Files
localthings/custom_components/localthings/registry/capabilities/dishwasher.py
T
Marc Billow 7086b134c0 Add code comment guidelines; dramatically trim excessive comments
CONTRIBUTING.md gains a "Code comments" section: comment the why not
the what, keep it to a sentence or two with a pointer to the load-bearing
evidence, don't re-derive a sibling's already-documented reasoning, and
move failed-attempt investigation logs out of inline comments.

Applied that policy across the codebase: condensed sprawling module
docstrings, per-entity essays, and multi-paragraph rationale blocks down
to their load-bearing conclusions, while preserving the actual "why"
(issue numbers, calibration evidence, gotchas, don't-guess rationale).
No functional code changed — verified via diff review, ruff, ty, and the
full pytest suite (1211 passed).

One inline investigation log (the AC filter-reset "tried and failed"
notes) moved to docs/investigations/ac-filter-reset.md rather than being
deleted, per the new guideline on where that kind of record belongs.
2026-08-05 01:24:17 +00:00

103 lines
3.6 KiB
Python

"""Capabilities specific to dishwasher appliances (DW9000F-class).
Resources verified against the live device dump at 10.0.0.129.
The /course/vs/0 cycle select and its options-array machinery are shared with
washer and dryer in laundry.py; only the dishwasher-specific options (storm
wash, auto release dry) are read locally here.
"""
from ..capability import Capability
from ..entities import ButtonDesc, SelectDesc, SensorDesc, SwitchDesc
from .laundry import bool_option_switch, cycle_select
# ---------------------------------------------------------------------------
# /dishwasher/vs/0 — cycle wash/dry settings
# ---------------------------------------------------------------------------
DISHWASHER_SETTINGS = Capability(
href="/dishwasher/vs/0",
entities=(
SwitchDesc(
key="sanitize",
field="x.com.samsung.da.sanitize",
icon="mdi:bacteria",
value_fn=lambda v: v == "On",
write_fn=lambda p, rep, href=None: (
["dishwasher", "vs", "0"],
{"x.com.samsung.da.sanitize": "On" if p == "On" else "Off"},
),
),
SelectDesc(
key="heated_dry",
field="x.com.samsung.da.heatedDry",
icon="mdi:heat-wave",
options_field="x.com.samsung.da.supportedHeatedDry",
write_fn=lambda p, rep, href=None: (
["dishwasher", "vs", "0"],
{"x.com.samsung.da.heatedDry": p},
),
),
),
)
# /course/vs/0 -- cycle selection (shared laundry.cycle_select) plus the
# dishwasher-only StormWashZone / AutoDoorRelease toggles riding in the same
# options array (shared laundry.bool_option_switch). Course display names
# live in translations under entity.select.dishwasher_cycle.
#
# '83'/'86' were transposed in that catalog until issue #226: the original
# fixture's own live editCourseList puts them back to back, exactly the
# kind of adjacent pair a manual screenshot transcription slips on. The
# reporter's live confirmation (selecting 'Normal' ran the physical Express
# 60 program and vice versa) settled it: '86' is Express 60, '83' is Normal.
CYCLE_OPTIONS = Capability(
href="/course/vs/0",
entities=(
cycle_select(translation_key="dishwasher_cycle", icon="mdi:dishwasher"),
bool_option_switch("storm_wash", "mdi:weather-lightning-rainy", "StormWashZone"),
bool_option_switch(
"auto_release_dry", "mdi:door-open", "AutoDoorRelease", gate_on_presence=True
),
),
)
# ---------------------------------------------------------------------------
# Self-diagnostic trigger and last-operation-source sensor
# ---------------------------------------------------------------------------
DIAGNOSIS = Capability(
href="/diagnosis/vs/0",
poll_tier="cold",
entities=(
SensorDesc(
key="diagnosis_status",
field="x.com.samsung.da.diagnosisStart",
icon="mdi:stethoscope",
entity_category="diagnostic",
),
ButtonDesc(
key="diagnosis_start",
field="",
payload="Start",
icon="mdi:play-circle-outline",
entity_category="diagnostic",
write_fn=lambda p, rep, href=None: (
["diagnosis", "vs", "0"],
{"x.com.samsung.da.diagnosisStart": p},
),
),
),
)
OPERATION_ORIGIN = Capability(
href="/operation/origin/vs/0",
poll_tier="cold",
entities=(
SensorDesc(
key="operation_origin", field="origin", icon="mdi:remote", entity_category="diagnostic"
),
),
)