common:
- Make KIDS_LOCK_GENERIC also a read-only BinarySensorDesc (device_class='lock'),
flipping value_fn to not bool(v) so /kidslock/0 value=False and
/kidslock/vs/0 kidsLock='Ready' render with the same polarity ('On'
means open/unlocked per HA's lock device class). The old SwitchDesc
form never honored device_class='lock' -- HA's switch platform only
accepts 'outlet'/'switch' -- so the surface was a plain switch whose
'On' meaning drifted across boards. Tests updated.
air_monitor:
- Add state_class='measurement' to dust/fine_dust/super_fine_dust so
the readings feed HA long-term statistics (co2 already had it).
- Import _AIR_QUALITY_SENSORS from air_purifier instead of duplicating
it byte-for-byte; update common.sensor_item_value's docstring to
mention the third caller.
by_type/__init__: drop trailing whitespace on the new 'ASM' line.
translations/en.json + nl.json: move the new 'dnd' switch entry to its
correct alphabetical position (after display_light, before fast_preheat).
SKILL.md: add an explicit read-side rule to §5's educated-guesses
section -- guessed unit/device_class/state_class on a SensorDesc
silently mislabels readings forever with no 4.xx to catch it (unlike
guessed writes, which the device rejects). The prior air_monitor
docstring cited this carve-out as if it existed; now it does.
tests/water_purifier (issue #196): change the ailite fixture's
favorite.defaultTemperature from '85' to '50' so the test actually
reproduces the reported bug -- '50' is in showList only, so a
descriptor reading from supportedList would fail the assertion that
the current default is in its options list.
The AILITE water-purifier board (RWP70F15ANW) spells its modelNum
'...-REF-WATERPURIFIER-...', so the board-token scan hit the bare 'REF'
token before ever reaching 'WATERPURIFIER' and misrouted the device to
the refrigerator registry, whose resource surface shares almost nothing
with a water purifier -- hence the incomplete-coverage warning. Add a
documented carve-out for this one token co-occurrence and a matching
TestBoardTokenAmbiguity exception.
Also bind the water-purifier hrefs this board additionally exposes:
cup-detection status, the settings/sound/{mode,output,volume} trio (read
live, since this board's own supportedModes vocabulary differs from both
laundry's and air_purifier's hardcoded/live sets), and last-pour
statistics.
Separately, gate hot_water_temperature off when the device doesn't report
a supportedHotTemperatures list (only a hotwaterRange/hotwaterLevel pair
with no confirmed write contract) -- previously an empty options list
plus a live current value rendered as 'unknown' in HA, the second bug
reported in #196. The existing water_purifier_coffee fixture (#107) turns
out to hit the same shape, so its golden drops the entity too.
Issue #195 (TP1X_REF_21K) needed no change: its diagnostics show zero
unbound hrefs and the model already routes to the refrigerator registry,
matching the maintainer's own comment on the issue.