Commit Graph
9 Commits
Author SHA1 Message Date
Marc Billow 8814fffa4f airconditioner: ungate outdoor_temperature from is_legacy_board
The OutdoorTemp_ options token was only surfaced on legacy boards
(is_legacy_board), even though 14 of 17 fixtures carrying the token are
non-legacy. issue #367 confirmed with a 48h field capture (r=0.92
against weather.forecast_home) that the token tracks real outdoor
temperature independent of board generation, and that no non-legacy
board exposes an alternative outdoor-temperature resource.

Split a token-presence-only exists_fn (_has_option_token_any_board) for
this token, leaving _has_option_token's legacy gate untouched for the
other options[] settings that still need it. Ships enabled_default=False
since multi-split installs report the same token on every indoor head,
which would otherwise create one duplicate active sensor per head.

Updates the golden fixtures for the 14 affected boards and the
artik051_krac test that had asserted outdoor_temperature stays off
newer boards.
2026-08-15 21:22:09 +00:00
Marc Billow a7dc1db8ff Extract usable parts of PR #316 (System Fresh Air Ventilator support)
PR #316 (fork stale by several months, most of its ~2200-line diff was drift
against main rather than real changes) proposed device support for the
Samsung System Fresh Air Ventilator (ACA-KR-TP2-21-AN9000). Extracted what
holds up, adapted to this project's conventions, and left out what doesn't:

Extracted:
- ventilation_mode select on CLIMATE's own href, gated via
  _is_ventilation_mode_device so it can only ever bind on a device whose
  entire supportedModes set is Purification/Ventilation/SmartVentilation --
  verified against every real AC fixture in the corpus to confirm it can't
  false-positive on an actual air conditioner's climate card.
- WINDFREE / WINDSLEEP switches on their own dedicated hrefs.
- A CO2 sensor on AIR_QUALITY, matching air_monitor.SENSORS' already-bound
  device_class='carbon_dioxide'/unit='ppm' descriptor for the same field
  shape rather than guessing fresh.
- HEPA_FILTER / DEVICE_ACTIVE reuse from air_purifier.py.
- Removing /airlevelcheck/vs/0 from _AC_IGNORED and binding
  air_purifier.AIR_LEVEL_CHECK in its place: the PR's claim that this
  project's old "scheduler plumbing" description was wrong turned out to
  be independently verifiable against two of our own existing fixtures
  (airconditioner_cac and airconditioner_tp1x_da_ac_rac_01011 both already
  carry real, populated periodicSensingActivationState/autoExeState
  values), so this benefits existing users, not just the one new device.

Left out:
- Unit/device_class ('ug/m3', pm10/pm25/pm1) on the existing dust/
  fine_dust/super_fine_dust sensors, sourced from an unverified third-party
  screenshot description. air_monitor.py already has an explicit, reasoned
  rejection of this exact mapping for the exact same three fields:
  Samsung's PM10/PM2.5 convention doesn't confirm where a third tier or a
  PM1 reading fits, and a wrong guess mislabels the reading forever.
- A standalone common.POWER switch -- contradicts this registry's own
  documented design (power is deliberately the climate entity's job) and
  would affect every AC user, not just this device.
- Promoting wind/swing to independent selects for every AC user -- a UX
  opinion, not a coverage necessity, and out of scope for this device's
  own support.
- A model-name diagnostic sensor -- /information/vs/0 is already covered
  via the global ignore list, so this wasn't closing an actual gap.

No raw diagnostics dump for this model was ever attached to PR #316, so
there's no fixture for it here (fabricating one would violate this
project's fixture-integrity rule) -- see
tests/test_airconditioner_ventilation_windfree.py's module docstring.
2026-08-07 16:38:09 +00:00
Marc Billow e2dcc75ed5 Address Opus review findings on the device-support commits above
- Fix a real bug: airconditioner.SOUND_MODE had no exists_fn, so on
  boards (issue #319's FAC) that never report a live 'mode' value,
  entity.py's default field-presence gate silently kept the select from
  ever registering in HA -- while adapter.flatten() (what the golden/tests
  read) has no such gate, so the tests passed while documenting behavior
  the opposite of what shipped. Gate on supportedModes' presence instead.
- Add airconditioner.MDS_ABSENCE_CLEAN for the CAC-class board's
  /mds/absenceclean/vs/0 -- byte-identical shape to issue #319's
  /csi/absenceclean/vs/0, confirmed rather than guessed, closing one more
  of that board's documented coverage-gap hrefs.
- Add missing translation state labels (all 6 languages) for
  edge_lighting_mode/edge_lighting_color/indicator_light_mode's raw device
  codes, so they render as real words instead of a raw '3000K' -> '3000 K'
  fallback.
- Fix an orphaned comment above SOUND_MODE that actually described the
  unrelated DISPLAY reuse, and correct two inaccurate rationale comments:
  the sound/voice ignore reason claimed a distinction from SOUND_MODE that
  this same dump contradicts, and the /csi/* ignore block's 'same
  reasoning as air_purifier.COVERAGE' precedent only actually covers 1 of
  its 5 hrefs.
- Correct the false 'no board-token match' claim in the FAC test file and
  golden-regression docstring -- 'FAC' is a real _BOARD_TOKEN_TO_KEY entry
  (for_device_by_model alone already resolves this board); add a test
  that actually exercises that path, which nothing previously did despite
  the docstring's claim.
- Drop a tautological burner-slot test that only re-asserted what the
  golden regression test already covers via the same code path.
2026-08-07 14:50:24 +00:00
Marc Billow c203bd42c5 Add edge-lighting and indicator-light support for TP1X_DA-AC-CAC-01001 (issue #288)
Six System A/C cassette units on the same board test_airconditioner_cac.py
already documented as having an incomplete coverage gap gave real dump
evidence for two of its remaining unbound hrefs:

- /edgelighting/vs/0: an accent-light strip with on/off, a Smart/High/Low
  mode, and a Kelvin color-temperature select (3000K/4000K/6500K), all read
  from the device's own live supported-value lists.
- /light/stateful/vs/0: a second, distinct light resource with its own
  on/off and Smart/Low/High mode -- not to be confused with EDGE_LIGHTING
  or DISPLAY_LIGHT's ambient mood light.

convenientMode/operatingOption on /edgelighting/vs/0 stay unexposed: present
on every dump but no evidence of what either actually controls.

Only three hrefs remain in test_airconditioner_cac.py's documented gap now
(absence-clean, sound-optimization, smart-sensing-cooling).
2026-08-07 14:27:25 +00:00
Marc Billow edf77309ba Add device support for AILP_DA-AC-FAC-02011 air conditioner (issue #319)
This board routes purely via /oic/d's oic.d.airconditioner type (no
board-token match) and reports several resources the sibling
TP1X_DA-AC-CAC-01001 board (issue #191) left as a documented gap:

- /display/vs/0, /settings/sound/output/vs/0, /settings/sound/volume/vs/0
  now reuse air_purifier.py's identical-shape capabilities instead of
  duplicating them.
- /settings/sound/mode/vs/0 gets a new airconditioner.SOUND_MODE reading
  the live supportedModes field, sharing laundry.py's existing
  voice/tone/mute translation catalog since the value vocabulary matches.
- /csi/absenceclean/vs/0 and /csi/energysaving/vs/0 are new, genuinely
  useful controls (absence auto-clean toggle, energy-saving mode select
  plus its state/operatingStatus diagnostics).
- /dnd/autosleep/vs/0, /outdoorsharing/vs/0, /lifestyle/survey/vs/0,
  /settings/sound/voice/vs/0 and /csi/information/vs/0 are ignored as
  plumbing/unconfirmed data with no user-actionable state.

Also fixes a latent bug in air_purifier.SOUND_VOLUME: boards that report
minLevel/resolution but no maxLevel (this one) would have produced a
min=0/max=0 number entity instead of self-gating off.

Updates test_airconditioner_cac.py's documented coverage gap now that
sound_mode/sound_output/sound_volume are covered there too.
2026-08-07 14:10:13 +00:00
Marc Billow cf09247e39 Add AC UV LED, ventilation alarm, and PM1 filter support (issue #270)
TP1X_FAC_TIME_23K reports three previously unbound hrefs: a UV-C
sterilization LED and a ventilation-reminder alarm (both plain On/Off
toggles), and a second PM1-rated dust filter with no live usage/status
fields on this particular dump.

The PM1 filter capability gates each entity on its own field's presence
rather than a blanket ignore, since the TP1X_DA-AC-CAC-01001_0000 cassette
AC (issue #191) reports the same href with full live data -- this also
closes two of that device's ten documented coverage gaps (UV LED and the
PM1 filter) as a side effect.
2026-08-03 19:07:03 +00:00
Geunwon Mo 5c275753d4 Report whether the auto-clean cycle is running, and how far through
`/option/autoclean/vs/0` carries three fields and only `settingStatus` was read.
That one says the feature is enabled, which it is whether or not the unit is
drying right now, so nothing reported an actual cycle.

    settingStatus: On      <- the existing auto_clean switch
    status:        Stop    supportedStatus: [Start, Stop]
    progress:      0

Adds a binary sensor for `status` and a percentage sensor for `progress`.

Measured on a TP1X_DA-AC-CAC-01001, sampling the resource every eight seconds
across a cycle: `Start` with progress 98 while it ran, then `Stop` with progress 0
the moment it finished. The percentage matches the figure the appliance shows on
its own display, checked against 55% mid-run.

Golden state keys updated for the 18 fixtures that bind AUTO_CLEAN. The change is
additive — no key was removed from any of them.

Full suite passes (1070 tests, Python 3.13 via requirements-dev.txt).
2026-08-02 22:01:27 +09:00
Petr Divis f15ee7e563 Update golden fixtures for the new odor-controller entities
CI caught it: 8 pre-existing AC fixtures also carry genuine SmartCoolClean_/
ProgressSmartClean_ tokens in /mode/vs/0 (lnx_rac_heatpump, ara_ww_tp1_22,
windfree_oscillation, tp1x_rac_01001, fac_bora, fac_bora_2in1,
fac_bora_205_flat, cac), so odor_controller_active/odor_controller_progress
now correctly bind there too -- their golden state_keys lists just hadn't
been regenerated. Verified against the actual downloaded CI job log.
2026-07-31 16:39:08 +02:00
Marc Billow bd3ca80d3c review: address Opus code-review findings on this branch
- config_flow: the #192 port-rescue made the "every port refused" fast-fail
  permanently unreachable (PREFERRED_PROBE_PORTS is always non-empty and
  always rescued), so removed the dead branch instead of leaving it as
  misleading dead code. A dead host now fails via the handshake loop's own
  error, which carries the real per-port reason.
- oven._has_option: added the is_stub_rep carve-out cooktop.py's identical
  per-token exists_fn already has on the same kind of href, so a not-yet
  sub-polled /mode/vs/0 doesn't permanently exclude energy_saving/
  cooktop_on_alert before their first real fetch lands.
- airconditioner.ENERGY_METER_LEGACY: build via dataclasses.replace() like
  its ENERGY_METER_GENERIC sibling, instead of hand-copying href/poll_tier
  (which would silently drift if common.ENERGY_METER ever gains a field).
- Fixed two stale comments: is_legacy_board()'s docstring still listed
  Volume among tokens needing legacy-only gating, though 'beep' now applies
  unconditionally across board generations; and common.py's UNIVERSAL
  invariant comment didn't mention that airconditioner also now excludes
  ENERGY_METER from the wholesale bundle.
- #191 (CAC token): added the fixture/golden/capability-test coverage the
  AVT token in the same branch got, including an honestly-documented list
  of the ten hrefs this board generation doesn't cover yet.
- fridge.cooler_temperature_setpoint: dropped the hardcoded "N °C" state
  labels -- the resource's own unit field isn't necessarily Celsius on a
  different model reporting the same href, and the options themselves are
  already read live via options_field, so a static per-value label risked
  asserting the wrong unit for a future device sharing this capability.
- airconditioner._legacy_cumulative_power_kwh: parse with float (matching
  common.wh_to_kwh's own numeric parsing) instead of this module's
  integer-only _int, so a decimal-formatted reading doesn't raise.
- test_config_flow: the port-rescue test bound the real 49154 directly,
  which could collide with an actually-running service on some machine;
  now monkeypatches PREFERRED_PROBE_PORTS to an OS-assigned port instead.
- oven.py: consolidated six byte-for-byte-identical single-token options
  write_fns (lamp/sound/fast_preheat/natural_steam/energy_saving/
  cooktop_on_alert) into one _option_switch_write(prefix) factory.

845 tests passing (up from 841 -- 4 new CAC coverage tests).
2026-07-29 18:04:23 +00:00