progress_percentage lacked the active-state gate already applied to
progress/cycle_active/finish_time, so it kept showing a stale device value
(e.g. 1%) while idle -- now zeroed the same way. Shared by dryer/dishwasher/
oven via operational.py's OPERATIONAL_STATE.
Also exposes detergent/softener auto-dispense quantity, water hardness/
concentration, and low-reservoir alarms from /course/vs/0's options array,
using the same decode/RMW helpers already used for course selection and
drum-clean tracking. Gated by exists_fn so washer models without these
fields (e.g. the existing test fixture) are unaffected.
Water consumption is unaffected -- common.WATER_METER is already wired
into the washer registry; this reporter's device just doesn't expose
/water/consumption/vs/0.
Washer (#6): instantaneousPower is a dead sentinel ('-500') on every
TP1-class washer dump collected so far, and cumulativePower is absent
outright on at least one model. WASHER_ENERGY_METER now hides both
sensors instead of showing a misleading "0 W"/perpetual "unavailable".
Fridge (#7): temperature sensors/setpoints hardcoded '°F', ignoring the
unit each device actually reports per-reading -- fixed via a new
unit_fn hook read live from the resource. Also corrects
DEFROST_BLOCK_STATUS's polarity (DEFROST_BLOCK_ON means actively
defrosting, not "blocked", confirmed against live dumps) and adds
REFRIGERATION_FALLBACK for /refrigeration/0, closing the last unbound
href surfaced by issue #7's diagnostic dump.
Oven: applies the same live-unit-reading fix defensively to
OVEN_SETPOINT, which shares the same aggregate resource shape.
Adds cycles-until-due and last-cleaned sensors decoded from the same
options[] array the course selector already reads (DrumCleanProposal_N -
WashingTimes_N for cycles remaining, DrumCleanLog_<iso> for last-cleaned),
verified byte-for-byte against a live app screenshot ("Potreba cistenia po
37 cykloch" / "Naposledy cistene pred 10 dnami").