Marc Billow a7aea3764b feat(airconditioner): make absence/motion-detect enable switches writable
status on both /mds/absencepowersaving/vs/0 and
/option/motiondetectwind/stateful/vs/0 is a bare On/Off boolean, the same
shape already shipped writable elsewhere in this file (MUTE_ONCE,
AUTO_CLEAN, AIR_PURIFY) without a live-confirmed write either -- worst
case a wrong token no-ops. The paired mode selects (switchPowerSaveMode,
motion-detect modes) stay read-only: their behavioral effect on live HVAC
isn't inferable from the dump, same reasoning as ANOMALY_LOAD's mode field.