The OutdoorTemp_ options token was only surfaced on legacy boards
(is_legacy_board), even though 14 of 17 fixtures carrying the token are
non-legacy. issue #367 confirmed with a 48h field capture (r=0.92
against weather.forecast_home) that the token tracks real outdoor
temperature independent of board generation, and that no non-legacy
board exposes an alternative outdoor-temperature resource.
Split a token-presence-only exists_fn (_has_option_token_any_board) for
this token, leaving _has_option_token's legacy gate untouched for the
other options[] settings that still need it. Ships enabled_default=False
since multi-split installs report the same token on every indoor head,
which would otherwise create one duplicate active sensor per head.
Updates the golden fixtures for the 14 affected boards and the
artik051_krac test that had asserted outdoor_temperature stays off
newer boards.
`/option/autoclean/vs/0` carries three fields and only `settingStatus` was read.
That one says the feature is enabled, which it is whether or not the unit is
drying right now, so nothing reported an actual cycle.
settingStatus: On <- the existing auto_clean switch
status: Stop supportedStatus: [Start, Stop]
progress: 0
Adds a binary sensor for `status` and a percentage sensor for `progress`.
Measured on a TP1X_DA-AC-CAC-01001, sampling the resource every eight seconds
across a cycle: `Start` with progress 98 while it ran, then `Stop` with progress 0
the moment it finished. The percentage matches the figure the appliance shows on
its own display, checked against 55% mid-run.
Golden state keys updated for the 18 fixtures that bind AUTO_CLEAN. The change is
additive — no key was removed from any of them.
Full suite passes (1070 tests, Python 3.13 via requirements-dev.txt).
mbillow's follow-up review: exposing read-only Software/Firmware (and
Outdoor/Touch IC) version strings is "data for the sake of exposing it" --
no user control, just clutter, and every other registry leaves
/information/vs/0 in the global ignore as identity plumbing. Conforming to
that stance rather than expanding the entity surface for no user story.
- by_type/airconditioner.py: revert to *ignored.IGNORED (no _IGNORED_LESS_INFO
filter); drop airconditioner.INFO from the registry.
- capabilities/airconditioner.py: remove the INFO capability, the _info_version
/_info_items_of_type /_has_info_version helpers, and HREF_INFORMATION.
- translations/{en,nl}.json: drop software_version, firmware_version,
firmware_version_2/3, outdoor_unit_version, touch_ic_version.
- tests: drop the six INFO tests; golden regenerated for 8 AC + dehumidifier.
625 tests pass.
Per mbillow's review on PR #129 (CHANGES_REQUESTED). Items 1-7 + smaller.
1. INFO: expose each /information/vs/0 version item per (type, ordinal) instead
of collapsing to a single first-Firmware value. Boards carry 1-3 Firmware
items (separate MCUs) plus an Outdoor unit and (window AC) a Touch IC item;
each is a distinct version string. _info_version(items, type_, ordinal)
+ _has_info_version exists_fn gate, so an item with no number (tp2x_rac_20k's
second Firmware) suppresses the entity rather than binding unknown.
2. air_filter_threshold is locally writable, not cloud-only -- confirmed live
on ARTIK051_PRAC: POST filterDesiredUsage=700 to /filter/airdustfilter/vs/0
-> 2.04, read-back 700, persists; restored to 500. Converted from a
read-only sensor to a SelectDesc keyed to the device's
supportedFilterDesiredUsage enum (options_field), with a write_fn that
POSTs the scalar field. Only binds where the enum is advertised; boards
without it leave this writable field unexposed rather than guess the valid
set (don't-guess).
3. air_filter_usage_hours uses unit_fn reading filterCapacityUnit ('Hour'->'h')
instead of a hardcoded unit, so a board advertising a different unit doesn't
mislabel a duration statistic.
4. air_filter_usage_hours state_class is total_increasing, not measurement --
filterUsage is a lifetime hour counter that resets on filter replacement.
5. INFO and air_filter_threshold now carry exists_fn (AIR_QUALITY already did),
so they don't bind a permanently-unknown entity when their item/field is
absent. Also fixes the caww_tp2 golden nuance (filterDesiredUsage absent
-> no threshold key, matching what HA would actually create).
6. AIR_QUALITY: CleanLevel is corroborated as numeric by a top-level
x.com.samsung.da.cleanLevel scalar (tp1x_da_ac_rac_01011 reports both as
'1'), so clean_level is now an int measurement; odor/dust/fine_dust stay
string diagnostics. Reinstated the 2-element-array ambiguity note (Dust/
FineDust/SuperFineDust report ['0','0']; v[1] meaning unconfirmed, v[0]
taken as the reading). SuperFineDust is now modeled for consistency with
Dust/FineDust (same shape), rather than skipped without reason.
7. _beep_write restores the last non-Mute Volume level on 'On' instead of
forcing Volume_100, so an intermediate setting (e.g. Volume_50 set via
the cloud) survives an off/on cycle; falls back to 100 when no prior level.
Smaller: test_air_quality now asserts the tp1x_da_ac_rac_01011 clean_level==1
non-zero reading (the one value_fn-regression catch in the corpus); renamed
by_type's _AC_IGNORED -> _IGNORED_LESS_INFO to resolve the two-meaning
collision with the capabilities module's _AC_IGNORED (href strings); golden
regenerated for the 8 AC fixtures + dehumidifier.
612 tests pass.
Layer the ARTIK051_PRAC additive entities onto the upstream registry on a
fresh branch (additive-only; the round-1 display-light/mute-once/WindFree
work was independently shipped upstream and is not redone here).
New entities, all driven by single-token option_write or item reads:
- beep (switch): Volume_Mute/Volume_100 option token; single-token merge --
a full options RMW reverts on ARTIK051_PRAC. Cloud counterpart:
samsungce.airConditionerAudioFeedback (on/off only; level is cloud-only).
- tropical_night_mode (number 0-16): Sleep_<N> option token. Cloud:
custom.airConditionerTropicalNightMode.
- air_filter_usage_hours / air_filter_threshold (duration sensors, h):
raw filterUsage count and filterDesiredUsage alarm threshold. Threshold
SET is cloud-only (samsungce.dustFilterAlarm); local read-only.
- clean_level / odor / dust / fine_dust (diagnostic sensors): /sensors/vs/0
items[]. No unit advertised on the resource, so no device_class until a
populated reading + unit is observed (don't-guess rule). SuperFineDust
intentionally not modeled.
- software_version / firmware_version (diagnostic sensors):
/information/vs/0 items[]. The href is globally ignored as identity
plumbing; the AC registry drops that ignore so INFO is the sole cap on it.
Translations: en.json + nl.json (every-language-mirrors-english invariant).
Golden regression: regenerated the 8 AC fixtures + dehumidifier (reuses
AIR_FILTER) for the new state keys.
608 tests pass.
Finishes PR #91's contribution (pedroperosin) with the requested review
changes applied, on our own branch:
- Preset resolution is now fully dynamic, read from each unit's own
/mode/convenient/vs/0 supportedModes instead of a static per-model
table -- any board's convenient modes (including WindFree's Nano/
NanoSleep) surface without code changes. Unlabelled codes across
existing fixtures (longwind, motionindirect, motiondirect, drycomfort)
plus the two new WindFree ones are added to en.json/nl.json.
- 'Auto' now maps to HVACMode.AUTO instead of HEAT_COOL: these are
single-setpoint "device decides" units, not two-setpoint heat+cool
ones. 'Fan' is added alongside 'Wind' as a second FAN_ONLY spelling;
a new _device_code_for_hvac() picks the code from the unit's own
supportedModes since the flat map can't disambiguate two device codes
mapping to one HA value.
- Detection gains a hyphenated '-RAC-' modelNum fallback (alongside the
existing '_RAC_') for cool-only global RAC variants whose
/otninformation/vs/0 ships no swVersionInfo block.
- Adds a display_light switch sourced from /mode/vs/0's opaque options
blob (inverted Light_On/Light_Off token) for boards with no dedicated
/light/vs/0 switch.
Write-path behavioural change (touches the path iterated on across
#9/#17/#27/#38/#54): power now targets the vendor /power/vs/0 instead of
the OCF /power/0, and _is_on() reads vendor-first. /power/0 is absent on
several known AC boards, so the previous OCF-first read/write pair could
report and act on stale state -- consistent with #53's "can turn on but
not off". Target temperature now picks its channel (OCF pair vs. vendor
items[]) based on which the unit actually reports, reading and writing
the same one.
The vendor temperature write and the new display-light write both carry
only the changed field(s), not the whole resource -- confirmed sufficient
on the wire, the device merges the rest itself. That requires the
coordinator's optimistic cache to do the same merge on the read side so a
setpoint change doesn't blank out current/min/max/unit for the settle
window: common.py gains merge_items_field() next to the existing
merge_options_field(), and async_send_command wires it in for any write
touching x.com.samsung.da.items.
New fixture/golden for the cool-only global RAC variant (TP1X_DA-AC-RAC-
01001, AI_RAC_GLOBAL_COOLONLY_3.0); display_light added to the goldens
for boards that gain the new options-based switch. Regenerated against
current main rather than copied from the original PR, since those
goldens had already shifted (current_temperature_c/humidity from issue
#75).
Three gaps reported against an ARTIK051_PRAC_20K WindFree unit vs. the
SmartThings integration:
1. Missing WindFree/motion convenient-mode presets -- left alone here.
PR #91 replaces climate.py's static _DEVICE_TO_PRESET table with a
generic resolver that reads any preset code straight off the unit's
own supportedModes, which already covers this (and more generically
than a per-model dict would) -- adding one here would just conflict.
2. No horizontal oscillation: /wind/direction/vs/0's supportedModes
includes Left_And_Right, which _DEVICE_TO_SWING had no mapping for.
Add it to HA's standard 'horizontal' swing constant.
3. No standalone humidity/current-temperature sensors: the climate card
already reads both internally, but nothing exposed them as entities
for history/automations. Add CURRENT_TEMPERATURE (OCF
/temperature/current/0) with a CURRENT_TEMPERATURE_VS vendor fallback
(same match_fn-gated pair shape as common.py's POWER_GENERIC/
POWER_VS_FALLBACK), and a HUMIDITY sensor reading /humidity/vs/0's
fivepercentHumidity field -- the only one of the three
humidity-shaped fields across /humidity/0 and /humidity/vs/0 that
isn't permanently stuck at 0 on every dump seen.
Regenerates the five existing AC goldens (all pick up
current_temperature_c; most pick up humidity) and adds a dedicated
fixture from the issue's WindFree dump, whose /humidity/vs/0 actually
has live fivepercentHumidity data.
New '-CAWW-' modelNum token for multi-indoor-unit commercial AC
installs -- these report no oneUiVersion, same as the other RAC/PRAC
boards. Once routed to the existing airconditioner registry, every
resource in the reporter's dump already binds except one new
SAC-specific installation-topology blob, now ignored.