@@ -222,8 +222,23 @@ def _is_placeholder_serial(serial: str) -> bool:
serial` check here (and the equivalent one in coordinator.py's
`_run_discovery`) doesn't catch it, and two such units get the same
config-entry unique_id / entity unique_ids and collide (issue #83).
Issue #189: the DA_WM_A51_20_COMMON (ARTIK051) laundry board family
reports a flash-unset sentinel instead -- every character the same
repeated hex digit (a washer and a dryer, two different physical
units, both reported the literal serialNum 'FFFFFFFFFFFFFFF') -- which
the 'nothing' check above doesn't catch either, so the second unit's
config flow aborted as already configured.
"""
return serial.strip().lower().startswith('nothing')
s = serial.strip()
if s.lower().startswith('nothing'):
return True
upper = s.upper()
return (
len(upper) >= 8
and len(set(upper)) == 1
and upper[0] in '0123456789ABCDEF'
)
def _probe_and_validate(host: str, ca_cert_pem: str, ca_key_pem: str) -> dict:
+31 -7
View File
@@ -92,12 +92,30 @@ def _is_placeholder_serial(serial: str) -> bool:
serial` check below doesn't catch it, and `device_serial` feeds both
the HA device-registry identifier and every entity's unique_id
(entity.py), so two such units on the same install silently collide
and the second one's entities get dropped (issue #83). Mirrors the
identical helper in config_flow.py's `_probe_and_validate` -- kept
separate rather than imported to avoid pulling the config-flow module
into the runtime coordinator's import graph for a two-line check.
and the second one's entities get dropped (issue #83).
Issue #189: the DA_WM_A51_20_COMMON (ARTIK051) laundry board family
reports a flash-unset sentinel instead -- every character the same
repeated hex digit (a washer and a dryer, two different physical
units, both reported the literal serialNum 'FFFFFFFFFFFFFFF') -- which
the 'nothing' check above doesn't catch either, so two such units
collided on the config-entry unique_id and the second couldn't be
added at all.
Mirrors the identical helper in config_flow.py's `_probe_and_validate`
-- kept separate rather than imported to avoid pulling the config-flow
module into the runtime coordinator's import graph for a two-line
check.
"""
return serial.strip().lower().startswith('nothing')
s = serial.strip()
if s.lower().startswith('nothing'):
return True
upper = s.upper()
return (
len(upper) >= 8
and len(set(upper)) == 1
and upper[0] in '0123456789ABCDEF'
)
class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
@@ -918,9 +936,15 @@ class LocalThingsCoordinator(DataUpdateCoordinator[dict[str, Any]]):
# Schedule sub-polls for hot/warm hrefs between summary polls
# (no-op in observe-primary mode unless this cycle's sweep found a
# mismatch; _run_subpolls checks the mode/force).
# mismatch; _run_subpolls checks the mode/force). A background task,
# not async_create_task: this loop is self-limiting (cancelled and
# recreated every refresh cycle, see the cancel() above) and owned
# entirely by the coordinator, so it has no business being tracked by
# HA's own startup/shutdown sequencing -- async_create_task ties it
# in regardless, so a subpoll cycle in flight (up to ~27s,
# _SUBPOLL_STEP_S x 9 slots) delays both (issue #207).
if self._hot_hrefs or self._warm_hrefs:
self._subpoll_task = self.hass.async_create_task(
self._subpoll_task = self.hass.async_create_background_task(
self._run_subpolls(force=sweep_mismatch), name="localthings_subpoll"
)
@@ -4,9 +4,10 @@ from typing import Optional, Sequence
from ._base import DeviceRegistry
from . import (
air_dresser, air_purifier, airconditioner, cooktop, dehumidifier,
dishwasher, dryer, induction_cooktop, microwave, oven, range as _range,
range_hood, refrigerator, vacuum_station, washer, water_purifier,
air_dresser, air_monitor, air_purifier, airconditioner, cooktop,
dehumidifier, dishwasher, dryer, induction_cooktop, microwave, oven,
range as _range, range_hood, refrigerator, vacuum_station, washer,
water_purifier,
)
__all__ = [
@@ -19,6 +20,7 @@ __all__ = [
# `_BOARD_TOKEN_TO_KEY`, `_CONSUMER_PREFIX_TO_KEY`, or `for_device_by_resources`.
_REGISTRY_BY_KEY: dict[str, DeviceRegistry] = {
'air_dresser': air_dresser.REGISTRY,
'air_monitor': air_monitor.REGISTRY,
'air_purifier': air_purifier.REGISTRY,
'airconditioner': airconditioner.REGISTRY,
'cooktop': cooktop.REGISTRY,
@@ -111,7 +113,8 @@ _BOARD_TOKEN_TO_KEY: dict[str, str] = {
'CT': 'cooktop',
'VSKR': 'vacuum_station', # issue #131 -- stick-vacuum clean station
'DF': 'air_dresser', # issue #162
'VSWW': 'vacuum_station', # issue #219
'VSWW': 'vacuum_station', # issue #219
'ASM': 'air_monitor', # issue #210 -- Air Monitor Plus
}
_TOKEN_SPLIT_RE = re.compile(r'[^A-Z0-9]+')
@@ -219,6 +222,7 @@ _OIC_TYPE_TO_KEY: dict[str, str] = {
'oic.d.oven': 'oven',
'oic.d.refrigerator': 'refrigerator',
'oic.d.washer': 'washer',
'x.com.st.d.airqualitysensor': 'air_monitor',
'x.com.st.d.stickcleaner': 'vacuum_station',
'x.com.st.d.steamcloset': 'air_dresser',
}
@@ -1,7 +1,10 @@
"""AirDresser device registry (issue #162).
Reuses washer/dryer/dishwasher's shared laundry surface -- job-beginning
status, operational state, and diagnosis. air_dresser.py holds the two
status, operational state, diagnosis, and (issue #208) the buzzer-sound
select -- /buzzersound/vs/0's rep on this board is the plain
{setBuzzerSound, supportedBuzzerSound} shape laundry.BUZZER_SOUND already
expects, no AirDresser-specific wiring needed. air_dresser.py holds the two
pieces specific to this device type: a minimal wrinkle-prevent-only
/washer/vs/0 capability, and the course select's own translation key.
"""
@@ -17,6 +20,7 @@ REGISTRY = DeviceRegistry(
air_dresser.AIR_DRESSER_SETTINGS,
air_dresser.AIR_DRESSER_COURSE,
air_dresser.AIR_DRESSER_SANITIZE,
laundry.BUZZER_SOUND,
laundry.JOB_BEGINNING_STATUS,
operational.OPERATIONAL_STATE,
dishwasher.DIAGNOSIS,
@@ -0,0 +1,23 @@
"""Air Monitor Plus device registry (issue #210).
A standalone, battery-powered air-quality sensor puck (ASM-KR-TP1-22-*
board) -- no controllable state at all beyond the do-not-disturb window,
so this registry is almost entirely sensors. No common.POWER: there's no
`/power/*` resource on this board, only `/energy/battery/vs/0`.
"""
from ..capabilities import air_monitor, common, ignored
from ._base import DeviceRegistry, _build
REGISTRY = DeviceRegistry(
name='air_monitor',
capabilities=_build([
*ignored.IGNORED,
*common.UNIVERSAL,
*air_monitor.COVERAGE,
air_monitor.SENSORS,
air_monitor.HUMIDITY,
air_monitor.BATTERY,
air_monitor.AIR_QUALITY_STANDARD,
air_monitor.DND,
]),
)
@@ -0,0 +1,155 @@
"""Capabilities for the Samsung Air Monitor Plus family (ASM-KR-TP1-22-*
board, issue #210) -- a small battery-powered standalone air-quality sensor
puck, not a controllable appliance. No `/power/*` resource at all (battery
only); this registry deliberately doesn't include common.POWER.
`/sensors/vs/0` is the same {type, value: [...]} items-list shape
air_purifier.AIR_QUALITY and range_hood.AIR_QUALITY already read via
common.sensor_item_value -- reused here rather than re-decoded, including
the same dust/fine_dust/super_fine_dust/odor/clean_level keys so this
device shares those capabilities' catalog entries. This board additionally
reports a CO2 reading the other two families don't.
A second `value` list element on the particulate-matter types (e.g. Dust's
`['31', '2']`) reads like a coarse quality-grade code, but nothing on this
board (no `supportedGrades`/similar field, no repeated dump to compare
against) confirms what its scale means -- left unbound rather than guessed,
per the adding-device-support skill's "still never invent... from nothing"
rule. Same reasoning `air_purifier.AIR_QUALITY` already applies to this
shape; index 0 is the only slot any family has ever read.
Dust/FineDust/SuperFineDust aren't assigned an HA `device_class`
(pm10/pm25/pm1) or `unit` despite the values reading like plausible
ug/m3 particulate readings in a physically consistent order (coarser
>= finer): Samsung's own two-tier Korean convention (i.e. "fine dust"/
"ultra-fine dust") maps only to a PM10/PM2.5 pair, and this board's
three-tier naming doesn't confirm where the extra tier or a PM1 reading
actually fits. The adding-device-support skill's read-side rule says
leave unit/device_class unset when the dump gives no field that
nominates one -- a wrong guess would silently mislabel every reading
forever, and the write-side rejection safety net doesn't cover reads.
Exposed as plain `measurement` sensors named after the device's own
field instead (matching air_purifier.AIR_QUALITY's existing precedent).
"""
from datetime import time as dt_time
from ..capability import Capability
from ..entities import BinarySensorDesc, SensorDesc, SwitchDesc, TimeDesc
from .air_purifier import _AIR_QUALITY_SENSORS
from .common import int_or_none, sensor_item_value
SENSORS = Capability(
href='/sensors/vs/0',
poll_tier='warm',
entities=tuple(
SensorDesc(key=key, field='x.com.samsung.da.items', icon=icon,
state_class='measurement',
value_fn=lambda items, t=sensor_type: sensor_item_value(items, t))
for key, icon, sensor_type in _AIR_QUALITY_SENSORS
) + (
SensorDesc(key='co2', field='x.com.samsung.da.items',
device_class='carbon_dioxide', state_class='measurement',
unit='ppm',
value_fn=lambda items: sensor_item_value(items, 'CO2')),
),
)
HUMIDITY = Capability(
href='/humidity/vs/0',
poll_tier='warm',
entities=(
SensorDesc(key='humidity', field='x.com.samsung.da.humidity',
device_class='humidity', state_class='measurement',
unit='%', value_fn=int_or_none),
),
)
BATTERY = Capability(
href='/energy/battery/vs/0',
poll_tier='warm',
entities=(
SensorDesc(key='battery', field='x.com.samsung.da.battery',
device_class='battery', state_class='measurement',
unit='%', entity_category='diagnostic',
value_fn=int_or_none),
BinarySensorDesc(key='battery_charging', field='x.com.samsung.da.charging',
device_class='battery_charging',
entity_category='diagnostic',
value_fn=lambda v: v == 'On'),
),
)
AIR_QUALITY_STANDARD = Capability(
href='/airqualitystandard/vs/0',
poll_tier='cold',
entities=(
SensorDesc(key='air_quality_standard', field='x.com.samsung.da.standard',
entity_category='diagnostic'),
),
)
def _parse_hms(v):
"""'HH:MM:SS' -> datetime.time, same contract as laundry._parse_hm but
tolerant of the trailing ':SS' this board's dnd start/end times carry."""
if not v:
return None
try:
parts = v.split(':')
return dt_time(int(parts[0]), int(parts[1]))
except (ValueError, IndexError):
return None
def _dnd_time_write(field):
def _write(p, rep, href=None):
return ['dnd', 'vs', '0'], {field: f'{p.hour:02d}:{p.minute:02d}:00'}
return _write
# Issue #210: no idle-vs-active dump pair exists for this href (only one
# dump total, DND never toggled in it), so this write contract is an
# educated guess, not a confirmed one -- symmetric with the read side
# (writing the same 'true'/'false' string shape and 'HH:MM:SS' format the
# device itself reports back) rather than invented from nothing, but still
# needs a reporter to actually flip it on real hardware and confirm. See
# the adding-device-support skill's "Educated guesses are fine" section.
DND = Capability(
href='/dnd/vs/0',
poll_tier='cold',
entities=(
SwitchDesc(key='dnd', field='x.com.samsung.da.value',
icon='mdi:sleep',
entity_category='config',
value_fn=lambda v: v == 'true',
write_fn=lambda p, rep, href=None: (
['dnd', 'vs', '0'],
{'x.com.samsung.da.value': 'true' if p == 'On' else 'false'})),
TimeDesc(key='dnd_start', field='x.com.samsung.da.startTime',
icon='mdi:clock-start',
entity_category='config',
value_fn=_parse_hms,
write_fn=_dnd_time_write('x.com.samsung.da.startTime')),
TimeDesc(key='dnd_end', field='x.com.samsung.da.endTime',
icon='mdi:clock-end',
entity_category='config',
value_fn=_parse_hms,
write_fn=_dnd_time_write('x.com.samsung.da.endTime')),
),
)
# ---------------------------------------------------------------------------
# Air-monitor-scoped coverage: hrefs with no explainable live state,
# following the 'don't guess' rule.
# ---------------------------------------------------------------------------
_AM_IGNORED = [
# A single bare integer ('keepnormal': 0) with no description, no
# supported-values list, and no second dump to compare against -- opaque.
'/keepnormalstate/vs/0',
# {'remove': ''} -- looks like data-sink/cache-clearing plumbing, not a
# live user-facing field.
'/sensordatasinks/vs/0',
]
COVERAGE = [Capability(href=h) for h in _AM_IGNORED]
@@ -228,8 +228,9 @@ def sensor_item_value(items, sensor_type, index=0):
"""Pull one reading out of a `/sensors/vs/0`-style items[] list -- each
item is `{type, value: [...]}`; `index` picks which slot of a possibly
multi-value reading to read (index 0 is the raw measurement on every
family seen so far). Shared by range_hood.AIR_QUALITY and
air_purifier.AIR_QUALITY, which read the same resource shape."""
family seen so far). Shared by range_hood.AIR_QUALITY,
air_purifier.AIR_QUALITY, and air_monitor.SENSORS, which all read the
same resource shape against the same {type, sensor_type} keys."""
for item in items or ():
if not isinstance(item, dict):
continue
@@ -301,11 +302,19 @@ POWER_VS_FALLBACK = Capability(
KIDS_LOCK_GENERIC = Capability(
href='/kidslock/0',
entities=(
SwitchDesc(key='child_lock', field='value',
device_class='lock',
value_fn=lambda v: bool(v),
write_fn=lambda p, rep, href=None: (
['kidslock', '0'], {'value': p == 'On'})),
# Read-only like KIDS_LOCK_VS_FALLBACK (issues #181/#183) -- not a
# SwitchDesc. SwitchDesc's `device_class='lock'` was never honored
# by HA (its switch platform only accepts 'outlet'/'switch'),
# leaving a plain switch whose 'On' state meant different things
# on different boards. As a BinarySensorDesc with `device_class='lock'`,
# both kids-lock surfaces read with the same polarity: 'On' means
# open/unlocked, per HA's lock device_class. The inversion in
# value_fn here (and in the fallback below) keeps the on-the-wire
# truth (value=False on /kidslock/0, kidsLock='Ready' on /kidslock/vs/0
# both mean kids lock NOT active) consistent with that polarity.
BinarySensorDesc(key='child_lock', field='value',
device_class='lock',
value_fn=lambda v: not bool(v)),
),
)
@@ -313,12 +322,19 @@ KIDS_LOCK_VS_FALLBACK = Capability(
href='/kidslock/vs/0',
match_fn=lambda rep, resources: '/kidslock/0' not in resources,
entities=(
SwitchDesc(key='child_lock', field='x.com.samsung.da.kidsLock',
device_class='lock',
value_fn=lambda v: v != 'Ready',
write_fn=lambda p, rep, href=None: (
['kidslock', 'vs', '0'],
{'x.com.samsung.da.kidsLock': 'Enable' if p == 'On' else 'Ready'})),
# Read-only, not a SwitchDesc (issues #181/#183): the write side of
# this capability wrote 'Enable', a value no dump in the fixture
# corpus has ever reported back -- every one reports either 'Ready'
# or 'Run', so it was never a confirmed contract. #181's reporter
# confirmed this directly: writing the *correct* value ('Run')
# still 4.05s, and the SmartThings app itself has no control for
# it either -- the resource is genuinely read-only on this
# hardware, not just wrong-valued. Polarity matches
# KIDS_LOCK_GENERIC above -- 'On' means open/unlocked, so
# kidsLock='Ready' (kids lock NOT active) renders as 'On'.
BinarySensorDesc(key='child_lock', field='x.com.samsung.da.kidsLock',
device_class='lock',
value_fn=lambda v: v == 'Ready'),
),
)
@@ -175,11 +175,23 @@ FAVORITE_HOTWATER = Capability(
write_fn=lambda p, rep, href=None: (
['favorite', 'hotwater', 'vs', '0'],
{'x.com.samsung.da.switchHotwater': 'Locked' if p == 'On' else 'Unlocked'})),
# Issue #196: `supportedList` is only the four *fixed* presets
# (e.g. ['40', '75', '85', '90']) -- the SmartThings app also lets
# the user add one custom value to their own display list via its
# "temperatures to display" editor (a wheel picker bounded by
# /setting/waterpurifier/vs/0's hotwaterRange, separate resource),
# and that custom value shows up in `showList`
# (['40', '50', '75', '85', '90'] here) but never in
# `supportedList`. Reading options from `supportedList` meant a
# unit whose current default *was* that custom value rendered as
# "unknown" -- not a coverage gap, just the wrong field. `showList`
# is a superset of `supportedList` that always includes whatever
# the current default actually is, custom or not.
SelectDesc(key='favorite_hotwater_temperature',
field='x.com.samsung.da.favorite.defaultTemperature',
icon='mdi:thermometer',
entity_category='config',
options_field='x.com.samsung.da.favorite.supportedList',
options_field='x.com.samsung.da.favorite.showList',
write_fn=lambda p, rep, href=None: (
['favorite', 'hotwater', 'vs', '0'],
{'x.com.samsung.da.favorite.defaultTemperature': p})),
@@ -10,12 +10,18 @@
"automatic_operation": {
"name": "Automatic operation"
},
"battery_charging": {
"name": "Charging"
},
"burner_hot_surface": {
"name": "Burner {number} hot surface"
},
"burner_pan_detected": {
"name": "Burner {number} pan detected"
},
"child_lock": {
"name": "Child lock"
},
"cloud_connected": {
"name": "Cloud connected"
},
@@ -609,6 +615,9 @@
"air_filter_usage_hours": {
"name": "Filter usage hours"
},
"air_quality_standard": {
"name": "Air quality standard"
},
"air_sensing_state": {
"name": "Air sensing state"
},
@@ -621,12 +630,18 @@
"automatic_ventilation_state": {
"name": "Automatic ventilation state"
},
"battery": {
"name": "Battery"
},
"burner_state": {
"name": "Burner {number} state"
},
"clean_level": {
"name": "Clean level"
},
"co2": {
"name": "CO2"
},
"coffee_brew_status": {
"name": "Coffee brew status"
},
@@ -1008,6 +1023,9 @@
"display_light": {
"name": "Display light"
},
"dnd": {
"name": "Do not disturb"
},
"fast_preheat": {
"name": "Fast preheat"
},
@@ -1091,6 +1109,12 @@
}
},
"time": {
"dnd_end": {
"name": "Do not disturb end"
},
"dnd_start": {
"name": "Do not disturb start"
},
"led_night_end": {
"name": "Door LED night end"
},
@@ -10,12 +10,18 @@
"automatic_operation": {
"name": "Automatische werking"
},
"battery_charging": {
"name": "Opladen"
},
"burner_hot_surface": {
"name": "Brander {number} heet oppervlak"
},
"burner_pan_detected": {
"name": "Pan gedetecteerd op brander {number}"
},
"child_lock": {
"name": "Kinderslot"
},
"cloud_connected": {
"name": "Verbonden met cloud"
},
@@ -609,6 +615,9 @@
"air_filter_usage_hours": {
"name": "Filterverbruik (uren)"
},
"air_quality_standard": {
"name": "Luchtkwaliteitsnorm"
},
"air_sensing_state": {
"name": "Status luchtmeting"
},
@@ -621,12 +630,18 @@
"automatic_ventilation_state": {
"name": "Status automatische ventilatie"
},
"battery": {
"name": "Batterij"
},
"burner_state": {
"name": "Status brander {number}"
},
"clean_level": {
"name": "Reinigingsniveau"
},
"co2": {
"name": "CO2"
},
"coffee_brew_status": {
"name": "Koffiezetstatus"
},
@@ -1008,6 +1023,9 @@
"display_light": {
"name": "Displayverlichting"
},
"dnd": {
"name": "Niet storen"
},
"fast_preheat": {
"name": "Snel voorverwarmen"
},
@@ -1091,6 +1109,12 @@
}
},
"time": {
"dnd_end": {
"name": "Einde niet storen"
},
"dnd_start": {
"name": "Start niet storen"
},
"led_night_end": {
"name": "Einde nachtverlichting deur-LED"
},