An independent review of the last two commits' diff turned up five real
problems and one CI-breaking one. Fixed all of them:
- tests/test_coordinator_error_handling.py assigned directly onto
coordinator instance attributes (coordinator._poll_once = dict), which
`ty check custom_components tests` -- what CI actually runs, not the
narrower `ty check custom_components` this branch had only been
spot-checked against -- flags as invalid-assignment. Switched to
monkeypatch.setattr, matching every other new test on this branch.
- coordinator.py's subdevice-enumeration failure comment claimed the
probe "retries naturally next cycle." It doesn't: _run_discovery sets
self._discovered = True unconditionally later in the same cycle, which
is what gates the whole block, so a failure here is a first-and-only
attempt, not a retried one -- a composite appliance's sibling
subdevices are missing for the config entry's lifetime until reload.
(A separate flag to retry wouldn't actually fix that either: every
platform's async_setup_entry enumerates coordinator.bound exactly
once, so a later-successful enumeration still couldn't add entities
without a reload.) Corrected the comment and raised debug to warning,
since the effect is silent and permanent otherwise.
- config_flow.py's new diagnostic-handshake fallback (_resolve_alert)
was being called once per failing candidate, inside _handshake_and_read's
scan loop -- contradicting _diagnostic_alert's own docstring ("only
runs once every real candidate has already failed"). Two real costs:
up to CLIENTHELLO_PROBE_TIMEOUT_S extra latency per failing port on
the sweep-fallback path (several candidates), and -- more seriously --
the diagnostic commits DTLS association state on each port it touches,
which can make _probe_and_validate's own CertRejected re-mint retry
(a fresh _handshake_and_read call against that same scan) time out
against the very port it just polluted, per the RFC 6347 §4.2.8
concern already documented elsewhere in this file. Moved to a new
_diagnose_failures helper called once, after the loop, against the
single best (confirmed-live) candidate.
- _resolve_alert also ignored the alert's level: ProbeResult.alert is
set for a received alert of either severity, but only a fatal one (2)
means the appliance broke off the handshake over it -- a warning
(e.g. close_notify) was being read as a rejection reason. Older
library exception text never had this ambiguity (OpenSSL only renders
an exception for a fatal alert), so this was a bug the redaction
fallback introduced. Now filters to level == 2.
- async_raw_read's new HomeAssistantError wrapper reported a translated
error but left a confirmed-dead session installed, so every
subsequent read/write would keep failing identically for up to the
next full poll interval. Now closes the session on any non-TimeoutError
failure, matching _poll_once's own posture.
- async_raw_write_sequence's verify_after fallback (vcode, vrep = 0, {})
is indistinguishable from a real 4.04 by raw_code alone. Added a
read_error field so a caller can tell "couldn't verify" from "the
device said no."
Tests: 8 new/extended (once-not-per-port diagnostic count, alert-level
filtering, the warning log + permanent-loss framing, session-closing on
both async_raw_read and the verify_after path, read_error surfacing).
Full suite (1527 tests), ruff, ruff format, and -- critically --
`ty check custom_components tests` (the CI-matching invocation) all pass.
Bumps the smartthings-local floor from >=0.1.2 to >=0.1.6 (manifest,
requirements-dev.txt, Dockerfile) and adopts the interface/behavior
changes introduced along the way:
- 0.1.3 ("redacted typed failures", PR #23) replaced connect()'s
ConnectionError(f"DTLS handshake error: {e}") with fixed, redacted
exceptions (SessionError, SessionTimeoutError, etc.) that never carry
backend text -- including the TLS alert name. The config flow's
_classify_handshake_failure relied on parsing that text out of the
exception (_alert_name) to tell a rejected certificate from any other
handshake failure; against a current library that regex never matches
again, silently downgrading every setup failure to the generic
"cannot_connect" message.
Fixed by adding _resolve_alert: it still tries _alert_name first (a
harmless fallback if it ever matches), then falls back to one bounded
smartthings_local.protocol.dtls_probe.diagnose_dtls_handshake() call
against the specific port that failed, which classifies the fatal
Alert straight from the raw record instead of an exception string.
_handshake_and_read now threads the resolved per-port alerts into
_classify_handshake_failure, so CertRejected vs. HandshakeFailed keeps
working the way it did before the redaction.
- 0.1.3 also moved the DTLS session onto a connected UDP socket (see
endpoint.py's open_connected_udp_socket), which changes why
coordinator._local_source_port needs a unique port per device -- the
kernel now demuxes by the full local-port/remote-peer tuple instead of
relying on an unconnected recvfrom(). Docstring updated to match.
- 0.1.6's reader-thread fail-fast fix (_check_live/_reader_running) makes
a dead reader raise SessionClosedError immediately instead of hanging
a request out to its timeout. No code change needed: SessionClosedError
is a ConnectionError subclass (not TimeoutError), so the coordinator's
existing _defer_reconnect_for/isinstance(e, TimeoutError) split already
routes it to the immediate-reconnect path.
Every other new/changed piece (endpoint.py, dtls_probe.py bounded
probing, auth.py's CertificateAuth/PskAuth providers) stays behind
compatible built-in exception types and unchanged get()/post()/
subscribe()/ping() signatures, per the library's own compatibility
table, so the coordinator's and observe.py's broad exception handling
needed no changes.
Tests: added coverage for _resolve_alert's exception-text vs.
diagnostic-handshake fallback, _classify_handshake_failure with a
resolved alerts mapping, and an end-to-end config-flow re-mint test
against a FakeSession that raises the new redacted SessionError instead
of the old text-bearing ConnectionError.
Full suite (1517 tests), ruff, and ty all pass against smartthings-local
0.1.6 installed from PyPI.
Flatten the store to {href: [codes]}. One href carries one LEARNABLE
rule, so keying the codes by the rule's supported field too let the
write side (rule.supported_field) and both read sides (the module-level
SUPPORTED_FIELD) disagree the moment a rule used a different field --
codes learned and persisted, then never offered.
The options flow's reset step read the persisted value raw in the
entry-not-loaded branch, so malformed data aborted the one screen that
can clear it; route it through LearnedModes like every other reader.
For the same reason forget_learned_modes() now persists whenever the
entry carries a record, not only when the in-memory store had one: a
record _coerce rejected at startup exists only on the entry.
Some firmware reports a current mode that is missing from the same
resource's supportedModes. An ARTIK051 air conditioner sits in Quiet
while advertising only [Off, Sleep, Speed, Nano, NanoSleep], so HA
showed preset_mode: quiet and then refused to select it. A second
reporter has three identical units where only the two sharing an
outdoor unit hide it, which rules out a real capability difference.
learned.py remembers any such code and the coordinator persists it on
the config entry, so a mode the device only names while it is active
survives a restart. climate._supported unions it into the resource's
own list, which fixes the read and the write together --
async_set_preset_mode reverse-resolves the device code from that same
list.
Learning is allowlisted per canonical href rather than global. Across
the fixture corpus 17 dumps already report a current mode that is not
in supportedModes: an oven idling in NoOperation, a fridge's
/mode/vs/0 carrying capability tokens like WATERFILTER_DISABLE. Those
are not selectable options, and remembering one permanently would put
an option in the UI that the device can only reject. Only
/mode/convenient/vs/0 is learnable today.
On by default, with a per-device option that stops offering and
learning at once, and a reset step in the options flow for a code that
turns out to be bogus. Diagnostics report what was learned separately
from `resources`, which stays exactly what the device said.
The options-flow "Debug write" panel could only ever do one write to one
href per pass -- not enough for the issue #300 wall oven, whose board
discards settings writes while idle and only keeps them once a cycle is
already running. Finding what starts a cycle needs an ordered sequence of
writes across resources, with real settle delays between them, and a way
to check afterward whether anything actually held.
- coordinator.py: async_raw_write_sequence owns a whole ordered sequence
under one _session_lock hold (so a poll can't interleave mid-sequence),
with per-step settle and an optional delayed verify_after re-read done
outside the lock. async_raw_write is now a one-item wrapper over it, so
tests/test_coordinator_raw_write.py keeps passing unmodified. Also adds
async_raw_read, a live GET bypassing the cache -- staleness is exactly
what makes revert-testing unreliable.
- services.py (new): the two HA services. Device-target resolution scans
loaded coordinators' MAIN/subdevice identifiers and requires exactly one
match, so an area/label target can't silently fan a raw write out across
several appliances. Canonical->actual href translation happens here, not
in the coordinator, which stays subdevice-agnostic.
- services.yaml (new): selectors/descriptions for both services, inline
per HA's custom-integration support -- keeps translations/en.json's
mirror test (test_translations.py) green without touching all 6
languages for a services block. New exception keys (write caps, device
target resolution) still went into translations/*.json's existing
exceptions section, mirrored across all 6 languages.
- __init__.py: adds async_setup to register the services once, process-wide.
- config_flow.py: the debug panel's async_step_debug_edit now calls
write_resource instead of coord.async_raw_write directly, so there is
exactly one code path that performs a raw write.
- README.md: new Part 5 documenting both services, with a worked
write_resource example; points the capability-gap section at them.
tests/test_services.py (new): sequencing/ordering, settle timing, changed
vs. held (the reverted case is issue #300's own symptom), exactly-one-
device resolution, subdevice href translation, validation caps, and the
options-flow panel end to end through the service.
A PEM pasted from a text editor can carry bytes cryptography's parser
refuses outright: a UTF-8 BOM some Windows editors silently prepend,
CRLF line endings, and a stray blank line a paste can introduce
between the header/body/footer. None of those are meaningful in PEM,
but any of them surfaces as an opaque InvalidHeader with no hint of
what's wrong -- which is why the same certificate pasted from
Command Prompt's `type` (no BOM, no stray blank lines) loads fine
while the same file opened in an editor and copied doesn't (issue
#291).
Normalize at the point the pasted blob is first captured, not just
before minting the leaf cert: the same string is stored in the config
entry and reused to re-mint the leaf on a future reconfigure, so a
raw copy would keep failing every time it's read back, not just on
the first attempt.
Adding a device had one message for nearly every way it could fail: "Cannot
connect to the device. Verify the IP address is reachable and the CA
credentials are correct." That covers an IP with nothing on it, an
appliance on cloud-only firmware, a device still holding the session from
the last attempt, a device that answered and rejected our certificate, and
Home Assistant having no internet to reach Samsung's cloud. Only one of
those is fixed by checking the IP and the CA credentials, and the message
gave no way to tell which one you had.
The probe already gathers enough to tell them apart, so classify it:
- cert_rejected the appliance sent a certificate alert. The CA
credentials aren't the AC14K_M CA it trusts, or they
don't pair. Far and away the most common real setup
mistake, and previously indistinguishable from a typo
in the IP address.
- handshake_failed a fatal alert unrelated to the certificate (protocol or
cipher mismatch) -- no amount of fiddling with CA
credentials will fix it.
- handshake_timeout the ClientHello probe proved a DTLS server is right
there, but the handshake never finished. Usually the
appliance is still holding the association from a
previous attempt; it clears on its own in about a
minute.
- ports_closed ICMP port-unreachable on the whole range: something is
at that address and it isn't exposing a local API.
Cloud-only firmware (TCP 8888 only) lands here.
- no_dtls_server some ports open|filtered, none speaking DTLS -- likely
another device on that IP.
- no_response nothing came back at all.
- cloud_unreachable couldn't reach Samsung's cloud gateway for the UUID.
An internet problem on HA's side, not the appliance's.
- unexpected_response authenticated fine, then returned something we can't
read. Neither connectivity nor credentials.
Certificate alerts are read back out of the error text OpenSSL puts in
DtlsCoapSession's ConnectionError, not by re-probing. The library's
diagnostic probe would report the alert authoritatively, but it drives the
handshake far enough to commit association state on the device -- and an
orphaned association is exactly what makes the *next* attempt time out
(RFC 6347 4.2.8), which is a bad trade on a path the user is about to
retry.
Telling ports_closed from no_response needs the UDP sweep to separate a
refusal from an unreachable. Both leave a port "not live", but ECONNREFUSED
is a *response* -- the host is there -- while EHOSTUNREACH/ENETUNREACH mean
the datagram never left. A wrong IP on the local subnet never answers ARP
and fails every send that way, so treating the two alike would have told
those users their appliance was on cloud-only firmware. The sweep now
returns live/refused/unreachable separately, and the preferred-port rescue
moved out of it into _sweep_ports: the rescue is a candidate-selection
decision, and folding it into the sweep's verdict destroyed the evidence
the message is built from.
Every failure carries the error key that fits it, so the flow maps
exceptions instead of guessing, and logs the specifics (alert name, per-port
outcome, response code) at warning level -- the messages that mention the
log now have something to point at.
Certificate re-minting for a reused leaf is also narrower and more correct
as a result: it now triggers on CertRejected specifically, rather than on
"every attempt raised ConnectionError and a port was confirmed".
All five translation catalogs carry the eight new messages. The non-English
ones are my own work rather than a native speaker's; corrections welcome.
Two problems, one setup path.
Port detection (issue #211): the config flow found the DTLS port by
elimination -- a 1-byte UDP probe can't tell a silent port from a real
DTLS server, so every port it couldn't rule out got a full certificate
handshake, and every false positive cost the whole 12s HANDSHAKE_TIMEOUT_S
before the next was tried. Adding an appliance took 30-40s.
smartthings-local 0.1.2 ships a stateless ClientHello probe that settles
this positively: a real DTLS server answers with a HelloVerifyRequest in
~1 RTT, and per RFC 6347 4.2.1 it does so without allocating association
state, so the probe leaves nothing behind on the appliance. The whole
49152-49160 range is probed at once and exactly one confirmed port is
given a certificate handshake. Fanning out is safe here in a way racing
real handshakes is not -- each probe is bounded by a 3s budget, so the
pool costs one probe's wall clock rather than the sum of the range, with
no losing threads left running behind us.
The UDP sweep stays as the fallback for when the probe confirms nothing:
it errs in the opposite direction (it reports everything it can't rule
out), so it still surfaces a device on a path that eats our ClientHello,
and it keeps its issue #192 preferred-port rescue.
Port detection now runs first and needs no credentials, so an unreachable
host fails before any round trip to Samsung's cloud. And a second
appliance reuses the existing entry's leaf cert rather than re-minting --
every device accepts the same one -- which makes adding one independent
of Samsung-cloud reachability. A confirmed-live device rejecting the
reused leaf (the UUID does rotate) re-mints and retries once, so reuse
stays self-correcting; a timeout doesn't, since a fresh cert can't fix
nothing answering.
Identity (issue #236): the coordinator seeded device_serial with the
configured host and only replaced it after the first successful poll. But
device_serial mints *permanent* registry keys -- entity unique_ids and
device identifiers -- so anything registering before that poll returned
was written into the registry keyed on the IP address forever. The
connection-mode sensor is added unconditionally rather than from `bound`,
so it was the reliable victim: when the serial-keyed identity appeared
moments later HA created a second device and entity, and the IP-keyed
pair was orphaned. Deleting them didn't help; the next restart that lost
the race recreated them.
The probe already learns the identity, so store it on the config entry --
serial, model, manufacturer, device type. The coordinator seeds
device_serial and its DeviceInfo from those at construction, so keys are
correct from the first entity that registers even if the first poll is
slow or fails outright. There is no placeholder left to correct.
Discovery now treats the registered identity as authoritative rather than
re-keying a device that already has registry entries; it adopts and
persists the polled identity only for an entry that has none, and warns
if a different appliance answers on the same IP.
Entry version 1 -> 2 recovers the serial from the entry's unique_id (the
flow has always keyed it on the probe's serial) and repairs what the old
registration orphaned: IP-keyed devices and entities are rewritten in
place where the serial-keyed key is free -- keeping entity_id, name, area
and every automation referencing them -- and removed where both exist,
since the IP-keyed one has been dead since the restart that made it.
Placeholder-serial boards (issues #83/#189) were keyed two ways at once,
`host:port` on the entry and `host` in the registry; migration collapses
the entry onto the registry's form. One resolve_serial() now serves both
sides, so they can't drift apart again.
The remaining step in the desired pipeline -- probe for subdevices, then
register devices, then populate entities -- already holds:
_enumerate_subdevices_blocking runs before _run_discovery, which runs
before platforms are forwarded. Duplicating it in the config flow would
mean re-running Pattern B's per-href fallback probe, which is the
opposite of what issue #211 is about.
Completes the isinstance/cast narrowing + Optional-field assert pattern
across the last batch of test files. custom_components and tests are
now both fully clean under ruff check, ruff format --check, and ty check.
Same isinstance/cast narrowing and Optional-field assert pattern as the
prior commits, covering the airconditioner, fridge, washer, operational,
subdevices, sensor_hysteresis, laundry, select_options, identity and
entities test files.
Adds [tool.ruff] and [tool.ty] config to pyproject.toml with a curated
ruff rule set (E, F, W, I, UP, B, C4, SIM, RUF, ASYNC, LOG, G, PIE, RET,
PERF, N), pins ruff/ty in requirements-dev.txt, reformats the whole tree
with `ruff format`, and fixes the pre-existing lint and type-check debt
those tools surfaced so both run clean.
Production-code type fixes include: HA's ConfigFlowResult vs. the
generic FlowResult in config_flow.py, narrowing BoundEntity.desc to its
platform-specific subclass (SelectDesc/NumberDesc/SensorDesc/etc.) via
cast() instead of an unchecked annotation, converting HA device_class
strings to their proper enum types, a resolve_registry callback typed
as `object` instead of `DeviceRegistry | None`, and a couple of other
narrow correctness fixes (CA key type validation, an index-out-of-bounds
false positive from an empty-tuple fallback, a bool/dict argument swap).
Test-file fixes are mechanical: narrowing SamsungEntityDescription to
the correct subclass via isinstance()/cast() before accessing
subclass-only fields, and asserting Optional write_fn/unit_fn fields
are set before calling them.
_is_placeholder_serial only caught the ARTIK051_DONGLE_REF family's
'Nothing(SVC)' sentinel. The DA_WM_A51_20_COMMON (ARTIK051) laundry
board family reports a different one instead -- every character the
same repeated hex digit -- which passed through as a real, non-unique
serial. Two different physical units (a washer and a dryer) both
reporting the literal serialNum 'FFFFFFFFFFFFFFF' collided on the
config-entry unique_id, so the second device's config flow aborted as
already configured. Widen the check (both the config_flow.py and
coordinator.py copies) to also catch that sentinel shape.
- config_flow: the #192 port-rescue made the "every port refused" fast-fail
permanently unreachable (PREFERRED_PROBE_PORTS is always non-empty and
always rescued), so removed the dead branch instead of leaving it as
misleading dead code. A dead host now fails via the handshake loop's own
error, which carries the real per-port reason.
- oven._has_option: added the is_stub_rep carve-out cooktop.py's identical
per-token exists_fn already has on the same kind of href, so a not-yet
sub-polled /mode/vs/0 doesn't permanently exclude energy_saving/
cooktop_on_alert before their first real fetch lands.
- airconditioner.ENERGY_METER_LEGACY: build via dataclasses.replace() like
its ENERGY_METER_GENERIC sibling, instead of hand-copying href/poll_tier
(which would silently drift if common.ENERGY_METER ever gains a field).
- Fixed two stale comments: is_legacy_board()'s docstring still listed
Volume among tokens needing legacy-only gating, though 'beep' now applies
unconditionally across board generations; and common.py's UNIVERSAL
invariant comment didn't mention that airconditioner also now excludes
ENERGY_METER from the wholesale bundle.
- #191 (CAC token): added the fixture/golden/capability-test coverage the
AVT token in the same branch got, including an honestly-documented list
of the ten hrefs this board generation doesn't cover yet.
- fridge.cooler_temperature_setpoint: dropped the hardcoded "N °C" state
labels -- the resource's own unit field isn't necessarily Celsius on a
different model reporting the same href, and the options themselves are
already read live via options_field, so a static per-value label risked
asserting the wrong unit for a future device sharing this capability.
- airconditioner._legacy_cumulative_power_kwh: parse with float (matching
common.wh_to_kwh's own numeric parsing) instead of this module's
integer-only _int, so a decimal-formatted reading doesn't raise.
- test_config_flow: the port-rescue test bound the real 49154 directly,
which could collide with an actually-running service on some machine;
now monkeypatches PREFERRED_PROBE_PORTS to an OS-assigned port instead.
- oven.py: consolidated six byte-for-byte-identical single-token options
write_fns (lamp/sound/fast_preheat/natural_steam/energy_saving/
cooktop_on_alert) into one _option_switch_write(prefix) factory.
845 tests passing (up from 841 -- 4 new CAC coverage tests).
The liveness sweep's ICMP-based verdict isn't trustworthy on every network
path -- a segregated-VLAN report showed it calling three closed ports live
while missing the one port a concurrent nmap scan found genuinely
open|filtered, which also happened to be one of our two historically
confirmed DTLS ports. Rather than trust a "not live" verdict against that
prior, always give PREFERRED_PROBE_PORTS a real handshake attempt even when
the sweep excludes them, bounded to at most those two extra attempts.
This is a stop-gap for the reported failure mode, not a full fix for the
sweep's underlying unreliability -- left a comment on the issue with the
diagnosis and flagged the sweep itself for a deeper redesign.
oneUiVersion looks like the signal you'd want -- the device naming its own
type, '7.0 Dishwasher' -- and it was the first thing detection consulted. It
never earned the position:
- Only 7 of 49 fixtures report it at all.
- All 7 resolve to the same registry from their modelNum board token alone.
- No device-support issue has ever been fixed by adding a mapping for it.
Every one went through modelNum. The alias keys it needed in
_REGISTRY_BY_KEY ('airpurifier', 'air_conditioner', 'hood') were
speculative when the registries were first written and never used since.
So it bought a key-normalizing helper (_type_key), a lookup with a suffix
fallback (for_device), three alias keys, and a second config-flow step whose
only reason to exist was phrasing a sentence about oneUiVersion -- for a
signal that has never once been decisive.
Remove it from detection. It stays in diagnostics, where it's genuinely
useful: it names the firmware generation ('7.0 Air conditioner' is Tizen
Lite), which matters when triaging an issue.
Detection order was also duplicated in four places -- the coordinator, the
config flow's probe, the golden-regression harness, and the skill -- which
is how the harness and the shipped order drift apart. Collapse it into
by_type.resolve(resources), and call that everywhere.
The two "appliance type not recognized" config steps become one. They
differed only in whether they blamed a missing oneUiVersion, which is not a
distinction a user can act on, and never was.
Verified by the full suite (795 passing), including every golden regression
-- so entity output is byte-identical for all 49 device fixtures.
TestOneUiVersionIsNotConsulted locks in the premise rather than just the
outcome: for every dump that reports a oneUiVersion, the model strings alone
must still reach a registry. If a future device breaks that, the test says
so instead of the device silently losing half its entities.
Also note in requirements-dev.txt that Python 3.13 resolves the pinned
harness floor -- 3.12 and older resolve nothing and fail the whole install.
The ARTIK051_DONGLE_REF firmware family reports the literal string
"Nothing(SVC)" as serialNum on every unit -- non-empty, so the existing
`if not serial` checks in config_flow.py's _probe_and_validate and
coordinator.py's _run_discovery don't catch it. Two such appliances on
one install (a fridge and a freezer, each its own dongle) then collide:
config_flow gives both the same unique_id and rejects the second as
"already configured" (bug 2), and even once that's worked around,
device_serial feeds every entity's unique_id too, so the second
appliance's entities get silently dropped with "does not generate
unique IDs" log lines (bug 4).
Add _is_placeholder_serial (duplicated in both modules rather than
imported, to avoid pulling config_flow into the runtime coordinator's
import graph or vice versa for a two-line check) and treat it the same
as an empty serial: fall back to host/port.
Type detection (bug 1) and the door sensor's field-name gap (bug 3),
also reported in this issue, are already fixed via the
claude/device-support-issue-77-freezer branch, which hit the same
ARTIK051_DONGLE_REF family from a different report -- not duplicated
here.
Power users can now pick a resource href from a live dropdown, view its
current value, and POST a minimal patch straight to the device -- to pin
down device-specific write behavior without waiting on a new release.
Bypasses the remote-control block and all write_fn/validate_fn logic by
design; the existing remote-control settings toggle moves behind the same
options-flow menu.
The remote-control-off write block was device-wide and unconditional:
whenever a device reports remote control off, every write is rejected
with a user-facing error, on the assumption the device would reject it
anyway. Issue #54 reports a washer where that assumption doesn't hold --
default detergent/softener dosing writes through even with remote
control off, since they apply to the built-in programs too, not just a
custom remote-controlled cycle.
Add a per-device options flow (Settings > Devices & Services > this
device > Configure) with a single toggle, stored in entry.options (not
entry.data) so it doesn't affect the device's identity/unique_id.
coordinator.async_send_command reads it ahead of the existing
remote_control_enabled() check; defaults to False everywhere, so devices
that don't touch this option see no change in behavior.
The suite was never run in CI (only hassfest/HACS), and requirements-dev
listed only pytest + smartthings-local while conftest.py needs the full
Home Assistant test harness.
- requirements-dev.txt: add pytest-homeassistant-custom-component (pulls
in home-assistant + pytest + pytest-socket) and the integration's
runtime deps (cbor2, pyOpenSSL, cryptography) needed to import it.
- .github/workflows/validate.yml: add a Pytest job on Python 3.14
(current Home Assistant's floor) that installs requirements-dev and
runs the suite.
- test_config_flow.py: the UDP liveness-sweep test needs real loopback
sockets, which the HA harness blocks by default; take the pytest-socket
socket_enabled fixture so it runs instead of erroring.
Full suite: 249 passed.
The config flow only probed 49154/49155, so appliances whose local
CoAP/DTLS API binds elsewhere in the ephemeral range (e.g. a dishwasher
answering on 49153) could never be added.
Add a fast UDP liveness sweep across 49152-49160 that uses the ICMP
port-unreachable / ECONNREFUSED asymmetry to find the live port(s)
before attempting the expensive DTLS handshake. Closed ports fall out
immediately; a live-but-silent port is kept as a candidate. The real
handshake then runs only against discovered ports, preferring the
historically known 49154/49155 when several look live.
Also drop the probe's /device/0 GET deadline from a bare 15s literal to
a named PROBE_GET_TIMEOUT_S constant (10s) — the slowest observed full
dump is ~8s, and 10s matches the per-resource read timeout used
elsewhere.
Bumps version to 0.5.0.
Completes the device-capability-diagnostics spec:
- diagnostics.py: the standard HA diagnostics hook, returning device type,
one_ui_version, unbound hrefs, and the redacted raw resource tree, plus
integration and smartthings-local version numbers. This is what the
Repairs issue (added in the previous commit) points users at, and what
they attach to a device-support issue.
- config_flow.py: _probe_and_validate now also reports oneUiVersion and
whether the device type is recognized. Recognized types are unaffected;
an unrecognized type shows a new confirm_unknown_type step explaining
that only common capabilities will be available before creating the
entry, so expectations are set at setup time rather than only after the
fact via Repairs.
- .github/ISSUE_TEMPLATE/device-support.yml: structured template for
filing a capability gap, linked from both the Repairs issue and the
config-flow confirmation step.
- README: short section pointing at this whole mechanism.
- Add button platform (button.py + PLATFORMS) so oven/washer Start/Pause/Stop
controls actually appear in HA
- Load DTLS cert chain from memory via _load_pem_chain(); eliminate all temp
file writes for key material in config_flow and coordinator
- Fix PEM boundary: ensure leaf and CA blocks are separated by a newline in
the stored fullchain regardless of whether the user pasted a trailing newline
- Dryer mode select: add static options tuple and value_fn to decode Course_XX
hex strings back to human names; was permanently empty before
- Remove callable branch from LocalThingsSelect (options_field covers dynamic
case; callable contract was broken — called with no args vs Callable[[dict]])
- Guard native_min/max_value overrides with hasattr + super() fallback to
prevent AttributeError when native_min=None and range_field returns nothing
- Add async_close() public method to coordinator; __init__ now calls it instead
of reaching in to _close_session directly
- Update tests: rename CONF_CERT_PEM/KEY_PEM → CA/LEAF variants, add
leaf_cert_pem/leaf_key_pem to mock_probe return, fix mock PEM constants
(no trailing newlines, matching what .strip() stores)