fix(airconditioner): scale legacy ARTIK051 cumulativePower correctly (#193)

ARTIK051_KRAC_18K-generation boards report /energy/consumption/vs/0's
cumulativePower in centiwatt-hours, not the plain Wh every other AC board
family reports -- confirmed against the reporter's own SmartThings-app
reading (raw 117430000 vs. the app's authoritative 1,174.30 kWh is exactly
a /100000 factor, not the shared wh_to_kwh's /1000 alone). Split
common.ENERGY_METER into generic/legacy variants on the airconditioner
registry, discriminated by the existing is_legacy_board() check, so every
other AC family keeps the unmodified shared capability.
This commit is contained in:
Marc Billow committed 2026-07-29 13:04:33 +00:00
1 parent e8df8f7b0c
commit d83733a670
6 files changed
+340 -1

No files matched your search

@@ -0,0 +1,18 @@
{
"state_keys": [
"air_monitoring",
"alarm_code",
"auto_clean_legacy",
"buzzer_volume",
"climate",
"current_temperature_c",
"diagnosis_status",
"display_light",
"energy_kwh",
"filter_time",
"good_sleep",
"humidity",
"outdoor_temperature",
"spi"
]
}