Apply issue #56 field reports: filter direction, drop Blooming_*
Incorporates confirmed answers from the issue thread: - FilterProgress counts down as the filter wears (100 = fresh), so the sensor is renamed filter_progress -> filter_life to match the direction instead of implying "usage" like the AC/range_hood filterUsage sensors. - Blooming_* has no corresponding SmartThings app setting, so it's dropped entirely rather than kept as an unexplained diagnostic. - OptionCode_60282 and the missing humidity sensor are confirmed correct as already modeled (not user-facing / genuinely absent on this model). Five running-state diagnostics dumps (Auto/Sleep/Low/Medium/High) rule out the original guess that Comode_* is the fan-speed selector -- it reads 'Off' on every one of them. /airflow's speed field doesn't map monotonically to the five settings either (0 for both Auto and High, 3 for Low/Medium/ Sleep), and all five dumps were captured within about three minutes of each other -- one poll cycle at this integration's 30s summary interval -- so fan-speed modeling stays unbuilt pending a cleaner capture.
This commit is contained in:
3 files changed
+71
-57
No files matched your search
+1
-2
@@ -1,7 +1,6 @@
|
||||
{
|
||||
"state_keys": [
|
||||
"alarm_code",
|
||||
"blooming_level",
|
||||
"clean_level",
|
||||
"device_active",
|
||||
"diagnosis_status",
|
||||
@@ -13,7 +12,7 @@
|
||||
"energy_this_month_kwh",
|
||||
"fan_direction",
|
||||
"fan_speed_level",
|
||||
"filter_progress",
|
||||
"filter_life",
|
||||
"fine_dust",
|
||||
"odor",
|
||||
"operating_mode",
|
||||
|
||||
Reference in new issue
Block a user