fix(airconditioner): scale legacy ARTIK051 cumulativePower correctly (#193)

ARTIK051_KRAC_18K-generation boards report /energy/consumption/vs/0's
cumulativePower in centiwatt-hours, not the plain Wh every other AC board
family reports -- confirmed against the reporter's own SmartThings-app
reading (raw 117430000 vs. the app's authoritative 1,174.30 kWh is exactly
a /100000 factor, not the shared wh_to_kwh's /1000 alone). Split
common.ENERGY_METER into generic/legacy variants on the airconditioner
registry, discriminated by the existing is_legacy_board() check, so every
other AC family keeps the unmodified shared capability.
This commit is contained in:
Marc Billow
2026-07-29 13:04:33 +00:00
parent e8df8f7b0c
commit d83733a670
6 changed files with 340 additions and 1 deletions
@@ -7,6 +7,13 @@ this registry includes *common.UNIVERSAL but deliberately NOT common.POWER --
on/off is the climate entity's HVACMode.OFF / TURN_ON/OFF. See common.POWER's
own comment in capabilities/common.py for why it's excluded.
common.ENERGY_METER itself is also excluded from UNIVERSAL here, replaced by
the ENERGY_METER_GENERIC/ENERGY_METER_LEGACY pair -- the legacy ARTIK051 board
generation (issue #193) reports cumulativePower in a different unit than
every other AC family, so this registry needs two mutually-exclusive variants
of that one capability instead of the single shared one every other registry
uses unconditionally.
Reuses dishwasher.DIAGNOSIS for /diagnosis/vs/0.
"""
from ..capabilities import airconditioner, common, dishwasher, ignored
@@ -16,7 +23,9 @@ REGISTRY = DeviceRegistry(
name='airconditioner',
capabilities=_build([
*ignored.IGNORED,
*common.UNIVERSAL,
*[c for c in common.UNIVERSAL if c is not common.ENERGY_METER],
airconditioner.ENERGY_METER_GENERIC,
airconditioner.ENERGY_METER_LEGACY,
dishwasher.DIAGNOSIS,
airconditioner.CLIMATE,
airconditioner.AIR_PURIFY,
@@ -14,10 +14,13 @@ None of these caps may go into the global `ALL`/`CAPABILITIES`: `/mode/vs/0`,
different schema (see capabilities/__init__.py). They live only in the AC
by_type registry.
"""
from dataclasses import replace
from ..capability import Capability
from ..entities import (
BinarySensorDesc, ClimateDesc, NumberDesc, SelectDesc, SensorDesc, SwitchDesc,
)
from . import common
from .common import filter_usage_percent, normalize_temp_unit
from .laundry import option_write
@@ -296,6 +299,44 @@ def is_legacy_board(resources):
return HREF_AIRFLOW in resources and HREF_WIND_STRENGTH not in resources
# This legacy ARTIK051 board generation (issue #193, model AR12NXWXCWKNEU /
# ARTIK051_KRAC_18K) reports /energy/consumption/vs/0's cumulativePower in
# centiwatt-hours -- raw value 100x the plain Wh every other AC board family
# (and common.wh_to_kwh's assumed unit) reports. Confirmed against the
# reporter's own SmartThings-app reading: raw '117430000' vs the app's
# authoritative 1,174.30 kWh is exactly a /100000 factor (i.e. /100 on top of
# wh_to_kwh's own /1000), not wh_to_kwh's plain /1000 alone. No other field in
# ENERGY_METER's entities is present on this board's dump, so only
# 'energy_kwh' needs a replacement value_fn here; the rest pass through
# unchanged in case a future legacy dump ever reports them.
def _legacy_cumulative_power_kwh(v):
n = _int(v)
return round(n / 100000.0, 2) if n is not None else None
ENERGY_METER_LEGACY = Capability(
href=common.ENERGY_METER.href,
poll_tier=common.ENERGY_METER.poll_tier,
match_fn=lambda rep, resources: is_legacy_board(resources),
entities=tuple(
replace(e, value_fn=_legacy_cumulative_power_kwh)
if e.key == 'energy_kwh' else e
for e in common.ENERGY_METER.entities
),
)
# The non-legacy counterpart to ENERGY_METER_LEGACY above -- identical to
# common.ENERGY_METER, just excluding the legacy board generation so the two
# capabilities can share /energy/consumption/vs/0 in this registry without
# the 'multiple caps need a discriminator' build check tripping (common.
# ENERGY_METER itself has no match_fn, since every *other* registry includes
# it unconditionally and alone).
ENERGY_METER_GENERIC = replace(
common.ENERGY_METER,
match_fn=lambda rep, resources: not is_legacy_board(resources),
)
def _has_option_token(prefix):
return lambda rep, resources: (
is_legacy_board(resources) and _option_token(rep, prefix) is not None)
@@ -0,0 +1,231 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/personality/presence/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "",
"x.com.samsung.da.deviceId": "**REDACTED**",
"x.com.samsung.da.value": ""
}
]
}
},
{
"href": "/airflow/vs/0",
"rep": {
"x.com.samsung.da.speedLevel": "0",
"x.com.samsung.da.direction": "All"
}
},
{
"href": "/airflow/0",
"rep": {
"speed": 0,
"direction": "All"
}
},
{
"href": "/alarms/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "ErrorCode_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-29T12:29:36",
"x.com.samsung.da.state": "Deleted"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "FilterAlarm_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-29T12:29:36",
"x.com.samsung.da.state": "Deleted"
}
]
}
},
{
"href": "/temperatures/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Temperature",
"x.com.samsung.da.desired": "23",
"x.com.samsung.da.current": "23",
"x.com.samsung.da.maximum": "30",
"x.com.samsung.da.minimum": "16",
"x.com.samsung.da.unit": "Celsius"
}
]
}
},
{
"href": "/temperature/current/0",
"rep": {
"range": [
16.0,
30.0
],
"units": "C",
"temperature": 23.0
}
},
{
"href": "/temperature/desired/0",
"rep": {
"range": [
16.0,
30.0
],
"units": "C",
"temperature": 23.0
}
},
{
"href": "/diagnosis/vs/0",
"rep": {
"x.com.samsung.da.diagnosisStart": "Ready"
}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.cumulativePower": "117430000",
"x.com.samsung.da.cumulativeDate": "1785337200"
}
},
{
"href": "/energy/consumption/0",
"rep": {}
},
{
"href": "/mode/vs/0",
"rep": {
"x.com.samsung.da.supportedModes": [
"Cool",
"Dry",
"Wind",
"Auto",
"Heat"
],
"x.com.samsung.da.modes": [
"Cool"
],
"x.com.samsung.da.options": [
"Comode_Off",
"Sleep_0",
"OutdoorTemp_85",
"CoolCapa_35",
"WarmCapa_35",
"Spi_Off",
"Autoclean_Off",
"Light_Off",
"Volume_100",
"AirMonitoring_Off",
"AutocleanProgress_0",
"StopAutoClean_Idle",
"FilterTime_1425",
"FilterAlarmTime_500",
"OptionCode_56378",
"ExtendOptionCode_7",
"RacInfo_None",
"UpdateAllow_NotAllowed"
]
}
},
{
"href": "/mode/0",
"rep": {
"supportedModes": [
"Cool",
"Dry",
"Wind",
"Auto",
"Heat"
],
"modes": [
"Cool"
]
}
},
{
"href": "/power/vs/0",
"rep": {
"x.com.samsung.da.power": "On"
}
},
{
"href": "/power/0",
"rep": {
"value": true
}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "ARTIK051_KRAC_18K|10193441|60010123001111110100000000000000",
"x.com.samsung.da.description": "ARTIK051_KRAC_18K",
"x.com.samsung.da.serialNum": "**REDACTED**",
"x.com.samsung.da.otnDUID": "**REDACTED**",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02016A200825",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "17110700,17110600",
"x.com.samsung.da.newVersionAvailable": "0"
}
]
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "+03:00",
"x.com.samsung.supprtedtype": 1
}
},
{
"href": "/configuration/vs/0",
"rep": {
"x.com.samsung.da.region": "0000000000"
}
},
{
"href": "/humidity/0",
"rep": {
"humidity": 0
}
},
{
"href": "/humidity/vs/0",
"rep": {
"x.com.samsung.da.humidity": "0"
}
}
]
}
@@ -0,0 +1,18 @@
{
"state_keys": [
"air_monitoring",
"alarm_code",
"auto_clean_legacy",
"buzzer_volume",
"climate",
"current_temperature_c",
"diagnosis_status",
"display_light",
"energy_kwh",
"filter_time",
"good_sleep",
"humidity",
"outdoor_temperature",
"spi"
]
}
+21
View File
@@ -824,3 +824,24 @@ def test_beep_and_tropical_night_stay_off_legacy_krac_board():
assert 'tropical_night_mode' not in state
assert state['buzzer_volume'] == 100.0
assert state['good_sleep'] == 0.0
def test_legacy_krac_board_energy_kwh_uses_centiwatt_hour_scale():
"""Issue #193: this legacy ARTIK051 board reports cumulativePower in
centiwatt-hours (raw '117430000'), not the plain Wh common.wh_to_kwh
assumes -- confirmed against the reporter's own SmartThings-app reading
of 1,174.30 kWh. ENERGY_METER_LEGACY's /100000 scale must produce that
exact value, not the /1000-only 117430.0 the generic capability would."""
reg, resources = _resolve('airconditioner_artik051_krac_energy')
state = flatten(
discover(resources, reg.capabilities, reg.pattern_capabilities), resources)
assert state['energy_kwh'] == 1174.3
def test_non_legacy_board_energy_kwh_still_uses_plain_wh_scale():
"""The ENERGY_METER_GENERIC/LEGACY split must not change behavior for
every other AC board generation -- same value as plain wh_to_kwh."""
reg, resources = _ac()
state = flatten(
discover(resources, reg.capabilities, reg.pattern_capabilities), resources)
assert state['energy_kwh'] == round(1686632 / 1000.0, 2)
+19
View File
@@ -859,6 +859,25 @@ def test_registry_reproduces_golden_state_keys_for_airconditioner_fac_bora():
)
def test_registry_reproduces_golden_state_keys_for_airconditioner_artik051_krac_energy():
"""AR12NXWXCWKNEU/ARTIK051_KRAC_18K (issue #193) -- same legacy board
generation as the artik051_krac_18k fixture, but this dump has a nonzero
cumulativePower. Locks in state_keys; the actual /100000 scale fix is
asserted separately in test_airconditioner_capabilities.py since golden
only compares key sets, not values."""
from tests.conftest import _load_device
resources = _load_device('airconditioner_artik051_krac_energy')
golden = json.loads(
(GOLDEN / 'airconditioner_artik051_krac_energy.json').read_text()
)
state_keys = _new_state_keys('airconditioner_artik051_krac_energy', resources)
assert set(state_keys) == set(golden['state_keys']), (
f"state_keys mismatch:\n"
f" extra: {sorted(set(state_keys) - set(golden['state_keys']))}\n"
f" missing: {sorted(set(golden['state_keys']) - set(state_keys))}"
)
def test_resources_from_batch_preferred_over_flat():
from tests.conftest import _resources_from_dump
dump = {