Commit Graph
84 Commits
Author SHA1 Message Date
Marc Billow 9f1bcad3ec Harden the statistics relabel against older Home Assistant and lost boots
Review follow-up on the v2 -> v3 migration.

`new_unit_class` only exists from HA 2025.11, but hacs.json still declares
2025.1 as the minimum. On anything in between, naming that keyword is a
TypeError raised out of async_migrate_entry, which fails the config entry
outright -- the integration would not load at all for those users. The
keyword is now feature-detected, and the relabel is wrapped so that no
recorder-side surprise can cost anyone the integration: it is a
convenience, and without it they simply get Home Assistant's own
units_changed repair, which is where they were before this existed.

The version bump also no longer happens when the recorder wasn't loaded.
That case isn't distinguishable from an install without the recorder, but
burning the one-shot migration on a boot where it merely failed to come up
would leave the statistics suppressed permanently, so the entry stays on
v2 and the next start retries.

The instance-suffix regex was wrong: discovery.instance_suffix yields
`_<n>`, so keys are `dust_1`, not `dust1`. Unreachable today because
AIR_QUALITY binds an exact href, but the comment claimed a guarantee the
pattern didn't provide and the test pinned a form that can't occur.

Also drops a stale claim in airconditioner.py that air_monitor rejects the
pm10/pm25/pm1 mapping, which is no longer true as of this branch.

Tests cover both signatures, the deferral and its retry, and a relabel
that raises. The older-HA guard is mutation-checked: removing the feature
detection fails it.
2026-08-15 01:23:33 +00:00
Marc Billow eeece4906c Type air_monitor's particulates and migrate the recorded statistics
Adding a unit to a sensor that recorded long-term statistics without one
is not cosmetic: Home Assistant raises a units_changed repair and then
*suppresses statistics generation* for that entity until a human resolves
it (sensor/recorder.py's compile path hits `continue`). Shipping the PM
device classes on their own would therefore have silently frozen the very
history the labels were meant to describe.

A v2 -> v3 config-entry migration relabels the statistics metadata first.
It rewrites only the metadata row, never the recorded values -- these
readings were always µg/m³ and only the label was missing, so nothing
needs converting, which is why this uses async_update_statistics_metadata
and not change_statistics_unit. It reads entity_ids back off the entity
registry rather than rebuilding them from descriptor keys, since a renamed
entity's statistic_id no longer follows from its key, and it is scoped by
device family: range_hood and airconditioner still declare no unit for
their identically-named sensors, so relabelling theirs would create the
exact mismatch this exists to prevent.

With the migration in place there is no longer a reason to hold the labels
back on air_monitor, so it takes them too. That board is one of the two
whose fixtures pin the grade bands the mapping rests on -- typing the
purifier and not the monitor was an inconsistency, not caution. It still
declines the shared state_class column, unchanged.

Recorder coupling is guarded: after_dependencies pulls it in when
configured, the import is local to the migration, and a setup without it
is a no-op. Freshly created entries mint v3 directly, having no history to
relabel.

Tested at both levels. The unit-level tests patch the recorder and assert
which entities are relabelled with which arguments, covering the renamed
entity, subdevice-prefixed and instanced keys, the near-miss keys
(dustbag_/dustbin_), the skipped families and the recorder-absent path.
Because a mock can only prove the call is made, not that it does what the
migration needs, a second suite drives a real in-memory recorder end to
end: statistics seeded unitless, migration run, metadata confirmed to read
µg/m³ / concentration, recorded means confirmed byte-identical, and the
units_changed issue confirmed present before and absent after.
2026-08-15 01:01:49 +00:00
Marc Billow 1abaad7f40 Fix issues found by an Opus review of the smartthings-local upgrade
An independent review of the last two commits' diff turned up five real
problems and one CI-breaking one. Fixed all of them:

- tests/test_coordinator_error_handling.py assigned directly onto
  coordinator instance attributes (coordinator._poll_once = dict), which
  `ty check custom_components tests` -- what CI actually runs, not the
  narrower `ty check custom_components` this branch had only been
  spot-checked against -- flags as invalid-assignment. Switched to
  monkeypatch.setattr, matching every other new test on this branch.

- coordinator.py's subdevice-enumeration failure comment claimed the
  probe "retries naturally next cycle." It doesn't: _run_discovery sets
  self._discovered = True unconditionally later in the same cycle, which
  is what gates the whole block, so a failure here is a first-and-only
  attempt, not a retried one -- a composite appliance's sibling
  subdevices are missing for the config entry's lifetime until reload.
  (A separate flag to retry wouldn't actually fix that either: every
  platform's async_setup_entry enumerates coordinator.bound exactly
  once, so a later-successful enumeration still couldn't add entities
  without a reload.) Corrected the comment and raised debug to warning,
  since the effect is silent and permanent otherwise.

- config_flow.py's new diagnostic-handshake fallback (_resolve_alert)
  was being called once per failing candidate, inside _handshake_and_read's
  scan loop -- contradicting _diagnostic_alert's own docstring ("only
  runs once every real candidate has already failed"). Two real costs:
  up to CLIENTHELLO_PROBE_TIMEOUT_S extra latency per failing port on
  the sweep-fallback path (several candidates), and -- more seriously --
  the diagnostic commits DTLS association state on each port it touches,
  which can make _probe_and_validate's own CertRejected re-mint retry
  (a fresh _handshake_and_read call against that same scan) time out
  against the very port it just polluted, per the RFC 6347 §4.2.8
  concern already documented elsewhere in this file. Moved to a new
  _diagnose_failures helper called once, after the loop, against the
  single best (confirmed-live) candidate.

- _resolve_alert also ignored the alert's level: ProbeResult.alert is
  set for a received alert of either severity, but only a fatal one (2)
  means the appliance broke off the handshake over it -- a warning
  (e.g. close_notify) was being read as a rejection reason. Older
  library exception text never had this ambiguity (OpenSSL only renders
  an exception for a fatal alert), so this was a bug the redaction
  fallback introduced. Now filters to level == 2.

- async_raw_read's new HomeAssistantError wrapper reported a translated
  error but left a confirmed-dead session installed, so every
  subsequent read/write would keep failing identically for up to the
  next full poll interval. Now closes the session on any non-TimeoutError
  failure, matching _poll_once's own posture.

- async_raw_write_sequence's verify_after fallback (vcode, vrep = 0, {})
  is indistinguishable from a real 4.04 by raw_code alone. Added a
  read_error field so a caller can tell "couldn't verify" from "the
  device said no."

Tests: 8 new/extended (once-not-per-port diagnostic count, alert-level
filtering, the warning log + permanent-loss framing, session-closing on
both async_raw_read and the verify_after path, read_error surfacing).
Full suite (1527 tests), ruff, ruff format, and -- critically --
`ty check custom_components tests` (the CI-matching invocation) all pass.
2026-08-14 18:43:44 +00:00
Marc Billow 74bdc04f56 Document the reconnect-timing change from smartthings-local's fail-fast fix
Answers a review callout on the 0.1.6 upgrade that wasn't actually
addressed, only mentioned in a commit message: a dead reader now raises
SessionClosedError (a ConnectionError) instead of hanging a request out
to its timeout and surfacing as an ambiguous TimeoutError. Mechanically
this was already routed correctly -- SessionClosedError isn't a
TimeoutError, so _defer_reconnect_for's isinstance check already skips
its multi-cycle tolerance for it -- but nothing recorded *why*, and the
callout's whole point was that downstream (i.e. this repo) should hear
about the resulting timing change explicitly, not infer it from the
dependency bump.

Before 0.1.6, a truly dead reader was indistinguishable here from a
slow blockwise transfer: both could only ever surface as a TimeoutError,
so _POLL_TIMEOUT_LIMIT's multi-cycle tolerance (~2 minutes at the
default 30s interval) was the only thing standing between a genuinely
dead session and a reconnect. Now that the library confirms reader
death directly, that failure mode skips the tolerance and reconnects on
the very first occurrence -- intended, and strictly faster recovery,
but a real change in observed timing worth calling out for anyone
correlating reconnect-log cadence with device behavior.

- _poll_once, _defer_reconnect_for, and the _POLL_TIMEOUT_LIMIT comment
  now say so directly, cross-referencing each other.
- README's "Known device behavior" section gets a paragraph so this
  isn't only visible to someone reading the coordinator's source.
- Two new unit tests pin the distinction directly:
  _defer_reconnect_for(SessionClosedError()) is False (no tolerance),
  while SessionTimeoutError keeps the existing _POLL_TIMEOUT_LIMIT
  tolerance -- so a future change can't quietly merge the two paths
  back together.

Full suite (1523 tests), ruff, and ty pass.
2026-08-14 18:15:32 +00:00
Marc Billow f949ff04c2 coordinator: close four uncaught-exception gaps around smartthings_local
A follow-up review of the 0.1.6 upgrade found four call sites where a
library exception (new typed one or the old bare ConnectionError/
TimeoutError it replaced) could escape this integration's own
reconnect/logging or a service call's translation layer entirely,
instead of being handled the way equivalent failures already are
elsewhere in this file:

- _attempt_observe_mode's own _connect_session() reconnect (fires only
  when the session was closed out from under it concurrently) had no
  try/except, and neither did either of its two call sites in
  _async_update_data. A failure there escaped uncaught: HA's
  DataUpdateCoordinator has its own final safety net so nothing crashed
  the config entry, but non-TimeoutError failures logged a full ERROR
  traceback instead of this integration's deliberately quiet "poll
  failed, reconnecting" voice, and skipped its own reconnect bookkeeping
  entirely. Fixed by catching around just the connect call (the only
  unguarded raise path in the method -- subscribe_hrefs/
  await_observe_notifies already handle their own failures), landing in
  the same "give up on push this cycle" state abandon_observe_attempt()
  already produces for the subscribe-failed and stale-session branches.
  Deliberately does not touch _close_session() (self._session is
  already None here -- _connect_session only ever publishes it after a
  full success), _reconnect_is_frequent() (that window records the poll
  path's own reconnects; feeding it a secondary path's failure would
  over-trigger its warning threshold), or _resubscribe_due (that flag
  means "a live session nothing has tried yet" -- setting it here would
  re-enter the doomed handshake every cycle instead of letting
  _last_observe_attempt_ts pace the retry).

- _enumerate_subdevices_blocking's _connect_session() call (first
  discovery only) had the same gap. Fixed the same way: log and fall
  through on the resources _poll_once already returned this cycle,
  rather than losing first discovery over a failed subdevice probe.

- async_raw_read (backing the read_resource service) had no exception
  handling at all -- a session/network failure during a live debug read
  reached the service caller as a raw, untranslated library exception,
  unlike write_resource's equivalent path. Now wrapped the same way
  async_send_command/async_raw_write_sequence already are, raising
  HomeAssistantError with a new debug_read_failed translation key
  (added to all 7 shipped locales).

- async_raw_write_sequence's verify_after tail sat outside the method's
  own try/except, so a failed confirmation read discarded the write
  results that had already landed by throwing past them. Now caught
  per-href inside the verify loop instead: a failed read is treated the
  same as a 4.04/empty one (held=None, "couldn't verify" -- not lost or
  misreported as a revert), and the rest of the batch still gets
  checked.

Design for the first fix (the trickiest -- it's mid-lock, and has to
interact correctly with observe-mode state and the poll path's own
bookkeeping without corrupting either) was worked through with a
dedicated review pass before implementing.

Tests: new coverage for all four (test_coordinator.py's
test_attempt_observe_mode_survives_a_failed_reconnect, a new
test_coordinator_error_handling.py for the subdevice-enumeration case,
and two additions to test_services.py for the read-service and
verify_after cases). Full suite (1521 tests), ruff, and ty all pass.
2026-08-14 18:09:09 +00:00
Marc Billow 3f9789512d Update to smartthings-local 0.1.6, handle redacted typed errors
Bumps the smartthings-local floor from >=0.1.2 to >=0.1.6 (manifest,
requirements-dev.txt, Dockerfile) and adopts the interface/behavior
changes introduced along the way:

- 0.1.3 ("redacted typed failures", PR #23) replaced connect()'s
  ConnectionError(f"DTLS handshake error: {e}") with fixed, redacted
  exceptions (SessionError, SessionTimeoutError, etc.) that never carry
  backend text -- including the TLS alert name. The config flow's
  _classify_handshake_failure relied on parsing that text out of the
  exception (_alert_name) to tell a rejected certificate from any other
  handshake failure; against a current library that regex never matches
  again, silently downgrading every setup failure to the generic
  "cannot_connect" message.

  Fixed by adding _resolve_alert: it still tries _alert_name first (a
  harmless fallback if it ever matches), then falls back to one bounded
  smartthings_local.protocol.dtls_probe.diagnose_dtls_handshake() call
  against the specific port that failed, which classifies the fatal
  Alert straight from the raw record instead of an exception string.
  _handshake_and_read now threads the resolved per-port alerts into
  _classify_handshake_failure, so CertRejected vs. HandshakeFailed keeps
  working the way it did before the redaction.

- 0.1.3 also moved the DTLS session onto a connected UDP socket (see
  endpoint.py's open_connected_udp_socket), which changes why
  coordinator._local_source_port needs a unique port per device -- the
  kernel now demuxes by the full local-port/remote-peer tuple instead of
  relying on an unconnected recvfrom(). Docstring updated to match.

- 0.1.6's reader-thread fail-fast fix (_check_live/_reader_running) makes
  a dead reader raise SessionClosedError immediately instead of hanging
  a request out to its timeout. No code change needed: SessionClosedError
  is a ConnectionError subclass (not TimeoutError), so the coordinator's
  existing _defer_reconnect_for/isinstance(e, TimeoutError) split already
  routes it to the immediate-reconnect path.

Every other new/changed piece (endpoint.py, dtls_probe.py bounded
probing, auth.py's CertificateAuth/PskAuth providers) stays behind
compatible built-in exception types and unchanged get()/post()/
subscribe()/ping() signatures, per the library's own compatibility
table, so the coordinator's and observe.py's broad exception handling
needed no changes.

Tests: added coverage for _resolve_alert's exception-text vs.
diagnostic-handshake fallback, _classify_handshake_failure with a
resolved alerts mapping, and an end-to-end config-flow re-mint test
against a FakeSession that raises the new redacted SessionError instead
of the old text-bearing ConnectionError.

Full suite (1517 tests), ruff, and ty all pass against smartthings-local
0.1.6 installed from PyPI.
2026-08-14 17:50:10 +00:00
Marc Billow cd3a47f9a4 Fix stuck alarm_code: never merge /alarms/vs/0 onto stale cache (#348)
ObserveManager.apply() shallow-merges every incoming rep onto whatever's
already cached for that href (issue #27's fix for /mode/vs/0's partial
notifies). That assumes an absent key always means "unchanged, keep the
old value" -- true for /mode/vs/0's supportedOptions, but backwards for
/alarms/vs/0: entity.py already documents {} as this resource's
canonical no-alarm state, and a live read_resource GET on the reporter's
washer confirmed the board sends exactly that {} when an alarm clears.
Merging it onto the prior rep left the stale ErrorCode_DC entry in the
cache forever, surviving power cycles and only clearing on a full
integration reload (which rebuilds the cache from scratch instead of
merging).

Add _is_alarms_href() to recognize /alarms/vs/<index> across every
subdevice-translated shape (MAIN identity, indexed renumbering, prefixed
UUID -- Subdevice.to_actual never touches the 'alarms/vs' stem) and have
apply() fully replace the cache for that href instead of merging. This
is a global fix: every family with an alarm sensor shares this href
(common.ALARMS, range_hood's own copy), so they were all exposed.
2026-08-12 02:41:02 +00:00
Marc Billow 4f3bdde6e5 Address review findings on the learned-modes store
Flatten the store to {href: [codes]}. One href carries one LEARNABLE
rule, so keying the codes by the rule's supported field too let the
write side (rule.supported_field) and both read sides (the module-level
SUPPORTED_FIELD) disagree the moment a rule used a different field --
codes learned and persisted, then never offered.

The options flow's reset step read the persisted value raw in the
entry-not-loaded branch, so malformed data aborted the one screen that
can clear it; route it through LearnedModes like every other reader.
For the same reason forget_learned_modes() now persists whenever the
entry carries a record, not only when the in-memory store had one: a
record _coerce rejected at startup exists only on the entry.
2026-08-08 19:42:20 +00:00
Marc Billow d65735ac47 Remember modes a device reports but never advertises (issue #327)
Some firmware reports a current mode that is missing from the same
resource's supportedModes. An ARTIK051 air conditioner sits in Quiet
while advertising only [Off, Sleep, Speed, Nano, NanoSleep], so HA
showed preset_mode: quiet and then refused to select it. A second
reporter has three identical units where only the two sharing an
outdoor unit hide it, which rules out a real capability difference.

learned.py remembers any such code and the coordinator persists it on
the config entry, so a mode the device only names while it is active
survives a restart. climate._supported unions it into the resource's
own list, which fixes the read and the write together --
async_set_preset_mode reverse-resolves the device code from that same
list.

Learning is allowlisted per canonical href rather than global. Across
the fixture corpus 17 dumps already report a current mode that is not
in supportedModes: an oven idling in NoOperation, a fridge's
/mode/vs/0 carrying capability tokens like WATERFILTER_DISABLE. Those
are not selectable options, and remembering one permanently would put
an option in the UI that the device can only reject. Only
/mode/convenient/vs/0 is learnable today.

On by default, with a per-device option that stops offering and
learning at once, and a reset step in the options flow for a code that
turns out to be bogus. Diagnostics report what was learned separately
from `resources`, which stays exactly what the device said.
2026-08-08 19:10:53 +00:00
Marc Billow 5dbe990c1d Add write_resource/read_resource services for probing write contracts (issue #300)
The options-flow "Debug write" panel could only ever do one write to one
href per pass -- not enough for the issue #300 wall oven, whose board
discards settings writes while idle and only keeps them once a cycle is
already running. Finding what starts a cycle needs an ordered sequence of
writes across resources, with real settle delays between them, and a way
to check afterward whether anything actually held.

- coordinator.py: async_raw_write_sequence owns a whole ordered sequence
  under one _session_lock hold (so a poll can't interleave mid-sequence),
  with per-step settle and an optional delayed verify_after re-read done
  outside the lock. async_raw_write is now a one-item wrapper over it, so
  tests/test_coordinator_raw_write.py keeps passing unmodified. Also adds
  async_raw_read, a live GET bypassing the cache -- staleness is exactly
  what makes revert-testing unreliable.
- services.py (new): the two HA services. Device-target resolution scans
  loaded coordinators' MAIN/subdevice identifiers and requires exactly one
  match, so an area/label target can't silently fan a raw write out across
  several appliances. Canonical->actual href translation happens here, not
  in the coordinator, which stays subdevice-agnostic.
- services.yaml (new): selectors/descriptions for both services, inline
  per HA's custom-integration support -- keeps translations/en.json's
  mirror test (test_translations.py) green without touching all 6
  languages for a services block. New exception keys (write caps, device
  target resolution) still went into translations/*.json's existing
  exceptions section, mirrored across all 6 languages.
- __init__.py: adds async_setup to register the services once, process-wide.
- config_flow.py: the debug panel's async_step_debug_edit now calls
  write_resource instead of coord.async_raw_write directly, so there is
  exactly one code path that performs a raw write.
- README.md: new Part 5 documenting both services, with a worked
  write_resource example; points the capability-gap section at them.

tests/test_services.py (new): sequencing/ordering, settle timing, changed
vs. held (the reverted case is issue #300's own symptom), exactly-one-
device resolution, subdevice href translation, validation caps, and the
options-flow panel end to end through the service.
2026-08-07 22:08:28 +00:00
Marc Billow e3e7f4f43c test: suppress ty's invalid-assignment on the fake-session swap
coordinator is explicitly typed as LocalThingsCoordinator here, so ty
correctly sees _session's declared type (DtlsCoapSession | None) and
flags assigning a FakeObserveSession to it. The fixture's own
_connect_session replacement does the same swap without tripping ty,
but only because its self parameter is unannotated -- ty has nothing to
check the assignment against there. Deliberate here (this is the whole
point of the test: substitute a stand-in session), so silenced rather
than restructured; ty's --add-ignore confirmed the comment syntax
(ty: ignore[...], not the mypy-style type: ignore[...] used elsewhere
in this suite, which ty doesn't appear to honor for this rule).
2026-08-06 02:07:39 +00:00
Marc Billow a3cc918343 fix(coordinator): two gaps a follow-up Opus review found in the split
A second review of the observe-mode phase split (previous commit) found
two real regressions it introduced, both in the same failure family it
was built to close:

- async_send_command's failed-retry branch closed the session, then
  raised without downgrading observe mode -- the downgrade only ran on
  the retry's success path. A retry that also fails still leaves the
  session dead, so mode was left claiming "Push" on a session that no
  longer exists, same as the bug this whole fix targets. Moved the
  downgrade to run right after the close, unconditionally on how the
  retry goes.

- _attempt_observe_mode's stale-session abandon (the identity-check
  branch added in the previous commit) didn't flag a resubscribe. A
  session swap discovered there means a fresh, never-tried session now
  exists, but _last_observe_attempt_ts was already stamped for the
  now-abandoned attempt -- so that new session sat unsubscribed for up
  to _RECOVERY_RETRY_S (600s) instead of being retried on the next
  cycle. Now sets _resubscribe_due, same as the two reconnect paths do.

Also closes two test-coverage gaps the same review surfaced by mutation
testing: no test asserted the lock actually holds during the subscribe
burst (only that it's released for the wait), and no test distinguished
the max() in _maybe_retry_observe_mode's throttle from using
_last_observe_attempt_ts alone -- both mutations left the full suite
green. Added one test for each, plus extended two existing tests for the
bug fixes above; all four confirmed via mutation testing (revert the
fix, watch the new/extended test fail; restore it, watch it pass).

One finding from the same review is intentionally left open: async_close
is the one self._session writer that doesn't take _session_lock, so a
close racing _attempt_observe_mode isn't covered by today's identity
check. This is pre-existing (the lock didn't cover any of
_attempt_observe_mode before this branch's earlier commits either), not
a regression from this branch's work, and is a shutdown/unload-path
question rather than the write-vs-observe-mode race this branch set out
to fix.
2026-08-06 02:01:30 +00:00
Marc Billow 69f93be4dc fix(coordinator): close the observe-mode race an Opus design review found
The command-retry fix (issue #294) added a self._close_session() call to
async_send_command that isn't synchronized against _attempt_observe_mode,
which reads self._session and subscribes to it without holding
_session_lock. A write's retry racing an in-flight subscribe attempt
could tear down the session mid-subscribe -- or worse, land the close
*after* the attempt's grace wait already succeeded, letting it commit
observe mode against a session that's already gone: mode claims "Push"
forever, with nothing left to notice the underlying socket is dead.

Split ObserveManager.try_enter_observe_mode into four pieces
(subscribe_hrefs / await_observe_notifies / enter_observe_mode /
abandon_observe_attempt), keeping try_enter_observe_mode as a thin
wrapper so its direct callers in test_observe.py are unaffected.
_attempt_observe_mode now holds _session_lock only for the subscribe
burst (each send is fire-and-forget, not a network round trip) and
re-checks self._session is sess under the lock right before committing
-- sess keeps the old session object alive, so identity can't be
recycled onto a new one, which is what makes the check sufficient
without a separate generation counter. The wait itself stays lock-free,
so a command write is never blocked behind it.

Two more bugs the same investigation turned up, fixed in the same pass
since they're direct consequences of the design above:

- async_send_command's own successful reconnect didn't downgrade observe
  mode the way the poll path's reconnect already does, leaving the same
  stale-commit problem reachable with zero concurrency at all -- just a
  write's retry succeeding while mode was observe. Replaced the poll
  path's local just_downgraded_from_observe with an instance flag both
  reconnect sites set, so either one triggers an immediate resubscribe.

- _maybe_retry_observe_mode's 600s throttle gated solely on
  last_mode_change_ts, which _set_mode only stamps on an actual
  transition -- a device that never succeeds at observe mode leaves that
  timestamp stuck at construction time, so the throttle opens once and
  never closes again, re-attempting on every single poll cycle instead
  of every 600s. Now gates on the more recent of that timestamp and a
  new _last_observe_attempt_ts, stamped on every attempt regardless of
  outcome.
2026-08-06 01:39:03 +00:00
Marc Billow 50bb893407 review: re-arm the settle window on retry, tighten comments, close a test gap
An Opus review of the three prior commits on this branch (PR #306)
turned up two real defects and a documentation/test gap, all fixed
here:

- async_send_command's retry (issue #294) armed the write-settle
  window before the retry existed, so the reconnect pause plus a
  second PUT could eat into the time meant for the confirming poll,
  reviving the revert-then-reapply symptom the window was sized to
  prevent (issue #9). Re-arm it after a successful retry lands.

- test_send_command_reconnects_and_retries_after_socket_closed relied
  on the observe-session fixture's no-op _close_session, so
  self._session never actually went None and _do_put's reconnect
  guard was never exercised -- the test passed even with that guard
  deleted. Now overrides _close_session/_connect_session to actually
  drop and rebuild the session, and asserts the reconnect happened.

- async_send_command's docstring still said "Fire-and-forget", which
  stopped being true the moment it started retrying and raising.

Also trimmed the three comment blocks the review flagged as
reproducing their commit messages verbatim, per CONTRIBUTING.md's
comment-style rules.

One review finding is not addressed here and needs a decision: the
new _close_session() call in the command-retry path isn't
synchronized against _attempt_observe_mode, which touches the session
without _session_lock. A write's reconnect can race an in-flight
observe-mode subscribe attempt and tear down the session it's using.
Fixing it properly means broadening lock scope around observe-mode
entry, which risks blocking a write behind an up to ~15s subscribe
grace period -- a tradeoff not made unilaterally here.

A second finding (dropping the old .strip()'s per-line whitespace
handling in _normalize_pem) did not reproduce against a real
certificate/key, only against the test suite's placeholder PEM body,
so it's left as-is.
2026-08-06 01:06:22 +00:00
Marc Billow 77c2d7831e fix(coordinator): retry a command once after a dead-session reconnect
async_send_command's _do_put caught any exception, logged it, and
returned -- no reconnect, no retry, no error the user could see. A
command landing on a session Samsung's firmware closed between polls
(the same 'known device behavior' _async_update_data already
reconnects around) was silently lost, with nothing to do about it but
a manual reload of the device (issue #294).

Mirror the poll path's own recovery: on failure, close the dead
session, pause, and retry the PUT once against a freshly reconnected
one. If that also fails, raise a HomeAssistantError instead of just
logging, so the user gets a visible error rather than a command that
quietly did nothing. The retry runs under the same session lock the
poll path uses, so a write landing mid-reconnect can't race a
concurrent poll cycle rebuilding the same session.
2026-08-06 00:44:35 +00:00
Marc Billow 252306838d fix(coordinator): downgrade observe mode when a device stays unreachable
When a poll fails and the immediate reconnect retry fails too,
_async_update_data returned the last-known snapshot as a degraded
success (issue #254) without ever touching observe mode. That's fine
for the data itself, but the connection-mode sensor reads straight
from self._observe.mode, and only the *successful* reconnect branch
ever changed it -- so a device that drops off the network entirely
(air-gapped, powered off, Wi-Fi down) left that sensor reporting
"Push" forever, hours after the session was actually dead (issue
#287).

Downgrade to poll mode on the failure branch too, without attempting
an immediate resubscribe: the reconnect that would normally justify
one just proved there's no live session to subscribe on. Recovery
still happens on its own once the device is reachable again, via the
existing poll-mode retry timer (_maybe_retry_observe_mode).
2026-08-06 00:42:31 +00:00
Marc Billow 455ed5b27c fix(config_flow): normalize a pasted PEM before parsing it
A PEM pasted from a text editor can carry bytes cryptography's parser
refuses outright: a UTF-8 BOM some Windows editors silently prepend,
CRLF line endings, and a stray blank line a paste can introduce
between the header/body/footer. None of those are meaningful in PEM,
but any of them surfaces as an opaque InvalidHeader with no hint of
what's wrong -- which is why the same certificate pasted from
Command Prompt's `type` (no BOM, no stray blank lines) loads fine
while the same file opened in an editor and copied doesn't (issue
#291).

Normalize at the point the pasted blob is first captured, not just
before minting the leaf cert: the same string is stored in the config
entry and reused to re-mint the leaf on a future reconfigure, so a
raw copy would keep failing every time it's read back, not just on
the first attempt.
2026-08-06 00:41:43 +00:00
Marc Billow b5699badbe Stop the v1 migration re-keying devices onto a placeholder serial
_serial_from_unique_id took the entry's unique_id at face value. That is
right for an entry whose unique_id holds a real serial, but the unique_id
records what the config flow believed when it ran, not what the registry
holds now -- and for two firmware families those are different things.

Entries added before the placeholder rules landed (issues #83/#189) were
keyed on the placeholder itself: `localthings_Nothing(SVC)` for the
ARTIK051_DONGLE_REF dongles, `localthings_FFFFFFFFFFFFFFF` for the
DA_WM_A51_20_COMMON laundry boards. The coordinator has been resolving
those same boards to the host ever since, so their devices and entities
are host-keyed today. Migration read the placeholder back off the
unique_id, decided the host-keyed rows were the stale ones, and rewrote
them onto the placeholder -- reintroducing exactly the collision those
issues exist to prevent, since every unit of the family reports the same
placeholder and would go back to sharing entity unique_ids.

Run the recovered string through resolve_serial, which is the whole point
of that helper being shared. The old `host:port` special case stays: it's
a config-flow-history artifact rather than a device-reported serial, so
resolve_serial can't recognize it.

The repair pass had a second, narrower way to lose data. Removing a device
takes its entities with it (entity_registry.async_device_modified), and
the removal branch ran after the entity pass -- so an entity that had just
been re-keyed rather than removed, because its serial-keyed key was free,
was destroyed a few lines later along with the entity_id, name and area
the rewrite existed to preserve. Move surviving entities onto the device
they now belong to before removing the duplicate.

Reachable when the serial-keyed device exists but a given entity's
serial-keyed key doesn't -- e.g. the user deleted the visible duplicate by
hand, which is the first thing anyone hitting #236 tries.

Also fold the modelNum `<model>|<board>` split into resolve_model beside
resolve_serial. The config flow and _run_discovery each had their own copy
under a comment promising they matched; a device that renames itself on
the first poll is what a drift there looks like.
2026-08-04 00:12:40 +00:00
Marc Billow 6033709f24 Replace the blanket "cannot connect" with a real failure taxonomy
Adding a device had one message for nearly every way it could fail: "Cannot
connect to the device. Verify the IP address is reachable and the CA
credentials are correct." That covers an IP with nothing on it, an
appliance on cloud-only firmware, a device still holding the session from
the last attempt, a device that answered and rejected our certificate, and
Home Assistant having no internet to reach Samsung's cloud. Only one of
those is fixed by checking the IP and the CA credentials, and the message
gave no way to tell which one you had.

The probe already gathers enough to tell them apart, so classify it:

- cert_rejected     the appliance sent a certificate alert. The CA
                    credentials aren't the AC14K_M CA it trusts, or they
                    don't pair. Far and away the most common real setup
                    mistake, and previously indistinguishable from a typo
                    in the IP address.
- handshake_failed  a fatal alert unrelated to the certificate (protocol or
                    cipher mismatch) -- no amount of fiddling with CA
                    credentials will fix it.
- handshake_timeout the ClientHello probe proved a DTLS server is right
                    there, but the handshake never finished. Usually the
                    appliance is still holding the association from a
                    previous attempt; it clears on its own in about a
                    minute.
- ports_closed      ICMP port-unreachable on the whole range: something is
                    at that address and it isn't exposing a local API.
                    Cloud-only firmware (TCP 8888 only) lands here.
- no_dtls_server    some ports open|filtered, none speaking DTLS -- likely
                    another device on that IP.
- no_response       nothing came back at all.
- cloud_unreachable couldn't reach Samsung's cloud gateway for the UUID.
                    An internet problem on HA's side, not the appliance's.
- unexpected_response  authenticated fine, then returned something we can't
                    read. Neither connectivity nor credentials.

Certificate alerts are read back out of the error text OpenSSL puts in
DtlsCoapSession's ConnectionError, not by re-probing. The library's
diagnostic probe would report the alert authoritatively, but it drives the
handshake far enough to commit association state on the device -- and an
orphaned association is exactly what makes the *next* attempt time out
(RFC 6347 4.2.8), which is a bad trade on a path the user is about to
retry.

Telling ports_closed from no_response needs the UDP sweep to separate a
refusal from an unreachable. Both leave a port "not live", but ECONNREFUSED
is a *response* -- the host is there -- while EHOSTUNREACH/ENETUNREACH mean
the datagram never left. A wrong IP on the local subnet never answers ARP
and fails every send that way, so treating the two alike would have told
those users their appliance was on cloud-only firmware. The sweep now
returns live/refused/unreachable separately, and the preferred-port rescue
moved out of it into _sweep_ports: the rescue is a candidate-selection
decision, and folding it into the sweep's verdict destroyed the evidence
the message is built from.

Every failure carries the error key that fits it, so the flow maps
exceptions instead of guessing, and logs the specifics (alert name, per-port
outcome, response code) at warning level -- the messages that mention the
log now have something to point at.

Certificate re-minting for a reused leaf is also narrower and more correct
as a result: it now triggers on CertRejected specifically, rather than on
"every attempt raised ConnectionError and a port was confirmed".

All five translation catalogs carry the eight new messages. The non-English
ones are my own work rather than a native speaker's; corrections welcome.
2026-08-03 20:29:53 +00:00
Marc Billow 15be379243 Rebuild device discovery on the ClientHello probe and resolve identity up front
Two problems, one setup path.

Port detection (issue #211): the config flow found the DTLS port by
elimination -- a 1-byte UDP probe can't tell a silent port from a real
DTLS server, so every port it couldn't rule out got a full certificate
handshake, and every false positive cost the whole 12s HANDSHAKE_TIMEOUT_S
before the next was tried. Adding an appliance took 30-40s.

smartthings-local 0.1.2 ships a stateless ClientHello probe that settles
this positively: a real DTLS server answers with a HelloVerifyRequest in
~1 RTT, and per RFC 6347 4.2.1 it does so without allocating association
state, so the probe leaves nothing behind on the appliance. The whole
49152-49160 range is probed at once and exactly one confirmed port is
given a certificate handshake. Fanning out is safe here in a way racing
real handshakes is not -- each probe is bounded by a 3s budget, so the
pool costs one probe's wall clock rather than the sum of the range, with
no losing threads left running behind us.

The UDP sweep stays as the fallback for when the probe confirms nothing:
it errs in the opposite direction (it reports everything it can't rule
out), so it still surfaces a device on a path that eats our ClientHello,
and it keeps its issue #192 preferred-port rescue.

Port detection now runs first and needs no credentials, so an unreachable
host fails before any round trip to Samsung's cloud. And a second
appliance reuses the existing entry's leaf cert rather than re-minting --
every device accepts the same one -- which makes adding one independent
of Samsung-cloud reachability. A confirmed-live device rejecting the
reused leaf (the UUID does rotate) re-mints and retries once, so reuse
stays self-correcting; a timeout doesn't, since a fresh cert can't fix
nothing answering.

Identity (issue #236): the coordinator seeded device_serial with the
configured host and only replaced it after the first successful poll. But
device_serial mints *permanent* registry keys -- entity unique_ids and
device identifiers -- so anything registering before that poll returned
was written into the registry keyed on the IP address forever. The
connection-mode sensor is added unconditionally rather than from `bound`,
so it was the reliable victim: when the serial-keyed identity appeared
moments later HA created a second device and entity, and the IP-keyed
pair was orphaned. Deleting them didn't help; the next restart that lost
the race recreated them.

The probe already learns the identity, so store it on the config entry --
serial, model, manufacturer, device type. The coordinator seeds
device_serial and its DeviceInfo from those at construction, so keys are
correct from the first entity that registers even if the first poll is
slow or fails outright. There is no placeholder left to correct.

Discovery now treats the registered identity as authoritative rather than
re-keying a device that already has registry entries; it adopts and
persists the polled identity only for an entry that has none, and warns
if a different appliance answers on the same IP.

Entry version 1 -> 2 recovers the serial from the entry's unique_id (the
flow has always keyed it on the probe's serial) and repairs what the old
registration orphaned: IP-keyed devices and entities are rewritten in
place where the serial-keyed key is free -- keeping entity_id, name, area
and every automation referencing them -- and removed where both exist,
since the IP-keyed one has been dead since the restart that made it.
Placeholder-serial boards (issues #83/#189) were keyed two ways at once,
`host:port` on the entry and `host` in the registry; migration collapses
the entry onto the registry's form. One resolve_serial() now serves both
sides, so they can't drift apart again.

The remaining step in the desired pipeline -- probe for subdevices, then
register devices, then populate entities -- already holds:
_enumerate_subdevices_blocking runs before _run_discovery, which runs
before platforms are forwarded. Duplicating it in the config flow would
mean re-running Pattern B's per-href fallback probe, which is the
opposite of what issue #211 is about.
2026-08-03 20:14:54 +00:00
Marc Billow 24d48d70b9 Reformat after merging main
main advanced past this branch (PR #263, entity-less-after-restart fix)
with unformatted changes to coordinator.py's tests; re-running ruff
format picks those up. Merge commit itself had no conflicts.
2026-08-03 00:21:34 +00:00
Marc Billow 18596f23ec Merge remote-tracking branch 'origin/main' into claude/ruff-pyright-ci-stage-gxph0t 2026-08-03 00:20:59 +00:00
Marc Billow 679c3d2bce Fix remaining pre-existing ty diagnostics in test files
Completes the isinstance/cast narrowing + Optional-field assert pattern
across the last batch of test files. custom_components and tests are
now both fully clean under ruff check, ruff format --check, and ty check.
2026-08-03 00:14:58 +00:00
Marc Billow 36a642135b Fix pre-existing ty diagnostics in a second batch of test files
Same isinstance/cast narrowing and Optional-field assert pattern as the
prior commits, covering the airconditioner, fridge, washer, operational,
subdevices, sensor_hysteresis, laundry, select_options, identity and
entities test files.
2026-08-03 00:11:05 +00:00
Marc Billow daf7e3787f Add ruff (lint + format) and ty (type checking) to the project
Adds [tool.ruff] and [tool.ty] config to pyproject.toml with a curated
ruff rule set (E, F, W, I, UP, B, C4, SIM, RUF, ASYNC, LOG, G, PIE, RET,
PERF, N), pins ruff/ty in requirements-dev.txt, reformats the whole tree
with `ruff format`, and fixes the pre-existing lint and type-check debt
those tools surfaced so both run clean.

Production-code type fixes include: HA's ConfigFlowResult vs. the
generic FlowResult in config_flow.py, narrowing BoundEntity.desc to its
platform-specific subclass (SelectDesc/NumberDesc/SensorDesc/etc.) via
cast() instead of an unchecked annotation, converting HA device_class
strings to their proper enum types, a resolve_registry callback typed
as `object` instead of `DeviceRegistry | None`, and a couple of other
narrow correctness fixes (CA key type validation, an index-out-of-bounds
false positive from an empty-tuple fallback, a bool/dict argument swap).

Test-file fixes are mechanical: narrowing SamsungEntityDescription to
the correct subclass via isinstance()/cast() before accessing
subclass-only fields, and asserting Optional write_fn/unit_fn fields
are set before calling them.
2026-08-02 23:56:38 +00:00
Marc Billow 00abfb9770 Tighten the #254 fix after review
No behavior change to the fix itself; cleanup only.

Production:

- Trim the narrative that was told three times over (coordinator
  docstring, test docstring, inline comment) down to one telling in the
  docstring, where someone tempted to remove the gate will be standing.
- Guard the second degraded return in _async_update_data on
  self._discovered too. That arm is currently unreachable before
  discovery only because every _observe.apply() call site happens to be
  gated on post-discovery state -- a non-local accident across four call
  sites. Stating the precondition where it is relied on makes it the same
  explicit rule _defer_reconnect_for now applies.

Tests, 7 -> 4 with better discrimination:

- test_session_closed_when_first_refresh_fails asserted _close_session
  was called, which the reconnect path already does on its own -- so it
  passed with the fix removed. Merged into the persistent-timeout test
  and re-pointed at async_close, which only setup calls.
- Dropped the __new__-built unit test: it set one attribute on an
  otherwise uninitialized instance, so it asserted the gate's position in
  the function rather than any behavior, and would have errored rather
  than failed if reordered.
- Folded the timeout-budget test into the recovery test it was a
  byte-for-byte copy of, and replaced both hand-rolled call counters with
  the side_effect=[exc, resources] idiom already used in this file.

Each of the three production changes is now independently covered:
removing any one of them alone fails the suite.
2026-08-02 23:44:38 +00:00
Marc Billow 9fc04e179e Fix devices coming up entity-less after a Core restart
A failed DTLS handshake on the very first poll was being swallowed, so
the config entry loaded with no entities at all and stayed that way until
the user reloaded that device by hand (issue #254).

_poll_once() connects when there is no session yet, so connect()'s
handshake timeout reaches _async_update_data as a TimeoutError -- the
same type a slow blockwise transfer raises mid-session.
_defer_reconnect_for() only knew the mid-session meaning and deferred it,
making _async_update_data return flatten([], {}) == {} instead of
raising. DataUpdateCoordinator counts any non-raising return as success,
so async_config_entry_first_refresh saw a healthy first refresh and
skipped ConfigEntryNotReady, and setup forwarded the platforms with
`bound` still empty. Platforms enumerate `bound` once and have no dynamic
add-listener, so a later cycle repopulating it added nothing: every
restored entity sat unavailable until a manual reload.

Gate the deferral on self._discovered. Before the first discovery a poll
failure now takes the normal path -- one reconnect attempt, then
UpdateFailed -> ConfigEntryNotReady -- so HA retries on its own backoff
until the handshake goes through.

Two related fixes in the same failure path:

- Close the DTLS session on EVENT_HOMEASSISTANT_STOP, not only on entry
  unload. HA does not unload entries on a Core restart, so async_close()
  never ran and the previous run's association was left orphaned on the
  appliance -- which is what makes the next run's handshake time out in
  the first place. The fixed source port still covers the unclean-exit
  case where no close_notify can be sent.

- Close the session when first refresh fails. _poll_once deliberately
  leaves it open on a TimeoutError, so a failed setup abandoned a bound
  UDP socket on a port that is fixed per device by design, and each HA
  retry bound another socket to that same port.
2026-08-02 23:26:50 +00:00
Marc Billow 93744e80f4 Merge pull request #227 from blka/observe-grace-early-exit-upstream
Observe grace-period early-exit (first-refresh ~15s -> ~0.4s)
2026-07-31 20:20:22 -05:00
blka f19abc7936 feat(observe): early-exit grace wait on success fraction
Replace the fixed time.sleep(GRACE_PERIOD_S) in try_enter_observe_mode
with a threading.Condition.wait_for(predicate, timeout=grace_period_s)
that returns as soon as success_fraction of subscribed hrefs have
notified. Production data (fridge TP2X_REF_20K): all 13 hrefs notify
within ~0.34s of subscribe, so every successful first-refresh / observe
retry was waiting ~14.6s of dead time. AC retry cycles showed the same
16s-fetches-that-transition pattern.

No behavior change on the fallback path (fraction not reached → wait
the full ceiling → MODE_POLL, identical to today). GRACE_PERIOD_S and
SUCCESS_FRACTION unchanged. No smartthings_local library change.
2026-07-31 09:06:19 +02:00
Marc Billow e642db462d fix: recognize all-same-hex-digit placeholder serials (#189)
_is_placeholder_serial only caught the ARTIK051_DONGLE_REF family's
'Nothing(SVC)' sentinel. The DA_WM_A51_20_COMMON (ARTIK051) laundry
board family reports a different one instead -- every character the
same repeated hex digit -- which passed through as a real, non-unique
serial. Two different physical units (a washer and a dryer) both
reporting the literal serialNum 'FFFFFFFFFFFFFFF' collided on the
config-entry unique_id, so the second device's config flow aborted as
already configured. Widen the check (both the config_flow.py and
coordinator.py copies) to also catch that sentinel shape.
2026-07-31 01:59:49 +00:00
Marc Billow 5e86f147d4 fix(subdevices): don't materialize a slot whose only live state is a meter
Issue #214: a single-split ARTIK051_KRAC_18K showed up in HA as two air
conditioners. Its /device/1 answers the same unused-slot shape the Pattern A
reporter's /device/2 does -- every operational rep empty {} -- but also
reports a populated /energy/consumption/vs/1. Running discovery against the
reporter's own quoted subdevice block reproduces their diagnostics exactly
(21 bound entities, the same six hrefs), and of those 21 the only primary
entity with a non-None value is energy_kwh: a lifetime kWh total was the
sole thing passing discover_partitioned's liveness gate and materializing
the phantom.

A single-split AC has one compressor and one energy meter, so a
whole-appliance running total appearing under a second index is the
appliance's own bookkeeping, not evidence that hardware is installed at that
slot. Exclude cumulative meters (HA's total/total_increasing state classes,
plus the energy/water/gas device classes for the descriptors that
deliberately declare no state class) from the gate. The gate never applies
to MAIN, and across the whole fixture corpus every device has at least one
non-meter live primary, so no existing device's entities change -- verified
by the golden for the new fixture being identical to the plain KRAC one.

Also implement async_remove_config_entry_device. A subdevice's HA device
outlives the discovery that created it, so a phantom materialized by an
earlier release stays in the registry with no way to delete it from the UI
-- which is the state the second reporter on that issue is in, with a
refrigerator whose diagnostics now report no subdevices at all. Devices the
entry currently provides still refuse removal. No automatic pruning:
enumeration is one-shot and a real sibling can miss a poll (issue #205 on
the reference hardware), so auto-removal would discard a live subdevice's
name, area and automations on a transient miss.

The new fixture's /device/1 seed is the reporter's verbatim capture; its
master half comes from the corpus's other KRAC unit, with the deviations
spelled out in seeds_note.

Claude-Session: https://claude.ai/code/session_01HzUMLnSWBT64o4BQkVEzXp
2026-07-30 18:23:47 +00:00
Marc Billow bd3ca80d3c review: address Opus code-review findings on this branch
- config_flow: the #192 port-rescue made the "every port refused" fast-fail
  permanently unreachable (PREFERRED_PROBE_PORTS is always non-empty and
  always rescued), so removed the dead branch instead of leaving it as
  misleading dead code. A dead host now fails via the handshake loop's own
  error, which carries the real per-port reason.
- oven._has_option: added the is_stub_rep carve-out cooktop.py's identical
  per-token exists_fn already has on the same kind of href, so a not-yet
  sub-polled /mode/vs/0 doesn't permanently exclude energy_saving/
  cooktop_on_alert before their first real fetch lands.
- airconditioner.ENERGY_METER_LEGACY: build via dataclasses.replace() like
  its ENERGY_METER_GENERIC sibling, instead of hand-copying href/poll_tier
  (which would silently drift if common.ENERGY_METER ever gains a field).
- Fixed two stale comments: is_legacy_board()'s docstring still listed
  Volume among tokens needing legacy-only gating, though 'beep' now applies
  unconditionally across board generations; and common.py's UNIVERSAL
  invariant comment didn't mention that airconditioner also now excludes
  ENERGY_METER from the wholesale bundle.
- #191 (CAC token): added the fixture/golden/capability-test coverage the
  AVT token in the same branch got, including an honestly-documented list
  of the ten hrefs this board generation doesn't cover yet.
- fridge.cooler_temperature_setpoint: dropped the hardcoded "N °C" state
  labels -- the resource's own unit field isn't necessarily Celsius on a
  different model reporting the same href, and the options themselves are
  already read live via options_field, so a static per-value label risked
  asserting the wrong unit for a future device sharing this capability.
- airconditioner._legacy_cumulative_power_kwh: parse with float (matching
  common.wh_to_kwh's own numeric parsing) instead of this module's
  integer-only _int, so a decimal-formatted reading doesn't raise.
- test_config_flow: the port-rescue test bound the real 49154 directly,
  which could collide with an actually-running service on some machine;
  now monkeypatches PREFERRED_PROBE_PORTS to an OS-assigned port instead.
- oven.py: consolidated six byte-for-byte-identical single-token options
  write_fns (lamp/sound/fast_preheat/natural_steam/energy_saving/
  cooktop_on_alert) into one _option_switch_write(prefix) factory.

845 tests passing (up from 841 -- 4 new CAC coverage tests).
2026-07-29 18:04:23 +00:00
Marc Billow e8df8f7b0c fix(config_flow): always retry historically-confirmed DTLS ports (#192)
The liveness sweep's ICMP-based verdict isn't trustworthy on every network
path -- a segregated-VLAN report showed it calling three closed ports live
while missing the one port a concurrent nmap scan found genuinely
open|filtered, which also happened to be one of our two historically
confirmed DTLS ports. Rather than trust a "not live" verdict against that
prior, always give PREFERRED_PROBE_PORTS a real handshake attempt even when
the sweep excludes them, bounded to at most those two extra attempts.

This is a stop-gap for the reported failure mode, not a full fix for the
sweep's underlying unreliability -- left a comment on the issue with the
diagnosis and flagged the sweep itself for a deeper redesign.
2026-07-29 12:53:56 +00:00
Marc Billow 10d5c81d9a feat(diagnostics): speculatively probe /device/1 and /device/2
/oic/res's baseline-Interface response only lists resources with the
discoverable policy bit set, and a real dump (issue #177 follow-up,
TP1X_REF_21K) confirms /device/0's whole x.com.samsung.da.* tree is
registered without it -- so a second logical Device's Collection, if
one exists, would be just as invisible to /oic/res as /device/0 is.
Probe /device/1 and /device/2 directly instead: a plain non-mutating
RETRIEVE, tolerated-404 same as every other speculative read in this
module. Parsed with the same parse_device0_batch used for /device/0
itself, and folded into identity.raw so diagnostics can tell "checked,
found nothing" apart from "never checked".
2026-07-29 04:08:19 +00:00
Marc Billow 0c8d39fb73 feat(diagnostics): capture /oic/res discovery links
/oic/res is OCF's baseline resource-discovery endpoint: a unicast
RETRIEVE returns every href/Collection the connection hosts, not just
the one /device/0 seed path the coordinator polls. Relevant to the OCF
"Composite Device" model (issue #177) -- a single physical unit sharing
one IP/session across more than one logical Device, each exposed as its
own Collection resource (same rt shape as our own /device/0). Nothing
routes on this yet; captured alongside the existing /oic/p and /oic/d
reads so a report from a multi-unit device shows us whether its
firmware actually implements that model before any code assumes it does.
2026-07-29 03:53:27 +00:00
Marc Billow c9620b47b3 fix(diagnostics): redact the OCF device name; log description on unknown type
Two things a review of this branch turned up.

/oic/d's `n` is free text the owner sets from the SmartThings app, so it may
carry a person's name. Nothing in the /device/0 dump has ever exposed it --
it only became reachable when diagnostics started reporting /oic/d earlier
in this branch, which would have started carrying it into public issue
reports. Redact it. `rt`, the device-type signal the block exists for, is
untouched, and no /device/0 resource uses a bare 'n' key, so nothing else
changes.

The unknown-device-type warning logged only modelNum. That line is what a
user pastes into an issue, and modelNum alone can't identify a washer from a
dryer -- both report the shared DA_WM_ laundry board, and detection reads
the consumer-model code out of `description` for exactly that reason. Log
both fields.
2026-07-29 02:20:37 +00:00
Marc Billow cafd7d5afa refactor(registry): drop oneUiVersion from device-type detection
oneUiVersion looks like the signal you'd want -- the device naming its own
type, '7.0 Dishwasher' -- and it was the first thing detection consulted. It
never earned the position:

- Only 7 of 49 fixtures report it at all.
- All 7 resolve to the same registry from their modelNum board token alone.
- No device-support issue has ever been fixed by adding a mapping for it.
  Every one went through modelNum. The alias keys it needed in
  _REGISTRY_BY_KEY ('airpurifier', 'air_conditioner', 'hood') were
  speculative when the registries were first written and never used since.

So it bought a key-normalizing helper (_type_key), a lookup with a suffix
fallback (for_device), three alias keys, and a second config-flow step whose
only reason to exist was phrasing a sentence about oneUiVersion -- for a
signal that has never once been decisive.

Remove it from detection. It stays in diagnostics, where it's genuinely
useful: it names the firmware generation ('7.0 Air conditioner' is Tizen
Lite), which matters when triaging an issue.

Detection order was also duplicated in four places -- the coordinator, the
config flow's probe, the golden-regression harness, and the skill -- which
is how the harness and the shipped order drift apart. Collapse it into
by_type.resolve(resources), and call that everywhere.

The two "appliance type not recognized" config steps become one. They
differed only in whether they blamed a missing oneUiVersion, which is not a
distinction a user can act on, and never was.

Verified by the full suite (795 passing), including every golden regression
-- so entity output is byte-identical for all 49 device fixtures.

TestOneUiVersionIsNotConsulted locks in the premise rather than just the
outcome: for every dump that reports a oneUiVersion, the model strings alone
must still reach a registry. If a future device breaks that, the test says
so instead of the device silently losing half its entities.

Also note in requirements-dev.txt that Python 3.13 resolves the pinned
harness floor -- 3.12 and older resolve nothing and fail the whole install.
2026-07-29 02:14:13 +00:00
Marc Billow 288ba02cc5 feat(diagnostics): capture /oic/p and /oic/d identity
Device-type detection currently parses board part numbers out of
/information/vs/0's modelNum. OCF has a standard field for exactly this
question -- /oic/d's `rt` -- and read_identity() already fetches the
resource, but kept only `n` and threw the rest away. No captured dump has
ever included it either: /device/0 batch responses don't carry /oic/d, and
diagnostics didn't report it, so there's no evidence on whether real
hardware populates it usefully.

Keep `rt` as DeviceIdentity.device_types, keep both raw payloads whole
(we don't yet know which of their fields identify a type), and surface
them in diagnostics so incoming issue reports answer the question.

Nothing routes on it yet.

/oic/d and /oic/p identify the unit with bare two-letter keys -- 'di' and
'pi' -- as sensitive as the serial number redact.py already covers but far
too short to match on: 'di' alone is a substring of 'condition', 'display'
and 'dispenser'. Add a whole-key match alongside the substring rules.
2026-07-29 01:56:52 +00:00
Jack Nagy 0ebcfb00ff fix: bind a fixed DTLS source port per device to evict stale sessions
When HA restarts without a clean DTLS close_notify (crash, host reboot),
the appliance keeps an orphaned DTLS association keyed to the client's
(IP, source port). Reconnecting from a fresh ephemeral port looks like a
new peer, so the device holds the orphan until its own timer reaps it,
which is 5 to 15 min on always-on appliances (fridges), during which the
new session's first reads hang. This is the root cause behind the repeated
"DTLS handshake timeout" reconnect storms on always-on devices (#119).

Bind a deterministic source port per device so every reconnect re-handshakes
over the same 5-tuple, which the device must treat as a rebooted peer and
evict the old association for (RFC 6347 §4.2.8). Recovery drops from a
device-timer wait to a single handshake.

The port must be stable across restarts and unique per device on the HA host
(the library socket is unconnected, so a shared source port would cross-
deliver datagrams). _local_source_port() uses the host's last IPv4 octet as
the offset from DTLS_LOCAL_PORT_BASE (unique on a /24), with a CRC32 fallback
for non-IPv4 hosts.

Requires smartthings-local >= 0.1.1, which adds DtlsCoapSession(local_port=).
The fix is backwards compatible upstream: local_port defaults to None
(previous ephemeral-port behaviour).

Root-caused and verified upstream in QuiteYellow/SmartThings-Local#14
(bench-verified on oven + dryer, field-verified on an always-on fridge
across repeated restarts).
2026-07-27 19:17:39 +01:00
Marc Billow fa8f1b8675 Add cool-only global RAC support: WindFree, Auto mode, display light
Finishes PR #91's contribution (pedroperosin) with the requested review
changes applied, on our own branch:

- Preset resolution is now fully dynamic, read from each unit's own
  /mode/convenient/vs/0 supportedModes instead of a static per-model
  table -- any board's convenient modes (including WindFree's Nano/
  NanoSleep) surface without code changes. Unlabelled codes across
  existing fixtures (longwind, motionindirect, motiondirect, drycomfort)
  plus the two new WindFree ones are added to en.json/nl.json.
- 'Auto' now maps to HVACMode.AUTO instead of HEAT_COOL: these are
  single-setpoint "device decides" units, not two-setpoint heat+cool
  ones. 'Fan' is added alongside 'Wind' as a second FAN_ONLY spelling;
  a new _device_code_for_hvac() picks the code from the unit's own
  supportedModes since the flat map can't disambiguate two device codes
  mapping to one HA value.
- Detection gains a hyphenated '-RAC-' modelNum fallback (alongside the
  existing '_RAC_') for cool-only global RAC variants whose
  /otninformation/vs/0 ships no swVersionInfo block.
- Adds a display_light switch sourced from /mode/vs/0's opaque options
  blob (inverted Light_On/Light_Off token) for boards with no dedicated
  /light/vs/0 switch.

Write-path behavioural change (touches the path iterated on across
#9/#17/#27/#38/#54): power now targets the vendor /power/vs/0 instead of
the OCF /power/0, and _is_on() reads vendor-first. /power/0 is absent on
several known AC boards, so the previous OCF-first read/write pair could
report and act on stale state -- consistent with #53's "can turn on but
not off". Target temperature now picks its channel (OCF pair vs. vendor
items[]) based on which the unit actually reports, reading and writing
the same one.

The vendor temperature write and the new display-light write both carry
only the changed field(s), not the whole resource -- confirmed sufficient
on the wire, the device merges the rest itself. That requires the
coordinator's optimistic cache to do the same merge on the read side so a
setpoint change doesn't blank out current/min/max/unit for the settle
window: common.py gains merge_items_field() next to the existing
merge_options_field(), and async_send_command wires it in for any write
touching x.com.samsung.da.items.

New fixture/golden for the cool-only global RAC variant (TP1X_DA-AC-RAC-
01001, AI_RAC_GLOBAL_COOLONLY_3.0); display_light added to the goldens
for boards that gain the new options-based switch. Regenerated against
current main rather than copied from the original PR, since those
goldens had already shifted (current_temperature_c/humidity from issue
#75).
2026-07-27 05:00:06 +00:00
Marc Billow ff6e1ecff4 Rename gas cooktop registry's display name to avoid induction_cooktop confusion
Renames DeviceRegistry.name from 'cooktop' to 'gas_cooktop' for the
NA9300K-class gas-cooktop registry (PR #23), so diagnostics/device-info
labels no longer collide with the unrelated induction_cooktop family
(issue #86) -- two different OCF surfaces that happen to share the
English word "cooktop".

Safe rename: _REGISTRY_BY_KEY's 'cooktop' lookup key is unchanged, so
all three existing detection paths (oneUiVersion "Cooktop" exact
match, the legacy ARTIK051 modelNum rule, and the resource-signature
fallback) keep routing real devices exactly as before. Entity
unique_ids are built from device serial + entity key, not registry
name, so existing entities are unaffected. Only the DeviceInfo.name
and diagnostics device_type strings change, both cosmetic.
2026-07-27 03:56:32 +00:00
Marc Billow d0e03b026c Merge pull request #99 from mbillow/claude/device-support-issue-83-fridge-detection
Catch the 'Nothing(SVC)' placeholder serial in both fallback sites (i…
2026-07-26 21:55:33 -05:00
Marc Billow 2c9fda3db1 Catch the 'Nothing(SVC)' placeholder serial in both fallback sites (issue #83)
The ARTIK051_DONGLE_REF firmware family reports the literal string
"Nothing(SVC)" as serialNum on every unit -- non-empty, so the existing
`if not serial` checks in config_flow.py's _probe_and_validate and
coordinator.py's _run_discovery don't catch it. Two such appliances on
one install (a fridge and a freezer, each its own dongle) then collide:
config_flow gives both the same unique_id and rejects the second as
"already configured" (bug 2), and even once that's worked around,
device_serial feeds every entity's unique_id too, so the second
appliance's entities get silently dropped with "does not generate
unique IDs" log lines (bug 4).

Add _is_placeholder_serial (duplicated in both modules rather than
imported, to avoid pulling config_flow into the runtime coordinator's
import graph or vice versa for a two-line check) and treat it the same
as an empty serial: fall back to host/port.

Type detection (bug 1) and the door sensor's field-name gap (bug 3),
also reported in this issue, are already fixed via the
claude/device-support-issue-77-freezer branch, which hit the same
ARTIK051_DONGLE_REF family from a different report -- not duplicated
here.
2026-07-27 01:00:05 +00:00
vmvarga 00cf8d676d feat: laundry firmware-flag gating, fridge vendor temp writes, course names 2026-07-25 10:01:56 +02:00
Hmmbob b85af10ae1 Test translation coverage and dynamic fallbacks 2026-07-24 18:08:29 +02:00
Marc Billow c731ecefe5 feat: add debug options panel for arbitrary resource-href writes (#54)
Power users can now pick a resource href from a live dropdown, view its
current value, and POST a minimal patch straight to the device -- to pin
down device-specific write behavior without waiting on a new release.
Bypasses the remote-control block and all write_fn/validate_fn logic by
design; the existing remote-control settings toggle moves behind the same
options-flow menu.
2026-07-24 14:02:15 +00:00
Marc Billow 037dc9722f feat: add options flow to bypass the remote-control write block per device (issue #54)
The remote-control-off write block was device-wide and unconditional:
whenever a device reports remote control off, every write is rejected
with a user-facing error, on the assumption the device would reject it
anyway. Issue #54 reports a washer where that assumption doesn't hold --
default detergent/softener dosing writes through even with remote
control off, since they apply to the built-in programs too, not just a
custom remote-controlled cycle.

Add a per-device options flow (Settings > Devices & Services > this
device > Configure) with a single toggle, stored in entry.options (not
entry.data) so it doesn't affect the device's identity/unique_id.
coordinator.async_send_command reads it ahead of the existing
remote_control_enabled() check; defaults to False everywhere, so devices
that don't touch this option see no change in behavior.
2026-07-24 03:32:49 +00:00
Marc Billow 85cca70b6b fix: don't let an in-progress settle window block a second write's own optimistic apply
Widening the settle window to tens of seconds (previous commit) made a
real gap much more likely to bite: apply() gated every source,
including 'optimistic', on _is_settling. /course/vs/0 backs several
independent washer selects (cycle, detergent quantity, softener
quantity, ...), so picking a second one while the first write's window
was still open -- routine within a ~43s window -- had its own
optimistic value silently dropped from the cache instead of shown,
recreating the exact "write doesn't seem to apply" symptom the guard
exists to prevent, just for whichever write lost the race.

Let source='optimistic' always bypass the gate; poll/sweep/observe
stay gated as before. mark_write_pending still re-arms the window
right after, so the newer write is protected going forward.
2026-07-24 03:14:58 +00:00
Marc Billow 020402c82f fix: size the write-settle window to outlast a slow-settling device (issue #9)
async_send_command's settle guard used DEFAULT_SETTLE_S's fixed few
seconds, which is long enough for fields that update instantly on the
device but not for ones that visibly take a few seconds of internal
validation or hardware movement to catch up. Issue #9's washer packs
cycle/detergent/softener selection into /course/vs/0's shared options[]
array, and that settling time regularly outlasted the fixed window --
same device, same integration, but /washer/vs/0's temperature/spin
fields (plain flags) confirmed instantly while these didn't. The short
window expired before the confirm poll (or the device itself) caught
up, so a stale read landed unprotected and reverted the optimistic
value, only to self-correct again once a later poll saw the real
change -- reading to the user as the write reverting and then
reapplying itself a few seconds later.

Size the window to always outlast the PUT and the confirming refresh's
poll combined, as issues #17/#53 also needed, but without that fix's
early-release mechanism (reverted previously for its own races around
overlapping writes) -- just hold the guard for the full window and let
it expire on its own.
2026-07-24 03:07:37 +00:00
Marc Billow 83bd158049 fix: apply the optimistic write to its actual target href, not the bound href (issues #17, #53)
An independent review turned up the real bug behind the climate lag:
async_send_command applied the optimistic value and settle guard to
bound_entity.href, but write_fn's path_segs -- the resource actually
POSTed to -- can point somewhere else entirely. The AC's composite
climate entity is bound to /mode/vs/0, yet a power/temperature/fan/
swing/preset command writes to its own sibling resource (/power/0,
/temperature/desired/0, ...), which is also what climate.py reads the
displayed state from. The optimistic value landed on /mode/vs/0
instead, so the resource the entity actually shows stayed stale until
the next unrelated read of it -- surviving the earlier optimistic-apply
fix (issue #27), which applied to the same wrong href.

Derive the write's target from path_segs and apply/guard/log against
that instead. Reverts the previous commit's settle-window-sizing
change on this branch: that was chasing a real but speculative edge
case (a confirm poll slower than the settle window) that a follow-up
review couldn't confirm matches the reported symptom, and its
early-release mechanism had its own races (a debounced refresh that
hadn't actually run yet, overlapping writes to the same href) for
marginal benefit once this fix lands. Simpler to drop it than carry
that risk for a case not in evidence.

Added a coordinator-level regression test against the real AC CLIMATE
capability (not just a synthetic mismatched-path descriptor) sending a
power command and asserting the optimistic value lands on /power/0,
not /mode/vs/0.
2026-07-23 22:42:04 +00:00