fix(airconditioner): scale legacy ARTIK051 cumulativePower correctly (#193)

ARTIK051_KRAC_18K-generation boards report /energy/consumption/vs/0's
cumulativePower in centiwatt-hours, not the plain Wh every other AC board
family reports -- confirmed against the reporter's own SmartThings-app
reading (raw 117430000 vs. the app's authoritative 1,174.30 kWh is exactly
a /100000 factor, not the shared wh_to_kwh's /1000 alone). Split
common.ENERGY_METER into generic/legacy variants on the airconditioner
registry, discriminated by the existing is_legacy_board() check, so every
other AC family keeps the unmodified shared capability.
This commit is contained in:
Marc Billow committed 2026-07-29 13:04:33 +00:00
1 parent e8df8f7b0c
commit d83733a670
6 files changed
+340 -1

No files matched your search

@@ -0,0 +1,231 @@
{
"device0": [
{
"rt": [
"x.com.samsung.devcol",
"oic.wk.col"
],
"if": [
"oic.if.baseline",
"oic.if.ll",
"oic.if.b"
]
},
{
"href": "/personality/presence/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "",
"x.com.samsung.da.deviceId": "**REDACTED**",
"x.com.samsung.da.value": ""
}
]
}
},
{
"href": "/airflow/vs/0",
"rep": {
"x.com.samsung.da.speedLevel": "0",
"x.com.samsung.da.direction": "All"
}
},
{
"href": "/airflow/0",
"rep": {
"speed": 0,
"direction": "All"
}
},
{
"href": "/alarms/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "ErrorCode_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-29T12:29:36",
"x.com.samsung.da.state": "Deleted"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Alarm",
"x.com.samsung.da.alarmType": "Device",
"x.com.samsung.da.code": "FilterAlarm_OFF",
"x.com.samsung.da.triggeredTime": "2026-07-29T12:29:36",
"x.com.samsung.da.state": "Deleted"
}
]
}
},
{
"href": "/temperatures/vs/0",
"rep": {
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Temperature",
"x.com.samsung.da.desired": "23",
"x.com.samsung.da.current": "23",
"x.com.samsung.da.maximum": "30",
"x.com.samsung.da.minimum": "16",
"x.com.samsung.da.unit": "Celsius"
}
]
}
},
{
"href": "/temperature/current/0",
"rep": {
"range": [
16.0,
30.0
],
"units": "C",
"temperature": 23.0
}
},
{
"href": "/temperature/desired/0",
"rep": {
"range": [
16.0,
30.0
],
"units": "C",
"temperature": 23.0
}
},
{
"href": "/diagnosis/vs/0",
"rep": {
"x.com.samsung.da.diagnosisStart": "Ready"
}
},
{
"href": "/energy/consumption/vs/0",
"rep": {
"x.com.samsung.da.cumulativePower": "117430000",
"x.com.samsung.da.cumulativeDate": "1785337200"
}
},
{
"href": "/energy/consumption/0",
"rep": {}
},
{
"href": "/mode/vs/0",
"rep": {
"x.com.samsung.da.supportedModes": [
"Cool",
"Dry",
"Wind",
"Auto",
"Heat"
],
"x.com.samsung.da.modes": [
"Cool"
],
"x.com.samsung.da.options": [
"Comode_Off",
"Sleep_0",
"OutdoorTemp_85",
"CoolCapa_35",
"WarmCapa_35",
"Spi_Off",
"Autoclean_Off",
"Light_Off",
"Volume_100",
"AirMonitoring_Off",
"AutocleanProgress_0",
"StopAutoClean_Idle",
"FilterTime_1425",
"FilterAlarmTime_500",
"OptionCode_56378",
"ExtendOptionCode_7",
"RacInfo_None",
"UpdateAllow_NotAllowed"
]
}
},
{
"href": "/mode/0",
"rep": {
"supportedModes": [
"Cool",
"Dry",
"Wind",
"Auto",
"Heat"
],
"modes": [
"Cool"
]
}
},
{
"href": "/power/vs/0",
"rep": {
"x.com.samsung.da.power": "On"
}
},
{
"href": "/power/0",
"rep": {
"value": true
}
},
{
"href": "/information/vs/0",
"rep": {
"x.com.samsung.da.modelNum": "ARTIK051_KRAC_18K|10193441|60010123001111110100000000000000",
"x.com.samsung.da.description": "ARTIK051_KRAC_18K",
"x.com.samsung.da.serialNum": "**REDACTED**",
"x.com.samsung.da.otnDUID": "**REDACTED**",
"x.com.samsung.da.items": [
{
"x.com.samsung.da.id": "0",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Software",
"x.com.samsung.da.number": "02016A200825",
"x.com.samsung.da.newVersionAvailable": "0"
},
{
"x.com.samsung.da.id": "1",
"x.com.samsung.da.description": "Version",
"x.com.samsung.da.type": "Firmware",
"x.com.samsung.da.number": "17110700,17110600",
"x.com.samsung.da.newVersionAvailable": "0"
}
]
}
},
{
"href": "/file/information/vs/0",
"rep": {
"x.com.samsung.timeoffset": "+03:00",
"x.com.samsung.supprtedtype": 1
}
},
{
"href": "/configuration/vs/0",
"rep": {
"x.com.samsung.da.region": "0000000000"
}
},
{
"href": "/humidity/0",
"rep": {
"humidity": 0
}
},
{
"href": "/humidity/vs/0",
"rep": {
"x.com.samsung.da.humidity": "0"
}
}
]
}
@@ -0,0 +1,18 @@
{
"state_keys": [
"air_monitoring",
"alarm_code",
"auto_clean_legacy",
"buzzer_volume",
"climate",
"current_temperature_c",
"diagnosis_status",
"display_light",
"energy_kwh",
"filter_time",
"good_sleep",
"humidity",
"outdoor_temperature",
"spi"
]
}
+21
View File
@@ -824,3 +824,24 @@ def test_beep_and_tropical_night_stay_off_legacy_krac_board():
assert 'tropical_night_mode' not in state
assert state['buzzer_volume'] == 100.0
assert state['good_sleep'] == 0.0
def test_legacy_krac_board_energy_kwh_uses_centiwatt_hour_scale():
"""Issue #193: this legacy ARTIK051 board reports cumulativePower in
centiwatt-hours (raw '117430000'), not the plain Wh common.wh_to_kwh
assumes -- confirmed against the reporter's own SmartThings-app reading
of 1,174.30 kWh. ENERGY_METER_LEGACY's /100000 scale must produce that
exact value, not the /1000-only 117430.0 the generic capability would."""
reg, resources = _resolve('airconditioner_artik051_krac_energy')
state = flatten(
discover(resources, reg.capabilities, reg.pattern_capabilities), resources)
assert state['energy_kwh'] == 1174.3
def test_non_legacy_board_energy_kwh_still_uses_plain_wh_scale():
"""The ENERGY_METER_GENERIC/LEGACY split must not change behavior for
every other AC board generation -- same value as plain wh_to_kwh."""
reg, resources = _ac()
state = flatten(
discover(resources, reg.capabilities, reg.pattern_capabilities), resources)
assert state['energy_kwh'] == round(1686632 / 1000.0, 2)
+19
View File
@@ -859,6 +859,25 @@ def test_registry_reproduces_golden_state_keys_for_airconditioner_fac_bora():
)
def test_registry_reproduces_golden_state_keys_for_airconditioner_artik051_krac_energy():
"""AR12NXWXCWKNEU/ARTIK051_KRAC_18K (issue #193) -- same legacy board
generation as the artik051_krac_18k fixture, but this dump has a nonzero
cumulativePower. Locks in state_keys; the actual /100000 scale fix is
asserted separately in test_airconditioner_capabilities.py since golden
only compares key sets, not values."""
from tests.conftest import _load_device
resources = _load_device('airconditioner_artik051_krac_energy')
golden = json.loads(
(GOLDEN / 'airconditioner_artik051_krac_energy.json').read_text()
)
state_keys = _new_state_keys('airconditioner_artik051_krac_energy', resources)
assert set(state_keys) == set(golden['state_keys']), (
f"state_keys mismatch:\n"
f" extra: {sorted(set(state_keys) - set(golden['state_keys']))}\n"
f" missing: {sorted(set(golden['state_keys']) - set(state_keys))}"
)
def test_resources_from_batch_preferred_over_flat():
from tests.conftest import _resources_from_dump