- DOOR_GENERIC pattern cap (rt_filter=oic.r.door) in fridge.py with key_fn - OVEN_CONNECTED (cloud connectivity) added to oven caps - dryer.py: DRYER_SETTINGS, DRYER_COURSE, JOB_BEGINNING_STATUS, DRYER_DIAGNOSIS - Dishwasher, refrigerator, oven, dryer DeviceRegistry objects fully populated - Refrigerator registry includes DOOR_GENERIC as pattern cap - Oven registry includes OVEN_SETPOINT + OVEN_MODE (safe: no fridge caps in oven registry)
365 lines
12 KiB
Python
365 lines
12 KiB
Python
"""Capabilities for the refrigerator family (Samsung RF9000B-class).
|
|
|
|
Resources verified against the dump at local-tools/dumps/10.0.0.254.json.
|
|
|
|
Temperature fields in all /temperature/* resources are in Fahrenheit on this
|
|
model. Setpoints are NumberDesc with direct-write write_fn (no RMW needed
|
|
because the individual /temperature/desired/* resources take a PUT with just
|
|
the 'temperature' field, unlike the aggregated /temperatures/vs/0 path).
|
|
|
|
Multi-instance note: the two door resources (/door/cooler/0 and
|
|
/door/freezer/0) and the two ice-maker resources (/icemaker/one/vs/0 and
|
|
/icemaker/two/vs/0) use named path segments, so they are modelled as separate
|
|
Capability objects with distinct entity keys rather than a single capability
|
|
replicated via instance_suffix.
|
|
"""
|
|
from ..capability import Capability
|
|
from ..entities import (
|
|
BinarySensorDesc, NumberDesc, SelectDesc, SensorDesc, SwitchDesc,
|
|
)
|
|
|
|
# Setpoint bounds (from /temperatures/vs/0 items on 2026-06-27)
|
|
FREEZER_MIN_F = -8.0
|
|
FREEZER_MAX_F = 5.0
|
|
FRIDGE_MIN_F = 34.0
|
|
FRIDGE_MAX_F = 44.0
|
|
|
|
# Whiskey ball ice sizes.
|
|
ICE2_MODES = ('Off', 'WHISKEY_ICEBALL_3', 'WHISKEY_ICEBALL_6', 'WHISKEY_ICEBALL_9')
|
|
|
|
# Beverage zone flex modes.
|
|
BZONE_MODES = ('SP_TTYPE_BEER_DRINKS', 'SP_TTYPE_WINE_DESSERT')
|
|
|
|
|
|
def _int(v):
|
|
try:
|
|
return int(v)
|
|
except (TypeError, ValueError):
|
|
return None
|
|
|
|
|
|
# ---------------------------------------------------------------------------
|
|
# Temperatures
|
|
# ---------------------------------------------------------------------------
|
|
|
|
def _fridge_setpoint_write(p, rep):
|
|
try:
|
|
temp = int(round(float(p)))
|
|
except (TypeError, ValueError):
|
|
return None
|
|
if not (FRIDGE_MIN_F <= temp <= FRIDGE_MAX_F):
|
|
return None
|
|
return ['temperature', 'desired', 'cooler', '0'], {'temperature': temp}
|
|
|
|
|
|
def _freezer_setpoint_write(p, rep):
|
|
try:
|
|
temp = int(round(float(p)))
|
|
except (TypeError, ValueError):
|
|
return None
|
|
if not (FREEZER_MIN_F <= temp <= FREEZER_MAX_F):
|
|
return None
|
|
return ['temperature', 'desired', 'freezer', '0'], {'temperature': temp}
|
|
|
|
|
|
TEMP_FRIDGE_CURRENT = Capability(
|
|
href='/temperature/current/cooler/0',
|
|
poll_tier='warm',
|
|
entities=(
|
|
SensorDesc(key='fridge_temp_f', field='temperature',
|
|
name='Fridge temperature', device_class='temperature',
|
|
state_class='measurement', unit='°F', value_fn=_int),
|
|
),
|
|
)
|
|
|
|
TEMP_FREEZER_CURRENT = Capability(
|
|
href='/temperature/current/freezer/0',
|
|
poll_tier='warm',
|
|
entities=(
|
|
SensorDesc(key='freezer_temp_f', field='temperature',
|
|
name='Freezer temperature', device_class='temperature',
|
|
state_class='measurement', unit='°F', value_fn=_int),
|
|
),
|
|
)
|
|
|
|
TEMP_FRIDGE_SETPOINT = Capability(
|
|
href='/temperature/desired/cooler/0',
|
|
poll_tier='warm',
|
|
entities=(
|
|
NumberDesc(key='fridge_setpoint_f', field='temperature',
|
|
name='Fridge setpoint', device_class='temperature',
|
|
unit='°F', native_min=FRIDGE_MIN_F, native_max=FRIDGE_MAX_F,
|
|
step=1.0, icon='mdi:thermometer-chevron-up',
|
|
value_fn=_int, write_fn=_fridge_setpoint_write),
|
|
),
|
|
)
|
|
|
|
TEMP_FREEZER_SETPOINT = Capability(
|
|
href='/temperature/desired/freezer/0',
|
|
poll_tier='warm',
|
|
entities=(
|
|
NumberDesc(key='freezer_setpoint_f', field='temperature',
|
|
name='Freezer setpoint', device_class='temperature',
|
|
unit='°F', native_min=FREEZER_MIN_F, native_max=FREEZER_MAX_F,
|
|
step=1.0, icon='mdi:thermometer-chevron-down',
|
|
value_fn=_int, write_fn=_freezer_setpoint_write),
|
|
),
|
|
)
|
|
|
|
# ---------------------------------------------------------------------------
|
|
# Doors
|
|
# ---------------------------------------------------------------------------
|
|
|
|
DOOR_FRIDGE = Capability(
|
|
href='/door/cooler/0',
|
|
poll_tier='hot',
|
|
entities=(
|
|
BinarySensorDesc(key='door_fridge_open', field='openState',
|
|
name='Fridge door', device_class='door',
|
|
value_fn=lambda v: v == 'Open'),
|
|
),
|
|
)
|
|
|
|
DOOR_FREEZER = Capability(
|
|
href='/door/freezer/0',
|
|
poll_tier='hot',
|
|
entities=(
|
|
BinarySensorDesc(key='door_freezer_open', field='openState',
|
|
name='Freezer door', device_class='door',
|
|
value_fn=lambda v: v == 'Open'),
|
|
),
|
|
)
|
|
|
|
DOORS_STATUS = Capability(
|
|
href='/doors/vs/0',
|
|
poll_tier='hot',
|
|
entities=(
|
|
BinarySensorDesc(
|
|
key='any_door_open',
|
|
field='x.com.samsung.da.items',
|
|
name='Any door open',
|
|
device_class='door',
|
|
value_fn=lambda items: any(
|
|
it.get('x.com.samsung.da.openState') == 'Open'
|
|
for it in (items or [])
|
|
),
|
|
),
|
|
),
|
|
)
|
|
|
|
# ---------------------------------------------------------------------------
|
|
# Ice makers
|
|
# ---------------------------------------------------------------------------
|
|
|
|
def _ice1_write(p, rep):
|
|
if p not in ('On', 'Off'):
|
|
return None
|
|
return ['icemaker', 'one', 'vs', '0'], {'x.com.samsung.da.iceMaker.state': p}
|
|
|
|
|
|
def _ice2_type_write(p, rep):
|
|
if p not in ICE2_MODES:
|
|
return None
|
|
return ['icemaker', 'two', 'vs', '0'], {'x.com.samsung.da.iceType.desired': p}
|
|
|
|
|
|
ICEMAKER_ONE = Capability(
|
|
href='/icemaker/one/vs/0',
|
|
poll_tier='warm',
|
|
entities=(
|
|
SensorDesc(key='ice1_state', field='x.com.samsung.da.iceMaker.state',
|
|
name='Ice maker (cubed) state', icon='mdi:cube'),
|
|
BinarySensorDesc(key='ice1_on', field='x.com.samsung.da.iceMaker.state',
|
|
name='Ice maker (cubed) on',
|
|
device_class='running',
|
|
value_fn=lambda v: v == 'On'),
|
|
SensorDesc(key='ice1_making_status',
|
|
field='x.com.samsung.da.iceMaker.iceMakingStatus',
|
|
name='Ice maker (cubed) status', icon='mdi:cube'),
|
|
SwitchDesc(key='ice1', field='x.com.samsung.da.iceMaker.state',
|
|
name='Ice maker (cubed)', icon='mdi:cube',
|
|
value_fn=lambda v: v == 'On',
|
|
write_fn=_ice1_write),
|
|
),
|
|
)
|
|
|
|
ICEMAKER_TWO = Capability(
|
|
href='/icemaker/two/vs/0',
|
|
poll_tier='warm',
|
|
entities=(
|
|
SensorDesc(key='ice2_making_status',
|
|
field='x.com.samsung.da.iceMaker.iceMakingStatus',
|
|
name='Ice maker (whiskey) status', icon='mdi:circle'),
|
|
SelectDesc(key='ice2_type', field='x.com.samsung.da.iceType.desired',
|
|
name='Whiskey ball ice type', icon='mdi:circle',
|
|
options=ICE2_MODES, write_fn=_ice2_type_write),
|
|
),
|
|
)
|
|
|
|
ICEMAKER_STATUS = Capability(
|
|
href='/icemaker/status/vs/0',
|
|
poll_tier='warm',
|
|
entities=(
|
|
SensorDesc(key='ice_maker_enabled', field='x.com.samsung.da.iceMaker',
|
|
name='Ice maker enabled', icon='mdi:snowflake'),
|
|
),
|
|
)
|
|
|
|
# ---------------------------------------------------------------------------
|
|
# Refrigeration modes (rapid cooling)
|
|
# ---------------------------------------------------------------------------
|
|
|
|
def _refrigeration_write(field_name):
|
|
def _write(p, rep):
|
|
if p not in ('On', 'Off'):
|
|
return None
|
|
return ['refrigeration', 'vs', '0'], {field_name: p}
|
|
return _write
|
|
|
|
|
|
REFRIGERATION = Capability(
|
|
href='/refrigeration/vs/0',
|
|
poll_tier='warm',
|
|
entities=(
|
|
SwitchDesc(key='rapid_fridge', field='x.com.samsung.da.rapidFridge',
|
|
name='Rapid fridge', icon='mdi:fridge-industrial',
|
|
value_fn=lambda v: v == 'On',
|
|
write_fn=_refrigeration_write('x.com.samsung.da.rapidFridge')),
|
|
SwitchDesc(key='rapid_freezing', field='x.com.samsung.da.rapidFreezing',
|
|
name='Rapid freezing', icon='mdi:snowflake',
|
|
value_fn=lambda v: v == 'On',
|
|
write_fn=_refrigeration_write('x.com.samsung.da.rapidFreezing')),
|
|
),
|
|
)
|
|
|
|
# ---------------------------------------------------------------------------
|
|
# Autofill
|
|
# ---------------------------------------------------------------------------
|
|
|
|
def _autofill_write(p, rep):
|
|
if p not in ('On', 'Off'):
|
|
return None
|
|
return ['autofill', 'vs', '0'], {'x.com.samsung.da.autofill': p}
|
|
|
|
|
|
AUTOFILL = Capability(
|
|
href='/autofill/vs/0',
|
|
poll_tier='warm',
|
|
entities=(
|
|
SwitchDesc(key='autofill', field='x.com.samsung.da.autofill',
|
|
name='Autofill', icon='mdi:cup-water',
|
|
value_fn=lambda v: v == 'On',
|
|
write_fn=_autofill_write),
|
|
),
|
|
)
|
|
|
|
# ---------------------------------------------------------------------------
|
|
# Cabinet light
|
|
# ---------------------------------------------------------------------------
|
|
|
|
def _cabinet_light_write(p, rep):
|
|
if p not in ('On', 'Off'):
|
|
return None
|
|
return ['cabinet', 'light', 'total', 'vs', '0'], {
|
|
'x.com.samsung.da.lightControl': p,
|
|
}
|
|
|
|
|
|
CABINET_LIGHT = Capability(
|
|
href='/cabinet/light/total/vs/0',
|
|
poll_tier='warm',
|
|
entities=(
|
|
SensorDesc(key='cabinet_light', field='x.com.samsung.da.lightControl',
|
|
name='Cabinet light level', icon='mdi:fridge-outline'),
|
|
BinarySensorDesc(key='cabinet_light_on', field='x.com.samsung.da.lightControl',
|
|
name='Cabinet light on', icon='mdi:fridge-outline',
|
|
value_fn=lambda v: v == 'On'),
|
|
SwitchDesc(key='cabinet_light_switch', field='x.com.samsung.da.lightControl',
|
|
name='Cabinet light', icon='mdi:fridge-outline',
|
|
value_fn=lambda v: v == 'On',
|
|
write_fn=_cabinet_light_write),
|
|
),
|
|
)
|
|
|
|
# ---------------------------------------------------------------------------
|
|
# Sabbath mode
|
|
# ---------------------------------------------------------------------------
|
|
|
|
def _sabbath_write(p, rep):
|
|
if p not in ('On', 'Off'):
|
|
return None
|
|
return ['sabbath', 'vs', '0'], {'x.com.samsung.da.sabbathMode': p}
|
|
|
|
|
|
SABBATH = Capability(
|
|
href='/sabbath/vs/0',
|
|
poll_tier='warm',
|
|
entities=(
|
|
SwitchDesc(key='sabbath_mode', field='x.com.samsung.da.sabbathMode',
|
|
name='Sabbath mode', icon='mdi:star-david',
|
|
value_fn=lambda v: v == 'On',
|
|
write_fn=_sabbath_write),
|
|
),
|
|
)
|
|
|
|
# ---------------------------------------------------------------------------
|
|
# Beverage zone
|
|
# ---------------------------------------------------------------------------
|
|
|
|
def _bzone_write(p, rep):
|
|
if p not in BZONE_MODES:
|
|
return None
|
|
return ['specialzone', 'one', 'vs', '0'], {'roomDesiredMode': p}
|
|
|
|
|
|
BEVERAGE_ZONE = Capability(
|
|
href='/specialzone/one/vs/0',
|
|
poll_tier='warm',
|
|
entities=(
|
|
SelectDesc(key='beverage_zone_mode', field='roomDesiredMode',
|
|
name='Beverage zone mode', icon='mdi:glass-wine',
|
|
options=BZONE_MODES, write_fn=_bzone_write),
|
|
),
|
|
)
|
|
|
|
# ---------------------------------------------------------------------------
|
|
# Firmware update
|
|
# ---------------------------------------------------------------------------
|
|
|
|
FIRMWARE_UPDATE = Capability(
|
|
href='/otninformation/vs/0',
|
|
poll_tier='cold',
|
|
entities=(
|
|
BinarySensorDesc(
|
|
key='firmware_update',
|
|
field='x.com.samsung.da.newVersionAvailable',
|
|
name='Firmware update available',
|
|
device_class='update',
|
|
entity_category='diagnostic',
|
|
value_fn=lambda v: str(v).lower() == 'true' if v is not None else None,
|
|
),
|
|
),
|
|
)
|
|
|
|
# ---------------------------------------------------------------------------
|
|
# Generic door pattern capability (href=None — use as pattern_cap only)
|
|
# ---------------------------------------------------------------------------
|
|
|
|
def _door_key(href: str) -> str:
|
|
# /door/cooler/0 -> door_cooler_open ; /door/wine/0 -> door_wine_open
|
|
segs = [s for s in href.strip('/').split('/') if s and not s.isdigit()]
|
|
return '_'.join(segs) + '_open'
|
|
|
|
|
|
DOOR_GENERIC = Capability(
|
|
href=None,
|
|
rt_filter='oic.r.door',
|
|
poll_tier='hot',
|
|
key_fn=_door_key,
|
|
entities=(
|
|
BinarySensorDesc(key='door_open', field='openState',
|
|