Marc Billow 81dbc6fa03 Key devices on the OCF device ID instead of the serial number
Two Samsung air purifiers of the same model report the identical, well
formed serialNum `BS7SP9AW400114A` (issue #381). Since the entry's
unique_id, the device registry identifiers and every entity unique_id
were all minted from that string, the second unit was refused as already
configured, and would have collided entity-for-entity even if it hadn't
been.

This is the third firmware family to ship an unusable serialNum, after
`Nothing(SVC)` (#83) and the flash-unset sentinel (#189), and the first
one no heuristic can catch: the value is well formed, it's just shared.
`is_placeholder_serial` was a dead end.

So identity moves onto /oic/d's `di`, falling back to /oic/p's `pi`, then
the serial, then the host. `di` is what the protocol already uses to
address the endpoint -- if it were wrong or shared, OCF discovery and the
DTLS association wouldn't work at all -- and it's device-scoped, where
`pi` is platform-scoped and would be shared by a board hosting several
logical devices. Both units in #381 report a distinct `di`. A board that
answers neither resource lands exactly where it did before, so no
existing hardware regresses.

The re-key can't happen in async_migrate_entry: the UUID is only readable
from the device, and an entry can load entirely from its snapshot while
the appliance is off (#295). So v3 -> v4 only records the legacy key, and
the coordinator adopts the UUID on the first live poll, rewriting the
entity registry, the device registry (including subdevice identifiers)
and the entry's unique_id together. Rewriting rather than recreating is
what lets a user keep entity_ids, names, areas, statistics and every
automation that references them.

Three rules keep that adoption from misfiring:

- A poll that reads no UUID never demotes a UUID-keyed entry back onto
  its serial, so one failed reconnect doesn't re-key every entity.
- A changed UUID is followed only when the serial still corroborates it
  (a factory reset may regenerate `di`) or when the entry was keyed on
  its IP, which was never an identity to defend.
- When the identity is rejected as a different appliance, the serial
  isn't adopted either -- otherwise the intruder would gain exactly the
  corroboration needed to win the next poll.

Also stop redacting `di`/`pi` from diagnostics. They're randomly assigned
per-unit UUIDs, not account data, and blanking them is what made the
first #381 diagnostics download unable to answer the only question it was
requested to answer. The owner-set device name stays redacted.

Fixes #381
2026-08-17 05:24:22 +00:00
Marc Billow 36a642135b Fix pre-existing ty diagnostics in a second batch of test files
Same isinstance/cast narrowing and Optional-field assert pattern as the
prior commits, covering the airconditioner, fridge, washer, operational,
subdevices, sensor_hysteresis, laundry, select_options, identity and
entities test files.
2026-08-03 00:11:05 +00:00
Marc Billow daf7e3787f Add ruff (lint + format) and ty (type checking) to the project
Adds [tool.ruff] and [tool.ty] config to pyproject.toml with a curated
ruff rule set (E, F, W, I, UP, B, C4, SIM, RUF, ASYNC, LOG, G, PIE, RET,
PERF, N), pins ruff/ty in requirements-dev.txt, reformats the whole tree
with `ruff format`, and fixes the pre-existing lint and type-check debt
those tools surfaced so both run clean.

Production-code type fixes include: HA's ConfigFlowResult vs. the
generic FlowResult in config_flow.py, narrowing BoundEntity.desc to its
platform-specific subclass (SelectDesc/NumberDesc/SensorDesc/etc.) via
cast() instead of an unchecked annotation, converting HA device_class
strings to their proper enum types, a resolve_registry callback typed
as `object` instead of `DeviceRegistry | None`, and a couple of other
narrow correctness fixes (CA key type validation, an index-out-of-bounds
false positive from an empty-tuple fallback, a bool/dict argument swap).

Test-file fixes are mechanical: narrowing SamsungEntityDescription to
the correct subclass via isinstance()/cast() before accessing
subclass-only fields, and asserting Optional write_fn/unit_fn fields
are set before calling them.
2026-08-02 23:56:38 +00:00
Jelle Lauwers 9ab3c5827c Rename finish_time debounce -> hysteresis to match actual behavior
The gate holds finish_time at its last reported value until a new one
differs by at least a configured number of minutes, regardless of how
long that difference has been building up -- a magnitude-based deadband,
not a time-based debounce (which would wait for the value to stay put for
N minutes before accepting it). debounce invited the wrong mental model
for anyone reading the option name or the code later, so rename it
throughout before the option name ships: CONF_FINISH_TIME_DEBOUNCE_MINUTES
-> CONF_FINISH_TIME_HYSTERESIS_MINUTES, SensorDesc.debounce -> hysteresis,
LocalThingsSensor._debounce/_debounced_value -> _apply_hysteresis/
_hysteresis_value, and the options-flow data key/translations to match.
2026-07-31 20:27:48 +02:00