async_send_command handed write_fn/validate_fn the raw cache snapshot
(real, on-the-wire hrefs), not a subdevice-scoped view. Every other
consumer of a full resources dict (exists_fn, rep_fn, is_legacy_board,
...) reads through coordinator.canonical_resources() specifically to
avoid this; write_fn/validate_fn didn't, so on a composite AC (issue
#177) _temperature_step's resources.get(HREF_TEMP_CONTROL) saw the
master's /temperature/control/vs/0 instead of the subdevice's own
/temperature/control/vs/1, silently rounding a subdevice's 0.5-degree
write to a whole degree. The remote-control gate stays on the raw
snapshot -- /remotectrl/* is a shared, MAIN-only resource a
subdevice's owned-hrefs-only canonical view would drop entirely.
climate.py's target_temperature_step duplicated this same
read-in-order logic; pointed it at airconditioner._temperature_step
so the read and write paths can't drift again.
Also, from the same review:
- _quantize_temperature rejects non-finite floats (nan/inf survive
float() but raise out of round()/division, escaping write_fn's
documented None-on-bad-payload contract).
- Deduplicated the quantize-and-check block shared by the
temperature_ocf/temperature branches of _climate_write.
- Added the /temperatures/vs/0 items[]-fallback test that was
previously unreachable (every increment-carrying fixture also has
/temperature/control/vs/0, which _temperature_step checks first).
- Added a coordinator-level test seeding an indexed subdevice with its
own step, distinct from the master's, covering the fix above.
- The Towels/Bedding regression test now checks all 7 locale catalogs,
not just English -- the bug is a code-mapping error, and
test_every_language_mirrors_the_english_catalog only checks key
topology, not values.
Issue #343: DA_WM_TP1_21_COMMON's washer_cycle_table_02 had course
codes 24 and 33 transposed -- selecting "Towels" in HA ran the
washer's Bedding cycle and vice versa (confirmed against the
reporter's diagnostics dump: Course_24 selected, courseTable
Table_02). Swapped both codes' labels back in line with the 69/6A-
79/88 family's own Bedding/Towels pair (6f/70), across every locale
catalog.
Issue #342: added the four course codes the reporter's editCourseList
carried with no catalog entry -- 06 (XXL Laundry), 08 (Rinse+Spin),
and a0 (15' Quick Wash) were missing outright; 74 (Drum Clean) turned
out to already be translated by the time this landed.
The download-course request in the same issue (selecting which
program a "Download" cycle fetches) is left for a follow-up -- still
waiting on a confirmed local write path before building anything on
top of the OneTimeCloudCourse/CloudCourse fields.
washer_cycle_fallback no longer wraps an unrecognized code in an
'Unknown (0xNN)' label -- that baked untranslatable English into a
component built to be fully translatable. It now only ever surfaces a
device-provided personal-course name; an unrecognized standard code
displays as its raw value, same as before PR #251.
Also translates nl.json's '69'/'88' washer labels left in English (same
review), and makes de.json's own 'smart' states consistent with the
'Intelligente Lüftung' translation already used for smartventilation.
PR #251 and PR #275 predate this repo's ruff-format adoption on those
files; running the formatter (single->double quotes, line wrapping,
trailing-comma cleanup) keeps the merged code consistent with the rest
of the codebase. No behavior change.
Adds [tool.ruff] and [tool.ty] config to pyproject.toml with a curated
ruff rule set (E, F, W, I, UP, B, C4, SIM, RUF, ASYNC, LOG, G, PIE, RET,
PERF, N), pins ruff/ty in requirements-dev.txt, reformats the whole tree
with `ruff format`, and fixes the pre-existing lint and type-check debt
those tools surfaced so both run clean.
Production-code type fixes include: HA's ConfigFlowResult vs. the
generic FlowResult in config_flow.py, narrowing BoundEntity.desc to its
platform-specific subclass (SelectDesc/NumberDesc/SensorDesc/etc.) via
cast() instead of an unchecked annotation, converting HA device_class
strings to their proper enum types, a resolve_registry callback typed
as `object` instead of `DeviceRegistry | None`, and a couple of other
narrow correctness fixes (CA key type validation, an index-out-of-bounds
false positive from an empty-tuple fallback, a bool/dict argument swap).
Test-file fixes are mechanical: narrowing SamsungEntityDescription to
the correct subclass via isinstance()/cast() before accessing
subclass-only fields, and asserting Optional write_fn/unit_fn fields
are set before calling them.
Adds a device registry for the TP1X_DA_AC_EHS board family: separate
zone1 (space heating/cooling) and dhw (domestic hot water) loops.
zone1 is exposed as power switch + mode select + current/target
temperature sensor/number -- it's a leaving-water-temperature
setpoint, not a thermostat, so no HA platform fits it better. dhw
gets a composite water_heater entity, using the same
primary-resource-plus-sibling-reads shape climate.py already uses
for the AC (PR #247 review feedback: "Having water heaters
automatically leverage the right platform would be pretty cool!").
The unit's away mode is a device-wide switch, not the water_heater
AWAY_MODE feature -- /option/outgoing/vs/0 has no dhw-scoped sibling
and covers zone1 too, so presenting it on the DHW card would
misstate its scope.
Operation modes (Eco/Std/Force/Power) map onto HA's own standard
water_heater states, the same mapping HA core's smartthings
integration uses for this exact Samsung capability over the cloud
API. Device codes are matched case-insensitively on the read side.
The DHW entity takes a catalog name ("Hot water") rather than the
bare device name -- unlike the AC's climate card, it is one loop of
a two-loop device.
Both temperature ranges fall back as a pair: a resource reporting a
minimum but no maximum yields no range at all rather than mixing a
device bound with an invented default, matching climate._range().
Increment fallbacks test for None instead of using `or`, so a
genuine 0 survives.
set_temperature honours the optional operation_mode HA's
water_heater service schema forwards, setting the mode (and powering
the loop on) before the setpoint, the same way climate's
set_temperature handles hvac_mode.
Entity names are translated into Czech and Dutch following each
file's existing terminology conventions.
Verified against a real TP1X_DA_AC_EHS_01001_0000 diagnostics dump
(firmware AEH-WW-TP1-22-AE6000_17260402); golden-regression fixture
and full test coverage included.
- _speed_zero_is_off now keys off the hood resource's own
settableMinFanSpeed/supportedFanSpeed fields instead of asking whether
the device has any power resource at all, so a combi appliance's cavity
/power/0 can no longer be toggled off by turning off just the vent fan.
- async_turn_on() no longer resets an already-running fan to its lowest
speed when called without a percentage.
- _has_separate_power() reads through the O(1) resource cache instead of
copying the full resource snapshot on every property access.
- _kimchi_mode_write rejects values the compartment didn't advertise in
supportMode instead of writing them blind.
- kimchi_ripening_status no longer lowercases its value, since it has no
enum catalog entry to translate the lowercased token back through.
- Documented why KIMCHI_DOOR_GENERIC isn't deduped against the /doors/vs/0
aggregate fallback on the one fixture that reports both.
Adds regression tests for the combi-appliance power targeting, the
already-on turn_on no-op, kimchi mode write validation, and a kimchi
select display/write casing round-trip; a translation-coverage guard for
kimchi_zone_mode codes mirroring the existing AC preset one.
Opus review of the previous commit caught two real bugs. The airflow fan's
power writes preferred /power/vs/0, copied from the TP1X fan class -- but
that order is only harmless there because TP1X never reports /power/0 at
all. This family's dumps carry both hrefs, and the power_switch entity is
unconditionally bound to /power/0 when present, so the fan was writing to
a different resource than power_switch reads/writes, leaving the two
entities disagreeing until the next poll. Flipped to prefer /power/0,
matching the range hood's fan and common.POWER_GENERIC.
Also renamed the new FanDesc's key from 'fan' to 'airflow_fan': BoundEntity
unique_ids are derived from key alone, not href, so it collided with
air_purifier.FAN's own 'fan' key on the (currently unobserved, but
unenforced) possibility of a board reporting both.
Added a platform-level test file covering the power-href preference and
percentage<->speed-code mapping, mirroring test_range_hood_fan.py's harness.
Finishes PR #91's contribution (pedroperosin) with the requested review
changes applied, on our own branch:
- Preset resolution is now fully dynamic, read from each unit's own
/mode/convenient/vs/0 supportedModes instead of a static per-model
table -- any board's convenient modes (including WindFree's Nano/
NanoSleep) surface without code changes. Unlabelled codes across
existing fixtures (longwind, motionindirect, motiondirect, drycomfort)
plus the two new WindFree ones are added to en.json/nl.json.
- 'Auto' now maps to HVACMode.AUTO instead of HEAT_COOL: these are
single-setpoint "device decides" units, not two-setpoint heat+cool
ones. 'Fan' is added alongside 'Wind' as a second FAN_ONLY spelling;
a new _device_code_for_hvac() picks the code from the unit's own
supportedModes since the flat map can't disambiguate two device codes
mapping to one HA value.
- Detection gains a hyphenated '-RAC-' modelNum fallback (alongside the
existing '_RAC_') for cool-only global RAC variants whose
/otninformation/vs/0 ships no swVersionInfo block.
- Adds a display_light switch sourced from /mode/vs/0's opaque options
blob (inverted Light_On/Light_Off token) for boards with no dedicated
/light/vs/0 switch.
Write-path behavioural change (touches the path iterated on across
#9/#17/#27/#38/#54): power now targets the vendor /power/vs/0 instead of
the OCF /power/0, and _is_on() reads vendor-first. /power/0 is absent on
several known AC boards, so the previous OCF-first read/write pair could
report and act on stale state -- consistent with #53's "can turn on but
not off". Target temperature now picks its channel (OCF pair vs. vendor
items[]) based on which the unit actually reports, reading and writing
the same one.
The vendor temperature write and the new display-light write both carry
only the changed field(s), not the whole resource -- confirmed sufficient
on the wire, the device merges the rest itself. That requires the
coordinator's optimistic cache to do the same merge on the read side so a
setpoint change doesn't blank out current/min/max/unit for the settle
window: common.py gains merge_items_field() next to the existing
merge_options_field(), and async_send_command wires it in for any write
touching x.com.samsung.da.items.
New fixture/golden for the cool-only global RAC variant (TP1X_DA-AC-RAC-
01001, AI_RAC_GLOBAL_COOLONLY_3.0); display_light added to the goldens
for boards that gain the new options-based switch. Regenerated against
current main rather than copied from the original PR, since those
goldens had already shifted (current_temperature_c/humidity from issue
#75).
Five raw course codes were rendering unlabeled because no translation
entry existed for them, confirmed by the reporter selecting each cycle
on the physical appliance and reading back the raw code from the
entity's state:
- washer_cycle_table_02: '52' Eco Cold, '54' Towels, '60' Self Clean+
(a WF50A8600AV/US). '54' shares a display name with the existing '24'
Towels -- a different code on the same table legitimately landing on
the same label, matching the existing '21'/'65' Colors and
'27'/'5E' Rinse+Spin pairs, not a duplicate-in-error.
- dryer_cycle_table_03: '01' Normal, '06' Time dry (a DVE50A8600V/A3,
the same model added in the previous commit's detection fix).
No code changes -- select.py already derives which raw values it
normalizes from the shipped catalog, so labelling a code is purely a
translations/en.json (mirrored to nl.json) addition.
Since entity.py started routing named descriptors through the catalog
under desc.key, SamsungEntityDescription.name has been read for its
value nowhere -- only twice as a flag, to decide whether an entity was
translated at all. That left 148 English names duplicated between Python
and translations/en.json with nothing keeping them honest: six had
already drifted, invisibly, because editing the Python side changes
nothing a user sees.
So the field is gone, and translation_key defaults to desc.key. A
descriptor now sets translation_key only to share one catalog entry
across descriptors or to point at a differently-named one, and the
catalog is the only place an entity name exists.
Every descriptor resolves to exactly the translation key, icon, entity
category, enabled-default and gating it did before -- with one
deliberate exception: the hood fan, previously the sole descriptor with
no key at all, now resolves to 'fan'. That is inert, because fan.py sets
_attr_name = None so the entity presents as the device itself.
The three helpers that forwarded a name into a descriptor
(laundry.bool_option_switch, washer._bool_option_switch, air_purifier's
sensor table) lose that parameter. test_translations.py now requires a
catalog entry for every descriptor rather than only translated ones.
Claude-Session: https://claude.ai/code/session_01GiibJZZLWVvyxq7mc7EDNp
PR #68 restated its own translation data in Python: a 60-line
TRANSLATED_SELECT_STATES table of frozensets duplicating every
entity.select.*.state key, a second _TRANSLATED_COURSE_TABLES table
naming which course tables have translations, and a strings.json that
was a 835-line byte-for-byte copy of translations/en.json save 43
[%key:...%] references. Each needed hand-syncing, and one was already
drifting.
Home Assistant loads exactly one file per language for a custom
integration -- translations/<lang>.json. It never reads strings.json and
never resolves [%key:...%]; both belong to Core's build tooling, which
custom integrations don't run through (hassfest skips a missing
strings.json and validates translations/en.json instead). So en.json is
the source, and the new catalog.py reads the keys and states back out of
it for the two decisions Python genuinely has to make:
- select._display() normalizes a raw Samsung option to a lowercase
state key only when the catalog knows it, else leaves the vendor's
casing alone. Derived sets are identical to the removed literals.
- laundry.cycle_select() keys off a device-reported course table only
when that table has an entry, else falls back to the name-only
'cycle' key. Translating Table_00 is now a translations-only change.
Also fixes six names that had already drifted between the Python
descriptors and the catalog, restoring HA's sentence case for two
generic ones (Auto release dry, Bubble soak) and taking the catalog's
wording for the rest, and adds a test so the vestigial descriptor names
can't silently disagree with the UI again.
Claude-Session: https://claude.ai/code/session_01GiibJZZLWVvyxq7mc7EDNp