CI caught it: 8 pre-existing AC fixtures also carry genuine SmartCoolClean_/
ProgressSmartClean_ tokens in /mode/vs/0 (lnx_rac_heatpump, ara_ww_tp1_22,
windfree_oscillation, tp1x_rac_01001, fac_bora, fac_bora_2in1,
fac_bora_205_flat, cac), so odor_controller_active/odor_controller_progress
now correctly bind there too -- their golden state_keys lists just hadn't
been regenerated. Verified against the actual downloaded CI job log.
- airconditioner.py: odor_controller_active binary_sensor + odor_controller_progress
sensor, read from the /mode/vs/0 SmartCoolClean_/ProgressSmartClean_ option tokens
(SmartThings cloud custom.airConditionerOdorController capability). Read-only --
no confirmed write command.
- Reporter's TP1X_DA-AC-RAC-01001_0000 dump: fan speed and WindFree preset already
bind via the existing composite climate entity, no code change needed there.
- en.json/nl.json: new entity names for the two additions.
- cs.json: new, full Czech translation catalog (mirrors en.json topology 1:1).
- New fixture + golden + tests locking in the odor-controller behavior.