Move the on/off interpretation into a single remote_control_enabled() in registry/capabilities/common.py so the write-guard added in the previous commit can't silently drift from the Smart Control binary sensor's own reading of the same hrefs. Also promotes both /remotectrl hrefs to poll_tier='warm' so the coordinator's cached state backing that write guard doesn't lag up to a full 30s cold summary poll behind the device's actual toggle state.
418 lines
18 KiB
Python
418 lines
18 KiB
Python
"""Capabilities shared across multiple appliance families.
|
|
|
|
Each capability is keyed on the stable OCF resource href (not rt), verified
|
|
against live device dumps:
|
|
/kidslock/vs/0 -> x.com.samsung.da.kidsLock
|
|
/remotectrl/vs/0 -> x.com.samsung.da.remoteControlEnabled
|
|
/power/vs/0 -> x.com.samsung.da.power
|
|
/alarms/vs/0 -> x.com.samsung.da.items
|
|
/energy/consumption/vs/0 -> x.com.samsung.da.instantaneousPower / cumulativePower
|
|
/water/consumption/vs/0 -> x.com.samsung.da.cumulativeWater
|
|
/filter/waterfilter/vs/0 -> x.com.samsung.da.filterUsage / filterStatus
|
|
"""
|
|
from ..capability import Capability
|
|
from ..entities import (
|
|
BinarySensorDesc, ButtonDesc, SelectDesc, SensorDesc, SwitchDesc,
|
|
)
|
|
|
|
|
|
def _num(v):
|
|
try:
|
|
return float(v)
|
|
except (TypeError, ValueError):
|
|
return None
|
|
|
|
|
|
def clamp_power(v):
|
|
n = _num(v)
|
|
return 0.0 if (n is not None and n < 0) else n
|
|
|
|
|
|
def wh_to_kwh(v):
|
|
n = _num(v)
|
|
return round(n / 1000.0, 2) if n is not None else None
|
|
|
|
|
|
def normalize_temp_unit(raw, default='°F'):
|
|
"""'C'/'Celsius' -> '°C', 'F'/'Fahrenheit' -> '°F'. Falls back to
|
|
`default` for any other/missing value. Shared by fridge.py and oven.py,
|
|
both of which read a per-device unit off a `/temperature*` resource
|
|
instead of assuming one (see fridge.py's module docstring, issue #7)."""
|
|
raw = (raw or '').strip().upper()
|
|
if raw.startswith('C'):
|
|
return '°C'
|
|
if raw.startswith('F'):
|
|
return '°F'
|
|
return default
|
|
|
|
|
|
def _ml_to_l(v):
|
|
n = _num(v)
|
|
return round(n / 1000.0, 1) if n is not None else None
|
|
|
|
|
|
def _active_alarm_codes(items):
|
|
if not items or not isinstance(items, list):
|
|
return 'none'
|
|
codes = [i.get('x.com.samsung.da.code') for i in items if i.get('x.com.samsung.da.code')]
|
|
return ', '.join(codes) if codes else 'none'
|
|
|
|
|
|
# OCF-native / vendor '-vs' fallback pairs for power, kids-lock, remote control.
|
|
#
|
|
# These three controls exist as both a standard OCF resource (/power/0,
|
|
# oic.r.switch.binary, plain boolean 'value') and a Samsung vendor resource
|
|
# (/power/vs/0, x.com.samsung.da.power) -- Samsung advertises both as its
|
|
# firmware migrates onto the OCF standard model. Prefer the OCF-standard href
|
|
# when the device exposes it; the '-vs' href (a string-encoded duplicate for
|
|
# these three) binds only when the generic href is absent, via match_fn. Older
|
|
# firmware has only the '-vs' resource, so the pair is behaviour-identical to a
|
|
# lone '-vs' cap there. See the adding-device-support skill's "OCF-standard vs
|
|
# vendor" section for why this is preferred-non-vs-with-fallback, not a blanket
|
|
# choice. Every device registry lists both caps of each pair.
|
|
|
|
POWER_GENERIC = Capability(
|
|
href='/power/0',
|
|
entities=(
|
|
SwitchDesc(key='power_switch', field='value',
|
|
name='Power',
|
|
value_fn=lambda v: bool(v),
|
|
write_fn=lambda p, rep, href=None: (
|
|
['power', '0'], {'value': p == 'On'})),
|
|
),
|
|
)
|
|
|
|
POWER_VS_FALLBACK = Capability(
|
|
href='/power/vs/0',
|
|
match_fn=lambda rep, resources: '/power/0' not in resources,
|
|
entities=(
|
|
SwitchDesc(key='power_switch', field='x.com.samsung.da.power',
|
|
name='Power',
|
|
value_fn=lambda v: v == 'On',
|
|
write_fn=lambda p, rep, href=None: (
|
|
['power', 'vs', '0'],
|
|
{'x.com.samsung.da.power': 'On' if p == 'On' else 'Off'})),
|
|
),
|
|
)
|
|
|
|
KIDS_LOCK_GENERIC = Capability(
|
|
href='/kidslock/0',
|
|
entities=(
|
|
SwitchDesc(key='child_lock', field='value',
|
|
name='Child lock', device_class='lock',
|
|
value_fn=lambda v: bool(v),
|
|
write_fn=lambda p, rep, href=None: (
|
|
['kidslock', '0'], {'value': p == 'On'})),
|
|
),
|
|
)
|
|
|
|
KIDS_LOCK_VS_FALLBACK = Capability(
|
|
href='/kidslock/vs/0',
|
|
match_fn=lambda rep, resources: '/kidslock/0' not in resources,
|
|
entities=(
|
|
SwitchDesc(key='child_lock', field='x.com.samsung.da.kidsLock',
|
|
name='Child lock', device_class='lock',
|
|
value_fn=lambda v: v != 'Ready',
|
|
write_fn=lambda p, rep, href=None: (
|
|
['kidslock', 'vs', '0'],
|
|
{'x.com.samsung.da.kidsLock': 'Enable' if p == 'On' else 'Ready'})),
|
|
),
|
|
)
|
|
|
|
|
|
def remote_control_enabled(resources: dict) -> bool:
|
|
"""Single source of truth for the /remotectrl on/off signal, mirroring
|
|
REMOTE_CONTROL_GENERIC/_VS_FALLBACK's href/field pair and precedence
|
|
below. Used both to render the read-only Smart Control binary_sensor
|
|
(via those two descriptors) and, from coordinator.async_send_command,
|
|
to block writes outright when remote control is off. Both hrefs are
|
|
poll_tier='warm' below so that gate reads recent state (subscribed
|
|
when observe is live, subpolled every ~6s otherwise) rather than a
|
|
once-per-30s cold summary poll. True (assume enabled) when neither
|
|
href is present -- most device types don't report this capability
|
|
at all."""
|
|
generic = resources.get('/remotectrl/0')
|
|
if generic is not None:
|
|
return bool(generic.get('value'))
|
|
fallback = resources.get('/remotectrl/vs/0')
|
|
if fallback is not None:
|
|
return str(fallback.get('x.com.samsung.da.remoteControlEnabled')).lower() == 'true'
|
|
return True
|
|
|
|
|
|
REMOTE_CONTROL_GENERIC = Capability(
|
|
href='/remotectrl/0',
|
|
poll_tier='warm',
|
|
entities=(
|
|
BinarySensorDesc(key='remote_control', field='value',
|
|
name='Smart Control', device_class='connectivity',
|
|
value_fn=lambda v: bool(v)),
|
|
),
|
|
)
|
|
|
|
REMOTE_CONTROL_VS_FALLBACK = Capability(
|
|
href='/remotectrl/vs/0',
|
|
match_fn=lambda rep, resources: '/remotectrl/0' not in resources,
|
|
poll_tier='warm',
|
|
entities=(
|
|
BinarySensorDesc(key='remote_control',
|
|
field='x.com.samsung.da.remoteControlEnabled',
|
|
name='Smart Control', device_class='connectivity',
|
|
value_fn=lambda v: str(v).lower() == 'true'),
|
|
),
|
|
)
|
|
|
|
ALARMS = Capability(
|
|
href='/alarms/vs/0',
|
|
poll_tier='hot',
|
|
entities=(
|
|
SensorDesc(key='alarm_code', field='x.com.samsung.da.items',
|
|
name='Alarm code', icon='mdi:alert',
|
|
entity_category='diagnostic', value_fn=_active_alarm_codes),
|
|
),
|
|
)
|
|
|
|
# instantaneousPower is a dead field on DA_WM_-class laundry dumps (washers and
|
|
# the issue #14 dryer) and on dishwashers too: the literal sentinel '-500',
|
|
# unchanged across off/idle/running. clamp_power floors it to a misleading
|
|
# "0 W" that reads as a real idle measurement. Gate power_watts out when the
|
|
# sentinel is seen -- but only then, so a device reporting a real value (e.g. a
|
|
# fridge's 93 W) still shows it (issue #6). cumulativePower is absent on at
|
|
# least one washer model; the exists_fn makes that explicit rather than relying
|
|
# on the generic field-presence gate.
|
|
_DEAD_INSTANTANEOUS_POWER = '-500'
|
|
|
|
ENERGY_METER = Capability(
|
|
href='/energy/consumption/vs/0',
|
|
entities=(
|
|
# `not rep` keeps the empty-{} stub carve-out (see entity._is_included):
|
|
# an explicit exists_fn otherwise bypasses it, which would drop the
|
|
# entity when /device/0 returns a not-yet-fetched stub. On a populated
|
|
# rep, hide power only for the dead sentinel or an absent field.
|
|
SensorDesc(key='power_watts', field='x.com.samsung.da.instantaneousPower',
|
|
name='Power', device_class='power', state_class='measurement',
|
|
unit='W', value_fn=clamp_power,
|
|
exists_fn=lambda rep, resources: not rep or (
|
|
rep.get('x.com.samsung.da.instantaneousPower')
|
|
not in (None, _DEAD_INSTANTANEOUS_POWER))),
|
|
SensorDesc(key='energy_kwh', field='x.com.samsung.da.cumulativePower',
|
|
name='Energy', device_class='energy',
|
|
state_class='total_increasing', unit='kWh', value_fn=wh_to_kwh,
|
|
exists_fn=lambda rep, resources: (
|
|
not rep or 'x.com.samsung.da.cumulativePower' in rep)),
|
|
# cumulativeConsumption is a second, independently-varying running
|
|
# total alongside cumulativePower -- some fridges (issue #26) report
|
|
# both. Self-gates off where only cumulativePower is present. `not
|
|
# rep or` keeps the same empty-{} stub carve-out as power_watts/
|
|
# energy_kwh above -- without it, an exists_fn permanently drops the
|
|
# entity if setup happens to land on a not-yet-fetched stub.
|
|
SensorDesc(key='power_energy_kwh', field='x.com.samsung.da.cumulativeConsumption',
|
|
name='Power energy', device_class='energy',
|
|
state_class='total_increasing', unit='kWh', value_fn=wh_to_kwh,
|
|
exists_fn=lambda rep, resources: (
|
|
not rep or 'x.com.samsung.da.cumulativeConsumption' in rep)),
|
|
# AI Energy Mode's lifetime savings estimate vs. an unoptimized
|
|
# baseline -- present on some models (e.g. TP1X_REF_21K, issue #21/
|
|
# #27) and absent on others (issue #20/#26), unlike cumulativePower.
|
|
SensorDesc(key='energy_saved_kwh', field='x.com.samsung.da.cumulativeSavedPower',
|
|
name='Energy saved', device_class='energy',
|
|
state_class='total_increasing', unit='kWh', value_fn=wh_to_kwh,
|
|
exists_fn=lambda rep, resources: (
|
|
not rep or 'x.com.samsung.da.cumulativeSavedPower' in rep)),
|
|
# Monthly billing-cycle totals -- the completed prior month and the
|
|
# in-progress current month. Not ever-increasing (each resets at
|
|
# month boundary), so no state_class.
|
|
SensorDesc(key='energy_last_month_kwh', field='x.com.samsung.da.monthlyConsumption',
|
|
name='Energy (last month)', device_class='energy',
|
|
unit='kWh', value_fn=wh_to_kwh,
|
|
exists_fn=lambda rep, resources: (
|
|
not rep or 'x.com.samsung.da.monthlyConsumption' in rep)),
|
|
SensorDesc(key='energy_this_month_kwh', field='x.com.samsung.da.thismonthlyConsumption',
|
|
name='Energy (this month)', device_class='energy',
|
|
unit='kWh', value_fn=wh_to_kwh,
|
|
exists_fn=lambda rep, resources: (
|
|
not rep or 'x.com.samsung.da.thismonthlyConsumption' in rep)),
|
|
),
|
|
)
|
|
|
|
WATER_METER = Capability(
|
|
href='/water/consumption/vs/0',
|
|
entities=(
|
|
SensorDesc(key='water_liters', field='x.com.samsung.da.cumulativeWater',
|
|
name='Water consumption', device_class='water',
|
|
state_class='total_increasing', unit='L', icon='mdi:water',
|
|
value_fn=_ml_to_l),
|
|
),
|
|
)
|
|
|
|
WATER_FILTER = Capability(
|
|
href='/filter/waterfilter/vs/0',
|
|
match_fn=lambda rep, _: rep.get('x.com.samsung.da.filterStatus', '').lower() != 'notused',
|
|
entities=(
|
|
SensorDesc(key='filter_usage', field='x.com.samsung.da.filterUsage',
|
|
name='Filter usage', unit='%', state_class='measurement',
|
|
icon='mdi:filter'),
|
|
SensorDesc(key='filter_status', field='x.com.samsung.da.filterStatus',
|
|
name='Filter status', icon='mdi:filter-check'),
|
|
),
|
|
)
|
|
|
|
# AI energy-saving level -- '0' is off, and supportedAiLevel lists the
|
|
# additional level(s) the device offers ('1' meaning just "on" on most
|
|
# hardware, but multi-level boards have been reported). Verified cross-family:
|
|
# fridge (issue #21) and washer (issue #40) both expose this href.
|
|
#
|
|
# supportedAiLevel is a single-entry list on most captured hardware, where a
|
|
# select would offer only one real choice against an implicit "off" -- shown
|
|
# as a switch instead. '0' itself is never in supportedAiLevel but has been
|
|
# observed live as the off value of aiLevel, so the select synthesizes it
|
|
# back in as an explicit option rather than leaving no way to turn off.
|
|
#
|
|
# No translation_key: aiLevel's values are plain digit strings, and
|
|
# select.py's _display() already renders an untranslated numeric string
|
|
# as-is -- there's nothing a strings.json entry adds that's worth maintaining
|
|
# against an unknown, growing number of future levels.
|
|
|
|
|
|
def _ai_energy_supported_levels(rep):
|
|
"""supportedAiLevel as a list -- a stray scalar (e.g. a string) must not
|
|
be len()-checked as if it were a list."""
|
|
sl = rep.get('supportedAiLevel')
|
|
return list(sl) if isinstance(sl, (list, tuple)) else []
|
|
|
|
|
|
def _ai_energy_level_options(resources):
|
|
rep = resources.get('/energy/ailevel/vs/0') or {}
|
|
return ['0', *_ai_energy_supported_levels(rep)]
|
|
|
|
|
|
def _ai_energy_level_write(p, rep, href=None):
|
|
return ['energy', 'ailevel', 'vs', '0'], {'aiLevel': p}
|
|
|
|
|
|
def _ai_energy_level_switch_write(p, rep, href=None):
|
|
levels = _ai_energy_supported_levels(rep)
|
|
on_level = levels[0] if levels else '1'
|
|
return ['energy', 'ailevel', 'vs', '0'], {'aiLevel': on_level if p == 'On' else '0'}
|
|
|
|
|
|
AI_ENERGY_LEVEL = Capability(
|
|
href='/energy/ailevel/vs/0',
|
|
poll_tier='cold',
|
|
entities=(
|
|
# No `not rep` stub carve-out on either side, unlike most exists_fn
|
|
# gates in this file -- entity creation only ever runs once, against
|
|
# whichever snapshot happens to be current the moment platforms are
|
|
# set up (see entity._is_included / __init__.py's
|
|
# async_config_entry_first_refresh-before-forward-entry-setups
|
|
# ordering), while flatten() re-evaluates exists_fn every poll
|
|
# against live data. Both descriptors share key='ai_energy_level',
|
|
# so if a stub carve-out let one of them win at setup time while the
|
|
# other wins once real data lands, flatten() would feed the
|
|
# instantiated entity a value shaped for the other platform (e.g. a
|
|
# bool into a Select). Requiring real, populated data on both sides
|
|
# keeps the entity-creation decision and the live-value decision in
|
|
# permanent agreement -- the cost is this entity doesn't appear
|
|
# until a reload if the device's very first poll stubs this
|
|
# cold-tier href, the same reload already required to fix which
|
|
# platform got picked in that case.
|
|
SwitchDesc(key='ai_energy_level', field='aiLevel',
|
|
name='AI energy level', icon='mdi:leaf',
|
|
entity_category='config',
|
|
value_fn=lambda v: v != '0',
|
|
exists_fn=lambda rep, resources: (
|
|
len(_ai_energy_supported_levels(rep)) == 1),
|
|
write_fn=_ai_energy_level_switch_write),
|
|
SelectDesc(key='ai_energy_level', field='aiLevel',
|
|
name='AI energy level', icon='mdi:leaf',
|
|
entity_category='config',
|
|
options=_ai_energy_level_options,
|
|
exists_fn=lambda rep, resources: (
|
|
len(_ai_energy_supported_levels(rep)) > 1),
|
|
write_fn=_ai_energy_level_write),
|
|
),
|
|
)
|
|
|
|
FIRMWARE_UPDATE = Capability(
|
|
href='/otninformation/vs/0',
|
|
poll_tier='cold',
|
|
entities=(
|
|
BinarySensorDesc(
|
|
key='firmware_update',
|
|
field='x.com.samsung.da.newVersionAvailable',
|
|
name='Firmware update available',
|
|
device_class='update',
|
|
entity_category='diagnostic',
|
|
value_fn=lambda v: str(v).lower() == 'true' if v is not None else None,
|
|
),
|
|
),
|
|
)
|
|
|
|
SELF_CHECK = Capability(
|
|
href='/selfcheck/vs/0',
|
|
poll_tier='cold',
|
|
entities=(
|
|
SensorDesc(key='selfcheck_status', field='x.com.samsung.da.status',
|
|
name='Self-check status', icon='mdi:stethoscope',
|
|
entity_category='diagnostic'),
|
|
SensorDesc(key='selfcheck_result', field='x.com.samsung.da.result',
|
|
name='Self-check result', icon='mdi:clipboard-check-outline',
|
|
entity_category='diagnostic'),
|
|
# List of error codes from the last self-check; joined for display.
|
|
# Not every fridge reports the field, hence the exists_fn.
|
|
SensorDesc(key='selfcheck_error', field='x.com.samsung.da.error',
|
|
name='Self-check error', icon='mdi:alert-circle-outline',
|
|
entity_category='diagnostic',
|
|
exists_fn=lambda rep, resources: (
|
|
not rep or 'x.com.samsung.da.error' in rep),
|
|
value_fn=lambda v: (', '.join(v) if v else None) if isinstance(v, list) else v),
|
|
ButtonDesc(key='selfcheck_start', field='', name='Start self-check',
|
|
payload='Start', icon='mdi:play-circle-outline',
|
|
entity_category='diagnostic',
|
|
write_fn=lambda p, rep, href=None: (
|
|
['selfcheck', 'vs', '0'], {'x.com.samsung.da.status': p})),
|
|
),
|
|
)
|
|
|
|
# ---------------------------------------------------------------------------
|
|
# Cross-family bundles, unpacked into every by_type registry's _build([...])
|
|
# call the same way ignored.IGNORED is (*common.UNIVERSAL / *common.POWER).
|
|
# discover() only binds a capability whose href is actually present in a
|
|
# given device's resource dump, so listing one here for a family that
|
|
# doesn't expose the href is a no-op, not a phantom entity -- see the
|
|
# adding-device-support skill's coverage-discipline section.
|
|
#
|
|
# UNIVERSAL holds every capability with no known family that both (a) has
|
|
# the href and (b) needs to model it some other way -- broadening one of
|
|
# these to a new family is a safe, harmless guess (issue #40's AI energy
|
|
# level: 2 of 6 families confirmed, blanket-added everywhere else).
|
|
#
|
|
# POWER is kept separate -- airconditioner is the one family that opts out
|
|
# of it. Canonical reason (see by_type/airconditioner.py and its test for
|
|
# pointers back here, not restatements): AC's climate entity already owns
|
|
# /power/0 and /power/vs/0 via bare, no-entity Capability objects
|
|
# (airconditioner.COVERAGE), and a second, real POWER_GENERIC/
|
|
# POWER_VS_FALLBACK cap on the same href would make _build() raise (a href
|
|
# with >1 cap must have every cap discriminated by rt_filter/match_fn, and
|
|
# the bare COVERAGE cap has neither). Kids-lock/remote-control don't have
|
|
# this conflict -- no AC dump has ever reported those hrefs -- so they stay
|
|
# in UNIVERSAL.
|
|
# ---------------------------------------------------------------------------
|
|
|
|
UNIVERSAL = (
|
|
ALARMS,
|
|
ENERGY_METER,
|
|
FIRMWARE_UPDATE,
|
|
SELF_CHECK,
|
|
AI_ENERGY_LEVEL,
|
|
KIDS_LOCK_GENERIC,
|
|
KIDS_LOCK_VS_FALLBACK,
|
|
REMOTE_CONTROL_GENERIC,
|
|
REMOTE_CONTROL_VS_FALLBACK,
|
|
)
|
|
|
|
POWER = (
|
|
POWER_GENERIC,
|
|
POWER_VS_FALLBACK,
|
|
)
|