Commit Graph
7 Commits
Author SHA1 Message Date
Marc Billow daf7e3787f Add ruff (lint + format) and ty (type checking) to the project
Adds [tool.ruff] and [tool.ty] config to pyproject.toml with a curated
ruff rule set (E, F, W, I, UP, B, C4, SIM, RUF, ASYNC, LOG, G, PIE, RET,
PERF, N), pins ruff/ty in requirements-dev.txt, reformats the whole tree
with `ruff format`, and fixes the pre-existing lint and type-check debt
those tools surfaced so both run clean.

Production-code type fixes include: HA's ConfigFlowResult vs. the
generic FlowResult in config_flow.py, narrowing BoundEntity.desc to its
platform-specific subclass (SelectDesc/NumberDesc/SensorDesc/etc.) via
cast() instead of an unchecked annotation, converting HA device_class
strings to their proper enum types, a resolve_registry callback typed
as `object` instead of `DeviceRegistry | None`, and a couple of other
narrow correctness fixes (CA key type validation, an index-out-of-bounds
false positive from an empty-tuple fallback, a bool/dict argument swap).

Test-file fixes are mechanical: narrowing SamsungEntityDescription to
the correct subclass via isinstance()/cast() before accessing
subclass-only fields, and asserting Optional write_fn/unit_fn fields
are set before calling them.
2026-08-02 23:56:38 +00:00
firstof9@gmail.com 8e8f08109a fix(hood_fan): fall back to settable min/max when supportedFanSpeed is missing 2026-07-30 11:33:40 -07:00
Marc Billow 9011f84787 Model after_run_progress as a percentage, fix Dutch after-run-progress name
runningProgress's own field name states its domain, so restore unit='%' and
state_class='measurement' rather than leaving it an opaque passthrough --
that hedge made sense for activationState (no supported-values list, no
write contract to invent) but not here, where the name itself is the
evidence.

"Nadraaien voortgang" also wasn't idiomatic Dutch (nouns don't stack that
way); "Voortgang nadraaien" matches how the rest of the catalog compounds
these names.
2026-07-28 02:29:01 +00:00
Marc Billow 0640ac3477 Fix hotwater_lock key-collision hazard, address Opus review of triage fixes
An Opus review of the previous commit found that giving the switchHotwater
fallback and LOCK.hotwater_lock the same key introduced a real bug:
adapter.flatten() (the source of coordinator.data, which every switch's
is_on reads) only ever honours exists_fn, never entity.py's implicit
own-field-presence default that gates plain registration. With only one
side of the pair gated, both descriptors still wrote the same key into the
flattened state dict, and whichever was processed last -- decided by
device-reported href order, not correctness -- silently won. Reproduced
with the existing coffee fixture: reversing resource order flipped
hotwater_lock from correct (False) to a stuck True.

Fixed by gating both sides symmetrically via a shared tri-state helper that
also treats an unfetched /status/lock/vs/0 stub as "outcome pending" rather
than "confirmed absent" -- otherwise the stub window let both descriptors
pass exists_fn at once, which would have registered two switch entities
with the same unique_id. The fallback also re-asserts its own field's
presence, a check it used to get for free before it shared LOCK's key.

Also addresses two smaller findings from the same review, both in the
range-hood after-run capability (#147): runningProgress's unit='%' was a
guess from a single "0" sample with no supported-values/range field to
confirm the domain -- inconsistent with treating activationState as
read-only for the same "don't guess" reason -- so it's now a bare
passthrough sensor; and entity_category='diagnostic' was dropped from the
two read entities since after-run is a feature the user actively watches
and cancels via the (correctly uncategorized) button, not passive
diagnostics.
2026-07-28 02:25:42 +00:00
Marc Billow 5055d6bb72 Fix water-purifier hot-water lock mislabel, add range-hood after-run support
Water purifier (#144, #145): /favorite/hotwater/vs/0's switchHotwater field
is a Locked/Unlocked hot-water lock, not a "favorite enabled" flag. It's the
same lock as LOCK.hotwater_lock, just surfaced through this href on boards
that don't populate /status/lock/vs/0's hotwaterLock -- the two now share
the hotwater_lock key/translation, gated so only one is ever active.

Range hood (#147): binds /afterrun/vs/0 (after-run activation state,
progress, and a cancel button), clearing the last unbound href for
AHD-WW-TP1-22-COMMON.
2026-07-28 02:00:57 +00:00
themaanda 62caf769f2 Address cooktop and range hood review 2026-07-22 21:54:01 -05:00
themaanda c64f58aaa5 Add cooktop and range hood support 2026-07-21 16:57:45 -05:00