Commit Graph
111 Commits
Author SHA1 Message Date
Marc Billow fb2d267632 fix(water_purifier): route AILITE_DA-REF-WATERPURIFIER boards correctly (#196)
The AILITE water-purifier board (RWP70F15ANW) spells its modelNum
'...-REF-WATERPURIFIER-...', so the board-token scan hit the bare 'REF'
token before ever reaching 'WATERPURIFIER' and misrouted the device to
the refrigerator registry, whose resource surface shares almost nothing
with a water purifier -- hence the incomplete-coverage warning. Add a
documented carve-out for this one token co-occurrence and a matching
TestBoardTokenAmbiguity exception.

Also bind the water-purifier hrefs this board additionally exposes:
cup-detection status, the settings/sound/{mode,output,volume} trio (read
live, since this board's own supportedModes vocabulary differs from both
laundry's and air_purifier's hardcoded/live sets), and last-pour
statistics.

Separately, gate hot_water_temperature off when the device doesn't report
a supportedHotTemperatures list (only a hotwaterRange/hotwaterLevel pair
with no confirmed write contract) -- previously an empty options list
plus a live current value rendered as 'unknown' in HA, the second bug
reported in #196. The existing water_purifier_coffee fixture (#107) turns
out to hit the same shape, so its golden drops the entity too.

Issue #195 (TP1X_REF_21K) needed no change: its diagnostics show zero
unbound hrefs and the model already routes to the refrigerator registry,
matching the maintainer's own comment on the issue.
2026-07-29 23:23:56 +00:00
Marc Billow 9e85395b44 rename: unit/sub-unit -> subdevice, matching OCF terminology
"Unit"/"sub-unit" from #199's multi-indoor-device support wasn't OCF
idiomatic -- OCF calls each component of a composite device a
"subdevice" (see subdeviceIdList), so rename SubUnit -> Subdevice
throughout: the registry module, coordinator state, BoundEntity's
subdevice field, diagnostics keys (subdevices/subdevices_skipped/
subdevice_probes), entity unique_id prefixes (unit1_/sub_<uuid>_ ->
subdevice1_/subdevice_<uuid>_), device-name fallback labels, golden
fixtures, tests, README, and the adding-device-support skill.

Breaking change to entity unique_ids and diagnostics keys, acceptable
since this hasn't been released yet.
2026-07-29 22:57:11 +00:00
Marc Billow 9442248c20 Merge origin/main into multi-device sub-unit support
Conflict was purely additive: both sides appended golden-regression
tests at the same point in the file, and each side's last test shared
the single trailing assert block. Kept every test from both sides, each
with its own copy of that assert.

One real semantic merge on top of that. #136 (on main) remodelled the
legacy ARTIK051 board's beep from a buzzer_volume Number to a beep
Switch, and HJcom's ARTIK051_DONGLE_FAC_18K is exactly that board
generation (is_legacy_board -> True), so its golden -- written before
that change existed -- still expected buzzer_volume. Regenerated it:
buzzer_volume/unit1_buzzer_volume -> beep/unit1_beep on the master and
the second indoor unit alike, with nothing else moving and still no
unit2_ keys. That is main's intended behavior reaching the sub-unit for
free, which is the point of binding siblings through the same registry.

967 passing. Re-ran the corpus-wide unique_id audit over all 57
fixtures (main added five this branch had never seen): no collisions
within a platform.
2026-07-29 19:40:32 +00:00
Marc Billow c181a8b447 feat(subdevices): support multi-indoor-unit systems (#177)
Samsung 2-in-1 air conditioners put more than one logical indoor unit
behind a single IP and a single DTLS session. Only the unit the config
entry was set up against was ever discovered; the second one -- a whole
physical appliance the user can see in SmartThings -- had no entities at
all. Two reporters turned out to have two different mechanisms:

  ARTIK051_DONGLE_FAC_18K -- indexed siblings. /oic/res registers the
  whole tree discoverable and lists three complete parallel resource
  sets whose trailing path segment is the index (/mode/vs/0, /mode/vs/1,
  ...), on OCF-standard and vendor hrefs alike. /device/0's batch
  carries only the index-0 hrefs, so a sibling is reachable only through
  its own /device/<n> collection.

  TP2X_FAC_BORA_21K -- UUID-prefixed tree. /oic/res hides the appliance
  tree entirely (which is why a direct /device/1 probe returns nothing
  on this board). /subdevices/vs/0 carries subdeviceIdList instead, and
  that UUID appears as a literal href prefix; /<uuid>/information/vs/0
  was confirmed live to return the wall unit's own model and serial
  (TP2X_FAC_BORA_RAC_21K) against the master's TP2X_FAC_BORA_21K.

The detection signals don't overlap on either board, so no
disambiguation is needed -- enumeration checks both and takes what
answers.

Both patterns are the same thing underneath: a logical unit is a seed
collection path to poll plus an href transform between the canonical
href the registry knows and the actual on-the-wire href. That is the
whole abstraction (SubUnit), applied at four boundaries -- discovery,
the coordinator, the adapter, and the platforms. Capabilities, the
registry and the climate composite stay written against canonical hrefs
and are untouched.

Uniqueness comes from a key_prefix inside the flattened state key, so
the master unit's keys are byte-identical to every release before this
and every existing golden file is an unchanged regression guard. Each
sub-unit gets its own device-registry entry linked by via_device and
named from its own /information/vs/<n>, so it lands in its own room
rather than crowding the master's device page.

A sub-unit materializes only when it yields at least one primary
(non-diagnostic) entity with a populated value. That gate is not
decoration: the reporter's /device/2 is an unused slot that SmartThings
shows disabled, yet it answers with a full 14-href batch, and it
flattens to exactly one non-None value -- a diagnostic alarm_code
derived from an empty /alarms/vs/2. Without the entity-category filter
it becomes a phantom third climate card. The rule is deliberately
domain-agnostic rather than a list of HVAC hrefs, so a multi-drum
washer (#19) gets the same treatment with no new curation. Units that
answer but fail the gate are logged and reported in diagnostics, so a
genuinely missing unit stays diagnosable from a dump.

Enumeration fetches things that must not then be treated as appliance
state. A rejected candidate's seed has to be read to evaluate the gate,
but only units that pass are polled again, and StateCache has no
eviction -- so discovery runs before the first cache apply and those
reps are held aside for diagnostics rather than frozen into the cache
forever. /multidevice/vs/0 is probed on every device regardless of
family, so merging it into the resources dict would have reached
discovery on any board whose registry doesn't ignore that href -- only
the air conditioner one does -- raising a spurious coverage-gap repair
for a washer or fridge whose firmware answers it. It is corroborating
metadata (numofsubdevice, confirmed read-only) and now lives beside the
resources rather than in them.

Diagnostics reports each unit separately: top-level `resources` is this
unit's own and only its own, which is what the module docstring and the
adding-device-support skill have always claimed it was, and each
sibling or rejected candidate carries its own reps canonicalized so a
block reads exactly like the master's instead of needing to be
de-indexed by hand.

Fixtures are real captures. The ARTIK051_DONGLE_FAC_18K one is entirely
verbatim, both sibling seeds and the hand-read /multidevice/vs/0
included. The TP2X_FAC_BORA one has a real device0, oic_res and
sub-unit /information/vs/0, with the remainder of that unit's tree
constructed and documented as such in seeds_note; /<uuid>/device/0 is
the one part of that pattern still inferred rather than observed, and
can't be tested through the debug panel because a Collection returns a
list.
2026-07-29 19:14:51 +00:00
Marc Billow bd3ca80d3c review: address Opus code-review findings on this branch
- config_flow: the #192 port-rescue made the "every port refused" fast-fail
  permanently unreachable (PREFERRED_PROBE_PORTS is always non-empty and
  always rescued), so removed the dead branch instead of leaving it as
  misleading dead code. A dead host now fails via the handshake loop's own
  error, which carries the real per-port reason.
- oven._has_option: added the is_stub_rep carve-out cooktop.py's identical
  per-token exists_fn already has on the same kind of href, so a not-yet
  sub-polled /mode/vs/0 doesn't permanently exclude energy_saving/
  cooktop_on_alert before their first real fetch lands.
- airconditioner.ENERGY_METER_LEGACY: build via dataclasses.replace() like
  its ENERGY_METER_GENERIC sibling, instead of hand-copying href/poll_tier
  (which would silently drift if common.ENERGY_METER ever gains a field).
- Fixed two stale comments: is_legacy_board()'s docstring still listed
  Volume among tokens needing legacy-only gating, though 'beep' now applies
  unconditionally across board generations; and common.py's UNIVERSAL
  invariant comment didn't mention that airconditioner also now excludes
  ENERGY_METER from the wholesale bundle.
- #191 (CAC token): added the fixture/golden/capability-test coverage the
  AVT token in the same branch got, including an honestly-documented list
  of the ten hrefs this board generation doesn't cover yet.
- fridge.cooler_temperature_setpoint: dropped the hardcoded "N °C" state
  labels -- the resource's own unit field isn't necessarily Celsius on a
  different model reporting the same href, and the options themselves are
  already read live via options_field, so a static per-value label risked
  asserting the wrong unit for a future device sharing this capability.
- airconditioner._legacy_cumulative_power_kwh: parse with float (matching
  common.wh_to_kwh's own numeric parsing) instead of this module's
  integer-only _int, so a decimal-formatted reading doesn't raise.
- test_config_flow: the port-rescue test bound the real 49154 directly,
  which could collide with an actually-running service on some machine;
  now monkeypatches PREFERRED_PROBE_PORTS to an OS-assigned port instead.
- oven.py: consolidated six byte-for-byte-identical single-token options
  write_fns (lamp/sound/fast_preheat/natural_steam/energy_saving/
  cooktop_on_alert) into one _option_switch_write(prefix) factory.

845 tests passing (up from 841 -- 4 new CAC coverage tests).
2026-07-29 18:04:23 +00:00
Marc Billow 36240b44e6 fix(oven): gate fast_preheat/natural_steam on their own tokens (#183)
Both switches were shipped unconditionally (no exists_fn) as an unverified
guess -- the module docstring already flagged them as "unproven." Every
range/oven fixture in the corpus, including the new issue #183 dump,
reports neither fastpreheat_* nor NaturalSteam_* in /mode/vs/0's options at
all, so both were phantom controls: always read as off, and toggling them
wrote a token the firmware never recognized in the first place. That
matches the reporter's exact complaint ("doesn't appear to do anything").

Also bound two tokens confirmed present on this dump but never modeled at
all: EnergySaving_On (the 120-hour energy-saving standby from the app) and
BurnerOnAlert_Off (cooktop-on alert), following the same single-token
options-merge pattern as the existing lamp/sound/fast_preheat switches.

Child lock, the setpoint mismatch, and the missing cook-start control from
this issue are not code bugs -- see the issue comment for what was verified
and what still needs more information from the reporter.
2026-07-29 13:26:39 +00:00
Marc Billow 487ac748bd fix(airconditioner): model legacy-board beep as a switch, not a volume (#136)
Every ARTIK051_KRAC_18K-generation unit confirmed on hardware (three units
across two reporters) only ever carries Volume_100 or Volume_Mute in
/mode/vs/0's options -- never an intermediate value -- so the existing
buzzer_volume Number (0-100, step 10) modeled a control this firmware
doesn't have. Worse, its write path could never produce the literal
'Mute' token needed to actually turn the beep off, since it only ever
wrote a plain integer string. The 'beep' switch already used on newer
boards is the correct model here too; it's no longer gated off the legacy
board generation, and the Number entity is removed.

The WindFree-preset-not-applying report earlier in this issue self-resolved
per the reporter's own follow-up testing, so no code change was needed for
that part.
2026-07-29 13:16:09 +00:00
Marc Billow b5c5c056f4 feat(fridge): expose discrete cooler temperature setpoint (#186)
RT42DG6630B1FZ is a single-door "cooler only" fridge that reports its
setpoint on /temperature/definite/cooler/vs/0 -- a vendor resource outside
both TEMP_CURRENT_GENERIC's '/temperature/current/' and TEMP_SETPOINT's
'/temperature/desired/' href prefixes, so it was entirely unbound and the
setting stayed app-only. Its supportedList (1/2/3/4/7 °C) isn't a
contiguous range, so this is modeled as a select over the device's own
live options rather than a NumberDesc that would let a user pick an
unsupported value like 5 or 6.
2026-07-29 13:11:07 +00:00
Marc Billow 74f34b91a5 feat(registry): route AVT-WW-TP1-23 air purifier boards (#190)
AVT-WW-TP1-23-AXX500 (AX053B810HGD) reported device_type 'unknown' with
empty oneUiVersion, falling back to common caps. It's the same BESPOKE
Cube Air lineage as A-VTWW-TP2-21-COMMON (issue #151), just with the
'-WW-' delimiter shifted one letter left ('A-VTWW-' -> 'AVT-WW-'), which
splits into an 'AVT'/'WW' token pair the existing whole-token 'VTWW' entry
can't see. Added 'AVT' as its own board token onto the same air_purifier
registry -- the resource surface (wind/strength fan, HEPA filter, air
quality sensors, alarms) already matched with zero unbound hrefs once
routed there, so no new capabilities were needed.
2026-07-29 13:06:36 +00:00
Marc Billow d83733a670 fix(airconditioner): scale legacy ARTIK051 cumulativePower correctly (#193)
ARTIK051_KRAC_18K-generation boards report /energy/consumption/vs/0's
cumulativePower in centiwatt-hours, not the plain Wh every other AC board
family reports -- confirmed against the reporter's own SmartThings-app
reading (raw 117430000 vs. the app's authoritative 1,174.30 kWh is exactly
a /100000 factor, not the shared wh_to_kwh's /1000 alone). Split
common.ENERGY_METER into generic/legacy variants on the airconditioner
registry, discriminated by the existing is_legacy_board() check, so every
other AC family keeps the unmodified shared capability.
2026-07-29 13:04:33 +00:00
Marc Billow a6eb1c62d4 feat(microwave): add filter reminder / end signal reminder switches (#181)
Both FilterRemind_*/RemindBeep_* option-array tokens are already
present -- and both On and Off already confirmed -- on the existing
ME7500D fixtures (issue #152), so this is a straight sibling of the
Sound/Lamp switches rather than new discovery work. Gated with
exists_fn like Lamp since the MW7300B combi dump has neither token.

Doesn't address the rest of issue #181 (power-level slider,
non-reported cooking modes, 3-level light, child lock, send-to-
microwave) -- those need write-contract confirmation this dump
doesn't carry.
2026-07-29 02:55:47 +00:00
Marc Billow 2b24152276 feat(registry): cover absence-power-saving and motion-detect-wind on AC (#173)
Lennox-branded heat pump on the Samsung RAC board family (modelNum
TP1X_LNX-AC-RAC-01001_0000) already routes correctly via the existing
'-RAC-' token, but its dump has two resources no prior AC fixture
carried: /mds/absencepowersaving/vs/0 and
/option/motiondetectwind/stateful/vs/0. Bind both as read-only
sensors, matching the CURRENT_LIMIT/ANOMALY_LOAD precedent -- nothing
in the dump confirms write safety on live HVAC hardware.
2026-07-29 02:52:33 +00:00
Marc Billow bbf3f3f833 Revert unsound air-quality gating from #170, cover remaining fan-speed icons
An Opus review of merged PR #170 found the cleanLevel-scalar existence
gate on AIR_QUALITY doesn't hold up as a general rule: three fixtures
in this repo (air_purifier_device.json, air_purifier_vtww_device.json,
range_hood_device.json) carry genuinely populated Dust/FineDust/
SuperFineDust readings with no such scalar, so requiring it risks
silently dropping real air-quality readings on AC hardware this repo
hasn't seen yet. Reverted _has_sensor_type to item-type presence only
(as before #170) and moved the #166 fix to enabled_default=False on
all five entities instead -- same conservative, non-existence-gated
treatment already used for tropical_night_mode and the fridge/cooktop
precedents it was modeled on. Golden fixtures and tests updated to
match; the five sensors are bound-but-disabled on windfree/#17-style
boards again rather than unbound.

Also added icons for the AC fan_mode values #170 missed -- the raw
numeric labels ("1".."5") that TP1X_DA-AC-RAC-01001 and the window-AC
board report instead of turbo/max -- and swapped the whole fan-speed
icon family to mdi:fan-speed-1/2/3 for a more purpose-built look than
the generic speedometer, applied consistently to both the AC climate
card and the air purifier fan. Fixed motiondirect/motionindirect to
match core's smartthings integration's arrow pairing (previously
inverted).

Known limitation, not fixed here: enabled_default only affects newly
registered entities. Anyone who already has tropical_night_mode or the
five air-quality sensors enabled from #164 (a narrow window before
this fix, but real) won't see them auto-disable -- they'd need to
disable them by hand in Settings > Devices > Entities. A real fix
needs a one-time entity-registry migration, which this integration has
no existing infrastructure or test coverage for; scoping that felt
like its own follow-up rather than something to bolt on here.
2026-07-28 19:07:59 +00:00
Marc Billow 739881de16 Gate AC tropical night mode and air-quality sensors on real capability signals (#166)
Issue #166 (ARxxTXFCAWKNEU, board ARTIK051_PRAC_20K) reported tropical
night mode, clean level, dust, fine dust, odor, and super fine dust
entities showing up even though the reporter's units have no such
physical features. All six were added in #164.

The Sleep_<N> options token backing tropical_night_mode is present in
every AC dump on record regardless of confirmed reality, so there's no
usable signal at boot time -- it's now registered but disabled by
default (matching the precedent already set by fridge.rack_count /
cooktop.paired_hood_model), letting units that do have it opt in.

/sensors/vs/0's item-type list has the same problem (all five types
always listed, permanently zero on this board), but there turned out
to be a real tell: a top-level x.com.samsung.da.cleanLevel scalar is
present only alongside genuinely populated readings on every dump on
record (tp1x_da_ac_rac_01011, the tp1x_da_ac_air air purifier fixture)
and absent on every all-zero ARTIK051_PRAC_20K dump, including both
#166 units and the original windfree/#17 fixtures this capability was
first verified against -- which, per their /information/vs/0, turn out
to be the same board revision as #166's units, so that "verification"
never actually proved a real sensor either. AIR_QUALITY's exists_fn now
requires that scalar, and the windfree/airconditioner golden fixtures
are updated to match (those five entities no longer bind there).
2026-07-28 18:12:02 +00:00
Marc Billow 65b0326d62 Merge remote-tracking branch 'origin/main' into claude/issue-triage-138-latest-y90g78
# Conflicts:
#	tests/test_airconditioner_capabilities.py
2026-07-28 14:51:29 +00:00
Marc Billow 5a73a25005 Address independent code review findings on PR #167
Two real bugs, both latent (no shipped fixture exercised them), plus a
consistency gap and a couple of correctness/DRY nits flagged by review:

- async_set_fan_mode resolved a fan_mode label against the static
  _FAN_TO_DEVICE reverse map before checking whether the resulting code is
  actually one of the unit's own supportedModes. A board using non-standard
  wind-strength codes while still spelling a standard-looking label in
  modesName (e.g. codes "31"-"33" named "Low"/"High"/"Turbo") would silently
  write a code ("1"/"3"/"4") the device never advertised. Now validates the
  static hit against the unit's own supported codes before trusting it,
  falling through to the live modesName scan otherwise.

- air_purifier.WIND_STRENGTH_FAN reused key='fan', the same key as FAN in
  the same registry -- BoundEntity's unique_id is built from key alone, not
  href, so a board reporting both hrefs would have one fan entity silently
  shadow the other. Renamed to 'wind_strength_fan' (translation_key
  unchanged). No shipped fixture reports both hrefs today, but the two caps
  living in the same registry made this a real latent hazard, the exact one
  AIRFLOW_GENERIC's own comment already documents and deliberately avoids.

- microwave.py's cooking_mode select still used a static, union-of-all-
  dumps mode list, even though both shipped microwave fixtures already
  report x.com.samsung.da.supportedModes on /mode/vs/0 -- the same shape
  oven._oven_mode_options was just built to prefer over exactly this kind
  of static list (issue #138's follow-up, this same PR's skill update).
  ME7500D advertises 4 modes; the select was offering 11. Applied the same
  live-first, static-fallback pattern.

- Added the issue #152 fixture the microwave lamp fix was missing (the
  SKILL.md step this PR itself added asks for one).

- climate.py's _legacy_airflow rebuilt a 2-key presence dict from
  coordinator.resource()'s truthiness, which collapses "href absent" and
  "href present with an empty {} rep" to the same falsy value -- while
  is_legacy_board (and discover()'s own binding) test key membership, not
  truthiness. Simplified to pass last_resources through directly, matching
  is_legacy_board's actual contract instead of a cheaper approximation of
  it, so the "can never disagree" claim in both docstrings is actually true.

- Hoisted the 'power' payload branch duplicated verbatim across
  _airflow_fan_write/_fan_write/_wind_strength_fan_write into one
  _power_write helper (registry/capabilities/air_purifier.py).

- Removed two now-unused imports (test_air_dresser_capabilities.py,
  test_air_purifier_vtww_fan.py) and replaced a tautological
  code-in-_DEVICE_TO_FAN check with one that actually exercises the live
  climate entity's fan_modes/fan_mode (test_climate_ac_modes.py).

- Fixed a pre-existing (not from this PR) no-op test on main --
  test_registry_reproduces_golden_state_keys_for_induction_cooktop computed
  golden/state_keys and never asserted on them.

756 tests pass.
2026-07-28 14:37:32 +00:00
Marc Billow dc3e1255d1 Ignore fridge /rm/control/vs/0 plumbing href (#165)
TP1X_REF_21K's EU region variant reports a bare resource-monitoring
poll-interval config (minPeriod in ms) the US variant doesn't -- the only
unbound href keeping the coverage-gap repair open. Door sensors, the
reporter's actual ask, were already covered generically by
fridge.DOOR_GENERIC/DOORS_FALLACK.
2026-07-28 14:27:15 +00:00
Marc Billow daa7546208 Add device support for Wind-Free 2-in-1 AC TP2X_FAC_BORA_21K (#150, #153)
This board (a floor-standing + wall-mounted indoor unit pair sharing one
outdoor unit and one local IP) reports no oneUiVersion and carries the
'_FAC_' modelNum token, which no existing routing rule matched -- it fell
back to 'unknown' and exposed nothing but a power switch, with no climate
entity generated at all (both issues' reported symptom).

Once routed to the existing airconditioner registry, it binds cleanly
against the exact same CLIMATE composite every other room-AC family uses --
same Cool/Dry/Wind/AIComfort mode vocabulary, same wind-strength/humidity/
filter/energy resource shapes already modeled. Only two hrefs are unique to
this board: /subdevices/vs/0 (an opaque paired-subdevice id list -- issue
#150 asked whether the second indoor unit can be controlled separately;
it can't through this or any other resource in the dump, the same
"remote device ids, not locally actionable" role as the existing
/remotedeviceinfo/vs/0 ignore) and /runn/vs/0 (a single undocumented int
with no supported-values list to interpret). Both added to _AC_IGNORED
rather than guessed at.
2026-07-28 14:09:21 +00:00
Marc Billow fcd34f73e5 Add device support for BESPOKE Cube Air A-VTWW-TP2-21-COMMON (#151)
This board reports no oneUiVersion and no modelNum token any existing
family routed on, so it fell back to unknown -- exposing nothing but power
even though most of its resources (air quality sensors, HEPA filter,
device-active, diagnosis, plumbing hrefs) are already handled generically
by the existing air_purifier registry via the '-VTWW-' modelNum fallback.

The one genuinely new piece is its fan: this board reports wind strength as
numeric codes ("87"/"89"/"90"/"91") on /wind/strength/vs/0 with a separate
modesName array ("SMART"/"MAX"/"WINDFREE"/"Sleep") giving the actual names,
unlike the existing TP1X_DA-AC-AIR family where supportedModes IS the name
list already. Generalized LocalThingsAirPurifierFan to resolve a mode code
through modesName when present (same live-label pattern as climate.py's AC
wind-strength fix, issue #155) instead of adding a second hardcoded fan
class, and added WIND_STRENGTH_FAN reusing the same 'air_purifier_fan'
translation catalog -- both board generations land on the identical
smart/max/windfree/sleep vocabulary already labelled there.

/mode/convenient/vs/0 is empty on this dump and added to COVERAGE alongside
the existing plumbing hrefs this board also shares with the TP1X_DA-AC-AIR
family.
2026-07-28 13:58:08 +00:00
Marc Billow a3d9cce164 Extend AirDresser support to DA_DF_TP2_20_COMMON (#157)
A different board generation from issue #162's DA_DF_A51_20_COMMON, also
carrying the '_DF_' modelNum token and so already routed into the
air_dresser registry -- but reporting two resources #162's board doesn't:

  /st/airdressercourse/vs/0 -- the course table id (Table_00), read the
    same way washer/dryer read /st/washercourse|dryercourse/vs/0. Wired up
    as AIR_DRESSER_COURSE's table_href and added to the global ignore list,
    mirroring that existing pair exactly.
  /airdresseroption/sanitize/vs/0 -- a genuine on/off setting (not covered
    by any existing capability), added as AIR_DRESSER_SANITIZE.

Introducing table_href means the course select's translation_key is now
always the table-lookup callable, so the bare 'air_dresser_cycle' catalog
entry added for #162 (only ever used when no table_href was passed) is
unreachable in every case and is removed -- both boards fall back to the
shared 'cycle' entry until their course tables get named, same as
washer/dryer's own precedent for an unrecognized table.
2026-07-28 13:50:59 +00:00
Marc Billow 053e15bba6 Add device support for Samsung AirDresser DA_DF_A51_20_COMMON (#162)
This board reports no oneUiVersion and no modelNum token any existing
family routed on, so it fell back to the global unknown-device CAPABILITIES
set -- exposing only power/child-lock/start-stop-pause/delay/energy/machine
state, with /course/vs/0, /diagnosis/vs/0, and /washer/vs/0 all unbound and
no course/mode select at all (the actual reported gap).

Every one of those resources turns out to already be handled by the shared
laundry machinery: /diagnosis/vs/0 reuses dishwasher.DIAGNOSIS, and
/course/vs/0's cycle select works unmodified through laundry.cycle_options'
existing supportedOptions fallback (this board has no /wm/editcourse/vs/0
at all, so editCourseList never populates). /washer/vs/0 gets a new minimal
AIR_DRESSER_SETTINGS capability (wrinkle_prevent only) rather than reusing
dryer.DRYER_SETTINGS wholesale, since this device never reports
dryLevel/dryTime/dryerType at all and binding them would ship three
permanently-unavailable sensors.

Course codes aren't identified yet (no code->name mapping was reported), so
they render as their raw codes until named in translations, same as
dryer.py's precedent for unidentified codes.
2026-07-28 13:45:49 +00:00
Marc Billow aa9cdd83b7 Read AC fan speeds from the device's own modesName, not just 0-4 (#155)
TP1X_DA-AC-RAC-01001_0000 (model AR07C9150HZN) reports /wind/strength/vs/0
supportedModes as "0"/"31"-"35" instead of the "0"-"4" scale climate.py's
_DEVICE_TO_FAN was built from. Only "0" matched, so fan_mode/fan_modes
silently dropped every speed but Auto -- exactly the reported symptom.

Rather than hardcoding a second numeric scale, codes _DEVICE_TO_FAN doesn't
cover now fall back to the device's own modesName label (parallel-indexed
with supportedModes), mirroring how preset_mode already resolves dynamically
off a device's own supportedModes instead of a per-model table. Boards using
the standard 0-4 scale are unaffected -- _DEVICE_TO_FAN is still tried
first, so existing auto/low/medium/high/turbo labels don't change.
2026-07-28 13:38:42 +00:00
Marc Billow 00c1d78373 Merge main into ac-additive-entities, resolve conflicts with #146
Both PRs independently modeled the same /mode/vs/0 Volume_*/Sleep_*
option tokens: #129 as beep/tropical_night_mode, #146 (already merged)
as buzzer_volume/good_sleep gated to the legacy ARTIK051 board
generation. They also each defined a helper named _option_token with
different return semantics (full token vs. value half) in
non-overlapping parts of the file, so git didn't flag it as a
conflict even though the second definition silently shadowed the
first.

Keep a single _option_token (value-half, the one already used by
buzzer_volume/good_sleep/spi/etc.), adjust beep's read/write to that
convention, and gate beep/tropical_night_mode off the legacy board so
they don't duplicate buzzer_volume/good_sleep on ARTIK051_KRAC-class
devices. Added a regression test locking in the gate.
2026-07-28 13:28:20 +00:00
Marc Billow 123455a873 Add missing oven cook modes for NE63A6511SS/AA range (issue #138)
The range/oven-combo device in issue #138 (NE63A6511SS/AA, no
/information/vs/0) already resolves cleanly to the range registry via the
issue #74 for_device_by_resources fallback, with zero unbound hrefs -- the
reporter was just on an older release (0.11.1) predating that fix.

However its /mode/vs/0 supportedModes advertises ConvectionRoast, KeepWarm,
BreadProof, AirFryer, Dehydrate, SelfClean, and SteamClean, none of which
were in oven._OVEN_MODES. Since range.py reuses oven.OVEN_MODE's SelectDesc
wholesale, those modes were silently rejected by the mode select's write
validation and missing from its options. Extend the confirmed mode list and
lock in a scrubbed fixture, golden, and test for this dump.
2026-07-28 13:12:40 +00:00
Marc Billow f5be651430 Merge pull request #146 from perseus177/artik051-krac-legacy-ac
Support ARTIK051_KRAC_18K air conditioners (issue #136)
2026-07-28 08:00:48 -05:00
blka 1bbecfa5c3 Drop /information/vs/0 version entities per review
mbillow's follow-up review: exposing read-only Software/Firmware (and
Outdoor/Touch IC) version strings is "data for the sake of exposing it" --
no user control, just clutter, and every other registry leaves
/information/vs/0 in the global ignore as identity plumbing. Conforming to
that stance rather than expanding the entity surface for no user story.

- by_type/airconditioner.py: revert to *ignored.IGNORED (no _IGNORED_LESS_INFO
  filter); drop airconditioner.INFO from the registry.
- capabilities/airconditioner.py: remove the INFO capability, the _info_version
  /_info_items_of_type /_has_info_version helpers, and HREF_INFORMATION.
- translations/{en,nl}.json: drop software_version, firmware_version,
  firmware_version_2/3, outdoor_unit_version, touch_ic_version.
- tests: drop the six INFO tests; golden regenerated for 8 AC + dehumidifier.
625 tests pass.
2026-07-28 10:07:39 +02:00
Marc Billow cc570533a0 Merge pull request #149 from mbillow/claude/ticket-127-device-coverage-xsb0m4
Distinguish not-yet-fetched stub reps from confirmed-empty ones (issue #127)
2026-07-27 22:25:38 -05:00
Marc Billow 33786ad584 Distinguish not-yet-fetched stub reps from confirmed-empty ones (issue #127)
parse_device0_batch used to collapse /device/0's {"href": "..."} "no data
yet" marker into a plain {}, indistinguishable from a resource the device
had actually polled and confirmed empty. Every exists_fn using the "not
rep or ..." stub carve-out (and entity._is_included's default field-gate)
then treated both the same way, creating phantom always-"unknown" entities
for any resource a model simply doesn't support (e.g. GSzabados's fridge's
/energy/consumption/vs/0).

is_stub_rep() now recognizes only the literal {"href": ...} marker as a
stub; a genuine {} is treated as the device's real (if empty) answer and
gates the entity off like any other missing field. Updated the energy
meter, self-check error, cooktop burner, and range-hood auto-operation
exists_fn call sites, plus three golden fixtures that had baked the
phantom-entity behavior in as "expected".
2026-07-28 02:57:30 +00:00
Marc Billow e60fdf26d2 Merge pull request #148 from mbillow/claude/triage-issues-144-147-yv80ab
Fix water-purifier hot-water lock mislabel, add range-hood after-run support
2026-07-27 21:31:31 -05:00
Marc Billow 5055d6bb72 Fix water-purifier hot-water lock mislabel, add range-hood after-run support
Water purifier (#144, #145): /favorite/hotwater/vs/0's switchHotwater field
is a Locked/Unlocked hot-water lock, not a "favorite enabled" flag. It's the
same lock as LOCK.hotwater_lock, just surfaced through this href on boards
that don't populate /status/lock/vs/0's hotwaterLock -- the two now share
the hotwater_lock key/translation, gated so only one is ever active.

Range hood (#147): binds /afterrun/vs/0 (after-run activation state,
progress, and a cancel button), clearing the last unbound href for
AHD-WW-TP1-22-COMMON.
2026-07-28 02:00:57 +00:00
Marc Billow 265d94eded Add kimchi-refrigerator compartment coverage (issue #26)
TP2X_REF_20K-class 3-compartment kimchi refrigerators report each
compartment's storage mode and ripening status/timer on
/status/kimchi/<slot>/vs/0, plus a top-compartment door sensor on
/kimchidoors/top/vs/0 -- all previously unbound. Bind them as pattern
capabilities (fridge.KIMCHI_ZONE, fridge.KIMCHI_DOOR_GENERIC), deriving
the per-compartment entity key and display name from the href's
top/middle/bottom segment, the same way DOOR_GENERIC/TEMP_CURRENT_GENERIC
already do.

Storage-mode option labels were translated directly from the reporter's
own SmartThings app screenshots rather than guessed from the raw device
codes or their English paraphrase, confirming the on-screen option order
matches supportMode's array order (including the freezer triplet's
-19/-21/-17°C -> Standard/Strong/Weak mapping).

Also tighten FLEX_ZONE's exists_fn: this device's /mode/vs/0 also
populates modes/supportedOptions, but with a token shape that never
overlaps (a "_[n]:[n]" suffix supportedOptions carries that modes never
repeats), so the existing "supportedOptions is nonempty" check let the
entity bind anyway and get stuck permanently on "unknown". Requiring an
actual resolvable value keeps it working for the RF9000/Bespoke-class
fridges it was built for while leaving it absent here.
2026-07-28 00:35:21 +00:00
perseus177 3032b0c032 test(airconditioner): lock in the ARTIK051_KRAC_18K surface
Fixture is a scrubbed diagnostics dump from the unit the writes and
calibrations were verified on; the issue #136 unit is the same model with a
slightly different token set (no Spi, FilterTime_5460, OutdoorTemp_81), which
the presence gating handles the same way.

Covers the pieces the golden's state_keys can't: that the token entities stay
off newer boards, that an absent token yields no entity, that humidity's zero
reads as unknown, that fan/swing/preset read and write through /airflow/vs/0
and the Comode token, and that a board with /wind/* and /mode/convenient/vs/0
still takes the resource paths.

Refs #136
2026-07-28 02:28:59 +02:00
Marc Billow e9281aaead Bind microwave built-in vent fan's /hood/fanspeed/vs/0 (issues #137, #142)
Combi microwave units report their vent fan on the same resource shape a
standalone range hood uses, so reuse range_hood.HOOD_FAN directly in the
microwave registry. Unlike a standalone hood, this board has no sibling
/power/0 or /power/vs/0 resource, so LocalThingsRangeHoodFan now falls
back to treating fan speed 0 as the off state when no separate power
resource is present. Also gate HOOD_FAN's automatic_operation sensor on
field presence, since this board doesn't report it.
2026-07-28 00:18:38 +00:00
Marc Billow ed5e8e57c8 Merge pull request #140 from mbillow/claude/v0-13-0-issue-triage-9zfjbj
Split microwaves into their own device type instead of the oven registry
2026-07-27 17:10:10 -05:00
Marc Billow a1f14cd633 Split microwaves into their own device type instead of the oven registry
Microwaves (combi and plain) were routed onto the oven registry (issue
#121), which meant entities carried oven-flavored keys (oven_state,
oven_mode, oven_setpoint) and inherited oven-specific behavior that's
wrong for this family: a 30-270C setpoint range instead of this family's
actual 40-200C, a cooking-mode list missing MicroWave/MicroWaveGrill/
MicroWaveConvection/KeepWarm entirely, and a lamp switch that read/wrote
the oven's 'UpperLamp' option token instead of this family's 'Lamp' token.

Adds a microwave device type (by_type/microwave.py,
capabilities/microwave.py) that reuses the oven board family's shared
operational-state/door/connected/recipe-cook capabilities but defines its
own cooking-mode, setpoint, and cavity capabilities with the corrected
bounds/vocabulary, plus a new power_level sensor for the cavity's Watt
setting that was previously unexposed.
2026-07-27 22:05:54 +00:00
Marc Billow 2be742489b Fix airflow fan power-href preference and unique_id collision risk
Opus review of the previous commit caught two real bugs. The airflow fan's
power writes preferred /power/vs/0, copied from the TP1X fan class -- but
that order is only harmless there because TP1X never reports /power/0 at
all. This family's dumps carry both hrefs, and the power_switch entity is
unconditionally bound to /power/0 when present, so the fan was writing to
a different resource than power_switch reads/writes, leaving the two
entities disagreeing until the next poll. Flipped to prefer /power/0,
matching the range hood's fan and common.POWER_GENERIC.

Also renamed the new FanDesc's key from 'fan' to 'airflow_fan': BoundEntity
unique_ids are derived from key alone, not href, so it collided with
air_purifier.FAN's own 'fan' key on the (currently unobserved, but
unenforced) possibility of a board reporting both.

Added a platform-level test file covering the power-href preference and
percentage<->speed-code mapping, mirroring test_range_hood_fan.py's harness.
2026-07-27 21:48:23 +00:00
Marc Billow d4583b3240 Add real fan-speed control for ARTIK051_TVTL air purifiers (issue #56)
/airflow/0's speed was left read-only because the first round of diagnostics
wasn't conclusive (0 for both Auto and High, 3 for Low/Medium and Sleep) --
likely because all five dumps were captured within about a minute of each
other, faster than this integration's own poll cycle could settle each
change. A second round, captured 60-90s apart per setting on two independent
units, confirmed a clean monotonic 0-4 mapping across Auto/Sleep/Low/Medium/
High instead.

Builds an ordered-speed fan off that confirmed range, the same SET_SPEED
shape as the range hood's fan -- this board never self-reports a
supportedModes-style label list, so there's no named-preset table to
preserve, just percentage steps over the raw code. /airflow/vs/0's vendor
speedLevel stays a read-only fallback since it was unreliable in that same
second round.
2026-07-27 21:32:44 +00:00
blka b18500dec3 Merge upstream/main into ac-additive-entities
Conflicts resolved:
- capabilities/airconditioner.py: keep my NumberDesc/SelectDesc imports +
  upstream's hoist of _filter_usage_percent -> common.filter_usage_percent
  (local def removed by upstream's auto-merge; AIR_FILTER.air_filter_usage
  now references the common helper). Upstream's ANOMALY_LOAD, HREF_WIND_OSCILLATION
  and oscillation climate-write kind kept; my beep/tropical/INFO/AIR_QUALITY/
  threshold-Select/filter-hours kept. Both change sets coexist.
- translations/{en,nl}.json: switch section -- keep both my 'beep' and
  upstream's display/pet_filter_activation/auto_empty/dustbin_auto_close/
  uvc_intensive_mode entries.

Regenerated the 8 AC + dehumidifier goldens (+ the 2 new upstream AC fixtures
ara_ww_tp1_22, windfree_oscillation) against the merged code. 631 tests pass.
2026-07-27 22:36:06 +02:00
blka 51fa1c5ea8 Address review: per-item versions, writable threshold, unit_fn, gating
Per mbillow's review on PR #129 (CHANGES_REQUESTED). Items 1-7 + smaller.

1. INFO: expose each /information/vs/0 version item per (type, ordinal) instead
   of collapsing to a single first-Firmware value. Boards carry 1-3 Firmware
   items (separate MCUs) plus an Outdoor unit and (window AC) a Touch IC item;
   each is a distinct version string. _info_version(items, type_, ordinal)
   + _has_info_version exists_fn gate, so an item with no number (tp2x_rac_20k's
   second Firmware) suppresses the entity rather than binding unknown.

2. air_filter_threshold is locally writable, not cloud-only -- confirmed live
   on ARTIK051_PRAC: POST filterDesiredUsage=700 to /filter/airdustfilter/vs/0
   -> 2.04, read-back 700, persists; restored to 500. Converted from a
   read-only sensor to a SelectDesc keyed to the device's
   supportedFilterDesiredUsage enum (options_field), with a write_fn that
   POSTs the scalar field. Only binds where the enum is advertised; boards
   without it leave this writable field unexposed rather than guess the valid
   set (don't-guess).

3. air_filter_usage_hours uses unit_fn reading filterCapacityUnit ('Hour'->'h')
   instead of a hardcoded unit, so a board advertising a different unit doesn't
   mislabel a duration statistic.

4. air_filter_usage_hours state_class is total_increasing, not measurement --
   filterUsage is a lifetime hour counter that resets on filter replacement.

5. INFO and air_filter_threshold now carry exists_fn (AIR_QUALITY already did),
   so they don't bind a permanently-unknown entity when their item/field is
   absent. Also fixes the caww_tp2 golden nuance (filterDesiredUsage absent
   -> no threshold key, matching what HA would actually create).

6. AIR_QUALITY: CleanLevel is corroborated as numeric by a top-level
   x.com.samsung.da.cleanLevel scalar (tp1x_da_ac_rac_01011 reports both as
   '1'), so clean_level is now an int measurement; odor/dust/fine_dust stay
   string diagnostics. Reinstated the 2-element-array ambiguity note (Dust/
   FineDust/SuperFineDust report ['0','0']; v[1] meaning unconfirmed, v[0]
   taken as the reading). SuperFineDust is now modeled for consistency with
   Dust/FineDust (same shape), rather than skipped without reason.

7. _beep_write restores the last non-Mute Volume level on 'On' instead of
   forcing Volume_100, so an intermediate setting (e.g. Volume_50 set via
   the cloud) survives an off/on cycle; falls back to 100 when no prior level.

Smaller: test_air_quality now asserts the tp1x_da_ac_rac_01011 clean_level==1
non-zero reading (the one value_fn-regression catch in the corpus); renamed
by_type's _AC_IGNORED -> _IGNORED_LESS_INFO to resolve the two-meaning
collision with the capabilities module's _AC_IGNORED (href strings); golden
regenerated for the 8 AC fixtures + dehumidifier.

612 tests pass.
2026-07-27 22:22:56 +02:00
Marc Billow 8b44fd5710 Add device support for the stick-vacuum clean/auto-empty station (issue #131)
A-VSKR-TP1-22-VS9500AL connects successfully but its dump shows no
vacuum-body state at all -- no suction level, no battery, no cleaning
mode -- only the clean/auto-empty station's own dustbag, dustbin
auto-empty settings, and UV-C sanitizing-cycle status. This strongly
suggests the WiFi/DTLS module lives in the station, not the handheld
stick, so the station is the only "device" this integration's local
API can reach at all.

New vacuum_station device type (these hrefs share nothing with any
existing family, so there's no shared-href ambiguity to resolve
against another type) routed via a new '-VSKR-' modelNum fallback.
Binds with zero unbound hrefs: dust-bag full/usage sensors, auto-empty
and dustbin auto-close switches, a discharging-time select, and
clean-station status including UV-C intensive mode, operation time,
and finished/emitted timestamps. A couple of fields with unconfirmed
exact semantics (stick_status, dustbag_usage's unit) are exposed as
plain diagnostic values rather than an asserted binary/percentage
meaning.
2026-07-27 14:11:06 +00:00
Marc Billow 4e1eb7d03d Add fan-mode control for TP1X_DA-AC-AIR air purifiers (issue #130)
This newer board family reports fan modes (Smart/Max/Mid/WindFree/Sleep)
directly on /mode/vs/0's top-level modes/supportedModes fields, unlike
the older ARTIK051_TVTL family this registry already supported, which
packs everything into an options[] array with no usable fan-speed
selector at all (see the module docstring's Comode_Off finding). Both
board generations share the /mode/vs/0 href, so the existing MODE
capability and a new FAN capability are discriminated by a match_fn
checking for the top-level supportedModes field, rather than adding a
new device type.

The fan entity only exposes PRESET_MODE, not an ordered percentage --
WindFree/Smart/Sleep are named behaviors, not "faster/slower" positions
relative to Max/Mid, matching how the AC family's own named convenient
modes are modeled as a preset rather than a speed number.

Also picked up the rest of this board's previously-unbound hrefs while
in there (display, HEPA filter, panel status, pet-filter mode, sound
settings), reusing airconditioner.DISPLAY_LIGHT and
airconditioner.MUTE_ONCE for the two hrefs identical to the shared
DA-AC- board family, since the "incomplete capability coverage" repair
was firing on more than just the fan gap the issue described.
2026-07-27 14:08:32 +00:00
Marc Billow e44fef7085 Route combi microwaves onto the existing oven registry (issue #121)
TP1X_DA-KS-MICROWAVE-01041 (MW7300B) reports no oneUiVersion and an
unrecognized consumer token, so it fell back to 'unknown' and only got
common capabilities. It shares the same '/oven/vs/0' cavity resource
and '/mode/vs/0' cook-mode shape (Convection/AirFryer/Grill/MicroWave*)
as the wall oven already supported, so this reuses that registry via a
new '-MICROWAVE-' modelNum fallback rather than adding a new device
type. The only href it didn't already cover was /recipe/cook/vs/0, an
empty quick-recipe-display blob bound with no entity per the 'don't
guess' rule.
2026-07-27 13:41:36 +00:00
Marc Billow 6f10a3b796 Support 2-axis wind oscillation and overload-protection status on newer WindFree boards (issue #126)
Newer TP1X_DA-AC-RAC-01011_0000 firmware (Bespoke AI WindFree Deluxe,
AR60H10D1JWNME) drops /wind/direction/vs/0 entirely and reports swing
via a separate vertical/horizontal Swing|Fix pair on
/wind/oscillation/vs/0 instead, which left swing_mode/swing_modes
silently empty and the href unbound. climate.py now falls back to the
oscillation resource when /wind/direction/vs/0 is absent, mapping the
same off/vertical/horizontal/both vocabulary the existing swing control
already uses.

Also binds the board's /anomalyload/vs/0 overload-response resource as
read-only diagnostic sensors (operation state + mode) -- the same
"don't guess" precedent as the existing CURRENT_LIMIT capability, since
nothing in the dump confirms the exact behavioral difference between
its 'Alarm' and 'PowerSaving' modes or whether toggling it is safe on
live HVAC hardware.

Most of the other gaps this issue reported (Fan-only mode, WindFree
preset labels, target-temperature channel selection, power on/off via
the vendor resource) turned out to already be fixed by the just-merged
cool-only global RAC work.
2026-07-27 13:41:04 +00:00
Marc Billow f62b4aeec8 Detect ARA-WW-TP1-22-COMMON wall-mount RACs as airconditioner (issues #115, #116, #117, #120)
AR10/13/18BYEAAWKNME report no oneUiVersion and no '_RAC_'/'-RAC-'
token at all, so for_device_by_model() fell through to 'unknown' and
every href went uncovered. The board carries the same TP1X-class
resource surface as every other room AC already supported (mode/
convenient/wind/temperature/power/filter/humidity), so this reuses the
existing airconditioner registry via a new 'ARA-WW-' modelNum fallback
rather than adding a new device type -- confirmed against all four
reporters' dumps binding cleanly with zero unbound hrefs.
2026-07-27 13:40:12 +00:00
Marc Billow 46dd91ce32 Add regression coverage for NE8300D range (issue #112)
TP1X_DA-KS-RANGE-0102X already resolves via the '-RANGE-' modelNum
fallback and /cooktopmonitoring/vs/0 already binds through
range.COOKTOP_MONITORING, so this model binds with zero unbound hrefs
today -- add a fixture to lock that in.
2026-07-27 13:39:51 +00:00
Marc Billow 085e80c92c Add regression coverage for WA55A7700AV washer (issue #111)
The DA_WM_TP1_21_COMMON board family already routes through the 'WA'
consumer-model-prefix fallback and binds cleanly against the washer
registry with zero unbound hrefs, but no fixture locked that in for
this specific board generation -- add one.
2026-07-27 13:39:30 +00:00
blka 3da01f80d0 feat(airconditioner): add beep, tropical night, filter hours/threshold, air-quality, sw/fw version
Layer the ARTIK051_PRAC additive entities onto the upstream registry on a
fresh branch (additive-only; the round-1 display-light/mute-once/WindFree
work was independently shipped upstream and is not redone here).

New entities, all driven by single-token option_write or item reads:
- beep (switch): Volume_Mute/Volume_100 option token; single-token merge --
  a full options RMW reverts on ARTIK051_PRAC. Cloud counterpart:
  samsungce.airConditionerAudioFeedback (on/off only; level is cloud-only).
- tropical_night_mode (number 0-16): Sleep_<N> option token. Cloud:
  custom.airConditionerTropicalNightMode.
- air_filter_usage_hours / air_filter_threshold (duration sensors, h):
  raw filterUsage count and filterDesiredUsage alarm threshold. Threshold
  SET is cloud-only (samsungce.dustFilterAlarm); local read-only.
- clean_level / odor / dust / fine_dust (diagnostic sensors): /sensors/vs/0
  items[]. No unit advertised on the resource, so no device_class until a
  populated reading + unit is observed (don't-guess rule). SuperFineDust
  intentionally not modeled.
- software_version / firmware_version (diagnostic sensors):
  /information/vs/0 items[]. The href is globally ignored as identity
  plumbing; the AC registry drops that ignore so INFO is the sole cap on it.

Translations: en.json + nl.json (every-language-mirrors-english invariant).
Golden regression: regenerated the 8 AC fixtures + dehumidifier (reuses
AIR_FILTER) for the new state keys.

608 tests pass.
2026-07-27 14:43:07 +02:00
Marc Billow fa8f1b8675 Add cool-only global RAC support: WindFree, Auto mode, display light
Finishes PR #91's contribution (pedroperosin) with the requested review
changes applied, on our own branch:

- Preset resolution is now fully dynamic, read from each unit's own
  /mode/convenient/vs/0 supportedModes instead of a static per-model
  table -- any board's convenient modes (including WindFree's Nano/
  NanoSleep) surface without code changes. Unlabelled codes across
  existing fixtures (longwind, motionindirect, motiondirect, drycomfort)
  plus the two new WindFree ones are added to en.json/nl.json.
- 'Auto' now maps to HVACMode.AUTO instead of HEAT_COOL: these are
  single-setpoint "device decides" units, not two-setpoint heat+cool
  ones. 'Fan' is added alongside 'Wind' as a second FAN_ONLY spelling;
  a new _device_code_for_hvac() picks the code from the unit's own
  supportedModes since the flat map can't disambiguate two device codes
  mapping to one HA value.
- Detection gains a hyphenated '-RAC-' modelNum fallback (alongside the
  existing '_RAC_') for cool-only global RAC variants whose
  /otninformation/vs/0 ships no swVersionInfo block.
- Adds a display_light switch sourced from /mode/vs/0's opaque options
  blob (inverted Light_On/Light_Off token) for boards with no dedicated
  /light/vs/0 switch.

Write-path behavioural change (touches the path iterated on across
#9/#17/#27/#38/#54): power now targets the vendor /power/vs/0 instead of
the OCF /power/0, and _is_on() reads vendor-first. /power/0 is absent on
several known AC boards, so the previous OCF-first read/write pair could
report and act on stale state -- consistent with #53's "can turn on but
not off". Target temperature now picks its channel (OCF pair vs. vendor
items[]) based on which the unit actually reports, reading and writing
the same one.

The vendor temperature write and the new display-light write both carry
only the changed field(s), not the whole resource -- confirmed sufficient
on the wire, the device merges the rest itself. That requires the
coordinator's optimistic cache to do the same merge on the read side so a
setpoint change doesn't blank out current/min/max/unit for the settle
window: common.py gains merge_items_field() next to the existing
merge_options_field(), and async_send_command wires it in for any write
touching x.com.samsung.da.items.

New fixture/golden for the cool-only global RAC variant (TP1X_DA-AC-RAC-
01001, AI_RAC_GLOBAL_COOLONLY_3.0); display_light added to the goldens
for boards that gain the new options-based switch. Regenerated against
current main rather than copied from the original PR, since those
goldens had already shifted (current_temperature_c/humidity from issue
#75).
2026-07-27 05:00:06 +00:00
Marc Billow af00c2b938 Merge pull request #110 from mbillow/claude/device-support-issue-107-coffee
Add coffee-maker capabilities to the water purifier registry (issue #107)
2026-07-26 23:40:03 -05:00
Marc Billow 35775c3d4a Add coffee-maker capabilities to the water purifier registry (issue #107)
Some TP2X_WATERPURIFIER_20K units are coffee-capable and expose five
resources issue #90's original dump never had:
/favorite/coffee/vs/0, /favorite/hotwater/vs/0,
/brand/recipe/info/vs/0, /coffee/custom/recipe/vs/0,
/recipe/coffee/vs/0, and /recipe/coffee/deletion/vs/0.

Adds FAVORITE_HOTWATER (a switch + select pair on
/favorite/hotwater/vs/0, mirroring the existing FAVORITE_CAPACITY
pattern) and COFFEE (a switch + status sensor on
/favorite/coffee/vs/0). The remaining four hrefs are static
capability-advertisement blobs or empty on every dump seen so far --
no live "current recipe" or "current custom slot" field to expose --
so they're added to the ignored coverage list per the 'don't guess'
rule rather than modeled speculatively.

Confirmed against the issue #107 diagnostics dump with zero unbound
hrefs.
2026-07-27 04:19:19 +00:00