Marc Billow 39dcf6a7b8 Drop unexplained Blooming_* diagnostic, confirm remaining air purifier fields (issue #56)
Per the five running-state diagnostics dumps (Auto/Sleep/Low/Medium/High)
gathered in the issue thread:
- Blooming_* has no corresponding SmartThings app setting, so it's dropped
  entirely rather than kept as an unexplained diagnostic.
- Comode_* reads 'Off' on all five, ruling out the original guess that it
  was the fan-speed selector -- still exposed read-only, purpose unconfirmed.
- OptionCode_60282 and the missing humidity sensor are confirmed correct as
  already modeled.
- /airflow's speed doesn't map monotonically to the five settings and the
  dumps were all captured within one ~30s poll cycle of each other, so it
  stays read-only pending a cleaner, time-spaced capture.

FilterProgress is untouched here: an earlier pass on this issue read the
thread as confirming 100 means "fresh" and renamed the sensor to filter_life
to match, but that reading was backwards -- the reporter clarified 100
means fully used and needs replacing, which is what filter_progress (the
already-shipped name) already implies. That rename was caught before
merging and is not part of this change.