Files
localthings/tests/test_airconditioner_capabilities.py
T
Marc Billow 8e25e6dc71 Recognize A-CAWW-TP2-20-COMMON system air conditioners (issue #52)
New '-CAWW-' modelNum token for multi-indoor-unit commercial AC
installs -- these report no oneUiVersion, same as the other RAC/PRAC
boards. Once routed to the existing airconditioner registry, every
resource in the reporter's dump already binds except one new
SAC-specific installation-topology blob, now ignored.
2026-07-24 04:06:31 +00:00

260 lines
10 KiB
Python

"""Tests for Samsung air-conditioner support (issue #17).
These stay HA-free like the rest of the suite: they exercise the registry,
discovery/flatten, and the CLIMATE capability's write contract. The composite
climate entity itself lives in climate.py (imports homeassistant) and is not
importable here -- consistent with how the other HA platform files are untested.
"""
from custom_components.localthings.registry.adapter import flatten
from custom_components.localthings.registry.by_type import for_device, for_device_by_model
from custom_components.localthings.registry.capabilities import airconditioner
from custom_components.localthings.registry.discovery import discover
from custom_components.localthings.registry.entities import ClimateDesc
from tests.conftest import _load_device
def _ac():
resources = _load_device('airconditioner')
info = resources['/information/vs/0']
reg = for_device_by_model(
info['x.com.samsung.da.modelNum'], info['x.com.samsung.da.description'],
)
return reg, resources
def _resolve(name):
"""Mirror the coordinator's detection order: oneUiVersion first, modelNum
fallback second (needed for issue #37's board, which reports neither
oneUiVersion nor a '_PRAC_' modelNum token)."""
resources = _load_device(name)
otn = resources.get('/otninformation/vs/0', {})
one_ui = otn.get('swVersionInfo', {}).get('oneUiVersion', '')
info = resources['/information/vs/0']
reg = for_device(one_ui) if one_ui else None
if reg is None:
reg = for_device_by_model(
info['x.com.samsung.da.modelNum'], info['x.com.samsung.da.description'],
)
return reg, resources
def _bound():
reg, resources = _ac()
return discover(resources, reg.capabilities, reg.pattern_capabilities), resources
def _state():
bound, resources = _bound()
return flatten(bound, resources)
def test_ac_model_resolves_to_airconditioner_registry():
reg, _ = _ac()
assert reg is not None and reg.name == 'airconditioner'
def test_no_unbound_hrefs():
"""Every resource in the issue #17 dump binds or is covered -- clears the
coverage-gap repair."""
reg, resources = _ac()
unbound = []
discover(resources, reg.capabilities, reg.pattern_capabilities, log=unbound.append)
assert unbound == []
def test_climate_entity_is_bound():
"""The composite climate entity binds the primary /mode/vs/0 resource."""
bound, _ = _bound()
climate = [b for b in bound if isinstance(b.desc, ClimateDesc)]
assert len(climate) == 1
assert climate[0].href == '/mode/vs/0'
def test_expected_state_keys_present():
state = _state()
for key in ('climate', 'air_purify', 'auto_clean', 'air_filter_status',
'air_filter_usage', 'diagnosis_status', 'alarm_code', 'energy_kwh'):
assert key in state, key
def test_power_and_convenient_folded_into_climate():
"""On/off is the climate entity's HVACMode.OFF and convenient mode is its
preset_mode -- neither surfaces as a standalone switch/select."""
state = _state()
assert 'power_switch' not in state
assert 'convenient_mode' not in state
def test_air_filter_usage_is_percentage_of_capacity():
"""filterUsage is a raw count in the capacity unit (100 of 500), surfaced as
a percentage rather than the misleading raw value."""
assert _state()['air_filter_usage'] == 20
def test_climate_write_targets():
"""The CLIMATE write_fn maps each (kind, value) command to the right OCF
POST target and body. `value` is already the raw device code."""
write = airconditioner.CLIMATE.entities[0].write_fn
assert write(('power', True), {}) == (['power', '0'], {'value': True})
assert write(('power', False), {}) == (['power', '0'], {'value': False})
assert write(('mode', 'Heat'), {}) == (
['mode', 'vs', '0'], {'x.com.samsung.da.modes': ['Heat']})
assert write(('temperature', 23.6), {}) == (
['temperature', 'desired', '0'], {'temperature': 24})
assert write(('fan', '2'), {}) == (
['wind', 'strength', 'vs', '0'], {'x.com.samsung.da.modes': '2'})
assert write(('swing', 'All'), {}) == (
['wind', 'direction', 'vs', '0'], {'x.com.samsung.da.modes': 'All'})
assert write(('preset', 'Sleep'), {}) == (
['mode', 'convenient', 'vs', '0'], {'x.com.samsung.da.modes': 'Sleep'})
assert write(('bogus', 1), {}) is None
def test_climate_consumed_hrefs_declared_as_coverage():
"""The climate-consumed and ambiguous hrefs are declared in the AC registry
(as no-entity coverage caps) so they don't leak as gaps -- but produce no
standalone entities."""
reg, _ = _ac()
for href in ('/power/0', '/power/vs/0', '/temperature/desired/0',
'/wind/strength/vs/0', '/mode/convenient/vs/0',
'/temperatures/vs/0', '/sensors/vs/0', '/humidity/0'):
caps = reg.capabilities.get(href)
assert caps, href
assert all(c.entities == () for c in caps), href
# ---------------------------------------------------------------------------
# TP1X_DA-AC-RAC-01011 (oneUiVersion "7.0 Air conditioner", Tizen Lite) -- a
# newer model class than the ARTIK051_PRAC dump above. It has no OCF-standard
# /temperature/current+desired pair (temperature lives on the vendor
# /temperatures/vs/0 items[] resource), exposes a /light/vs/0 display light, and
# carries extra vendor housekeeping hrefs. Issue #17 for this class (PR #36).
# ---------------------------------------------------------------------------
def _ac_tp1x():
resources = _load_device('airconditioner_tp1x_da_ac_rac_01011')
one_ui = resources['/otninformation/vs/0']['swVersionInfo']['oneUiVersion']
return for_device(one_ui), resources
def test_tp1x_resolves_to_airconditioner_registry():
reg, _ = _ac_tp1x()
assert reg is not None and reg.name == 'airconditioner'
def test_tp1x_no_unbound_hrefs():
"""Every resource in the TP1X dump binds or is covered -- including
/temperatures/vs/0, /light/vs/0 and the housekeeping hrefs absent from
the ARTIK051 dump. Clears the coverage-gap repair."""
reg, resources = _ac_tp1x()
unbound = []
discover(resources, reg.capabilities, reg.pattern_capabilities, log=unbound.append)
assert unbound == []
def test_tp1x_display_light_switch_present():
"""/light/vs/0 (mode On/Off) surfaces as the display-light switch."""
reg, resources = _ac_tp1x()
state = flatten(
discover(resources, reg.capabilities, reg.pattern_capabilities), resources)
assert state.get('display_light') is True # device reports mode == 'On'
def test_tp1x_vendor_temperature_and_light_covered():
"""The vendor temperature resource (read by the climate entity) and the
display-light resource both resolve in the registry -- no gap."""
reg, _ = _ac_tp1x()
assert reg.capabilities.get('/temperatures/vs/0'), '/temperatures/vs/0'
assert reg.capabilities.get('/light/vs/0'), '/light/vs/0'
def test_tp1x_climate_entity_is_bound():
"""The composite climate entity still binds the primary /mode/vs/0."""
reg, resources = _ac_tp1x()
bound = discover(resources, reg.capabilities, reg.pattern_capabilities)
climate = [b for b in bound if isinstance(b.desc, ClimateDesc)]
assert len(climate) == 1 and climate[0].href == '/mode/vs/0'
def test_tp2x_rac_20k_model_resolves_via_model_fallback():
"""TP2X_RAC_20K (issue #37) reports no oneUiVersion and no '_PRAC_' token
-- resolved via the '_RAC_' modelNum fallback added for this device."""
reg, _ = _resolve('airconditioner_tp2x_rac_20k')
assert reg is not None and reg.name == 'airconditioner'
def test_tp2x_rac_20k_no_unbound_hrefs():
reg, resources = _resolve('airconditioner_tp2x_rac_20k')
unbound = []
discover(resources, reg.capabilities, reg.pattern_capabilities, log=unbound.append)
assert unbound == []
def test_tp1x_rac_model_resolves_via_one_ui_version():
"""TP1X_DA-AC-RAC-01001_0000 (issue #38) self-reports oneUiVersion
'7.0 Air conditioner' -- resolved via for_device(), not the modelNum
fallback."""
reg, _ = _resolve('airconditioner_tp1x_rac')
assert reg is not None and reg.name == 'airconditioner'
def test_tp1x_rac_no_unbound_hrefs():
reg, resources = _resolve('airconditioner_tp1x_rac')
unbound = []
discover(resources, reg.capabilities, reg.pattern_capabilities, log=unbound.append)
assert unbound == []
def test_tp1x_rac_expected_state_keys_present():
reg, resources = _resolve('airconditioner_tp1x_rac')
bound = discover(resources, reg.capabilities, reg.pattern_capabilities)
state = flatten(bound, resources)
for key in ('climate', 'display_light', 'mute_once', 'selfcheck_status',
'selfcheck_result', 'current_limit_enabled', 'current_limit_level'):
assert key in state, key
def test_caww_tp2_model_resolves_via_model_fallback():
"""A-CAWW-TP2-20-COMMON (issue #52, System AC) reports no oneUiVersion
and no '_RAC_'/'_PRAC_' token -- resolved via the '-CAWW-' modelNum
fallback added for this device."""
reg, _ = _resolve('airconditioner_caww_tp2')
assert reg is not None and reg.name == 'airconditioner'
def test_caww_tp2_no_unbound_hrefs():
"""Every resource in the issue #52 dump binds or is ignored -- clears
the coverage-gap repair. Only new href beyond the existing RAC/PRAC
surface is /sac/installationinfo/vs/0 (opaque SAC installation topology,
ignored)."""
reg, resources = _resolve('airconditioner_caww_tp2')
unbound = []
discover(resources, reg.capabilities, reg.pattern_capabilities, log=unbound.append)
assert unbound == []
def test_caww_tp2_sac_installationinfo_is_ignored():
ignored_hrefs = {cap.href for cap in airconditioner.COVERAGE}
assert '/sac/installationinfo/vs/0' in ignored_hrefs
def test_mute_once_write_target():
write = airconditioner.MUTE_ONCE.entities[0].write_fn
assert write('On', {}) == (['option', 'muteonce', 'vs', '0'], {'muteonce': 'On'})
assert write('Off', {}) == (['option', 'muteonce', 'vs', '0'], {'muteonce': 'Off'})
def test_display_light_write_target():
write = airconditioner.DISPLAY_LIGHT.entities[0].write_fn
assert write('On', {}) == (['light', 'vs', '0'], {'mode': 'On'})
assert write('Off', {}) == (['light', 'vs', '0'], {'mode': 'Off'})
def test_current_limit_is_read_only():
"""Meaning/write contract for the current-limit levels isn't confirmed
from the dump alone -- exposed as read-only diagnostic sensors rather
than a guessed writable control."""
for desc in airconditioner.CURRENT_LIMIT.entities:
assert getattr(desc, 'write_fn', None) is None