A live dump showed DrumCleanLog_'s newest entry moving every 30-90s on its own, including well after a cycle had already finished -- it never settles on a value worth showing. drum_clean_cycles_remaining, read from separate WashingTimes_/DrumCleanProposal_ counters, is unaffected and stays wired. The washer/dryer readers this was originally built from (issues #9, #258) aren't touched -- no report of the same churn there.
132 lines
4.9 KiB
Python
132 lines
4.9 KiB
Python
"""Capabilities specific to dishwasher appliances (DW9000F-class).
|
|
|
|
Resources verified against the live device dump at 10.0.0.129.
|
|
|
|
The /course/vs/0 cycle select and its options-array machinery are shared with
|
|
washer and dryer in laundry.py; only the dishwasher-specific options (storm
|
|
wash, auto release dry) are read locally here.
|
|
"""
|
|
|
|
from ..capability import Capability
|
|
from ..entities import ButtonDesc, SelectDesc, SensorDesc, SwitchDesc
|
|
from .common import diagnosis_status
|
|
from .laundry import (
|
|
bool_option_switch,
|
|
cycle_select,
|
|
drum_clean_cycles_remaining,
|
|
)
|
|
|
|
# ---------------------------------------------------------------------------
|
|
# /dishwasher/vs/0 — cycle wash/dry settings
|
|
# ---------------------------------------------------------------------------
|
|
|
|
DISHWASHER_SETTINGS = Capability(
|
|
href="/dishwasher/vs/0",
|
|
entities=(
|
|
SwitchDesc(
|
|
key="sanitize",
|
|
field="x.com.samsung.da.sanitize",
|
|
icon="mdi:bacteria",
|
|
value_fn=lambda v: v == "On",
|
|
write_fn=lambda p, rep, href=None: (
|
|
["dishwasher", "vs", "0"],
|
|
{"x.com.samsung.da.sanitize": "On" if p == "On" else "Off"},
|
|
),
|
|
),
|
|
SelectDesc(
|
|
key="heated_dry",
|
|
field="x.com.samsung.da.heatedDry",
|
|
icon="mdi:heat-wave",
|
|
options_field="x.com.samsung.da.supportedHeatedDry",
|
|
write_fn=lambda p, rep, href=None: (
|
|
["dishwasher", "vs", "0"],
|
|
{"x.com.samsung.da.heatedDry": p},
|
|
),
|
|
),
|
|
),
|
|
)
|
|
|
|
# /course/vs/0 -- cycle selection (shared laundry.cycle_select) plus the
|
|
# dishwasher-only StormWashZone / AutoDoorRelease toggles riding in the same
|
|
# options array (shared laundry.bool_option_switch). Course display names
|
|
# live in translations under entity.select.dishwasher_cycle.
|
|
#
|
|
# '83'/'86' were transposed in that catalog until issue #226: the original
|
|
# fixture's own live editCourseList puts them back to back, exactly the
|
|
# kind of adjacent pair a manual screenshot transcription slips on. The
|
|
# reporter's live confirmation (selecting 'Normal' ran the physical Express
|
|
# 60 program and vice versa) settled it: '86' is Express 60, '83' is Normal.
|
|
#
|
|
# Drum Clean+ maintenance tracking reuses washer.py/dryer.py's (issues #9,
|
|
# #258) DrumCleanProposal_/WashingTimes_/DrumCleanLog_ tokens riding on this
|
|
# same options[] array -- a live dump confirmed the dishwasher reports the
|
|
# identical trio (WashingTimes_18/DrumCleanProposal_20, plus a '|'-joined
|
|
# DrumCleanLog_ history matching the dryer's multi-entry shape), so
|
|
# laundry.drum_clean_cycles_remaining applies unchanged.
|
|
#
|
|
# laundry.drum_clean_last_cleaned (DrumCleanLog_'s own newest entry) is
|
|
# deliberately NOT wired up here (issue #398): a live dishwasher dump
|
|
# showed it moving every 30-90s on its own, including well after a cycle
|
|
# had already finished -- unlike the washer/dryer reports this reader was
|
|
# built from (issues #9, #258), it never settles on a value worth showing.
|
|
|
|
CYCLE_OPTIONS = Capability(
|
|
href="/course/vs/0",
|
|
entities=(
|
|
cycle_select(translation_key="dishwasher_cycle", icon="mdi:dishwasher"),
|
|
bool_option_switch("storm_wash", "mdi:weather-lightning-rainy", "StormWashZone"),
|
|
bool_option_switch(
|
|
"auto_release_dry", "mdi:door-open", "AutoDoorRelease", gate_on_presence=True
|
|
),
|
|
SensorDesc(
|
|
key="drum_clean_cycles_remaining",
|
|
unit="cycles",
|
|
icon="mdi:dishwasher-alert",
|
|
state_class="measurement",
|
|
exists_fn=lambda rep, resources: drum_clean_cycles_remaining(rep) is not None,
|
|
rep_fn=drum_clean_cycles_remaining,
|
|
),
|
|
),
|
|
)
|
|
|
|
# ---------------------------------------------------------------------------
|
|
# Self-diagnostic trigger and last-operation-source sensor
|
|
# ---------------------------------------------------------------------------
|
|
|
|
DIAGNOSIS = Capability(
|
|
href="/diagnosis/vs/0",
|
|
poll_tier="cold",
|
|
entities=(
|
|
SensorDesc(
|
|
key="diagnosis_status",
|
|
field="x.com.samsung.da.diagnosisStart",
|
|
icon="mdi:stethoscope",
|
|
entity_category="diagnostic",
|
|
device_class="enum",
|
|
options=("ready",),
|
|
value_fn=diagnosis_status,
|
|
),
|
|
ButtonDesc(
|
|
key="diagnosis_start",
|
|
field="",
|
|
payload="Start",
|
|
icon="mdi:play-circle-outline",
|
|
entity_category="diagnostic",
|
|
write_fn=lambda p, rep, href=None: (
|
|
["diagnosis", "vs", "0"],
|
|
{"x.com.samsung.da.diagnosisStart": p},
|
|
),
|
|
),
|
|
),
|
|
)
|
|
|
|
OPERATION_ORIGIN = Capability(
|
|
href="/operation/origin/vs/0",
|
|
poll_tier="cold",
|
|
entities=(
|
|
SensorDesc(
|
|