Marc Billow 81dbc6fa03 Key devices on the OCF device ID instead of the serial number
Two Samsung air purifiers of the same model report the identical, well
formed serialNum `BS7SP9AW400114A` (issue #381). Since the entry's
unique_id, the device registry identifiers and every entity unique_id
were all minted from that string, the second unit was refused as already
configured, and would have collided entity-for-entity even if it hadn't
been.

This is the third firmware family to ship an unusable serialNum, after
`Nothing(SVC)` (#83) and the flash-unset sentinel (#189), and the first
one no heuristic can catch: the value is well formed, it's just shared.
`is_placeholder_serial` was a dead end.

So identity moves onto /oic/d's `di`, falling back to /oic/p's `pi`, then
the serial, then the host. `di` is what the protocol already uses to
address the endpoint -- if it were wrong or shared, OCF discovery and the
DTLS association wouldn't work at all -- and it's device-scoped, where
`pi` is platform-scoped and would be shared by a board hosting several
logical devices. Both units in #381 report a distinct `di`. A board that
answers neither resource lands exactly where it did before, so no
existing hardware regresses.

The re-key can't happen in async_migrate_entry: the UUID is only readable
from the device, and an entry can load entirely from its snapshot while
the appliance is off (#295). So v3 -> v4 only records the legacy key, and
the coordinator adopts the UUID on the first live poll, rewriting the
entity registry, the device registry (including subdevice identifiers)
and the entry's unique_id together. Rewriting rather than recreating is
what lets a user keep entity_ids, names, areas, statistics and every
automation that references them.

Three rules keep that adoption from misfiring:

- A poll that reads no UUID never demotes a UUID-keyed entry back onto
  its serial, so one failed reconnect doesn't re-key every entity.
- A changed UUID is followed only when the serial still corroborates it
  (a factory reset may regenerate `di`) or when the entry was keyed on
  its IP, which was never an identity to defend.
- When the identity is rejected as a different appliance, the serial
  isn't adopted either -- otherwise the intruder would gain exactly the
  corroboration needed to win the next poll.

Also stop redacting `di`/`pi` from diagnostics. They're randomly assigned
per-unit UUIDs, not account data, and blanking them is what made the
first #381 diagnostics download unable to answer the only question it was
requested to answer. The owner-set device name stays redacted.

Fixes #381
2026-08-17 05:24:22 +00:00
Marc Billow 07061c734d Fix more pre-existing ty diagnostics in test files
Continues narrowing SamsungEntityDescription accesses to the correct
subclass and asserting Optional write_fn/match_fn/exists_fn fields are
set before calling them, per the pattern established in the previous
commit.
2026-08-03 00:03:08 +00:00
Marc Billow daf7e3787f Add ruff (lint + format) and ty (type checking) to the project
Adds [tool.ruff] and [tool.ty] config to pyproject.toml with a curated
ruff rule set (E, F, W, I, UP, B, C4, SIM, RUF, ASYNC, LOG, G, PIE, RET,
PERF, N), pins ruff/ty in requirements-dev.txt, reformats the whole tree
with `ruff format`, and fixes the pre-existing lint and type-check debt
those tools surfaced so both run clean.

Production-code type fixes include: HA's ConfigFlowResult vs. the
generic FlowResult in config_flow.py, narrowing BoundEntity.desc to its
platform-specific subclass (SelectDesc/NumberDesc/SensorDesc/etc.) via
cast() instead of an unchecked annotation, converting HA device_class
strings to their proper enum types, a resolve_registry callback typed
as `object` instead of `DeviceRegistry | None`, and a couple of other
narrow correctness fixes (CA key type validation, an index-out-of-bounds
false positive from an empty-tuple fallback, a bool/dict argument swap).

Test-file fixes are mechanical: narrowing SamsungEntityDescription to
the correct subclass via isinstance()/cast() before accessing
subclass-only fields, and asserting Optional write_fn/unit_fn fields
are set before calling them.
2026-08-02 23:56:38 +00:00
Ian P. Christian 6efee761d9 Add Samsung EHS (Eco Heating System) heat pump support
Adds a device registry for the TP1X_DA_AC_EHS board family: separate
zone1 (space heating/cooling) and dhw (domestic hot water) loops.
zone1 is exposed as power switch + mode select + current/target
temperature sensor/number -- it's a leaving-water-temperature
setpoint, not a thermostat, so no HA platform fits it better. dhw
gets a composite water_heater entity, using the same
primary-resource-plus-sibling-reads shape climate.py already uses
for the AC (PR #247 review feedback: "Having water heaters
automatically leverage the right platform would be pretty cool!").
The unit's away mode is a device-wide switch, not the water_heater
AWAY_MODE feature -- /option/outgoing/vs/0 has no dhw-scoped sibling
and covers zone1 too, so presenting it on the DHW card would
misstate its scope.

Operation modes (Eco/Std/Force/Power) map onto HA's own standard
water_heater states, the same mapping HA core's smartthings
integration uses for this exact Samsung capability over the cloud
API. Device codes are matched case-insensitively on the read side.
The DHW entity takes a catalog name ("Hot water") rather than the
bare device name -- unlike the AC's climate card, it is one loop of
a two-loop device.

Both temperature ranges fall back as a pair: a resource reporting a
minimum but no maximum yields no range at all rather than mixing a
device bound with an invented default, matching climate._range().
Increment fallbacks test for None instead of using `or`, so a
genuine 0 survives.

set_temperature honours the optional operation_mode HA's
water_heater service schema forwards, setting the mode (and powering
the loop on) before the setpoint, the same way climate's
set_temperature handles hvac_mode.

Entity names are translated into Czech and Dutch following each
file's existing terminology conventions.

Verified against a real TP1X_DA_AC_EHS_01001_0000 diagnostics dump
(firmware AEH-WW-TP1-22-AE6000_17260402); golden-regression fixture
and full test coverage included.