Files
localthings/samsung_appliance/registry/capabilities/oven.py
T
Marc Billow 1b36ec4a59 feat: fill per-device-type registries; add DOOR_GENERIC, OVEN_CONNECTED, dryer caps
- DOOR_GENERIC pattern cap (rt_filter=oic.r.door) in fridge.py with key_fn
- OVEN_CONNECTED (cloud connectivity) added to oven caps
- dryer.py: DRYER_SETTINGS, DRYER_COURSE, JOB_BEGINNING_STATUS, DRYER_DIAGNOSIS
- Dishwasher, refrigerator, oven, dryer DeviceRegistry objects fully populated
- Refrigerator registry includes DOOR_GENERIC as pattern cap
- Oven registry includes OVEN_SETPOINT + OVEN_MODE (safe: no fridge caps in oven registry)
2026-06-30 16:32:42 -05:00

372 lines
13 KiB
Python

"""Capabilities for the oven family (Samsung NV7000BS-class).
Resources verified against the live device via DTLS-CoAP.
See `local-tools/comparisons/oven-tree.md` for the full field reference.
Write surfaces this module exposes:
proven:
* Lamp via /mode/vs/0 options RMW (probe_oven_lamp_toggle.py)
— works even with Remote Control off.
unproven (first HA use is also the test):
* Sound, FastPreheat, NaturalSteam — same RMW pattern as lamp.
* Setpoint via /temperatures/vs/0 items RMW.
* Cook time via /operational/state/vs/0 operationTime/remainingTime.
* Mode select via /mode/vs/0 .modes — mid-cook acceptance unknown.
* Stop via /operational/state/vs/0 state='Ready'.
Note: Cycle start is not implemented. Reverse-engineering shows local-OCF
cycle start is not reproducible on this firmware (see project_oven_remote
_start_open.md). Mode writes are also unreliable — the oven rolls them back
once a cycle is active. OVEN_MODE is provided as a SelectDesc for fidelity
but is effectively read-only in practice.
"""
import time
from ..capability import Capability
from ..entities import (
BinarySensorDesc, ButtonDesc, NumberDesc, SelectDesc, SensorDesc,
SwitchDesc,
)
# ---------------------------------------------------------------------------
# Constants
# ---------------------------------------------------------------------------
SETPOINT_MIN_C = 30
SETPOINT_MAX_C = 270
SETPOINT_STEP_C = 5
# Mode options seen on NV7000BS-class. No dump exists so this list is inferred
# from Samsung documentation and firmware observations. The firmware will
# reject unknown modes; missing entries here are a coverage gap, not a bug.
_OVEN_MODES = (
'NoOperation',
'Bake',
'Broil',
'Convection',
'ConvectionBake',
'ConvectionBroil',
'FrozenPizzaPlus',
'SlowCook',
'PlateWarm',
'AirFry',
)
_SAMSUNG_STATE_TO_OCF = {
'Ready': 'idle',
'Run': 'active',
'Running': 'active',
'Pause': 'pause',
'Paused': 'pause',
'End': 'idle',
'Stop': 'idle',
}
def _to_ocf(v):
return _SAMSUNG_STATE_TO_OCF.get(v, v) if v is not None else None
def _int(v):
try:
return int(v)
except (TypeError, ValueError):
return None
def _rem_minutes(remaining):
if not remaining:
return None
try:
h, m, s = remaining.split(':')
return int(h) * 60 + int(m) + (1 if int(s) > 0 else 0)
except Exception:
return None
def _op_minutes(op_time):
"""Parse 'H:MM:SS' operationTime into integer minutes."""
if not op_time:
return None
try:
h, m, s = op_time.split(':')
return int(h) * 60 + int(m) + (1 if int(s) > 0 else 0)
except Exception:
return None
# ---------------------------------------------------------------------------
# Options-array helpers (shared by lamp, sound, fastpreheat, naturalsteam)
# ---------------------------------------------------------------------------
def _option_value(options, prefix):
"""Find `<prefix>_<value>` in an options array and return <value>."""
for o in (options or []):
if isinstance(o, str) and o.startswith(prefix + '_'):
return o.split('_', 1)[1]
return None
def _replace_in_options(options, prefix, new_value):
"""Return a new options list with the `<prefix>_*` slot replaced."""
return [f"{prefix}_{new_value}" if o.startswith(prefix + '_') else o
for o in options]
# ---------------------------------------------------------------------------
# Write functions
# ---------------------------------------------------------------------------
def _oven_setpoint_write(p, rep):
"""RMW write to /temperatures/vs/0 items array."""
try:
temp = float(p)
except (TypeError, ValueError):
return None
temp_i = int(round(temp / SETPOINT_STEP_C) * SETPOINT_STEP_C)
if not (SETPOINT_MIN_C <= temp_i <= SETPOINT_MAX_C):
return None
items = rep.get('x.com.samsung.da.items')
if not items:
return None
items = [dict(it) for it in items]
items[0]['x.com.samsung.da.desired'] = str(temp_i)
return ['temperatures', 'vs', '0'], {'x.com.samsung.da.items': items}
def _cook_time_write(p, rep):
"""Write operationTime + remainingTime (H:MM:SS) from minutes."""
try:
minutes = int(round(float(p)))
except (TypeError, ValueError):
return None
if not (0 <= minutes <= 1439):
return None
h, m = divmod(minutes, 60)
hms = f"{h:02d}:{m:02d}:00"
return ['operational', 'state', 'vs', '0'], {
'x.com.samsung.da.operationTime': hms,
'x.com.samsung.da.remainingTime': hms,
}
def _stop_write(p, rep):
return ['operational', 'state', 'vs', '0'], {
'x.com.samsung.da.state': 'Ready',
}
def _oven_mode_write(p, rep):
if p not in _OVEN_MODES:
return None
return ['mode', 'vs', '0'], {'x.com.samsung.da.modes': [p]}
def _lamp_write(p, rep):
if p not in ('On', 'Off'):
return None
opts = list(rep.get('x.com.samsung.da.options') or [])
if not opts:
return None
return ['mode', 'vs', '0'], {
'x.com.samsung.da.options': _replace_in_options(opts, 'UpperLamp', p),
}
def _sound_write(p, rep):
if p not in ('On', 'Off'):
return None
opts = list(rep.get('x.com.samsung.da.options') or [])
if not opts:
return None
return ['mode', 'vs', '0'], {
'x.com.samsung.da.options': _replace_in_options(opts, 'Sound', p),
}
def _fastpreheat_write(p, rep):
if p not in ('On', 'Off'):
return None
opts = list(rep.get('x.com.samsung.da.options') or [])
if not opts:
return None
return ['mode', 'vs', '0'], {
'x.com.samsung.da.options': _replace_in_options(opts, 'fastpreheat', p),
}
def _naturalsteam_write(p, rep):
if p not in ('On', 'Off'):
return None
opts = list(rep.get('x.com.samsung.da.options') or [])
if not opts:
return None
if not any(o.startswith('NaturalSteam_') for o in opts):
opts = opts + [f'NaturalSteam_{p}']
else:
opts = _replace_in_options(opts, 'NaturalSteam', p)
return ['mode', 'vs', '0'], {'x.com.samsung.da.options': opts}
# ---------------------------------------------------------------------------
# on_observation / project for remaining-time extrapolation
# ---------------------------------------------------------------------------
def _active_when(rep):
return _SAMSUNG_STATE_TO_OCF.get(rep.get('x.com.samsung.da.state')) == 'active'
def _on_observation(state, rep):
rem = rep.get('x.com.samsung.da.remainingTime')
if not isinstance(rem, str):
return
try:
h, m, s = rem.split(':')
state['remaining_anchor'] = (time.time(),
int(h) * 3600 + int(m) * 60 + int(s))
except (ValueError, AttributeError):
pass
def _project(state, sensors):
anchor = state.get('remaining_anchor')
if sensors.get('machine_state') != 'active' or anchor is None:
return sensors
ts, total = anchor
remaining = max(0, int(total - (time.time() - ts)))
h, rest = divmod(remaining, 3600)
m, s = divmod(rest, 60)
sensors = dict(sensors)
sensors['completion_time'] = f"{h}:{m:02d}:{s:02d}"
sensors['completion_minutes'] = h * 60 + m + (1 if s > 0 else 0)
return sensors
# ---------------------------------------------------------------------------
# Capabilities
# ---------------------------------------------------------------------------
OVEN_OPERATIONAL_STATE = Capability(
href='/operational/state/vs/0',
poll_tier='hot',
active_when=_active_when,
on_observation=_on_observation,
project=_project,
entities=(
SensorDesc(key='machine_state', field='x.com.samsung.da.state',
name='Machine state', icon='mdi:stove', value_fn=_to_ocf),
BinarySensorDesc(key='cycle_active', field='x.com.samsung.da.state',
name='Cycle active', device_class='running',
value_fn=lambda v: _SAMSUNG_STATE_TO_OCF.get(v) == 'active'),
SensorDesc(key='progress_percentage',
field='x.com.samsung.da.progressPercentage',
name='Progress percent', unit='%', state_class='measurement',
value_fn=_int),
SensorDesc(key='operation_time', field='x.com.samsung.da.operationTime',
name='Elapsed time', icon='mdi:timer'),
SensorDesc(key='operation_time_minutes',
field='x.com.samsung.da.operationTime',
name='Operation time (minutes)', unit='min',
state_class='measurement', value_fn=_op_minutes),
SensorDesc(key='completion_time', field='x.com.samsung.da.remainingTime',
name='Completion time', icon='mdi:timer-sand'),
SensorDesc(key='completion_minutes', field='x.com.samsung.da.remainingTime',
name='Remaining minutes', unit='min', device_class='duration',
state_class='measurement', value_fn=_rem_minutes),
NumberDesc(key='cook_time', field='x.com.samsung.da.operationTime',
name='Cook time', unit='min', native_min=0, native_max=1439,
step=1.0, icon='mdi:timer', value_fn=_op_minutes,
write_fn=_cook_time_write),
ButtonDesc(key='stop', field='', name='Stop cycle', icon='mdi:stop',
payload='Stop', write_fn=_stop_write),
),
)
OVEN_CAVITY = Capability(
href='/oven/vs/0',
poll_tier='hot',
entities=(
SensorDesc(key='oven_state', field='x.com.samsung.da.state',
name='Cavity state'),
),
)
OVEN_SETPOINT = Capability(
href='/temperatures/vs/0',
poll_tier='hot',
entities=(
# NumberDesc first — test_oven_setpoint_write_is_read_modify_write uses entities[0]
NumberDesc(key='oven_setpoint', field='x.com.samsung.da.items',
name='Setpoint', device_class='temperature', unit='°C',
native_min=float(SETPOINT_MIN_C), native_max=float(SETPOINT_MAX_C),
step=float(SETPOINT_STEP_C), icon='mdi:thermometer-chevron-up',
value_fn=lambda items: _int(
(items[0].get('x.com.samsung.da.desired') if items else None)),
write_fn=_oven_setpoint_write),
SensorDesc(key='current_temp_c', field='x.com.samsung.da.items',
name='Temperature', device_class='temperature',
state_class='measurement', unit='°C',
value_fn=lambda items: _int(
(items[0].get('x.com.samsung.da.current') if items else None))),
),
)
OVEN_DOOR = Capability(
href='/doors/vs/0',
poll_tier='hot',
entities=(
SensorDesc(key='door', field='x.com.samsung.da.items',
name='Door state',
value_fn=lambda items: (
items[0].get('x.com.samsung.da.openState')
if items else None)),
BinarySensorDesc(key='door_open', field='x.com.samsung.da.items',
name='Door', device_class='door',
value_fn=lambda items: (
items[0].get('x.com.samsung.da.openState') == 'Open'
if items else None)),
),
)
OVEN_CONNECTED = Capability(
href='/connected/vs/0',
poll_tier='warm',
entities=(
BinarySensorDesc(key='cloud_connected', field='x.com.samsung.da.connected',
name='Cloud connected', device_class='connectivity',
entity_category='diagnostic',
value_fn=lambda v: v == 'On'),
),
)
OVEN_MODE = Capability(
href='/mode/vs/0',
poll_tier='warm',
entities=(
# SelectDesc first — test_oven_mode_options_nonempty uses entities[0]
SelectDesc(key='oven_mode', field='x.com.samsung.da.modes',
name='Cooking mode', icon='mdi:tune',
options=_OVEN_MODES,
value_fn=lambda v: v[0] if v else None,
write_fn=_oven_mode_write),
SwitchDesc(key='lamp', field='x.com.samsung.da.options',
name='Lamp', icon='mdi:track-light',
value_fn=lambda opts: _option_value(opts, 'UpperLamp') == 'On',
write_fn=_lamp_write),
SwitchDesc(key='sound', field='x.com.samsung.da.options',
name='Sound', icon='mdi:volume-high',
value_fn=lambda opts: _option_value(opts, 'Sound') == 'On',
write_fn=_sound_write),
SwitchDesc(key='fast_preheat', field='x.com.samsung.da.options',
name='Fast preheat', icon='mdi:fire',
value_fn=lambda opts: _option_value(opts, 'fastpreheat') == 'On',
write_fn=_fastpreheat_write),
SwitchDesc(key='natural_steam', field='x.com.samsung.da.options',
name='Natural steam', icon='mdi:kettle-steam',
value_fn=lambda opts: _option_value(opts, 'NaturalSteam') == 'On',