Marc Billow eeece4906c Type air_monitor's particulates and migrate the recorded statistics
Adding a unit to a sensor that recorded long-term statistics without one
is not cosmetic: Home Assistant raises a units_changed repair and then
*suppresses statistics generation* for that entity until a human resolves
it (sensor/recorder.py's compile path hits `continue`). Shipping the PM
device classes on their own would therefore have silently frozen the very
history the labels were meant to describe.

A v2 -> v3 config-entry migration relabels the statistics metadata first.
It rewrites only the metadata row, never the recorded values -- these
readings were always µg/m³ and only the label was missing, so nothing
needs converting, which is why this uses async_update_statistics_metadata
and not change_statistics_unit. It reads entity_ids back off the entity
registry rather than rebuilding them from descriptor keys, since a renamed
entity's statistic_id no longer follows from its key, and it is scoped by
device family: range_hood and airconditioner still declare no unit for
their identically-named sensors, so relabelling theirs would create the
exact mismatch this exists to prevent.

With the migration in place there is no longer a reason to hold the labels
back on air_monitor, so it takes them too. That board is one of the two
whose fixtures pin the grade bands the mapping rests on -- typing the
purifier and not the monitor was an inconsistency, not caution. It still
declines the shared state_class column, unchanged.

Recorder coupling is guarded: after_dependencies pulls it in when
configured, the import is local to the migration, and a setup without it
is a no-op. Freshly created entries mint v3 directly, having no history to
relabel.

Tested at both levels. The unit-level tests patch the recorder and assert
which entities are relabelled with which arguments, covering the renamed
entity, subdevice-prefixed and instanced keys, the near-miss keys
(dustbag_/dustbin_), the skipped families and the recorder-absent path.
Because a mock can only prove the call is made, not that it does what the
migration needs, a second suite drives a real in-memory recorder end to
end: statistics seeded unitless, migration run, metadata confirmed to read
µg/m³ / concentration, recorded means confirmed byte-identical, and the
units_changed issue confirmed present before and absent after.
2026-08-15 01:01:49 +00:00

18 lines
448 B
JSON

{
"domain": "localthings",
"name": "LocalThings",
"after_dependencies": ["recorder"],
"codeowners": ["@mbillow"],
"config_flow": true,
"dependencies": [],
"documentation": "https://github.com/mbillow/localthings",
"iot_class": "local_push",
"issue_tracker": "https://github.com/mbillow/localthings/issues",
"requirements": [
"cbor2>=5.4.6",
"pyOpenSSL>=23.0",
"smartthings-local>=0.1.6"
],
"version": "0.21.2"
}