WA8000T reports no oneUiVersion and used the 'WA' consumer-model prefix, unmapped in _CONSUMER_PREFIX_TO_KEY (only WW/WD/WF/WV were covered), so it fell into the unknown-device-type fallback. Adding a bare 'WA' entry collided with the unrelated '_WAC_' (Window Air Conditioner, issue #87) board-family token: some devices report description == modelNum, so 'WAC' shows up as its own description segment and 'WAC'[:2] == 'WA' matched the new washer prefix before the more specific '_WAC_' modelNum check ever ran. Fixed by reordering for_device_by_model() to check board-family modelNum tokens first and the fuzzier 2-letter consumer-model-prefix scan only as a fallback, rather than patching the prefix matching itself (an earlier attempt -- requiring a digit immediately after the prefix -- broke issue #79's real DVE50A8800 case, which has no digit there either). Added a regression test pinning the WAC/WA disambiguation directly. Confirmed against the issue #106 diagnostics dump with zero unbound hrefs.
27 lines
501 B
JSON
27 lines
501 B
JSON
{
|
|
"state_keys": [
|
|
"alarm_code",
|
|
"child_lock",
|
|
"completion_minutes",
|
|
"cycle",
|
|
"cycle_active",
|
|
"delay_start_hours",
|
|
"detergent_low",
|
|
"diagnosis_status",
|
|
"drum_clean_cycles_remaining",
|
|
"energy_kwh",
|
|
"finish_time",
|
|
"firmware_update",
|
|
"job_beginning_status",
|
|
"machine_state",
|
|
"power_switch",
|
|
"progress",
|
|
"progress_percentage",
|
|
"remote_control",
|
|
"rinse_cycles",
|
|
"softener_low",
|
|
"spin_speed",
|
|
"wash_temperature"
|
|
]
|
|
}
|