Files
Marc Billow a7dc1db8ff Extract usable parts of PR #316 (System Fresh Air Ventilator support)
PR #316 (fork stale by several months, most of its ~2200-line diff was drift
against main rather than real changes) proposed device support for the
Samsung System Fresh Air Ventilator (ACA-KR-TP2-21-AN9000). Extracted what
holds up, adapted to this project's conventions, and left out what doesn't:

Extracted:
- ventilation_mode select on CLIMATE's own href, gated via
  _is_ventilation_mode_device so it can only ever bind on a device whose
  entire supportedModes set is Purification/Ventilation/SmartVentilation --
  verified against every real AC fixture in the corpus to confirm it can't
  false-positive on an actual air conditioner's climate card.
- WINDFREE / WINDSLEEP switches on their own dedicated hrefs.
- A CO2 sensor on AIR_QUALITY, matching air_monitor.SENSORS' already-bound
  device_class='carbon_dioxide'/unit='ppm' descriptor for the same field
  shape rather than guessing fresh.
- HEPA_FILTER / DEVICE_ACTIVE reuse from air_purifier.py.
- Removing /airlevelcheck/vs/0 from _AC_IGNORED and binding
  air_purifier.AIR_LEVEL_CHECK in its place: the PR's claim that this
  project's old "scheduler plumbing" description was wrong turned out to
  be independently verifiable against two of our own existing fixtures
  (airconditioner_cac and airconditioner_tp1x_da_ac_rac_01011 both already
  carry real, populated periodicSensingActivationState/autoExeState
  values), so this benefits existing users, not just the one new device.

Left out:
- Unit/device_class ('ug/m3', pm10/pm25/pm1) on the existing dust/
  fine_dust/super_fine_dust sensors, sourced from an unverified third-party
  screenshot description. air_monitor.py already has an explicit, reasoned
  rejection of this exact mapping for the exact same three fields:
  Samsung's PM10/PM2.5 convention doesn't confirm where a third tier or a
  PM1 reading fits, and a wrong guess mislabels the reading forever.
- A standalone common.POWER switch -- contradicts this registry's own
  documented design (power is deliberately the climate entity's job) and
  would affect every AC user, not just this device.
- Promoting wind/swing to independent selects for every AC user -- a UX
  opinion, not a coverage necessity, and out of scope for this device's
  own support.
- A model-name diagnostic sensor -- /information/vs/0 is already covered
  via the global ignore list, so this wasn't closing an actual gap.

No raw diagnostics dump for this model was ever attached to PR #316, so
there's no fixture for it here (fabricating one would violate this
project's fixture-integrity rule) -- see
tests/test_airconditioner_ventilation_windfree.py's module docstring.
2026-08-07 16:38:09 +00:00
..