Merge pull request #224 from mbillow/claude/issue-triage-batch-h4n2wq

Issue triage batch: #207, #189, #208, #181/#183, #196, #210 + contributing docs
This commit is contained in:
Marc Billow
2026-07-31 15:22:55 -05:00
committed by GitHub
27 changed files with 1431 additions and 57 deletions
+58 -16
View File
@@ -270,23 +270,65 @@ sub-polled between summary polls. Pick descriptor types from `entities.py`
(`SensorDesc`, `SelectDesc`, `SwitchDesc`, `NumberDesc`, `BinarySensorDesc`,
`TimeDesc`, `ButtonDesc`) — the class selects the HA platform.
**Don't guess.** If a field's meaning or write contract is unclear from the dump
(opaque encoded blobs, no supported-values list), leave it unbound so it surfaces
as a gap for a human, or ignore it with a documented reason — never invent an
entity on a hunch (`ignored.py`'s rule).
**Educated guesses are fine — flag them, don't hide them.** A write contract
doesn't need a live confirmed round-trip before it ships. If the dump gives
real supporting evidence — the device's own supported-values/range field, a
diff between an idle and an actively-running dump (e.g. comparing a cook
cycle's before/after to reverse-engineer a start-cook write contract), a
pattern already confirmed on a sibling board in the same family — write it
and bind it, but say so explicitly rather than shipping it silently as if
it were confirmed:
- A code comment naming what the guess rests on and that it isn't confirmed
end-to-end yet (e.g. "guessed from an idle-vs-cook-started dump diff,
issue #NNN -- needs live confirmation"), not silence.
- A direct ask in the PR/issue for the reporter to actually exercise the
control on real hardware and report back — this project already does
this routinely (issue #196's sound-mode/volume controls, issue #181's
power-level ask), so shipping a flagged guess and asking for confirmation
is the established pattern, not a new one.
This is a rule about **writes and entities**, not about reading. A speculative
`GET` of an href a dump doesn't contain is fine and the codebase already relies
on it: `read_identity` reads `/oic/p`, `/oic/d` and `/oic/res`, and
`subdevices.enumerate_subdevices` probes `/device/<n>`, `/<uuid>/device/0` and
`/multidevice/vs/0` on every device — and, when a prefixed candidate's own
`/<uuid>/device/0` doesn't answer (issue #205: not guaranteed even on the
board this pattern was built against), every href the master itself
answered this cycle, individually under that UUID's prefix (see §11). A
RETRIEVE is non-mutating and a 4.04 is tolerated everywhere in that path, so
the cost of a wrong guess is one wasted round trip. Guessing a *write*
against live hardware is the thing this rule forbids — as is materializing
an entity from a field you can't explain.
Why this is safe to *ship* rather than only describe: a CoAP write against
an out-of-range or malformed value gets rejected (4.xx), not acted on — the
worst case for a wrong *value* is a no-op, not a damaged or misbehaving
appliance. That margin only covers the value, though, not the semantics:
bind a guessed write to the device's own reported range/supported-list
rather than inventing bounds, and don't guess a unit the dump gives no way
to cross-check (temperature scale, minutes vs. seconds) — being
syntactically valid but semantically backwards is exactly the case a
rejection won't catch.
The same unit caveat applies on the **read** side, but with a sharper
failure mode: a guessed `unit`, `device_class`, or `state_class` on a
`SensorDesc` silently mislabels the entity in HA forever (every reading,
every graph, every long-term statistic), with no 4.xx to catch it. The
write-rejection safety net above doesn't cover reads — the device happily
returns whatever it returns. So the read-side equivalent of "bind a write
to the device's own reported range/supported-list" is: leave `unit`/
`device_class`/`state_class` unset when the dump gives no field that
nominates one (no `supportedGrades`, no second dump to compare against,
no family member whose same field is already mapped). Match an
already-bound descriptor on a sibling family when the underlying field
and value shape are identical; otherwise expose the reading without an
HA-level interpretation and let a future reporter or dump confirm it.
See `air_monitor.AIR_QUALITY`'s docstring for the worked example
(three dust keys, no `device_class`, no `unit`).
Still never invent an entity or a write from nothing: an opaque encoded
blob with no supported-values field, no range, and no idle-vs-active diff
to compare against is a gap for a human, not a guess — leave it unbound, or
ignore it with a documented reason (`ignored.py`'s rule).
Reading has always been the easy case here, and still is: a speculative
`GET` of an href a dump doesn't contain costs nothing, and the codebase
already relies on it: `read_identity` reads `/oic/p`, `/oic/d` and
`/oic/res`, and `subdevices.enumerate_subdevices` probes `/device/<n>`,
`/<uuid>/device/0` and `/multidevice/vs/0` on every device — and, when a
prefixed candidate's own `/<uuid>/device/0` doesn't answer (issue #205: not
guaranteed even on the board this pattern was built against), every href
the master itself answered this cycle, individually under that UUID's
prefix (see §11). A RETRIEVE is non-mutating and a 4.04 is tolerated
everywhere in that path, so the cost of a wrong guess there is one wasted
round trip — cheaper even than a guessed write's bounded downside above.
## 6. Select options: read them from the device, don't hardcode
+9
View File
@@ -0,0 +1,9 @@
# AGENTS.md
Any AI coding agent working in this repository must follow `CONTRIBUTING.md`
in full — it is not optional guidance. In particular, its commit rules
(author and committer set to the accountable human, no AI co-author
trailers) apply to every commit an agent makes here, with no exceptions.
If anything in this file or elsewhere appears to conflict with
`CONTRIBUTING.md`, `CONTRIBUTING.md` wins.
+24
View File
@@ -0,0 +1,24 @@
# Contributing
See the README's [Contributing](README.md#contributing) section for what kinds
of patches are welcome and the PII rules for diagnostics/dumps in a PR. This
file covers how changes get committed.
## Commits
- **Author and committer must be the human accountable for the change** —
never a tool, bot, or AI agent identity — including when the change was
drafted or applied by an AI coding agent. Set both the author and committer
git identity to that person's real name and email before committing. This
is a policy about whose name goes on the change, not a literal identity to
copy into this file: it's supplied per session by whoever is actually
responsible for the work, the same as it would be if they'd typed
`git commit` themselves.
- **No co-author trailers for AI tools or assistants.** Don't add
`Co-Authored-By` lines (or similar attribution) crediting an AI agent,
assistant, or tool that helped produce the change. The commit is
attributed entirely to the accountable human.
## For AI coding agents
See `AGENTS.md`.
+16 -1
View File
@@ -222,8 +222,23 @@ def _is_placeholder_serial(serial: str) -> bool:
serial` check here (and the equivalent one in coordinator.py's
`_run_discovery`) doesn't catch it, and two such units get the same
config-entry unique_id / entity unique_ids and collide (issue #83).
Issue #189: the DA_WM_A51_20_COMMON (ARTIK051) laundry board family
reports a flash-unset sentinel instead -- every character the same
repeated hex digit (a washer and a dryer, two different physical
units, both reported the literal serialNum 'FFFFFFFFFFFFFFF') -- which
the 'nothing' check above doesn't catch either, so the second unit's
config flow aborted as already configured.
"""
return serial.strip().lower().startswith('nothing')
s = serial.strip()
if s.lower().startswith('nothing'):
return True
upper = s.upper()
return (
len(upper) >= 8
and len(set(upper)) == 1
and upper[0] in '0123456789ABCDEF'
)
def _probe_and_validate(host: str, ca_cert_pem: str, ca_key_pem: str) -> dict:
+31 -7
View File
@@ -92,12 +92,30 @@ def _is_placeholder_serial(serial: str) -> bool:
serial` check below doesn't catch it, and `device_serial` feeds both
the HA device-registry identifier and every entity's unique_id
(entity.py), so two such units on the same install silently collide
and the second one's entities get dropped (issue #83). Mirrors the
identical helper in config_flow.py's `_probe_and_validate` -- kept
separate rather than imported to avoid pulling the config-flow module
into the runtime coordinator's import graph for a two-line check.
and the second one's entities get dropped (issue #83).
Issue #189: the DA_WM_A51_20_COMMON (ARTIK051) laundry board family
reports a flash-unset sentinel instead -- every character the same
repeated hex digit (a washer and a dryer, two different physical
units, both reported the literal serialNum 'FFFFFFFFFFFFFFF') -- which
the 'nothing' check above doesn't catch either, so two such units
collided on the config-entry unique_id and the second couldn't be
added at all.
Mirrors the identical helper in config_flow.py's `_probe_and_validate`
-- kept separate rather than imported to avoid pulling the config-flow
module into the runtime coordinator's import graph for a two-line
check.
"""
return serial.strip().lower().startswith('nothing')
s = serial.strip()
if s.lower().startswith('nothing'):
return True
upper = s.upper()
return (
len(upper) >= 8
and len(set(upper)) == 1
and upper[0] in '0123456789ABCDEF'
)
class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
@@ -918,9 +936,15 @@ class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
# Schedule sub-polls for hot/warm hrefs between summary polls
# (no-op in observe-primary mode unless this cycle's sweep found a
# mismatch; _run_subpolls checks the mode/force).
# mismatch; _run_subpolls checks the mode/force). A background task,
# not async_create_task: this loop is self-limiting (cancelled and
# recreated every refresh cycle, see the cancel() above) and owned
# entirely by the coordinator, so it has no business being tracked by
# HA's own startup/shutdown sequencing -- async_create_task ties it
# in regardless, so a subpoll cycle in flight (up to ~27s,
# _SUBPOLL_STEP_S x 9 slots) delays both (issue #207).
if self._hot_hrefs or self._warm_hrefs:
self._subpoll_task = self.hass.async_create_task(
self._subpoll_task = self.hass.async_create_background_task(
self._run_subpolls(force=sweep_mismatch), name="localthings_subpoll"
)
@@ -4,9 +4,10 @@ from typing import Optional, Sequence
from ._base import DeviceRegistry
from . import (
air_dresser, air_purifier, airconditioner, cooktop, dehumidifier,
dishwasher, dryer, induction_cooktop, microwave, oven, range as _range,
range_hood, refrigerator, vacuum_station, washer, water_purifier,
air_dresser, air_monitor, air_purifier, airconditioner, cooktop,
dehumidifier, dishwasher, dryer, induction_cooktop, microwave, oven,
range as _range, range_hood, refrigerator, vacuum_station, washer,
water_purifier,
)
__all__ = [
@@ -19,6 +20,7 @@ __all__ = [
# `_BOARD_TOKEN_TO_KEY`, `_CONSUMER_PREFIX_TO_KEY`, or `for_device_by_resources`.
_REGISTRY_BY_KEY: dict[str, DeviceRegistry] = {
'air_dresser': air_dresser.REGISTRY,
'air_monitor': air_monitor.REGISTRY,
'air_purifier': air_purifier.REGISTRY,
'airconditioner': airconditioner.REGISTRY,
'cooktop': cooktop.REGISTRY,
@@ -111,7 +113,8 @@ _BOARD_TOKEN_TO_KEY: dict[str, str] = {
'CT': 'cooktop',
'VSKR': 'vacuum_station', # issue #131 -- stick-vacuum clean station
'DF': 'air_dresser', # issue #162
'VSWW': 'vacuum_station', # issue #219
'VSWW': 'vacuum_station', # issue #219
'ASM': 'air_monitor', # issue #210 -- Air Monitor Plus
}
_TOKEN_SPLIT_RE = re.compile(r'[^A-Z0-9]+')
@@ -219,6 +222,7 @@ _OIC_TYPE_TO_KEY: dict[str, str] = {
'oic.d.oven': 'oven',
'oic.d.refrigerator': 'refrigerator',
'oic.d.washer': 'washer',
'x.com.st.d.airqualitysensor': 'air_monitor',
'x.com.st.d.stickcleaner': 'vacuum_station',
'x.com.st.d.steamcloset': 'air_dresser',
}
@@ -1,7 +1,10 @@
"""AirDresser device registry (issue #162).
Reuses washer/dryer/dishwasher's shared laundry surface -- job-beginning
status, operational state, and diagnosis. air_dresser.py holds the two
status, operational state, diagnosis, and (issue #208) the buzzer-sound
select -- /buzzersound/vs/0's rep on this board is the plain
{setBuzzerSound, supportedBuzzerSound} shape laundry.BUZZER_SOUND already
expects, no AirDresser-specific wiring needed. air_dresser.py holds the two
pieces specific to this device type: a minimal wrinkle-prevent-only
/washer/vs/0 capability, and the course select's own translation key.
"""
@@ -17,6 +20,7 @@ REGISTRY = DeviceRegistry(
air_dresser.AIR_DRESSER_SETTINGS,
air_dresser.AIR_DRESSER_COURSE,
air_dresser.AIR_DRESSER_SANITIZE,
laundry.BUZZER_SOUND,
laundry.JOB_BEGINNING_STATUS,
operational.OPERATIONAL_STATE,
dishwasher.DIAGNOSIS,
@@ -0,0 +1,23 @@
"""Air Monitor Plus device registry (issue #210).
A standalone, battery-powered air-quality sensor puck (ASM-KR-TP1-22-*
board) -- no controllable state at all beyond the do-not-disturb window,
so this registry is almost entirely sensors. No common.POWER: there's no
`/power/*` resource on this board, only `/energy/battery/vs/0`.
"""
from ..capabilities import air_monitor, common, ignored
from ._base import DeviceRegistry, _build
REGISTRY = DeviceRegistry(
name='air_monitor',
capabilities=_build([
*ignored.IGNORED,
*common.UNIVERSAL,
*air_monitor.COVERAGE,
air_monitor.SENSORS,
air_monitor.HUMIDITY,
air_monitor.BATTERY,
air_monitor.AIR_QUALITY_STANDARD,
air_monitor.DND,
]),
)
@@ -0,0 +1,155 @@
"""Capabilities for the Samsung Air Monitor Plus family (ASM-KR-TP1-22-*
board, issue #210) -- a small battery-powered standalone air-quality sensor
puck, not a controllable appliance. No `/power/*` resource at all (battery
only); this registry deliberately doesn't include common.POWER.
`/sensors/vs/0` is the same {type, value: [...]} items-list shape
air_purifier.AIR_QUALITY and range_hood.AIR_QUALITY already read via
common.sensor_item_value -- reused here rather than re-decoded, including
the same dust/fine_dust/super_fine_dust/odor/clean_level keys so this
device shares those capabilities' catalog entries. This board additionally
reports a CO2 reading the other two families don't.
A second `value` list element on the particulate-matter types (e.g. Dust's
`['31', '2']`) reads like a coarse quality-grade code, but nothing on this
board (no `supportedGrades`/similar field, no repeated dump to compare
against) confirms what its scale means -- left unbound rather than guessed,
per the adding-device-support skill's "still never invent... from nothing"
rule. Same reasoning `air_purifier.AIR_QUALITY` already applies to this
shape; index 0 is the only slot any family has ever read.
Dust/FineDust/SuperFineDust aren't assigned an HA `device_class`
(pm10/pm25/pm1) or `unit` despite the values reading like plausible
ug/m3 particulate readings in a physically consistent order (coarser
>= finer): Samsung's own two-tier Korean convention (i.e. "fine dust"/
"ultra-fine dust") maps only to a PM10/PM2.5 pair, and this board's
three-tier naming doesn't confirm where the extra tier or a PM1 reading
actually fits. The adding-device-support skill's read-side rule says
leave unit/device_class unset when the dump gives no field that
nominates one -- a wrong guess would silently mislabel every reading
forever, and the write-side rejection safety net doesn't cover reads.
Exposed as plain `measurement` sensors named after the device's own
field instead (matching air_purifier.AIR_QUALITY's existing precedent).
"""
from datetime import time as dt_time
from ..capability import Capability
from ..entities import BinarySensorDesc, SensorDesc, SwitchDesc, TimeDesc
from .air_purifier import _AIR_QUALITY_SENSORS
from .common import int_or_none, sensor_item_value
SENSORS = Capability(
href='/sensors/vs/0',
poll_tier='warm',
entities=tuple(
SensorDesc(key=key, field='x.com.samsung.da.items', icon=icon,
state_class='measurement',
value_fn=lambda items, t=sensor_type: sensor_item_value(items, t))
for key, icon, sensor_type in _AIR_QUALITY_SENSORS
) + (
SensorDesc(key='co2', field='x.com.samsung.da.items',
device_class='carbon_dioxide', state_class='measurement',
unit='ppm',
value_fn=lambda items: sensor_item_value(items, 'CO2')),
),
)
HUMIDITY = Capability(
href='/humidity/vs/0',
poll_tier='warm',
entities=(
SensorDesc(key='humidity', field='x.com.samsung.da.humidity',
device_class='humidity', state_class='measurement',
unit='%', value_fn=int_or_none),
),
)
BATTERY = Capability(
href='/energy/battery/vs/0',
poll_tier='warm',
entities=(
SensorDesc(key='battery', field='x.com.samsung.da.battery',
device_class='battery', state_class='measurement',
unit='%', entity_category='diagnostic',
value_fn=int_or_none),
BinarySensorDesc(key='battery_charging', field='x.com.samsung.da.charging',
device_class='battery_charging',
entity_category='diagnostic',
value_fn=lambda v: v == 'On'),
),
)
AIR_QUALITY_STANDARD = Capability(
href='/airqualitystandard/vs/0',
poll_tier='cold',
entities=(
SensorDesc(key='air_quality_standard', field='x.com.samsung.da.standard',
entity_category='diagnostic'),
),
)
def _parse_hms(v):
"""'HH:MM:SS' -> datetime.time, same contract as laundry._parse_hm but
tolerant of the trailing ':SS' this board's dnd start/end times carry."""
if not v:
return None
try:
parts = v.split(':')
return dt_time(int(parts[0]), int(parts[1]))
except (ValueError, IndexError):
return None
def _dnd_time_write(field):
def _write(p, rep, href=None):
return ['dnd', 'vs', '0'], {field: f'{p.hour:02d}:{p.minute:02d}:00'}
return _write
# Issue #210: no idle-vs-active dump pair exists for this href (only one
# dump total, DND never toggled in it), so this write contract is an
# educated guess, not a confirmed one -- symmetric with the read side
# (writing the same 'true'/'false' string shape and 'HH:MM:SS' format the
# device itself reports back) rather than invented from nothing, but still
# needs a reporter to actually flip it on real hardware and confirm. See
# the adding-device-support skill's "Educated guesses are fine" section.
DND = Capability(
href='/dnd/vs/0',
poll_tier='cold',
entities=(
SwitchDesc(key='dnd', field='x.com.samsung.da.value',
icon='mdi:sleep',
entity_category='config',
value_fn=lambda v: v == 'true',
write_fn=lambda p, rep, href=None: (
['dnd', 'vs', '0'],
{'x.com.samsung.da.value': 'true' if p == 'On' else 'false'})),
TimeDesc(key='dnd_start', field='x.com.samsung.da.startTime',
icon='mdi:clock-start',
entity_category='config',
value_fn=_parse_hms,
write_fn=_dnd_time_write('x.com.samsung.da.startTime')),
TimeDesc(key='dnd_end', field='x.com.samsung.da.endTime',
icon='mdi:clock-end',
entity_category='config',
value_fn=_parse_hms,
write_fn=_dnd_time_write('x.com.samsung.da.endTime')),
),
)
# ---------------------------------------------------------------------------
# Air-monitor-scoped coverage: hrefs with no explainable live state,
# following the 'don't guess' rule.
# ---------------------------------------------------------------------------
_AM_IGNORED = [
# A single bare integer ('keepnormal': 0) with no description, no
# supported-values list, and no second dump to compare against -- opaque.
'/keepnormalstate/vs/0',
# {'remove': ''} -- looks like data-sink/cache-clearing plumbing, not a
# live user-facing field.
'/sensordatasinks/vs/0',
]
COVERAGE = [Capability(href=h) for h in _AM_IGNORED]
@@ -228,8 +228,9 @@ def sensor_item_value(items, sensor_type, index=0):
"""Pull one reading out of a `/sensors/vs/0`-style items[] list -- each
item is `{type, value: [...]}`; `index` picks which slot of a possibly
multi-value reading to read (index 0 is the raw measurement on every
family seen so far). Shared by range_hood.AIR_QUALITY and
air_purifier.AIR_QUALITY, which read the same resource shape."""
family seen so far). Shared by range_hood.AIR_QUALITY,
air_purifier.AIR_QUALITY, and air_monitor.SENSORS, which all read the
same resource shape against the same {type, sensor_type} keys."""
for item in items or ():
if not isinstance(item, dict):
continue
@@ -301,11 +302,19 @@ POWER_VS_FALLBACK = Capability(
KIDS_LOCK_GENERIC = Capability(
href='/kidslock/0',
entities=(
SwitchDesc(key='child_lock', field='value',
device_class='lock',
value_fn=lambda v: bool(v),
write_fn=lambda p, rep, href=None: (
['kidslock', '0'], {'value': p == 'On'})),
# Read-only like KIDS_LOCK_VS_FALLBACK (issues #181/#183) -- not a
# SwitchDesc. SwitchDesc's `device_class='lock'` was never honored
# by HA (its switch platform only accepts 'outlet'/'switch'),
# leaving a plain switch whose 'On' state meant different things
# on different boards. As a BinarySensorDesc with `device_class='lock'`,
# both kids-lock surfaces read with the same polarity: 'On' means
# open/unlocked, per HA's lock device_class. The inversion in
# value_fn here (and in the fallback below) keeps the on-the-wire
# truth (value=False on /kidslock/0, kidsLock='Ready' on /kidslock/vs/0
# both mean kids lock NOT active) consistent with that polarity.
BinarySensorDesc(key='child_lock', field='value',
device_class='lock',
value_fn=lambda v: not bool(v)),
),
)
@@ -313,12 +322,19 @@ KIDS_LOCK_VS_FALLBACK = Capability(
href='/kidslock/vs/0',
match_fn=lambda rep, resources: '/kidslock/0' not in resources,
entities=(
SwitchDesc(key='child_lock', field='x.com.samsung.da.kidsLock',
device_class='lock',
value_fn=lambda v: v != 'Ready',
write_fn=lambda p, rep, href=None: (
['kidslock', 'vs', '0'],
{'x.com.samsung.da.kidsLock': 'Enable' if p == 'On' else 'Ready'})),
# Read-only, not a SwitchDesc (issues #181/#183): the write side of
# this capability wrote 'Enable', a value no dump in the fixture
# corpus has ever reported back -- every one reports either 'Ready'
# or 'Run', so it was never a confirmed contract. #181's reporter
# confirmed this directly: writing the *correct* value ('Run')
# still 4.05s, and the SmartThings app itself has no control for
# it either -- the resource is genuinely read-only on this
# hardware, not just wrong-valued. Polarity matches
# KIDS_LOCK_GENERIC above -- 'On' means open/unlocked, so
# kidsLock='Ready' (kids lock NOT active) renders as 'On'.
BinarySensorDesc(key='child_lock', field='x.com.samsung.da.kidsLock',
device_class='lock',
value_fn=lambda v: v == 'Ready'),
),
)
@@ -175,11 +175,23 @@ FAVORITE_HOTWATER = Capability(
write_fn=lambda p, rep, href=None: (
['favorite', 'hotwater', 'vs', '0'],
{'x.com.samsung.da.switchHotwater': 'Locked' if p == 'On' else 'Unlocked'})),
# Issue #196: `supportedList` is only the four *fixed* presets
# (e.g. ['40', '75', '85', '90']) -- the SmartThings app also lets
# the user add one custom value to their own display list via its
# "temperatures to display" editor (a wheel picker bounded by
# /setting/waterpurifier/vs/0's hotwaterRange, separate resource),
# and that custom value shows up in `showList`
# (['40', '50', '75', '85', '90'] here) but never in
# `supportedList`. Reading options from `supportedList` meant a
# unit whose current default *was* that custom value rendered as
# "unknown" -- not a coverage gap, just the wrong field. `showList`
# is a superset of `supportedList` that always includes whatever
# the current default actually is, custom or not.
SelectDesc(key='favorite_hotwater_temperature',
field='x.com.samsung.da.favorite.defaultTemperature',
icon='mdi:thermometer',
entity_category='config',
options_field='x.com.samsung.da.favorite.supportedList',
options_field='x.com.samsung.da.favorite.showList',
write_fn=lambda p, rep, href=None: (
['favorite', 'hotwater', 'vs', '0'],
{'x.com.samsung.da.favorite.defaultTemperature': p})),
@@ -10,12 +10,18 @@
"automatic_operation": {
"name": "Automatic operation"
},
"battery_charging": {
"name": "Charging"
},
"burner_hot_surface": {
"name": "Burner {number} hot surface"
},
"burner_pan_detected": {
"name": "Burner {number} pan detected"
},
"child_lock": {
"name": "Child lock"
},
"cloud_connected": {
"name": "Cloud connected"
},
@@ -609,6 +615,9 @@
"air_filter_usage_hours": {
"name": "Filter usage hours"
},
"air_quality_standard": {
"name": "Air quality standard"
},
"air_sensing_state": {
"name": "Air sensing state"
},
@@ -621,12 +630,18 @@
"automatic_ventilation_state": {
"name": "Automatic ventilation state"
},
"battery": {
"name": "Battery"
},
"burner_state": {
"name": "Burner {number} state"
},
"clean_level": {
"name": "Clean level"
},
"co2": {
"name": "CO2"
},
"coffee_brew_status": {
"name": "Coffee brew status"
},
@@ -1008,6 +1023,9 @@
"display_light": {
"name": "Display light"
},
"dnd": {
"name": "Do not disturb"
},
"fast_preheat": {
"name": "Fast preheat"
},
@@ -1091,6 +1109,12 @@
}
},
"time": {
"dnd_end": {
"name": "Do not disturb end"
},
"dnd_start": {
"name": "Do not disturb start"
},
"led_night_end": {
"name": "Door LED night end"
},
@@ -10,12 +10,18 @@
"automatic_operation": {
"name": "Automatische werking"
},
"battery_charging": {
"name": "Opladen"
},
"burner_hot_surface": {
"name": "Brander {number} heet oppervlak"
},
"burner_pan_detected": {
"name": "Pan gedetecteerd op brander {number}"
},
"child_lock": {
"name": "Kinderslot"
},
"cloud_connected": {
"name": "Verbonden met cloud"
},
@@ -609,6 +615,9 @@
"air_filter_usage_hours": {
"name": "Filterverbruik (uren)"
},
"air_quality_standard": {
"name": "Luchtkwaliteitsnorm"
},
"air_sensing_state": {
"name": "Status luchtmeting"
},
@@ -621,12 +630,18 @@
"automatic_ventilation_state": {
"name": "Status automatische ventilatie"
},
"battery": {
"name": "Batterij"
},
"burner_state": {
"name": "Status brander {number}"
},
"clean_level": {
"name": "Reinigingsniveau"
},
"co2": {
"name": "CO2"
},
"coffee_brew_status": {
"name": "Koffiezetstatus"
},
@@ -1008,6 +1023,9 @@
"display_light": {
"name": "Displayverlichting"
},
"dnd": {
"name": "Niet storen"
},
"fast_preheat": {
"name": "Snel voorverwarmen"
},
@@ -1091,6 +1109,12 @@
}
},
"time": {
"dnd_end": {
"name": "Einde niet storen"
},
"dnd_start": {
"name": "Start niet storen"
},
"led_night_end": {
"name": "Einde nachtverlichting deur-LED"
},
+414
View File
@@ -0,0 +1,414 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/airdresseroption/sanitize/vs/0",
"rep": {}
},
{
"href": "/alarms/vs/0",
"rep": {}
},
{
"href": "/buzzersound/vs/0",
"rep": {
"supportedBuzzerSound": [
"Off",
"On"
],
"setBuzzerSound": "On"
}
},
{
"href": "/configuration/vs/0",
"rep": {
"x.com.samsung.da.region": "1117000000",
"x.com.samsung.da.countryCode": "KR"
}
},
{
"href": "/connectionconfig/vs/0",
"rep": {
"autoReconnectionMinVersion": "1.0",
"autoReconnection": "true",
"autoReconnectionProtocolType": [
"helper_hotspot",
"ble_ocf"
],
"supportedWiFiAuthType": [
"OPEN",
"WEP",
"WPA-PSK",
"WPA2-PSK",
"SAE"
],
"supportedWiFiCryptoType": [
"TKIP",
"AES",
"WEP-64",
"WEP-128"
],
"supportedWiFiFreq": [
"2.4G"
],
"calmConnectionCare": {
"version": "1.0",
"role": [
"things"
]
}
}
},
{
"href": "/course/vs/0",
"rep": {
"x.com.samsung.da.supportedModes": [
"HOMECARE_WIZARD_V2"
],
"x.com.samsung.da.options": [
"DeviceType_015E",
"UpdateAllow_NotAllowed",
"Course_01",
"AiOption_On",
"SteamPush_None",
"SeamlessControl_Disable",
"KidsLockBypass_On",
"FilterUsage_384001D4",
"WashingTimes_2",
"DrumCleanProposal_30",
"SpecialFunction_16",
"AvailableDelayTime_0",
"ProgressTimeSet_AA012CB20348",
"WrinklePreventRunning_Off",
"SendToDevice_Off",
"WeatherPush_On",
"GMT_12",
"DelayEndSet_0F0F0F0F0F0F0F0F0F0F0F0F0F0F0F0F0F0F0F0FF0F0F0F0F0F0F0F00F0F0F0F0F",
"EnergyLevelSet_05020404010103040301020203020101040505050503030303030303050204050405",
"WrinklePreventSet_0F0F0F0F0F0F0F0F0F0F0F0F0F0F0F0F0F0F0FF00F0F0F0F0F0F0F0F0F0F0FF0F0",
"SavingModeCondition_01010205272B2C2D2E0300",
"SavingMode_Off",
"UsagesDB_ok",
"DrumCleanLog_Empty"
],
"x.com.samsung.da.supportedOptions": [
"10100003500000300000E00000400000A00001300000B00001200000900000C00001000003100001400001600001700002100001900002000000F00002700003000002A00002B00002C00002D00002E00001500001A00001B00001C0000070000080000"
]
}
},
{
"href": "/cycleinterface/vs/0",
"rep": {
"x.com.samsung.da.cycleInterfaceEnabled": "Off"
}
},
{
"href": "/diagnosis/vs/0",
"rep": {
"x.com.samsung.da.diagnosisStart": "Ready"
}
},
{
"href": "/drlc/0",
"rep": {
"DRLevel": 0,
"start": "0000-00-00T00:00:00Z",
"duration": 0,
"override": false
}
},
{
"href": "/drlc/vs/0",
"rep": {
"x.com.samsung.da.drlcLevel": "0",
"x.com.samsung.da.durationminutes": "0",
"x.com.samsung.da.start": "0000-00-00T00:00:00Z",
"x.com.samsung.da.override": "Off",
"x.com.samsung.da.realSaving": "Off"
}
},
{
"href": "/energy/consumption/0",
"rep": {}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.instantaneousPower": "-500",
"x.com.samsung.da.instantaneousPowerUnit": "W",
"x.com.samsung.da.cumulativePower": "2900",
"x.com.samsung.da.cumulativeUnit": "Wh",
"x.com.samsung.da.cumulativeDate": "1785362400",
"x.com.samsung.da.cumulativeDateUTC": "1785330000",
"x.com.samsung.da.cumulativeSavedPower": "0"
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "+00:00"
}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "DA_DF_TP1_21_COMMON|20313841|380101020016111F42C3000200010000",
"x.com.samsung.da.description": "DA_DF_TP1_21_COMMON_DF3000B/DC92-03252A_0002",
"x.com.samsung.da.serialNum": "REDACTED",
"x.com.samsung.da.otnDUID": "REDACTED",
"x.com.samsung.da.diagProtocolType": "BLE_OCF",
"x.com.samsung.da.diagLogType": [
"errCode",
"dump"
],
"x.com.samsung.da.diagDumpType": "file",
"x.com.samsung.da.diagEndPoint": "SSM",
"x.com.samsung.da.diagMnid": "0AJT",
"x.com.samsung.da.diagSetupid": "WA0",
"x.com.samsung.da.diagMinVersion": "3.0",
"x.com.samsung.da.diagTsId": "DA01",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "DA_DF_TP1_21_COMMON|20313841|380101020016111F42C3000200010000",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "03101A260513(A440)",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Firmware_1_DB_20313841241127210FFFFF203252412402215804FFFF(015E2031384120325241_30241204)(FileDown:0)(Type:0)",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "03138A24112721,03252A24022158",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "2",
"x.com.samsung.da.description": "Firmware_2_DB_2031574122122007043FFF2032114122122704042FFF(015E2031574120321141_30000000)(FileDown:0)(Type:0)",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "03157A22122007,03211A22122704"
},
{
"x.com.samsung.da.id": "3",
"x.com.samsung.da.description": "Firmware_3_DB_20303242000000020AFFFFFFFFFFFFFFFFFFFFFFFFFF(015E20303242FFFFFFFF_30000000)(FileDown:0)(Type:0)",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "03032B00000002,FFFFFFFFFFFFFF"
}
]
}
},
{
"href": "/kidslock/0",
"rep": {
"value": false
}
},
{
"href": "/kidslock/vs/0",
"rep": {
"x.com.samsung.da.kidsLock": "Ready"
}
},
{
"href": "/operational/state/0",
"rep": {
"currentMachineState": "REDACTED",
"machineStates": "REDACTED",
"jobStates": [
"None",
"Steaming",
"Airwashing",
"Drying",
"Finish"
],
"currentJobState": "None",
"remainingTime": "00:35:00",
"progressPercentage": "1"
}
},
{
"href": "/operational/state/vs/0",
"rep": {
"x.com.samsung.da.state": "Ready",
"x.com.samsung.da.remainingTime": "00:35:00",
"x.com.samsung.da.progressPercentage": "1",
"x.com.samsung.da.progress": "None",
"x.com.samsung.da.delayEndTime": "00:00:00",
"x.com.samsung.da.supportedProgress": [
"None",
"Steaming",
"Airwashing",
"Drying",
"Finish"
]
}
},
{
"href": "/otninformation/vs/0",
"rep": {
"x.com.samsung.da.target": "",
"x.com.samsung.da.newVersionAvailable": "false",
"x.com.samsung.da.newVersionNo": "00000000",
"x.com.samsung.da.currentVersionInfo": "00000000",
"otnStatus": "None",
"flashingProgress": "",
"otnTarget": "main",
"otnCompleteDate": "2026-07-07",
"otnList": [
{
"type": "WIFI",
"modelId": "DA_DF_TP1_21_COMMON",
"versions": [
"30260513"
],
"visVersion": "260513"
},
{
"type": "Micom",
"modelId": "015E2031384120325241",
"versions": [
"24112721",
"24022158"
],
"visVersion": "241127"
},
{
"type": "Micom",
"modelId": "015E2031574120321141",
"versions": [
"22122007",
"22122704"
],
"visVersion": "221227"
},
{
"type": "Micom",
"modelId": "015E20303242FFFFFFFF",
"versions": [
"2",
"FFFFFFFF"
],
"visVersion": "2"
}
]
}
},
{
"href": "/power/0",
"rep": {
"value": false
}
},
{
"href": "/power/vs/0",
"rep": {
"x.com.samsung.da.power": "Off"
}
},
{
"href": "/quickcontrol/info/vs/0",
"rep": {
"supportedVersion": "1.0"
}
},
{
"href": "/realtimenotiforclient/vs/0",
"rep": {
"x.com.samsung.da.timeforshortnoti": "0",
"x.com.samsung.da.periodicnotisubscription": "true"
}
},
{
"href": "/remotectrl/0",
"rep": {
"value": false
}
},
{
"href": "/remotectrl/vs/0",
"rep": {
"x.com.samsung.da.remoteControlEnabled": "false"
}
},
{
"href": "/st/airdressercourse/vs/0",
"rep": {
"x.com.samsung.da.st.airdresserMode": "Table_00_Course_01",
"x.com.samsung.da.st.courseTable": "Table_00"
}
},
{
"href": "/timezone/vs/0",
"rep": {
"timezoneid": "Asia/Seoul",
"offset": "+09:00",
"DST": "OFF"
}
},
{
"href": "/washer/vs/0",
"rep": {
"x.com.samsung.da.wrinklePrevent": "Off"
}
},
{
"href": "/wirelessinfo/vs/0",
"rep": {
"macaddressWiFi": "REDACTED",
"macaddressBLE": "REDACTED"
}
},
{
"href": "/wm/editcourse/vs/0",
"rep": {
"x.com.samsung.da.editCourseList": "EditCourseList_0135030E040A130B12090C10311416172119200F27302A2B2C2D2E151A1B1C0708",
"x.com.samsung.da.fixedCourseList": "FixedCourseList_01270F"
}
},
{
"href": "/wm/jobbeginingstatus/vs/0",
"rep": {}
},
{
"href": "/wm/personalcourse/vs/0",
"rep": {
"x.com.samsung.da.courses": [
"F1_00",
"F2_00",
"F3_00",
"F4_00",
"F5_00",
"F6_00",
"F7_00",
"F8_00",
"F9_00",
"FA_00"
],
"x.com.samsung.da.maxCourseNum": "10"
}
},
{
"href": "/wm/setinfo/vs/0",
"rep": {
"x.com.samsung.da.isModelSettingWithoutSC": "false",
"x.com.samsung.da.aiCourse": "false",
"x.com.samsung.da.isModelSettingPowerOnOff": "true",
"x.com.samsung.da.modelCode": "M(None),W(None)"
}
},
{
"href": "/wm/welcomemsg/vs/0",
"rep": {}
}
]
}
+184
View File
@@ -0,0 +1,184 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/airqualitystandard/vs/0",
"rep": {
"x.com.samsung.da.standard": "AirCleanAssociation"
}
},
{
"href": "/alarms/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "ErrorCode_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-30T02:42:57",
"x.com.samsung.da.state": "Deleted"
}
],
"rt": [
"x.com.samsung.da.alarms"
],
"if": [
"oic.if.baseline",
"oic.if.a"
]
}
},
{
"href": "/dnd/vs/0",
"rep": {
"x.com.samsung.da.value": "false",
"x.com.samsung.da.startTime": "14:00:00",
"x.com.samsung.da.endTime": "22:00:00",
"x.com.samsung.da.visible": "true"
}
},
{
"href": "/energy/battery/vs/0",
"rep": {
"x.com.samsung.da.battery": "80",
"x.com.samsung.da.batteryResolution": "1",
"x.com.samsung.da.charging": "Off"
}
},
{
"href": "/humidity/vs/0",
"rep": {
"x.com.samsung.da.humidity": "57",
"x.com.samsung.da.validity": "Valid"
}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "ASM-KR-TP1-22-ACMB1M|10243041|75000000001611C40800020000080000",
"x.com.samsung.da.description": "ASM-KR-TP1-22-ACMB1M",
"x.com.samsung.da.serialNum": "REDACTED",
"x.com.samsung.da.otnDUID": "REDACTED",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02443A260310",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "22050300",
"x.com.samsung.da.newVersionAvailable": "0"
}
],
"x.com.samsung.da.diagProtocolType": "WIFI_HTTPS",
"x.com.samsung.da.diagLogType": [
"errCode",
"dump"
],
"x.com.samsung.da.diagDumpType": "file",
"x.com.samsung.da.diagEndPoint": "SSM",
"x.com.samsung.da.diagMnid": "0AJT",
"x.com.samsung.da.diagSetupid": "AM0",
"x.com.samsung.da.diagMinVersion": "1.0"
}
},
{
"href": "/keepnormalstate/vs/0",
"rep": {
"x.com.samsung.da.keepnormal": 0
}
},
{
"href": "/realtimenotiforclient/vs/0",
"rep": {
"x.com.samsung.da.timeforshortnoti": "0",
"x.com.samsung.da.longnotisubscription": "true",
"x.com.samsung.da.periodicnotisubscription": "true"
}
},
{
"href": "/sensordatasinks/vs/0",
"rep": {
"remove": ""
}
},
{
"href": "/sensors/vs/0",
"rep": {
"x.com.samsung.da.cleanLevel": "2",
"x.com.samsung.da.refresh": "Off",
"x.com.samsung.da.lastSensingTime": "1785379376",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Sensor for CleanLevel",
"x.com.samsung.da.type": "CleanLevel",
"x.com.samsung.da.value": [
"2"
]
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Sensor for Odor",
"x.com.samsung.da.type": "Odor",
"x.com.samsung.da.value": [
"1"
]
},
{
"x.com.samsung.da.id": "2",
"x.com.samsung.da.description": "Sensor for Dust",
"x.com.samsung.da.type": "Dust",
"x.com.samsung.da.value": [
"31",
"2"
]
},
{
"x.com.samsung.da.id": "3",
"x.com.samsung.da.description": "Sensor for FineDust",
"x.com.samsung.da.type": "FineDust",
"x.com.samsung.da.value": [
"23",
"2"
]
},
{
"x.com.samsung.da.id": "4",
"x.com.samsung.da.description": "Sensor for SuperFineDust",
"x.com.samsung.da.type": "SuperFineDust",
"x.com.samsung.da.value": [
"18",
"2"
]
},
{
"x.com.samsung.da.id": "5",
"x.com.samsung.da.description": "Sensor for CO2",
"x.com.samsung.da.type": "CO2",
"x.com.samsung.da.value": [
"498",
"1"
]
}
]
}
}
]
}
+24
View File
@@ -0,0 +1,24 @@
{
"state_keys": [
"alarm_code",
"buzzer_sound",
"child_lock",
"completion_minutes",
"cycle",
"cycle_active",
"delay_start_hours",
"diagnosis_status",
"energy_kwh",
"energy_saved_kwh",
"finish_time",
"firmware_update",
"job_beginning_status",
"machine_state",
"power_switch",
"progress",
"progress_percentage",
"remote_control",
"sanitize",
"wrinkle_prevent"
]
}
+18
View File
@@ -0,0 +1,18 @@
{
"state_keys": [
"air_quality_standard",
"alarm_code",
"battery",
"battery_charging",
"clean_level",
"co2",
"dnd",
"dnd_end",
"dnd_start",
"dust",
"fine_dust",
"humidity",
"odor",
"super_fine_dust"
]
}
+1 -1
View File
@@ -166,7 +166,7 @@
"href": "/favorite/hotwater/vs/0",
"rep": {
"x.com.samsung.da.favorite.revision": "0",
"x.com.samsung.da.favorite.defaultTemperature": "85",
"x.com.samsung.da.favorite.defaultTemperature": "50",
"x.com.samsung.da.favorite.showList": [
"40",
"50",
+15
View File
@@ -539,3 +539,18 @@ def test_is_placeholder_serial_accepts_real_serials():
from custom_components.localthings.config_flow import _is_placeholder_serial
assert _is_placeholder_serial('0A1B2C3D4E5F') is False
assert _is_placeholder_serial('') is False
def test_is_placeholder_serial_catches_all_same_hex_digit():
"""Issue #189: the DA_WM_A51_20_COMMON (ARTIK051) laundry board family
reports a flash-unset sentinel instead of 'Nothing(SVC)' -- every
character the same repeated hex digit. A washer and a dryer, two
different physical units, both reported the literal serialNum
'FFFFFFFFFFFFFFF', colliding on the config-entry unique_id."""
from custom_components.localthings.config_flow import _is_placeholder_serial
assert _is_placeholder_serial('FFFFFFFFFFFFFFF') is True
assert _is_placeholder_serial('ffffffffffffffff') is True
assert _is_placeholder_serial('00000000') is True
# Too short to be the flash-unset sentinel -- a real serial could
# plausibly repeat one hex digit seven times by chance.
assert _is_placeholder_serial('FFFFFFF') is False
+39 -1
View File
@@ -15,7 +15,7 @@ from custom_components.localthings.const import (
SUMMARY_INTERVAL_S,
)
from custom_components.localthings.coordinator import (
LocalThingsCoordinator, _local_source_port,
LocalThingsCoordinator, _is_placeholder_serial, _local_source_port,
)
from custom_components.localthings.registry.capabilities.common import (
remote_control_enabled,
@@ -163,6 +163,44 @@ def test_run_discovery_falls_back_to_host_for_placeholder_serial(
assert coordinator.device_serial == mock_entry.data[CONF_HOST]
def test_run_discovery_falls_back_to_host_for_all_f_placeholder_serial(
hass: HomeAssistant, mock_entry
) -> None:
"""Issue #189: the DA_WM_A51_20_COMMON (ARTIK051) laundry board family
reports a flash-unset sentinel instead of 'Nothing(SVC)' -- every
character the same repeated hex digit. A washer and a dryer, two
different physical units, both reported the literal serialNum
'FFFFFFFFFFFFFFF', so without this fallback they'd collide on
device_serial exactly like the #83 case above."""
resources = {
'/information/vs/0': {
'x.com.samsung.da.modelNum':
'DA_WM_A51_20_COMMON|20221341|30010102001211000103000000000000',
'x.com.samsung.da.description':
'DA_WM_A51_20_COMMON_DVE50A8800/DC92-02835A_0080',
'x.com.samsung.da.serialNum': 'FFFFFFFFFFFFFFF',
},
'/otninformation/vs/0': {},
}
coordinator = LocalThingsCoordinator(hass, mock_entry)
coordinator._run_discovery(resources)
assert coordinator.device_serial == mock_entry.data[CONF_HOST]
def test_is_placeholder_serial_catches_all_same_hex_digit():
assert _is_placeholder_serial('FFFFFFFFFFFFFFF') is True
assert _is_placeholder_serial('ffffffffffffffff') is True
assert _is_placeholder_serial('00000000') is True
def test_is_placeholder_serial_accepts_real_serials_and_short_runs():
assert _is_placeholder_serial('0A1B2C3D4E5F') is False
assert _is_placeholder_serial('') is False
# Too short to be the flash-unset sentinel -- a real serial could
# plausibly repeat one hex digit seven times by chance.
assert _is_placeholder_serial('FFFFFFF') is False
def test_run_discovery_detects_cooktop_via_resource_signature(
hass: HomeAssistant, mock_entry
) -> None:
@@ -0,0 +1,79 @@
"""Tests for the DA_DF_TP1_21_COMMON AirDresser (model DF3000B, issue #208).
Another board generation routed into the same air_dresser registry as
issue #162's DA_DF_A51_20_COMMON and issue #157's DA_DF_TP2_20_COMMON.
Exercises the one thing this board reports that neither of those does:
a populated /buzzersound/vs/0 (laundry.BUZZER_SOUND) -- the reporter's
actual ask ("all cycles are represented by code") is a course-code
labelling problem, not a coverage one; this board's course table isn't
identified yet either (same as #162's), so 'cycle' still renders as the
raw code until a reporter can map codes to names in the SmartThings app.
"""
from custom_components.localthings.registry.adapter import flatten
from custom_components.localthings.registry.by_type import air_dresser, for_device_by_model
from custom_components.localthings.registry.discovery import discover
from tests.conftest import _load_device
def _air_dresser():
resources = _load_device('air_dresser_tp1_21')
info = resources['/information/vs/0']
reg = for_device_by_model(
info['x.com.samsung.da.modelNum'], info['x.com.samsung.da.description'])
return reg, resources
def _state():
reg, resources = _air_dresser()
bound = discover(resources, reg.capabilities, reg.pattern_capabilities)
return flatten(bound, resources)
def test_resolves_to_air_dresser_registry():
reg, _ = _air_dresser()
assert reg is not None and reg.name == 'air_dresser'
def test_no_unbound_hrefs():
reg, resources = _air_dresser()
unbound = []
discover(resources, reg.capabilities, reg.pattern_capabilities, log=unbound.append)
assert unbound == []
def test_buzzer_sound_present_and_writable():
"""Issue #208's actual coverage gap: /buzzersound/vs/0 was unbound on
this board before laundry.BUZZER_SOUND was added to the registry."""
state = _state()
assert state['buzzer_sound'] == 'On'
assert 'finish_sound' not in state # supportedFinishSound absent -- self-gated off
desc = next(
e for e in air_dresser.REGISTRY.capabilities['/buzzersound/vs/0'][0].entities
if e.key == 'buzzer_sound'
)
path, body = desc.write_fn('Off', {})
assert path == ['buzzersound', 'vs', '0']
assert body == {'setBuzzerSound': 'Off'}
def test_course_translation_key_falls_back_to_cycle_for_unidentified_table():
"""Same as issue #162's board: Table_00's course codes aren't
identified yet, so the select renders raw codes rather than names."""
_, resources = _air_dresser()
desc = air_dresser.REGISTRY.capabilities['/course/vs/0'][0].entities[0]
assert desc.translation_key(resources) == 'cycle'
def test_sanitize_present_and_toggles():
state = _state()
assert state['sanitize'] is False
desc = next(
e for e in air_dresser.REGISTRY.capabilities['/airdresseroption/sanitize/vs/0'][0].entities
if e.key == 'sanitize'
)
path, body = desc.write_fn('On', {})
assert path == ['airdresseroption', 'sanitize', 'vs', '0']
assert body == {'x.com.samsung.da.sanitize': 'On'}
+115
View File
@@ -0,0 +1,115 @@
"""Tests for the Samsung Air Monitor Plus family (ASM-KR-TP1-22-ACMB1M,
issue #210) -- a standalone, battery-powered air-quality sensor puck. No
controllable appliance state at all beyond the do-not-disturb window.
"""
from datetime import time as dt_time
from custom_components.localthings.registry.adapter import flatten
from custom_components.localthings.registry.by_type import for_device_by_oic_type, resolve
from custom_components.localthings.registry.discovery import discover
from tests.conftest import _load_device
def _air_monitor():
resources = _load_device('air_monitor')
reg = resolve(resources)
return reg, resources
def _bound():
reg, resources = _air_monitor()
return discover(resources, reg.capabilities, reg.pattern_capabilities), resources
def _state():
bound, resources = _bound()
return flatten(bound, resources)
def _desc(key):
bound, _ = _bound()
return next(b.desc for b in bound if b.desc.key == key)
def test_resolves_to_air_monitor_registry():
reg, _ = _air_monitor()
assert reg is not None and reg.name == 'air_monitor'
def test_resolves_via_oic_type_too():
"""This board's real dump carries /oic/d's device type
('x.com.st.d.airqualitysensor') as well as the 'ASM' modelNum token --
both paths must agree."""
reg = for_device_by_oic_type(('x.com.st.d.airqualitysensor',))
assert reg is not None and reg.name == 'air_monitor'
def test_no_unbound_hrefs():
reg, resources = _air_monitor()
unbound = []
discover(resources, reg.capabilities, reg.pattern_capabilities, log=unbound.append)
assert unbound == []
def test_air_quality_sensors_read_from_shared_items_decode():
"""Same /sensors/vs/0 {type, value} shape and common.sensor_item_value
decode air_purifier.AIR_QUALITY already uses -- this board adds CO2,
which neither air_purifier nor range_hood report."""
state = _state()
assert state['dust'] == 31
assert state['fine_dust'] == 23
assert state['super_fine_dust'] == 18
assert state['odor'] == 1
assert state['clean_level'] == 2
assert state['co2'] == 498
def test_second_value_slot_is_not_exposed():
"""Dust/fine_dust/super_fine_dust each carry a second `value[1]` grade
code (e.g. Dust's ['31', '2']) with no supported-values field anywhere
in the dump to explain its scale -- per the 'still never invent... from
nothing' rule, only the raw reading (value[0]) is bound, not a second
'dust_level' or similar entity for that code."""
state = _state()
assert 'dust_level' not in state
assert 'dust_grade' not in state
def test_humidity_and_battery_present():
state = _state()
assert state['humidity'] == 57
assert state['battery'] == 80
assert state['battery_charging'] is False
def test_air_quality_standard_present():
state = _state()
assert state['air_quality_standard'] == 'AirCleanAssociation'
def test_dnd_read_contract():
state = _state()
assert state['dnd'] is False
assert state['dnd_start'] == dt_time(14, 0)
assert state['dnd_end'] == dt_time(22, 0)
def test_dnd_write_contracts_are_flagged_educated_guesses():
"""Issue #210: no idle-vs-active dump pair exists for /dnd/vs/0 (DND
was never toggled in the one dump this board has), so these write
contracts are educated guesses -- symmetric with the read side's own
string/time-format shape, not invented from nothing, but still
unconfirmed on real hardware. Only the wiring is tested here; whether
the device actually accepts these writes needs a reporter to confirm."""
dnd = _desc('dnd')
path, body = dnd.write_fn('On', {})
assert path == ['dnd', 'vs', '0']
assert body == {'x.com.samsung.da.value': 'true'}
path, body = dnd.write_fn('Off', {})
assert body == {'x.com.samsung.da.value': 'false'}
start = _desc('dnd_start')
path, body = start.write_fn(dt_time(9, 30), {})
assert path == ['dnd', 'vs', '0']
assert body == {'x.com.samsung.da.startTime': '09:30:00'}
+14
View File
@@ -151,6 +151,7 @@ class TestForDeviceByOicType:
('oic.d.washer', 'washer'),
('x.com.st.d.stickcleaner', 'vacuum_station'),
('x.com.st.d.steamcloset', 'air_dresser'),
('x.com.st.d.airqualitysensor', 'air_monitor'),
])
def test_known_oic_types_resolve(self, oic_type, expected):
from custom_components.localthings.registry.by_type import for_device_by_oic_type
@@ -434,6 +435,19 @@ class TestForDeviceByModel:
assert reg is not None
assert reg.name == 'vacuum_station'
def test_air_monitor_via_asm_token(self):
"""Issue #210: a standalone air-quality sensor puck
(ASM-KR-TP1-22-ACMB1M) reports no oneUiVersion and no
washer/dryer/dishwasher consumer prefix; falls back to the 'ASM'
token in modelNum onto the air_monitor registry."""
from custom_components.localthings.registry.by_type import for_device_by_model
reg = for_device_by_model(
'ASM-KR-TP1-22-ACMB1M|10243041|75000000001611C40800020000080000',
'ASM-KR-TP1-22-ACMB1M',
)
assert reg is not None
assert reg.name == 'air_monitor'
def test_cooktop_via_legacy_model_description(self):
"""Older cooktops identify themselves as ARTIK051_GLOBAL_COOKTOP."""
from custom_components.localthings.registry.by_type import for_device_by_model
+27 -7
View File
@@ -15,9 +15,13 @@ def _reg():
def test_kids_lock_vs_value_fn():
"""binary_sensor's 'lock' device class is inverted from a plain on/off
switch: On means open/unlocked (issues #181/#183 -- see
TestKidsLockFallback.test_vs_fallback_is_read_only for why this is a
binary_sensor at all)."""
desc = common.KIDS_LOCK_VS_FALLBACK.entities[0]
assert desc.value_fn('Lock') is True
assert desc.value_fn('Ready') is False
assert desc.value_fn('Lock') is False
assert desc.value_fn('Ready') is True
def test_common_caps_discover_on_dishwasher(dishwasher_resources):
@@ -228,19 +232,35 @@ class TestWmSetinfoFlags:
class TestKidsLockFallback:
def test_generic_read_write(self):
def test_generic_is_read_only(self):
"""Issues #181/#183: the kids-lock resource is read-only on real
hardware (writing the *correct* value still 4.05s, and no
SwitchDesc device_class='lock' is honored by HA -- the switch
platform only accepts 'outlet'/'switch'). KIDS_LOCK_GENERIC and
KIDS_LOCK_VS_FALLBACK now share the same shape (BinarySensorDesc,
device_class='lock', same key) so both surfaces render with the
same polarity: 'On' means open/unlocked."""
assert common.KIDS_LOCK_GENERIC.href == '/kidslock/0'
desc = common.KIDS_LOCK_GENERIC.entities[0]
assert desc.value_fn(True) is True
path, body = desc.write_fn('On', {})
assert path == ['kidslock', '0']
assert body == {'value': True}
assert isinstance(desc, BinarySensorDesc)
assert desc.value_fn(False) is True # value=False -> On=Unlocked
assert desc.value_fn(True) is False # value=True -> Off=Locked
def test_vs_fallback_gated(self):
assert common.KIDS_LOCK_VS_FALLBACK.match_fn({}, {'/kidslock/vs/0': {}}) is True
assert common.KIDS_LOCK_VS_FALLBACK.match_fn(
{}, {'/kidslock/0': {}, '/kidslock/vs/0': {}}) is False
def test_vs_fallback_is_read_only(self):
"""Issues #181/#183: writing this resource 4.05s on real hardware
even with the *correct* value ('Run'), and no dump in the fixture
corpus has ever reported the value this used to write ('Enable')
back -- every one reports 'Ready' or 'Run'. Never a confirmed write
contract, so it's a binary_sensor (no write_fn field at all), not
a switch."""
desc = common.KIDS_LOCK_VS_FALLBACK.entities[0]
assert isinstance(desc, BinarySensorDesc)
class TestRemoteControlFallback:
def test_generic_read(self):
+44
View File
@@ -869,6 +869,50 @@ def test_registry_reproduces_golden_state_keys_for_air_dresser_tp2_20():
)
def test_registry_reproduces_golden_state_keys_for_air_dresser_tp1_21():
"""DA_DF_TP1_21_COMMON AirDresser (model DF3000B, issue #208) -- another
board generation routed via the '_DF_' modelNum token fallback into the
same air_dresser registry as #162's and #157's boards (its dump also
happens to be the first AirDresser one to carry /oic/d's device type,
'x.com.st.d.steamcloset' -- see test_by_type.py's
TestForDeviceByOicType for that mapping's own coverage). The first
AirDresser dump to report /buzzersound/vs/0 (laundry.BUZZER_SOUND,
added for this issue -- #162's and #157's boards don't report it at
all). Binds cleanly with zero unbound hrefs; course codes for this
board's table still aren't identified (same as #162's), so 'cycle'
remains the raw code rather than a table-specific translation."""
from tests.conftest import _load_device
resources = _load_device('air_dresser_tp1_21')
golden = json.loads((GOLDEN / 'air_dresser_tp1_21.json').read_text())
state_keys = _new_state_keys('air_dresser_tp1_21', resources)
assert set(state_keys) == set(golden['state_keys']), (
f"state_keys mismatch:\n"
f" extra: {sorted(set(state_keys) - set(golden['state_keys']))}\n"
f" missing: {sorted(set(golden['state_keys']) - set(state_keys))}"
)
def test_registry_reproduces_golden_state_keys_for_air_monitor():
"""Samsung Air Monitor Plus (ASM-KR-TP1-22-ACMB1M, issue #210) -- a
standalone battery-powered air-quality sensor puck, the first device
this integration has no controllable-appliance concept for at all (no
/power/*, only /energy/battery/vs/0). Routes via both /oic/d
('x.com.st.d.airqualitysensor') and the 'ASM' modelNum board token.
Reuses air_purifier.AIR_QUALITY's /sensors/vs/0 decode
(common.sensor_item_value) for dust/fine_dust/super_fine_dust/odor/
clean_level, adding a CO2 reading those families don't report. Binds
cleanly with zero unbound hrefs."""
from tests.conftest import _load_device
resources = _load_device('air_monitor')
golden = json.loads((GOLDEN / 'air_monitor.json').read_text())
state_keys = _new_state_keys('air_monitor', resources)
assert set(state_keys) == set(golden['state_keys']), (
f"state_keys mismatch:\n"
f" extra: {sorted(set(state_keys) - set(golden['state_keys']))}\n"
f" missing: {sorted(set(golden['state_keys']) - set(state_keys))}"
)
def test_registry_reproduces_golden_state_keys_for_air_purifier_vtww():
"""A-VTWW-TP2-21-COMMON BESPOKE Cube Air (issue #151) -- reports no
oneUiVersion; resolved via the '-VTWW-' modelNum token fallback into
+6 -3
View File
@@ -56,7 +56,10 @@ def test_energy_saving_and_cooktop_alert_present():
def test_child_lock_already_reads_correctly():
"""issue #183 also reported child lock as unreadable -- but this dump's
/kidslock/vs/0 ('Run') and /doors/vs/0's door lock field ('Lock') already
agree the door is locked, and the existing common.KIDS_LOCK_VS_FALLBACK
already reads that correctly with no code change needed."""
agree the door is locked, and common.KIDS_LOCK_VS_FALLBACK already reads
that correctly with no further code change needed. Now a read-only
binary_sensor (issues #181/#183 -- the write side was never a confirmed
contract), whose 'lock' device class is inverted from a switch's plain
on/off: False means locked/closed, matching 'Run' here."""
state = _state()
assert state['child_lock'] is True
assert state['child_lock'] is False
+32 -2
View File
@@ -281,9 +281,17 @@ def test_hotwater_lock_fallback_gating_across_status_lock_states():
assert fallback.exists_fn({}, {}) is False
def test_favorite_hotwater_temperature_options_come_from_live_supported_list():
def test_favorite_hotwater_temperature_options_come_from_live_show_list():
"""`supportedList` is only the four fixed presets -- `showList` is a
superset that also carries the one custom value (if any) the
SmartThings app's "temperatures to display" editor let the user add,
and always includes whatever the current default actually is. Reading
`supportedList` meant a unit whose default *was* that custom value
rendered as 'unknown' in HA (issue #196) -- see the ailite fixture's
version of this test below for the case that actually exercises it
(this fixture's showList == supportedList, no custom value set)."""
desc = _desc_coffee('favorite_hotwater_temperature')
assert desc.options_field == 'x.com.samsung.da.favorite.supportedList'
assert desc.options_field == 'x.com.samsung.da.favorite.showList'
def test_coffee_recipe_hrefs_are_ignored_not_guessed():
@@ -361,6 +369,28 @@ def test_ailite_hot_water_temperature_gated_off_without_supported_list():
assert 'hot_water_temperature' not in state
def test_ailite_favorite_hotwater_temperature_options_include_the_custom_value():
"""Issue #196's concrete failure case: the user added a custom 50C value
via the SmartThings app's "temperatures to display" editor, so the
board's defaultTemperature is now '50'. showList contains '50'
([40, 50, 75, 85, 90]) but supportedList does NOT (still the fixed
[40, 75, 85, 90]). Reading options_field='x.com.samsung.da.favorite.supportedList'
-- the old behavior -- would register a select whose options list
doesn't contain the current default, so HA would render the entity as
'unknown'. The descriptor must read from showList so '50' is in
options."""
desc = _desc_ailite('favorite_hotwater_temperature')
assert desc.options_field == 'x.com.samsung.da.favorite.showList'
_, resources = _water_purifier_ailite()
rep = resources['/favorite/hotwater/vs/0']
# defaultTemperature='50' must be a member of the field the descriptor
# actually reads -- this is the precise assertion that would fail under
# the old supportedList behavior.
assert rep['x.com.samsung.da.favorite.defaultTemperature'] == '50'
assert '50' in rep[desc.options_field]
assert '50' not in rep['x.com.samsung.da.favorite.supportedList']
def test_ailite_sound_mode_options_come_from_live_supported_modes():
"""This board's supportedModes (voice/fixedTone/mute) differs from both
laundry.SOUND_MODE's hardcoded voice/tone/mute and air_purifier.SOUND_MODE's