Commit Graph
5 Commits
Author SHA1 Message Date
Marc Billow 33786ad584 Distinguish not-yet-fetched stub reps from confirmed-empty ones (issue #127)
parse_device0_batch used to collapse /device/0's {"href": "..."} "no data
yet" marker into a plain {}, indistinguishable from a resource the device
had actually polled and confirmed empty. Every exists_fn using the "not
rep or ..." stub carve-out (and entity._is_included's default field-gate)
then treated both the same way, creating phantom always-"unknown" entities
for any resource a model simply doesn't support (e.g. GSzabados's fridge's
/energy/consumption/vs/0).

is_stub_rep() now recognizes only the literal {"href": ...} marker as a
stub; a genuine {} is treated as the device's real (if empty) answer and
gates the entity off like any other missing field. Updated the energy
meter, self-check error, cooktop burner, and range-hood auto-operation
exists_fn call sites, plus three golden fixtures that had baked the
phantom-entity behavior in as "expected".
2026-07-28 02:57:30 +00:00
Marc Billow 2be742489b Fix airflow fan power-href preference and unique_id collision risk
Opus review of the previous commit caught two real bugs. The airflow fan's
power writes preferred /power/vs/0, copied from the TP1X fan class -- but
that order is only harmless there because TP1X never reports /power/0 at
all. This family's dumps carry both hrefs, and the power_switch entity is
unconditionally bound to /power/0 when present, so the fan was writing to
a different resource than power_switch reads/writes, leaving the two
entities disagreeing until the next poll. Flipped to prefer /power/0,
matching the range hood's fan and common.POWER_GENERIC.

Also renamed the new FanDesc's key from 'fan' to 'airflow_fan': BoundEntity
unique_ids are derived from key alone, not href, so it collided with
air_purifier.FAN's own 'fan' key on the (currently unobserved, but
unenforced) possibility of a board reporting both.

Added a platform-level test file covering the power-href preference and
percentage<->speed-code mapping, mirroring test_range_hood_fan.py's harness.
2026-07-27 21:48:23 +00:00
Marc Billow d4583b3240 Add real fan-speed control for ARTIK051_TVTL air purifiers (issue #56)
/airflow/0's speed was left read-only because the first round of diagnostics
wasn't conclusive (0 for both Auto and High, 3 for Low/Medium and Sleep) --
likely because all five dumps were captured within about a minute of each
other, faster than this integration's own poll cycle could settle each
change. A second round, captured 60-90s apart per setting on two independent
units, confirmed a clean monotonic 0-4 mapping across Auto/Sleep/Low/Medium/
High instead.

Builds an ordered-speed fan off that confirmed range, the same SET_SPEED
shape as the range hood's fan -- this board never self-reports a
supportedModes-style label list, so there's no named-preset table to
preserve, just percentage steps over the raw code. /airflow/vs/0's vendor
speedLevel stays a read-only fallback since it was unreliable in that same
second round.
2026-07-27 21:32:44 +00:00
Marc Billow 39dcf6a7b8 Drop unexplained Blooming_* diagnostic, confirm remaining air purifier fields (issue #56)
Per the five running-state diagnostics dumps (Auto/Sleep/Low/Medium/High)
gathered in the issue thread:
- Blooming_* has no corresponding SmartThings app setting, so it's dropped
  entirely rather than kept as an unexplained diagnostic.
- Comode_* reads 'Off' on all five, ruling out the original guess that it
  was the fan-speed selector -- still exposed read-only, purpose unconfirmed.
- OptionCode_60282 and the missing humidity sensor are confirmed correct as
  already modeled.
- /airflow's speed doesn't map monotonically to the five settings and the
  dumps were all captured within one ~30s poll cycle of each other, so it
  stays read-only pending a cleaner, time-spaced capture.

FilterProgress is untouched here: an earlier pass on this issue read the
thread as confirming 100 means "fresh" and renamed the sensor to filter_life
to match, but that reading was backwards -- the reporter clarified 100
means fully used and needs replacing, which is what filter_progress (the
already-shipped name) already implies. That rename was caught before
merging and is not part of this change.
2026-07-24 04:20:42 +00:00
Marc Billow b121d24966 Add Samsung air purifier support (ARTIK051_TVTL-class, issue #56)
Adds a by_type registry for the AX60R5080WD/SE air purifier family, verified
against two independent diagnostics dumps (issue #56 and its comment). Binds
power, alarms, energy, diagnosis (reusing dishwasher.DIAGNOSIS), the dust/
fine-dust/super-fine-dust/odor/clean-level sensors off /sensors/vs/0, filter
progress, a device-active diagnostic, and a display-light switch parsed out
of /mode/vs/0's packed options list.

Fan speed/direction (/airflow/0, /airflow/vs/0) and two other /mode/vs/0
tokens (Comode_*, Blooming_*) are exposed as read-only diagnostics rather
than full controls -- neither dump has a supported-values list to confirm
their write contracts, so they're left for a follow-up once that's
clarified in the issue thread.

Hoists range_hood's items[]-sensor-value helper into common.py
(sensor_item_value) since air_purifier now reads the same /sensors/vs/0
shape.
2026-07-23 22:12:15 +00:00