Merge pull request #139 from mbillow/claude/air-purifier-fan-controls-ananzq
Add real fan-speed control for ARTIK051_TVTL air purifiers (issue #56)
This commit is contained in:
6 files changed
+287
-23
No files matched your search
@@ -1,10 +1,15 @@
|
||||
"""Fan platform for Samsung range hoods and air purifiers.
|
||||
|
||||
Two FanDesc-bound hrefs exist, one per family, dispatched by href in
|
||||
async_setup_entry below since they need different HA fan semantics: the
|
||||
range hood's fan speed is an ordered set of numeric levels (SET_SPEED), while
|
||||
the newer air-purifier board family's modes (Smart/Max/Mid/WindFree/Sleep,
|
||||
issue #130) are named behaviors with no linear order (PRESET_MODE)."""
|
||||
Three FanDesc-bound hrefs exist, dispatched by href in async_setup_entry
|
||||
below since each needs different HA fan semantics: the range hood's fan
|
||||
speed and the older ARTIK051_TVTL air-purifier family's Auto/Sleep/Low/
|
||||
Medium/High (issue #56) are both an ordered set of numeric levels
|
||||
(SET_SPEED) -- the latter confirmed monotonic in capabilities/
|
||||
air_purifier.py's module docstring, with no named-mode list to preserve
|
||||
since this board never self-reports one. The newer TP1X air-purifier
|
||||
family's modes (Smart/Max/Mid/WindFree/Sleep, issue #130) are named
|
||||
behaviors with no linear order (PRESET_MODE), reported directly by that
|
||||
board's own supportedModes."""
|
||||
|
||||
from __future__ import annotations
|
||||
|
||||
@@ -22,6 +27,7 @@ from homeassistant.util.percentage import (
|
||||
from .const import DOMAIN
|
||||
from .coordinator import LocalThingsCoordinator
|
||||
from .entity import LocalThingsEntity, _is_included
|
||||
from .registry.capabilities.air_purifier import HREF_AIRFLOW
|
||||
from .registry.capabilities.air_purifier import HREF_MODE as AIR_PURIFIER_FAN_HREF
|
||||
from .registry.entities import FanDesc
|
||||
|
||||
@@ -48,6 +54,8 @@ async def async_setup_entry(
|
||||
continue
|
||||
if bound.href == AIR_PURIFIER_FAN_HREF:
|
||||
entities.append(LocalThingsAirPurifierFan(coordinator, bound))
|
||||
elif bound.href == HREF_AIRFLOW:
|
||||
entities.append(LocalThingsAirflowFan(coordinator, bound))
|
||||
else:
|
||||
entities.append(LocalThingsRangeHoodFan(coordinator, bound))
|
||||
async_add_entities(entities)
|
||||
@@ -214,3 +222,87 @@ class LocalThingsAirPurifierFan(LocalThingsEntity, FanEntity):
|
||||
"%s: %r is not a valid preset mode (supported: %s)",
|
||||
self.entity_id, preset_mode, self.preset_modes,
|
||||
)
|
||||
|
||||
|
||||
_AIRFLOW_SPEED_FIELD = 'speed'
|
||||
# Raw `speed` codes, low-to-high -- confirmed monotonic (Auto=0, Sleep=1,
|
||||
# Low=2, Medium=3, High=4) via air_purifier.py's module docstring. Ordered
|
||||
# as plain strings, same as _all_speed_codes above, so
|
||||
# ordered_list_item_to_percentage/percentage_to_ordered_list_item can treat
|
||||
# it exactly like the range hood's numeric levels -- no named-preset table
|
||||
# needed since this board never reports mode names to hang one off of.
|
||||
_AIRFLOW_SPEED_CODES = ('0', '1', '2', '3', '4')
|
||||
|
||||
|
||||
class LocalThingsAirflowFan(LocalThingsEntity, FanEntity):
|
||||
"""ARTIK051_TVTL-class air purifier fan (issue #56): an ordered numeric
|
||||
speed range, same SET_SPEED shape as LocalThingsRangeHoodFan above."""
|
||||
|
||||
_enable_turn_on_off_backwards_compatibility = False
|
||||
_attr_supported_features = (
|
||||
FanEntityFeature.SET_SPEED
|
||||
| FanEntityFeature.TURN_ON
|
||||
| FanEntityFeature.TURN_OFF
|
||||
)
|
||||
|
||||
def __init__(self, coordinator: LocalThingsCoordinator, bound) -> None:
|
||||
super().__init__(coordinator, bound)
|
||||
self._attr_name = None
|
||||
|
||||
def _rep(self, href: str) -> dict:
|
||||
return self.coordinator.resource(href) or {}
|
||||
|
||||
def _power_payload(self, enabled: bool) -> tuple[str, bool, str]:
|
||||
"""Prefer /power/0 like LocalThingsRangeHoodFan above, NOT
|
||||
LocalThingsAirPurifierFan's vs/0-first order -- that order is only
|
||||
harmless for the TP1X board because it never reports /power/0 at
|
||||
all. This family's dumps carry both hrefs, and common.POWER_GENERIC
|
||||
(the power_switch entity) is unconditionally bound to /power/0
|
||||
whenever it's present, so writing here to /power/vs/0 first would
|
||||
leave power_switch and this fan reading/writing two different
|
||||
resources -- disagreeing until the next poll refreshes the other
|
||||
one (the same optimistic-apply lag coordinator.py's own comments
|
||||
warn about)."""
|
||||
resources = self.coordinator.last_resources
|
||||
target = POWER_HREF if POWER_HREF in resources else POWER_VS_HREF
|
||||
return 'power', enabled, target
|
||||
|
||||
@property
|
||||
def is_on(self) -> bool:
|
||||
power = self._rep(POWER_HREF)
|
||||
if 'value' in power:
|
||||
return bool(power.get('value'))
|
||||
return str(self._rep(POWER_VS_HREF).get('x.com.samsung.da.power', '')).lower() == 'on'
|
||||
|
||||
@property
|
||||
def speed_count(self) -> int:
|
||||
return len(_AIRFLOW_SPEED_CODES)
|
||||
|
||||
@property
|
||||
def percentage(self) -> int | None:
|
||||
if not self.is_on:
|
||||
return 0
|
||||
current = str(self._rep(self._bound.href).get(_AIRFLOW_SPEED_FIELD, ''))
|
||||
if current not in _AIRFLOW_SPEED_CODES:
|
||||
return None
|
||||
return ordered_list_item_to_percentage(_AIRFLOW_SPEED_CODES, current)
|
||||
|
||||
async def async_turn_on(
|
||||
self, percentage: int | None = None, preset_mode: str | None = None,
|
||||
**kwargs,
|
||||
) -> None:
|
||||
await self.coordinator.async_send_command(self._bound, self._power_payload(True))
|
||||
if percentage is not None:
|
||||
await self.async_set_percentage(percentage)
|
||||
|
||||
async def async_turn_off(self, **kwargs) -> None:
|
||||
await self.coordinator.async_send_command(self._bound, self._power_payload(False))
|
||||
|
||||
async def async_set_percentage(self, percentage: int) -> None:
|
||||
if percentage <= 0:
|
||||
await self.async_turn_off()
|
||||
return
|
||||
if not self.is_on:
|
||||
await self.coordinator.async_send_command(self._bound, self._power_payload(True))
|
||||
code = percentage_to_ordered_list_item(_AIRFLOW_SPEED_CODES, percentage)
|
||||
await self.coordinator.async_send_command(self._bound, ('speed', int(code)))
|
||||
@@ -39,14 +39,23 @@ set to Auto/Sleep/Low/Medium/High):
|
||||
automatic side effect of sleep mode, e.g. a
|
||||
display-dimming level, but that's still a guess).
|
||||
|
||||
/airflow/0 and /airflow/vs/0's `speed` still isn't modeled as a real
|
||||
fan-speed control: across the same five dumps it read 0 for both Auto *and*
|
||||
High, and 3 for Low/Medium *and* Sleep -- not a monotonic mapping to any
|
||||
selectable level, and the dumps were all captured within about three minutes
|
||||
of each other (only one poll cycle apart at this integration's 30s summary
|
||||
interval), so the values may not have settled after each change before the
|
||||
diagnostics snapshot was taken. Exposed read-only pending a confirmed,
|
||||
stable capture -- see the issue #56 discussion for what's needed.
|
||||
/airflow/0's `speed` is now a real fan-speed control (issue #56 follow-up).
|
||||
The first round of five dumps above wasn't conclusive -- it read 0 for both
|
||||
Auto *and* High, and 3 for Low/Medium *and* Sleep, likely because all five
|
||||
were captured within about a minute of each other, faster than this
|
||||
integration's own ~30s poll cycle could settle each change. A second round,
|
||||
captured 60-90s apart per setting on two independent units, confirmed a
|
||||
clean monotonic mapping instead: Auto=0, Sleep=1, Low=2, Medium=3, High=4.
|
||||
AIRFLOW_GENERIC below builds an ordered-speed fan off that confirmed 0-4
|
||||
range -- same SET_SPEED shape as range_hood.py's fan, mapping HA's
|
||||
percentage steps straight onto the raw code, no named-preset table needed
|
||||
(unlike the TP1X family's FAN, which exposes real named modes because its
|
||||
board actually reports a supportedModes list to hang names off of).
|
||||
|
||||
/airflow/vs/0's vendor `speedLevel` is NOT used for the same purpose -- it
|
||||
was unreliable on both units in that second round (Low/Medium collided on
|
||||
one unit, stuck at 0 throughout on the other), so AIRFLOW_VS_FALLBACK below
|
||||
stays a plain read-only diagnostic even after this change.
|
||||
"""
|
||||
from ..capability import Capability
|
||||
from ..entities import (
|
||||
@@ -64,6 +73,7 @@ from .laundry import bool_option_exists, bool_option_value, option_value, option
|
||||
# Both board generations share the /mode/vs/0 href, so FAN and MODE below
|
||||
# are mutually exclusive via this presence check rather than colliding.
|
||||
HREF_MODE = '/mode/vs/0'
|
||||
HREF_AIRFLOW = '/airflow/0'
|
||||
|
||||
|
||||
def _has_top_level_modes(rep, resources):
|
||||
@@ -126,21 +136,52 @@ DEVICE_ACTIVE = Capability(
|
||||
),
|
||||
)
|
||||
|
||||
# OCF-native / vendor pair for fan speed+direction -- see module docstring for
|
||||
# why these are read-only for now.
|
||||
def _airflow_fan_write(payload, rep, href=None):
|
||||
kind, value, *args = payload
|
||||
if kind == 'power':
|
||||
power_href = args[0] if args else '/power/vs/0'
|
||||
if power_href == '/power/0':
|
||||
return ['power', '0'], {'value': bool(value)}
|
||||
return (['power', 'vs', '0'],
|
||||
{'x.com.samsung.da.power': 'On' if value else 'Off'})
|
||||
if kind == 'speed':
|
||||
return ['airflow', '0'], {'speed': int(value)}
|
||||
return None
|
||||
|
||||
|
||||
# Confirmed via issue #56's second, properly-spaced round of diagnostics
|
||||
# (two independent units, 60-90s apart per setting): /airflow/0's `speed` is
|
||||
# a clean, monotonic 0-4 code across Auto/Sleep/Low/Medium/High, so it now
|
||||
# backs a real ordered-speed fan (fan.py's LocalThingsAirflowFan, same
|
||||
# SET_SPEED shape as the range hood's) instead of a read-only sensor --
|
||||
# no named-preset table needed, since HA's percentage steps map onto the
|
||||
# raw 0-4 code directly, the same way the range hood's numeric levels do.
|
||||
# `direction` stays a plain diagnostic: every dump seen (both rounds, both
|
||||
# units) reads 'Off' for it regardless of fan setting, so there's nothing
|
||||
# confirmed to control there yet.
|
||||
#
|
||||
# Keyed 'airflow_fan', not 'fan' -- FAN below (bound to the shared
|
||||
# /mode/vs/0 href) also uses 'fan', and BoundEntity's unique_id is built
|
||||
# from key alone (entity.py's _key), not href. FAN and AIRFLOW_GENERIC are
|
||||
# only *empirically* mutually exclusive (every dump seen has one board
|
||||
# generation's shape or the other, never both), not architecturally
|
||||
# enforced the way same-href caps are by _build()'s match_fn check -- a
|
||||
# same key would collide if a future board ever reported both.
|
||||
AIRFLOW_GENERIC = Capability(
|
||||
href='/airflow/0',
|
||||
href=HREF_AIRFLOW,
|
||||
poll_tier='warm',
|
||||
entities=(
|
||||
SensorDesc(key='fan_speed_level', field='speed',
|
||||
icon='mdi:fan',
|
||||
state_class='measurement', entity_category='diagnostic'),
|
||||
FanDesc(key='airflow_fan', field='speed', write_fn=_airflow_fan_write),
|
||||
SensorDesc(key='fan_direction', field='direction',
|
||||
icon='mdi:rotate-3d-variant',
|
||||
entity_category='diagnostic'),
|
||||
),
|
||||
)
|
||||
|
||||
# Left exactly as a read-only fallback -- speedLevel is NOT the same
|
||||
# confirmed-reliable field as /airflow/0's speed above (see module
|
||||
# docstring): it collided Low/Medium on one unit and stuck at 0 throughout
|
||||
# on the other in the same properly-spaced round.
|
||||
AIRFLOW_VS_FALLBACK = Capability(
|
||||
href='/airflow/vs/0',
|
||||
match_fn=lambda rep, resources: '/airflow/0' not in resources,
|
||||
|
||||
+1
-1
@@ -1,5 +1,6 @@
|
||||
{
|
||||
"state_keys": [
|
||||
"airflow_fan",
|
||||
"alarm_code",
|
||||
"clean_level",
|
||||
"device_active",
|
||||
@@ -11,7 +12,6 @@
|
||||
"energy_saved_kwh",
|
||||
"energy_this_month_kwh",
|
||||
"fan_direction",
|
||||
"fan_speed_level",
|
||||
"filter_progress",
|
||||
"fine_dust",
|
||||
"odor",
|
||||
|
||||
@@ -0,0 +1,105 @@
|
||||
"""HA fan-entity mapping tests for the ARTIK051_TVTL air purifier (issue #56)."""
|
||||
|
||||
from custom_components.localthings.fan import LocalThingsAirflowFan
|
||||
from custom_components.localthings.registry.by_type import air_purifier
|
||||
from custom_components.localthings.registry.capabilities.air_purifier import HREF_AIRFLOW
|
||||
from custom_components.localthings.registry.discovery import discover
|
||||
from custom_components.localthings.registry.entities import FanDesc
|
||||
from tests.conftest import _load_device
|
||||
|
||||
|
||||
class _FakeCoordinator:
|
||||
device_serial = 'TEST-AIRFLOW-SERIAL'
|
||||
device_info = {}
|
||||
data = {}
|
||||
|
||||
def __init__(self, resources):
|
||||
self.last_resources = resources
|
||||
self.commands = []
|
||||
|
||||
def resource(self, href):
|
||||
return self.last_resources.get(href, {})
|
||||
|
||||
async def async_send_command(self, bound, payload):
|
||||
self.commands.append((bound, payload))
|
||||
|
||||
|
||||
def _entity(resources, coordinator=None):
|
||||
bound = discover(
|
||||
resources,
|
||||
air_purifier.REGISTRY.capabilities,
|
||||
air_purifier.REGISTRY.pattern_capabilities,
|
||||
)
|
||||
fan_bound = next(
|
||||
item for item in bound
|
||||
if isinstance(item.desc, FanDesc) and item.href == HREF_AIRFLOW
|
||||
)
|
||||
return LocalThingsAirflowFan(
|
||||
coordinator or _FakeCoordinator(resources), fan_bound,
|
||||
)
|
||||
|
||||
|
||||
def test_power_off_maps_to_zero_percent_and_five_retained_speeds():
|
||||
entity = _entity(_load_device('air_purifier'))
|
||||
assert entity.is_on is False
|
||||
assert entity.speed_count == 5
|
||||
assert entity.percentage == 0
|
||||
|
||||
|
||||
def test_active_codes_map_to_ordered_percentages():
|
||||
"""Confirmed via issue #56's second, properly-spaced diagnostics round:
|
||||
/airflow/0's speed is a clean 0-4 code across Auto/Sleep/Low/Medium/High."""
|
||||
resources = _load_device('air_purifier')
|
||||
resources['/power/0']['value'] = True
|
||||
|
||||
for code, expected_percentage in ((0, 20), (1, 40), (2, 60), (3, 80), (4, 100)):
|
||||
resources['/airflow/0']['speed'] = code
|
||||
assert _entity(resources).percentage == expected_percentage
|
||||
|
||||
|
||||
async def test_power_write_prefers_standard_resource_when_both_exist():
|
||||
"""Both /power/0 and /power/vs/0 are present on this family's dumps --
|
||||
/power/0 must win, matching common.POWER_GENERIC's own preference (the
|
||||
power_switch entity is unconditionally bound to /power/0 whenever it's
|
||||
present, so writing here to /power/vs/0 first would leave the two
|
||||
entities disagreeing until the next poll)."""
|
||||
resources = _load_device('air_purifier')
|
||||
coordinator = _FakeCoordinator(resources)
|
||||
entity = _entity(resources, coordinator)
|
||||
|
||||
await entity.async_turn_on()
|
||||
|
||||
assert coordinator.commands[-1][1] == ('power', True, '/power/0')
|
||||
|
||||
|
||||
async def test_power_write_falls_back_to_vendor_resource():
|
||||
resources = _load_device('air_purifier')
|
||||
resources.pop('/power/0')
|
||||
coordinator = _FakeCoordinator(resources)
|
||||
entity = _entity(resources, coordinator)
|
||||
|
||||
await entity.async_turn_off()
|
||||
|
||||
assert coordinator.commands[-1][1] == ('power', False, '/power/vs/0')
|
||||
|
||||
|
||||
async def test_set_percentage_writes_raw_speed_code():
|
||||
resources = _load_device('air_purifier')
|
||||
resources['/power/0']['value'] = True
|
||||
coordinator = _FakeCoordinator(resources)
|
||||
entity = _entity(resources, coordinator)
|
||||
|
||||
await entity.async_set_percentage(60)
|
||||
|
||||
assert coordinator.commands[-1][1] == ('speed', 2)
|
||||
|
||||
|
||||
async def test_set_percentage_zero_turns_off():
|
||||
resources = _load_device('air_purifier')
|
||||
resources['/power/0']['value'] = True
|
||||
coordinator = _FakeCoordinator(resources)
|
||||
entity = _entity(resources, coordinator)
|
||||
|
||||
await entity.async_set_percentage(0)
|
||||
|
||||
assert coordinator.commands[-1][1] == ('power', False, '/power/0')
|
||||
@@ -41,7 +41,7 @@ def test_expected_entities_present():
|
||||
for key in (
|
||||
'power_switch', 'alarm_code', 'dust', 'fine_dust', 'super_fine_dust',
|
||||
'odor', 'clean_level', 'filter_progress', 'device_active',
|
||||
'diagnosis_status', 'fan_speed_level', 'fan_direction',
|
||||
'diagnosis_status', 'airflow_fan', 'fan_direction',
|
||||
'display_light', 'operating_mode',
|
||||
):
|
||||
assert key in state, key
|
||||
@@ -114,3 +114,27 @@ def test_airflow_vs_fallback_only_binds_without_generic():
|
||||
{}, {'/airflow/0': {'speed': 0, 'direction': 'Off'}},
|
||||
) is False
|
||||
assert air_purifier.AIRFLOW_VS_FALLBACK.match_fn({}, {}) is True
|
||||
|
||||
|
||||
def test_airflow_fan_write_contract():
|
||||
"""Confirmed via issue #56's second, properly-spaced diagnostics round
|
||||
(two independent units, 60-90s apart per setting): /airflow/0's `speed`
|
||||
is a clean, monotonic 0-4 code, so the write is a plain int passthrough
|
||||
-- no named-preset table needed (see fan.py's LocalThingsAirflowFan)."""
|
||||
fan_desc = next(e for e in air_purifier.AIRFLOW_GENERIC.entities if e.key == 'airflow_fan')
|
||||
assert fan_desc.write_fn(('speed', 3), {}) == (['airflow', '0'], {'speed': 3})
|
||||
assert fan_desc.write_fn(('power', True, '/power/vs/0'), {}) == (
|
||||
['power', 'vs', '0'], {'x.com.samsung.da.power': 'On'},
|
||||
)
|
||||
assert fan_desc.write_fn(('power', False, '/power/0'), {}) == (
|
||||
['power', '0'], {'value': False},
|
||||
)
|
||||
|
||||
|
||||
def test_airflow_speed_reads_from_dump():
|
||||
"""The fixture's /airflow/0 (power-off snapshot) reads speed=0, and
|
||||
fan_direction stays a plain diagnostic (every dump seen reads 'Off'
|
||||
regardless of fan setting)."""
|
||||
state = _state()
|
||||
assert state['airflow_fan'] == 0
|
||||
assert state['fan_direction'] == 'Off'
|
||||
@@ -126,8 +126,10 @@ def test_no_catalog_carries_unresolved_core_references():
|
||||
|
||||
|
||||
# The hood fan is its device's primary feature: fan.py sets _attr_name = None
|
||||
# so it presents as the device itself, and never reads a catalog name.
|
||||
UNNAMED_DESCRIPTORS = {("fan", "fan")}
|
||||
# so it presents as the device itself, and never reads a catalog name. Same
|
||||
# for the ARTIK051 air-purifier's airflow_fan (issue #56) -- ordered speed
|
||||
# levels, no presets, same _attr_name = None treatment.
|
||||
UNNAMED_DESCRIPTORS = {("fan", "fan"), ("fan", "airflow_fan")}
|
||||
|
||||
|
||||
def test_every_descriptor_has_an_entity_catalog_entry():
|
||||
|
||||
Reference in new issue
Block a user