Commit Graph
20 Commits
Author SHA1 Message Date
Marc Billow 3675d8087b Scope learning to the device, and simplify the store
The href alone was not a sufficient key. /mode/convenient/vs/0 is
declared by three family registries with three meanings: a real preset
resource on the AC, explicitly unmodeled on the dehumidifier (no live
current-value field), empty on the air purifier. Matching on the href
globally meant a dehumidifier reporting a mode there would learn it,
persist it, and show it in diagnostics for a resource nothing offers.
The coordinator now narrows LEARNABLE to the hrefs a climate entity is
actually bound to, at discovery -- which also retires the per-rep
subdevice walk, since those hrefs are already actual.

With that, LEARNABLE is a plain frozenset of hrefs and the per-href
LearnRule goes away: its two fields were the same module constants for
its only entry. observe() now returns the codes it learned rather than a
bool the caller re-reads the store to interpret, so the log names what
was new instead of everything ever learned.

learned.py also takes ownership of the entry key and persisted shape --
the options flow was the second module that knew both, and the shape has
already changed once.

Comment trims throughout, per CONTRIBUTING: the LEARNABLE entry no
longer recounts how many reporters there were, and three copies of the
same test-stub comment are gone.
2026-08-08 19:49:25 +00:00
Marc Billow 4f3bdde6e5 Address review findings on the learned-modes store
Flatten the store to {href: [codes]}. One href carries one LEARNABLE
rule, so keying the codes by the rule's supported field too let the
write side (rule.supported_field) and both read sides (the module-level
SUPPORTED_FIELD) disagree the moment a rule used a different field --
codes learned and persisted, then never offered.

The options flow's reset step read the persisted value raw in the
entry-not-loaded branch, so malformed data aborted the one screen that
can clear it; route it through LearnedModes like every other reader.
For the same reason forget_learned_modes() now persists whenever the
entry carries a record, not only when the in-memory store had one: a
record _coerce rejected at startup exists only on the entry.
2026-08-08 19:42:20 +00:00
Marc Billow d65735ac47 Remember modes a device reports but never advertises (issue #327)
Some firmware reports a current mode that is missing from the same
resource's supportedModes. An ARTIK051 air conditioner sits in Quiet
while advertising only [Off, Sleep, Speed, Nano, NanoSleep], so HA
showed preset_mode: quiet and then refused to select it. A second
reporter has three identical units where only the two sharing an
outdoor unit hide it, which rules out a real capability difference.

learned.py remembers any such code and the coordinator persists it on
the config entry, so a mode the device only names while it is active
survives a restart. climate._supported unions it into the resource's
own list, which fixes the read and the write together --
async_set_preset_mode reverse-resolves the device code from that same
list.

Learning is allowlisted per canonical href rather than global. Across
the fixture corpus 17 dumps already report a current mode that is not
in supportedModes: an oven idling in NoOperation, a fridge's
/mode/vs/0 carrying capability tokens like WATERFILTER_DISABLE. Those
are not selectable options, and remembering one permanently would put
an option in the UI that the device can only reject. Only
/mode/convenient/vs/0 is learnable today.

On by default, with a per-device option that stops offering and
learning at once, and a reset step in the options flow for a code that
turns out to be bogus. Diagnostics report what was learned separately
from `resources`, which stays exactly what the device said.
2026-08-08 19:10:53 +00:00
perseus177 eed04faaed fix(climate): derive presets only when the board publishes both capability maps
One map is not enough to judge by: with only OptionCode present, every
eoc-gated rule reads None, and None means the board does not publish the map
rather than that the feature is absent. artik051_dongle_fac_18k is exactly that
board and lost WindFree in every mode. Requiring both also keeps these bit
positions inside the family they were documented for -- the FAC and CAC dumps
carry only the older map, with values small enough that RAC positions read as
zeros.

Also from review: an unknown HVAC mode falls back the same way, Comfort is
spelled like the identical Speed rule, the unreachable AIComfort branch is
gone, the Cool code comes from the unit's own supportedModes, DlightCool gains
its catalog entry, and the Single User claim is dropped -- the app's own Single
User command sends Comode_Smart, so there is no distinct token to write.
2026-08-06 12:04:46 +02:00
perseus177 2d772f16a7 feat(climate): offer legacy presets per HVAC mode, from the unit's own capability bits
The fixed list of six was offered in every mode on every legacy board. The
appliance publishes what it has as two bit maps in /mode/vs/0's options, and its
own app gates each comfort mode on a bit plus the current mode; this transcribes
that logic. WindFree also needs the mode written before it in Auto, which is
measured rather than assumed.
2026-08-05 17:24:40 +02:00
perseus177 30bd0fd2af fix(airconditioner): Good Sleep needs the mode token its duration belongs to
Sleep_<n> written on its own is answered 2.04 Changed and then discarded, so
the Number wrote nothing at all. Nano wind shares the same Comode_ slot, which
is why writing the nano preset over a running timer silently changed its
duration, and why the two sleep codes the board reports had to become presets:
a preset_mode outside preset_modes is not a state HA allows.
2026-08-05 15:46:53 +02:00
Marc Billow 4e47a1c3d9 Merge pull request #296 from perseus177/ac-good-sleep-halfhours
fix(airconditioner): good_sleep is hours, but the token counts half hours
2026-08-05 08:18:03 -04:00
perseus177 93f45cb356 fix(airconditioner): good_sleep is hours, but the token counts half hours
The Sleep_ token was published as if its value were hours. It is not: the
appliance's own app pairs a duration picker with the values it puts on the wire,
one to one, and the pairing is half hours.

  0:00 0:30 1:00 1:30 2:00 2:30 3:00 4:00 5:00 ... 12:00
     0    1    2    3    4    5    6    8   10  ...    24

So the entity capped at 12 hours actually set six, every value asked for was
halved on the appliance, and twelve hours -- the app's own maximum, stated in its
help text -- could not be reached at all. The reading is halved and the write
doubled, and the step drops to 0.5 because that is the resolution the picker
offers.

Half-hour steps are what the app offers below three hours; above that it offers
whole hours only, so a half hour up there is untested rather than known-bad. A
Number cannot change step part-way, and turning this into a Select of the app's
sixteen values would change the entity's domain on every unit that already has
one, so the step stays 0.5 throughout and the comment says why.

The descriptor's own comment used to admit the upper bound was a guess ("only 0
has been observed on hardware"). The guess of 12 was right; the unit it was
expressed in was not.
2026-08-05 12:21:10 +02:00
perseus177 9ee0329467 feat(airconditioner): reset the legacy filter counter locally
FilterCleanAlarm_Clear, through the same single-token options merge as every
other setting on /mode/vs/0. Measured on an ARTIK051_KRAC_18K: 2.04 Changed and
FilterTime_95 (9 h 30 min) -> FilterTime_0, still zero on a fresh DTLS session
and on every poll after; none of the other 17 tokens moved and the alarm
entries stayed Deleted.

The counter has had no reset until now, and the descriptor said so: two earlier
rounds against live hardware failed, and the conclusion drawn from them was
that the reset had to be cloud-only. That conclusion was wrong, and the way it
was reached is the interesting part -- it came from diffing every resource the
appliance reports before and after pressing reset in Samsung's app, which
showed only the counter zeroing and the alarm clearing. A trigger token cannot
show up in such a diff, because a trigger is never stored. The appliance's own
app sends this token and skips the write when the counter is already zero.

Both failures stay in the comment, because they say what this is not: writing
FilterTime_0 (the value is not writable -- 5595 -> 5595 after 69 s, 1925 ->
1925 after 65 s, two units, opposite power states), and POSTing the cloud
capability's command name to /actions/vs/0 (real name, wrong transport).

Gated on the FilterTime_ token, so it appears only where there is a counter to
reset; newer boards report filter usage through their own resource and would
need a different mechanism.
2026-08-05 01:46:29 +00:00
perseus177 290a348017 feat(airconditioner): stop a running auto clean, and read its progress
Three tokens describe the drying cycle these boards run after cooling, and the
switch only covered the first. AutocleanProgress_ is how far a running cycle
has got, and StopAutoClean_ is a channel for ending one early -- its presence
is what says the appliance accepts that at all, which is how the appliance's
own app gates its stop button. Both tokens are reported by the ARTIK051_KRAC_18K
that issue #136 was about, and by every KRAC fixture here.

The percentage scale is the app's own: it renders the token into a
`<progress max="100">` with a "{{value}}%" label beside it. An idle unit reports
1 rather than 0 -- the same floor the laundry firmware's progressPercentage sits
at when Ready -- so 0-vs-1 is not a reliable "is it running" test, and the
button is deliberately not gated on it.

The sensor shares AUTO_CLEAN's catalog entry the way auto_clean_legacy already
shares the switch's: same figure, different board generation, distinct key so
nothing collides if a board ever reported both.

Stacked on #289 (this branch is cut from it) -- rebase or merge that first.
2026-08-05 00:45:20 +02:00
Marc Billow 07061c734d Fix more pre-existing ty diagnostics in test files
Continues narrowing SamsungEntityDescription accesses to the correct
subclass and asserting Optional write_fn/match_fn/exists_fn fields are
set before calling them, per the pattern established in the previous
commit.
2026-08-03 00:03:08 +00:00
Marc Billow daf7e3787f Add ruff (lint + format) and ty (type checking) to the project
Adds [tool.ruff] and [tool.ty] config to pyproject.toml with a curated
ruff rule set (E, F, W, I, UP, B, C4, SIM, RUF, ASYNC, LOG, G, PIE, RET,
PERF, N), pins ruff/ty in requirements-dev.txt, reformats the whole tree
with `ruff format`, and fixes the pre-existing lint and type-check debt
those tools surfaced so both run clean.

Production-code type fixes include: HA's ConfigFlowResult vs. the
generic FlowResult in config_flow.py, narrowing BoundEntity.desc to its
platform-specific subclass (SelectDesc/NumberDesc/SensorDesc/etc.) via
cast() instead of an unchecked annotation, converting HA device_class
strings to their proper enum types, a resolve_registry callback typed
as `object` instead of `DeviceRegistry | None`, and a couple of other
narrow correctness fixes (CA key type validation, an index-out-of-bounds
false positive from an empty-tuple fallback, a bool/dict argument swap).

Test-file fixes are mechanical: narrowing SamsungEntityDescription to
the correct subclass via isinstance()/cast() before accessing
subclass-only fields, and asserting Optional write_fn/unit_fn fields
are set before calling them.
2026-08-02 23:56:38 +00:00
perseus177 9ee0dbb8f9 feat(airconditioner): filter alarm interval on legacy ARTIK051 boards
Adds the Select the official app offers next to the filter reminder --
180/300/500/700 hours -- which this board generation keeps as a FilterAlarmTime_
token in /mode/vs/0's options[] rather than on a /filter/* resource.

Confirmed on hardware: stepping through all four radio positions in the app
moved that one token and nothing else across all 19 resources, so the token
carries the hour count verbatim; and a local write of 500 to a unit sitting on
700 was accepted and kept, surviving a restart. The cloud exposes none of this,
so it is only available locally. Gated with the counter it belongs to, so
boards carrying a real /filter/airdustfilter/vs/0 threshold keep using that one
-- the gate is covered by a test that injects the token into a newer board's
dump, since no non-legacy fixture carries it and the assertion would otherwise
pass for the wrong reason.

Also settles what filter_time measures: it counts UP -- running time
accumulated since the last filter reset, not time remaining -- which an earlier
revision of that comment explicitly left open. Three independent things agree:
the token rising while the unit runs, FilterAlarmTime_ being the threshold it
is measured against, and /alarms/vs/0's filter entry tracking the counter
across two units on one site (a live unsuffixed 'FilterAlarm'/'Created' at
FilterTime_5595 against the 'FilterAlarm_OFF'/'Deleted' placeholder at 1915).
The alarm clearing by itself the moment the counter dropped under the threshold
is the causal half of that, not just correlation.

Resetting the counter is NOT solved and no reset entity is added. The
descriptor records what was tried, and what the failures do and do not prove,
so the next attempt starts from evidence instead of from scratch. Short
version: the reset is a *command* (custom.dustFilter/resetDustFilter), not a
value write, which is why nothing that writes the counter works; I could not
work out how to drive that command locally. /actions/vs/0 is the obvious local
command channel but publishes no schema, and I did not enumerate guessed action
names against a live appliance.

Written with Claude (AI), on the author's own hardware; every result quoted
above is measured on the device rather than inferred.
2026-07-31 12:41:40 +02:00
Marc Billow 9e85395b44 rename: unit/sub-unit -> subdevice, matching OCF terminology
"Unit"/"sub-unit" from #199's multi-indoor-device support wasn't OCF
idiomatic -- OCF calls each component of a composite device a
"subdevice" (see subdeviceIdList), so rename SubUnit -> Subdevice
throughout: the registry module, coordinator state, BoundEntity's
subdevice field, diagnostics keys (subdevices/subdevices_skipped/
subdevice_probes), entity unique_id prefixes (unit1_/sub_<uuid>_ ->
subdevice1_/subdevice_<uuid>_), device-name fallback labels, golden
fixtures, tests, README, and the adding-device-support skill.

Breaking change to entity unique_ids and diagnostics keys, acceptable
since this hasn't been released yet.
2026-07-29 22:57:11 +00:00
Marc Billow 9442248c20 Merge origin/main into multi-device sub-unit support
Conflict was purely additive: both sides appended golden-regression
tests at the same point in the file, and each side's last test shared
the single trailing assert block. Kept every test from both sides, each
with its own copy of that assert.

One real semantic merge on top of that. #136 (on main) remodelled the
legacy ARTIK051 board's beep from a buzzer_volume Number to a beep
Switch, and HJcom's ARTIK051_DONGLE_FAC_18K is exactly that board
generation (is_legacy_board -> True), so its golden -- written before
that change existed -- still expected buzzer_volume. Regenerated it:
buzzer_volume/unit1_buzzer_volume -> beep/unit1_beep on the master and
the second indoor unit alike, with nothing else moving and still no
unit2_ keys. That is main's intended behavior reaching the sub-unit for
free, which is the point of binding siblings through the same registry.

967 passing. Re-ran the corpus-wide unique_id audit over all 57
fixtures (main added five this branch had never seen): no collisions
within a platform.
2026-07-29 19:40:32 +00:00
Marc Billow c181a8b447 feat(subdevices): support multi-indoor-unit systems (#177)
Samsung 2-in-1 air conditioners put more than one logical indoor unit
behind a single IP and a single DTLS session. Only the unit the config
entry was set up against was ever discovered; the second one -- a whole
physical appliance the user can see in SmartThings -- had no entities at
all. Two reporters turned out to have two different mechanisms:

  ARTIK051_DONGLE_FAC_18K -- indexed siblings. /oic/res registers the
  whole tree discoverable and lists three complete parallel resource
  sets whose trailing path segment is the index (/mode/vs/0, /mode/vs/1,
  ...), on OCF-standard and vendor hrefs alike. /device/0's batch
  carries only the index-0 hrefs, so a sibling is reachable only through
  its own /device/<n> collection.

  TP2X_FAC_BORA_21K -- UUID-prefixed tree. /oic/res hides the appliance
  tree entirely (which is why a direct /device/1 probe returns nothing
  on this board). /subdevices/vs/0 carries subdeviceIdList instead, and
  that UUID appears as a literal href prefix; /<uuid>/information/vs/0
  was confirmed live to return the wall unit's own model and serial
  (TP2X_FAC_BORA_RAC_21K) against the master's TP2X_FAC_BORA_21K.

The detection signals don't overlap on either board, so no
disambiguation is needed -- enumeration checks both and takes what
answers.

Both patterns are the same thing underneath: a logical unit is a seed
collection path to poll plus an href transform between the canonical
href the registry knows and the actual on-the-wire href. That is the
whole abstraction (SubUnit), applied at four boundaries -- discovery,
the coordinator, the adapter, and the platforms. Capabilities, the
registry and the climate composite stay written against canonical hrefs
and are untouched.

Uniqueness comes from a key_prefix inside the flattened state key, so
the master unit's keys are byte-identical to every release before this
and every existing golden file is an unchanged regression guard. Each
sub-unit gets its own device-registry entry linked by via_device and
named from its own /information/vs/<n>, so it lands in its own room
rather than crowding the master's device page.

A sub-unit materializes only when it yields at least one primary
(non-diagnostic) entity with a populated value. That gate is not
decoration: the reporter's /device/2 is an unused slot that SmartThings
shows disabled, yet it answers with a full 14-href batch, and it
flattens to exactly one non-None value -- a diagnostic alarm_code
derived from an empty /alarms/vs/2. Without the entity-category filter
it becomes a phantom third climate card. The rule is deliberately
domain-agnostic rather than a list of HVAC hrefs, so a multi-drum
washer (#19) gets the same treatment with no new curation. Units that
answer but fail the gate are logged and reported in diagnostics, so a
genuinely missing unit stays diagnosable from a dump.

Enumeration fetches things that must not then be treated as appliance
state. A rejected candidate's seed has to be read to evaluate the gate,
but only units that pass are polled again, and StateCache has no
eviction -- so discovery runs before the first cache apply and those
reps are held aside for diagnostics rather than frozen into the cache
forever. /multidevice/vs/0 is probed on every device regardless of
family, so merging it into the resources dict would have reached
discovery on any board whose registry doesn't ignore that href -- only
the air conditioner one does -- raising a spurious coverage-gap repair
for a washer or fridge whose firmware answers it. It is corroborating
metadata (numofsubdevice, confirmed read-only) and now lives beside the
resources rather than in them.

Diagnostics reports each unit separately: top-level `resources` is this
unit's own and only its own, which is what the module docstring and the
adding-device-support skill have always claimed it was, and each
sibling or rejected candidate carries its own reps canonicalized so a
block reads exactly like the master's instead of needing to be
de-indexed by hand.

Fixtures are real captures. The ARTIK051_DONGLE_FAC_18K one is entirely
verbatim, both sibling seeds and the hand-read /multidevice/vs/0
included. The TP2X_FAC_BORA one has a real device0, oic_res and
sub-unit /information/vs/0, with the remainder of that unit's tree
constructed and documented as such in seeds_note; /<uuid>/device/0 is
the one part of that pattern still inferred rather than observed, and
can't be tested through the debug panel because a Collection returns a
list.
2026-07-29 19:14:51 +00:00
Marc Billow 487ac748bd fix(airconditioner): model legacy-board beep as a switch, not a volume (#136)
Every ARTIK051_KRAC_18K-generation unit confirmed on hardware (three units
across two reporters) only ever carries Volume_100 or Volume_Mute in
/mode/vs/0's options -- never an intermediate value -- so the existing
buzzer_volume Number (0-100, step 10) modeled a control this firmware
doesn't have. Worse, its write path could never produce the literal
'Mute' token needed to actually turn the beep off, since it only ever
wrote a plain integer string. The 'beep' switch already used on newer
boards is the correct model here too; it's no longer gated off the legacy
board generation, and the Number entity is removed.

The WindFree-preset-not-applying report earlier in this issue self-resolved
per the reporter's own follow-up testing, so no code change was needed for
that part.
2026-07-29 13:16:09 +00:00
Marc Billow 57e06c5ccb De-duplicate the legacy ARTIK051 AC board-generation test (#161)
capabilities/airconditioner.py's is_legacy_board() (renamed from the
private _is_legacy_board -- it's now a cross-module helper) and
climate.py's _legacy_airflow() implemented the same "does this board have
/airflow/vs/0 but no /wind/strength/vs/0" test independently, one via
literal href strings and the other via coordinator.resource() truthiness.
is_legacy_board() now uses the module's own HREF_AIRFLOW/HREF_WIND_STRENGTH
constants, and _legacy_airflow() delegates to it via a minimal two-key
presence dict (cheaper than a full last_resources snapshot copy) instead of
re-implementing the check, so the token entities and the climate card's
legacy read/write paths can't drift apart on which board generation is in
play.
2026-07-28 13:31:37 +00:00
perseus177 55c7b88a8f fix(airconditioner): label the 2Step preset and test presets by their HA value
The legacy Comode codes resolve through the same dynamic resolver as a real
convenient resource, so Nano lands on the existing 'nano' preset (already
labelled WindFree) rather than on a 'windfree' value of its own -- the new
tests asserted the label instead of the value. 2Step had no catalog entry in
either language and would have surfaced as the raw code.

Also updates the existing five-percent-humidity test, which reached into the
descriptor's field/value_fn directly, to the rep_fn the fallback needs, and
covers the fallback itself.
2026-07-28 02:38:28 +02:00
perseus177 3032b0c032 test(airconditioner): lock in the ARTIK051_KRAC_18K surface
Fixture is a scrubbed diagnostics dump from the unit the writes and
calibrations were verified on; the issue #136 unit is the same model with a
slightly different token set (no Spi, FilterTime_5460, OutdoorTemp_81), which
the presence gating handles the same way.

Covers the pieces the golden's state_keys can't: that the token entities stay
off newer boards, that an absent token yields no entity, that humidity's zero
reads as unknown, that fan/swing/preset read and write through /airflow/vs/0
and the Comode token, and that a board with /wind/* and /mode/convenient/vs/0
still takes the resource paths.

Refs #136
2026-07-28 02:28:59 +02:00