Type air_monitor's particulates and migrate the recorded statistics

Adding a unit to a sensor that recorded long-term statistics without one
is not cosmetic: Home Assistant raises a units_changed repair and then
*suppresses statistics generation* for that entity until a human resolves
it (sensor/recorder.py's compile path hits `continue`). Shipping the PM
device classes on their own would therefore have silently frozen the very
history the labels were meant to describe.

A v2 -> v3 config-entry migration relabels the statistics metadata first.
It rewrites only the metadata row, never the recorded values -- these
readings were always µg/m³ and only the label was missing, so nothing
needs converting, which is why this uses async_update_statistics_metadata
and not change_statistics_unit. It reads entity_ids back off the entity
registry rather than rebuilding them from descriptor keys, since a renamed
entity's statistic_id no longer follows from its key, and it is scoped by
device family: range_hood and airconditioner still declare no unit for
their identically-named sensors, so relabelling theirs would create the
exact mismatch this exists to prevent.

With the migration in place there is no longer a reason to hold the labels
back on air_monitor, so it takes them too. That board is one of the two
whose fixtures pin the grade bands the mapping rests on -- typing the
purifier and not the monitor was an inconsistency, not caution. It still
declines the shared state_class column, unchanged.

Recorder coupling is guarded: after_dependencies pulls it in when
configured, the import is local to the migration, and a setup without it
is a no-op. Freshly created entries mint v3 directly, having no history to
relabel.

Tested at both levels. The unit-level tests patch the recorder and assert
which entities are relabelled with which arguments, covering the renamed
entity, subdevice-prefixed and instanced keys, the near-miss keys
(dustbag_/dustbin_), the skipped families and the recorder-absent path.
Because a mock can only prove the call is made, not that it does what the
migration needs, a second suite drives a real in-memory recorder end to
end: statistics seeded unitless, migration run, metadata confirmed to read
µg/m³ / concentration, recorded means confirmed byte-identical, and the
units_changed issue confirmed present before and absent after.
This commit is contained in:
Marc Billow committed 2026-08-15 01:01:49 +00:00
1 parent 21af5708cb
commit eeece4906c
8 files changed
+469 -30

No files matched your search

+89 -2
View File
@@ -3,8 +3,12 @@
from __future__ import annotations
import logging
import re
from homeassistant.config_entries import ConfigEntry
from homeassistant.const import (
CONCENTRATION_MICROGRAMS_PER_CUBIC_METER as PARTICULATE_UNIT,
)
from homeassistant.const import EVENT_HOMEASSISTANT_STOP
from homeassistant.core import Event, HomeAssistant, callback
from homeassistant.exceptions import ConfigEntryNotReady
@@ -12,7 +16,7 @@ from homeassistant.helpers import device_registry as dr
from homeassistant.helpers import entity_registry as er
from homeassistant.helpers.typing import ConfigType
from .const import CONF_HOST, CONF_PORT, CONF_SERIAL, DOMAIN, PLATFORMS
from .const import CONF_DEVICE_TYPE, CONF_HOST, CONF_PORT, CONF_SERIAL, DOMAIN, PLATFORMS
from .coordinator import LocalThingsCoordinator
from .registry.identity import resolve_serial
from .services import async_setup_services
@@ -125,6 +129,81 @@ def _repair_placeholder_keys(hass: HomeAssistant, entry: ConfigEntry, serial: st
)
# Registries whose Dust/FineDust/SuperFineDust sensors gained pm10/pm25/pm1
# and a unit in the release that introduced entry version 3. Deliberately
# not every family reading /sensors/vs/0: range_hood and airconditioner
# still declare no unit for their identically-named sensors, and relabelling
# their statistics to µg/m³ would assert a unit those entities don't report
# -- creating the very mismatch this migration exists to prevent.
_PARTICULATE_TYPED_IN_V3 = frozenset({"air_purifier", "air_monitor"})
# unique_id is f"{DOMAIN}_{serial}_{state_key}"; state_key is the descriptor
# key, optionally carrying a subdevice prefix and a trailing instance number
# (registry/adapter._key). Matching the tail rather than rebuilding the whole
# id keeps this working for a renamed entity, whose entity_id -- and so its
# statistic_id -- no longer follows from the key at all.
_PARTICULATE_KEY_RE = re.compile(r"_(?:super_fine_dust|fine_dust|dust)\d*$")
@callback
def _relabel_particulate_statistics(hass: HomeAssistant, entry: ConfigEntry) -> None:
"""Point existing particulate statistics at the unit they always were.
These sensors recorded long-term statistics with no unit, and the
release carrying this migration gives them µg/m³. Home Assistant treats
that as a unit change it can't convert and *suppresses statistics
generation entirely* for the entity until someone resolves the repair
(sensor.recorder._update_issues -> UNITS_CHANGED_ISSUE, and the matching
`continue` in its compile path). Silently freezing the history we just
finished labelling is the worst of both outcomes, so the metadata is
corrected up front instead.
Only the metadata row is rewritten, never the recorded values. The
readings were always µg/m³ concentrations (issue #325); what was missing
was the label, so there is nothing to convert and no way for this to
distort history. That is also why it uses
`async_update_statistics_metadata` and not `change_statistics_unit`,
which would scale every stored value.
A no-op when the recorder isn't loaded, when this device family isn't
one that gained the unit, or when the device never recorded any
statistics -- the underlying UPDATE simply matches no rows.
"""
if entry.data.get(CONF_DEVICE_TYPE) not in _PARTICULATE_TYPED_IN_V3:
return
if "recorder" not in hass.config.components:
# after_dependencies pulls the recorder in when it's configured at
# all; a setup running without it has no statistics to relabel.
_LOGGER.debug("recorder not loaded, skipping statistics relabel")
return
from homeassistant.components.recorder.statistics import (
STATISTIC_UNIT_TO_UNIT_CONVERTER,
async_update_statistics_metadata,
)
# µg/m³ has a converter (MassVolumeConcentrationConverter), so its class
# is 'concentration', not None. Read rather than hardcoded: passing a
# class that disagrees with HA's own table raises, and passing none at
# all is deprecated and stops working in HA Core 2026.11.
converter = STATISTIC_UNIT_TO_UNIT_CONVERTER.get(PARTICULATE_UNIT)
unit_class = converter.UNIT_CLASS if converter is not None else None
ent_reg = er.async_get(hass)
for registry_entry in er.async_entries_for_config_entry(ent_reg, entry.entry_id):
if registry_entry.domain != "sensor":
continue
if not _PARTICULATE_KEY_RE.search(registry_entry.unique_id):
continue
_LOGGER.debug("relabelling statistics unit for %s", registry_entry.entity_id)
async_update_statistics_metadata(
hass,
registry_entry.entity_id,
new_unit_class=unit_class,
new_unit_of_measurement=PARTICULATE_UNIT,
)
async def async_migrate_entry(hass: HomeAssistant, entry: ConfigEntry) -> bool:
"""Migrate an entry to the current version.
@@ -132,8 +211,11 @@ async def async_migrate_entry(hass: HomeAssistant, entry: ConfigEntry) -> bool:
can key its registry entries before the first poll (issue #236), and
repairs whatever the old placeholder-keyed registration already
orphaned.
v2 -> v3 relabels the recorded statistics for the particulate sensors,
which gained a device_class/unit in the same release (issue #325).
"""
if entry.version > 2:
if entry.version > 3:
return False # downgrade: this release doesn't know the newer shape
if entry.version == 1:
@@ -147,6 +229,11 @@ async def async_migrate_entry(hass: HomeAssistant, entry: ConfigEntry) -> bool:
_repair_placeholder_keys(hass, entry, serial)
_LOGGER.debug("migrated entry %s to version 2 (serial=%s)", entry.entry_id, serial)
if entry.version == 2:
_relabel_particulate_statistics(hass, entry)
hass.config_entries.async_update_entry(entry, version=3)
_LOGGER.debug("migrated entry %s to version 3", entry.entry_id)
return True
+4 -1
View File
@@ -793,7 +793,10 @@ def _probe_and_validate(
class LocalThingsConfigFlow(config_entries.ConfigFlow, domain=DOMAIN):
VERSION = 2
# v3 relabels the particulate sensors' recorded statistics; a freshly
# created entry has none to relabel, so it starts at the migrated
# version rather than walking through v2 (see async_migrate_entry).
VERSION = 3
def __init__(self) -> None:
self._host: str = ""
@@ -1,6 +1,7 @@
{
"domain": "localthings",
"name": "LocalThings",
"after_dependencies": ["recorder"],
"codeowners": ["@mbillow"],
"config_flow": true,
"dependencies": [],
@@ -18,15 +18,17 @@ aggregate. This board's own readings are load-bearing evidence for the
PM mapping, though: 23 grading one step above the floor as FineDust is
what rules out a PM10-width band for that field.
Dust/FineDust/SuperFineDust nevertheless stay without an HA
`device_class`/`unit` here, which is now a migration call rather than an
evidence gap. The mapping confirmed for the purifier family (issue #325,
Dust=PM10 / FineDust=PM2.5 / SuperFineDust=PM1 in μg/m³) rests on
device-side grading that this board shares, so it would carry over. But
these five sensors have recorded unitless long-term statistics since
issue #210, and stamping a unit onto an existing statistic is what raises
Home Assistant's "units changed" repair -- a deliberate follow-up, not
something to fold into the purifier's first typed release.
Dust/FineDust/SuperFineDust carry the same HA `device_class`/`unit` as the
purifier family (issue #325, Dust=PM10 / FineDust=PM2.5 /
SuperFineDust=PM1 in μg/m³). The mapping rests on device-side grading this
board shares rather than on anything purifier-specific, so typing one
family and not the other would have been an inconsistency, not caution.
These sensors have recorded *unitless* long-term statistics since issue
#210, though, and Home Assistant suppresses statistics generation outright
for an entity whose unit no longer matches its recorded metadata -- so
stamping a unit on would have silently stopped the history it was meant to
label. __init__.py's v2->v3 entry migration relabels that metadata first.
"""
from datetime import time as dt_time
@@ -36,14 +38,15 @@ from ..entities import BinarySensorDesc, SensorDesc, SwitchDesc, TimeDesc
from .air_purifier import _AIR_QUALITY_SENSORS
from .common import int_or_none, sensor_item_value
# Extra columns (state_class, device_class, unit) are deliberately discarded
# here: air_purifier leaves Odor/CleanLevel unstamped because they read as
# device_class/unit are taken from the shared rows; state_class deliberately
# is not. air_purifier leaves Odor/CleanLevel unstamped because they read as
# graded indices on that family, while this board has stamped all five as
# `measurement` since it was added (issue #210). Consuming state_class would
# silently drop long-term statistics for two sensors on shipped devices, and
# the pm10/pm25/pm1 labels are held back pending the statistics migration
# the module docstring describes. The shared rows supply only the
# key/icon/type here.
# `measurement` since it was added (issue #210) -- consuming that column
# would silently drop long-term statistics for two sensors on shipped
# devices. The pm10/pm25/pm1 labels carry over cleanly, though: they rest on
# device-side grading this board shares (see the module docstring), and
# __init__.py's v2->v3 entry migration relabels the unitless statistics
# these five have been recording so the new unit doesn't suppress them.
SENSORS = Capability(
href="/sensors/vs/0",
poll_tier="warm",
@@ -54,9 +57,11 @@ SENSORS = Capability(
field="x.com.samsung.da.items",
icon=icon,
state_class="measurement",
device_class=device_class,
unit=unit,
value_fn=lambda items, t=sensor_type: sensor_item_value(items, t),
)
for key, icon, sensor_type, *_ in _AIR_QUALITY_SENSORS
for key, icon, sensor_type, _state_class, device_class, unit in _AIR_QUALITY_SENSORS
),
SensorDesc(