also reports oneUiVersion and
  whether the device type is recognized. Recognized types are unaffected;
  an unrecognized type shows a new confirm_unknown_type step explaining
  that only common capabilities will be available before creating the
  entry, so expectations are set at setup time rather than only after the
  fact via Repairs.
- .github/ISSUE_TEMPLATE/device-support.yml: structured template for
  filing a capability gap, linked from both the Repairs issue and the
  config-flow confirmation step.
- README: short section pointing at this whole mechanism.
2026-07-08 00:10:30 -05:00
Marc Billow 57cf1cdd11 fix: address code review findings from post-onboarding audit
- Add button platform (button.py + PLATFORMS) so oven/washer Start/Pause/Stop
  controls actually appear in HA
- Load DTLS cert chain from memory via _load_pem_chain(); eliminate all temp
  file writes for key material in config_flow and coordinator
- Fix PEM boundary: ensure leaf and CA blocks are separated by a newline in
  the stored fullchain regardless of whether the user pasted a trailing newline
- Dryer mode select: add static options tuple and value_fn to decode Course_XX
  hex strings back to human names; was permanently empty before
- Remove callable branch from LocalThingsSelect (options_field covers dynamic
  case; callable contract was broken — called with no args vs Callable[[dict]])
- Guard native_min/max_value overrides with hasattr + super() fallback to
  prevent AttributeError when native_min=None and range_field returns nothing
- Add async_close() public method to coordinator; __init__ now calls it instead
  of reaching in to _close_session directly
- Update tests: rename CONF_CERT_PEM/KEY_PEM → CA/LEAF variants, add
  leaf_cert_pem/leaf_key_pem to mock_probe return, fix mock PEM constants
  (no trailing newlines, matching what .strip() stores)
2026-06-30 16:34:39 -05:00
Marc Billow 0bb27a9204 test: scaffold pytest-homeassistant-custom-component test harness
Adds HA component tests covering the localthings integration layer
(previously only the samsung_appliance library was tested):

- pyproject.toml: asyncio_mode=auto for async HA test patterns
- tests/localthings/conftest.py: hass_config_dir override, mock fixtures
  for probe and coordinator session, fridge fixture loader
- test_config_flow.py: first-device form, second-device cred reuse,
  happy path, cannot_connect error, duplicate-device abort (5 tests)
- test_coordinator.py: discovery on first refresh, device_info populated,
  idle interval default, UpdateFailed on persistent poll error (4 tests)
- test_sensor.py: sensors registered, sensor state from coordinator (2 tests)

Total: 70 library + 11 component = 81 tests