Commit Graph
10 Commits
Author SHA1 Message Date
Marc Billow daf7e3787f Add ruff (lint + format) and ty (type checking) to the project
Adds [tool.ruff] and [tool.ty] config to pyproject.toml with a curated
ruff rule set (E, F, W, I, UP, B, C4, SIM, RUF, ASYNC, LOG, G, PIE, RET,
PERF, N), pins ruff/ty in requirements-dev.txt, reformats the whole tree
with `ruff format`, and fixes the pre-existing lint and type-check debt
those tools surfaced so both run clean.

Production-code type fixes include: HA's ConfigFlowResult vs. the
generic FlowResult in config_flow.py, narrowing BoundEntity.desc to its
platform-specific subclass (SelectDesc/NumberDesc/SensorDesc/etc.) via
cast() instead of an unchecked annotation, converting HA device_class
strings to their proper enum types, a resolve_registry callback typed
as `object` instead of `DeviceRegistry | None`, and a couple of other
narrow correctness fixes (CA key type validation, an index-out-of-bounds
false positive from an empty-tuple fallback, a bool/dict argument swap).

Test-file fixes are mechanical: narrowing SamsungEntityDescription to
the correct subclass via isinstance()/cast() before accessing
subclass-only fields, and asserting Optional write_fn/unit_fn fields
are set before calling them.
2026-08-02 23:56:38 +00:00
Marc Billow cafd7d5afa refactor(registry): drop oneUiVersion from device-type detection
oneUiVersion looks like the signal you'd want -- the device naming its own
type, '7.0 Dishwasher' -- and it was the first thing detection consulted. It
never earned the position:

- Only 7 of 49 fixtures report it at all.
- All 7 resolve to the same registry from their modelNum board token alone.
- No device-support issue has ever been fixed by adding a mapping for it.
  Every one went through modelNum. The alias keys it needed in
  _REGISTRY_BY_KEY ('airpurifier', 'air_conditioner', 'hood') were
  speculative when the registries were first written and never used since.

So it bought a key-normalizing helper (_type_key), a lookup with a suffix
fallback (for_device), three alias keys, and a second config-flow step whose
only reason to exist was phrasing a sentence about oneUiVersion -- for a
signal that has never once been decisive.

Remove it from detection. It stays in diagnostics, where it's genuinely
useful: it names the firmware generation ('7.0 Air conditioner' is Tizen
Lite), which matters when triaging an issue.

Detection order was also duplicated in four places -- the coordinator, the
config flow's probe, the golden-regression harness, and the skill -- which
is how the harness and the shipped order drift apart. Collapse it into
by_type.resolve(resources), and call that everywhere.

The two "appliance type not recognized" config steps become one. They
differed only in whether they blamed a missing oneUiVersion, which is not a
distinction a user can act on, and never was.

Verified by the full suite (795 passing), including every golden regression
-- so entity output is byte-identical for all 49 device fixtures.

TestOneUiVersionIsNotConsulted locks in the premise rather than just the
outcome: for every dump that reports a oneUiVersion, the model strings alone
must still reach a registry. If a future device breaks that, the test says
so instead of the device silently losing half its entities.

Also note in requirements-dev.txt that Python 3.13 resolves the pinned
harness floor -- 3.12 and older resolve nothing and fail the whole install.
2026-07-29 02:14:13 +00:00
Marc Billow 569029c116 refactor(observe): stop tearing down live sessions on data-drift or poll hiccups
Replace the breadth/silence downgrade heuristic with a simpler rule: a
still-live OBSERVE session is never torn down on a sweep/cache mismatch
(the 30s sweep already corrects the cache regardless of mode) -- only a
proven reconnect invalidates subscriptions. A mismatch instead triggers
extra hot/warm subpolls this cycle as a bounded fallback.

Also stop treating a summary-poll block-level ACK timeout as session
death: distinguish TimeoutError (transfer was progressing, session
likely alive) from ConnectionError (session actually closed), backed by
a consecutive-timeout counter so a genuinely dead channel still
recovers. This was causing a flaky/slow device (e.g. a dishwasher) to
flap observe<->poll every ~45s on nothing but a slow blockwise GET.

Also remove the dead is_active/active_when scaffolding (never wired
into the coordinator) and add DEBUG logging for each OBSERVE notify
received, including its href.
2026-07-10 19:50:40 -05:00
Marc Billow b67e0e5cf5 Rename ocf/ to registry/, it's a capability registry now
The DTLS/CoAP transport code that made "ocf" an accurate name moved out to
the smartthings-local package. What's left here (capability.py, entities.py,
discovery.py, adapter.py, identity.py, capabilities/, by_type/, plus the
/device/0 batch parser) is entirely the device capability registry, so name
the package for what it does.

Flattened the redundant ocf/registry/ nesting into a single top-level
registry/ package and updated every import across the platform modules and
test suite accordingly. Verified: full test suite (80/80) passes, and the
Docker dev container reconnects to both live appliances and rediscovers
their entities cleanly after the rename.
2026-07-07 22:54:57 -05:00
Marc Billow cc2c1e5a1f refactor: move samsung_appliance/ into custom_components/localthings/ocf/
Makes the integration fully self-contained for HACS distribution.
Users installing via HACS get everything in one directory; no external
samsung_appliance package needed.

All component imports updated to relative (.ocf.*); all test imports
updated to custom_components.localthings.ocf.*. ocf_root_ca.pem moves
with the package and resolves correctly via Path(__file__).parent.
2026-06-30 16:34:20 -05:00
Marc Billow f7b58f00ee feat: replace MQTT bridge with localthings HA custom component
Convert from MQTT bridge architecture to a proper Home Assistant
integration (custom_components/localthings/):

- Config flow: IP-only entry, probes ports [49154,49155], cert/key
  reused from first device on subsequent adds
- Coordinator: DataUpdateCoordinator wrapping blocking DTLS session
  via async_add_executor_job; discovery on first poll; dynamic 5s/30s
  interval based on active_when
- Entity platforms: sensor, binary_sensor, switch, number, select
- Library cleanup: delete bridge.py, main.py, config.py, logger.py,
  keepalive.py, poll_scheduler.py, sensors.py, state_cache.py
- adapter.py stripped to flatten(), is_active(), _key()
- _parse_device0_batch moved to samsung_appliance/batch.py
2026-06-30 16:34:06 -05:00
Marc Billow fd2aa9e64d fix: replace IP-named dumps with scrubbed named fixtures
Rename tests/fixtures/dumps/{IP}.json to tests/fixtures/{name}_device.json.
Scrub PII: serialNum, otnDUID, modelNum, diagEndPoint replaced with
TEST-* placeholders. conftest: _load_device(name) as primary API;
_load_resources(ip) kept as legacy shim for existing test call sites.
2026-06-30 16:33:36 -05:00
Marc Billow 27d6d09fd9 refactor: auto-derive pattern cap keys from href; move dumps to tests/fixtures
Remove key_fn from Capability — pattern cap keys are now always derived
automatically: strip digits from href segments, join with '_', append
'_' + desc.key. /door/cooler/0 + 'open' -> door_cooler_open.

DOOR_GENERIC entity key: 'open' (not 'door_open'). Remove _door_key helper.
Fridge registry: DOOR_FRIDGE/DOOR_FREEZER replaced by DOOR_GENERIC pattern cap.
Golden baseline: door_fridge_open -> door_cooler_open.

Move device dumps to tests/fixtures/dumps/ (tracked) so tests run in CI
without local-tools/ dependencies.
2026-06-30 16:33:36 -05:00
Marc Billow 6f681622c2 fix: remove unused request param, use context manager in e2e v2 test 2026-06-30 16:33:36 -05:00
Marc Billow ee7ae10481 test: add v2 e2e smoke test (batch + per-type registry full pipeline) 2026-06-30 16:33:36 -05:00