fix(registry): resolve ARTIK051_KRAC_18K to the airconditioner registry

Room air conditioners on the ARTIK051 board (ARTIK051_KRAC_18K, issue #136)
report no oneUiVersion and carry a '_KRAC_' token in modelNum. The existing
'_RAC_' check can't see it -- the 'K' sits between the underscore and 'RAC' --
and the consumer-prefix fallback only covers washers/dryers/dishwashers, so
these units fell back to 'unknown': 8 of their 19 resources ended up unbound
and the device exposed nothing but a power switch.

Same ARTIK051 board family as the '_TVTL_' air purifier handled just below.
This commit is contained in:
perseus177
2026-07-28 02:28:13 +02:00
parent c19800ac00
commit 75f2be7aaf
@@ -212,6 +212,14 @@ def for_device_by_model(model_num: str, description: str) -> Optional[DeviceRegi
key = 'airconditioner'
# Air purifiers (e.g. ARTIK051_TVTL_18K, issue #56) report no
# oneUiVersion either, and carry the '_TVTL_' board-family token.
# Room air conditioners on the ARTIK051 board (e.g. ARTIK051_KRAC_18K,
# issue #136) report no oneUiVersion and carry a '_KRAC_' token. The '_RAC_'
# check above cannot see it -- the 'K' sits between the underscore and 'RAC' --
# and the consumer-prefix fallback only covers washers/dryers/dishwashers, so
# these units fell back to 'unknown' and exposed nothing but power. Same
# ARTIK051 board family as the '_TVTL_' air purifier below.
if key is None and '_KRAC_' in (model_num or ''):
key = 'airconditioner'
if key is None and '_TVTL_' in (model_num or ''):
key = 'air_purifier'
model_identity = f'{model_num} {description}'.upper()