Marc Billow 1abaad7f40 Fix issues found by an Opus review of the smartthings-local upgrade
An independent review of the last two commits' diff turned up five real
problems and one CI-breaking one. Fixed all of them:

- tests/test_coordinator_error_handling.py assigned directly onto
  coordinator instance attributes (coordinator._poll_once = dict), which
  `ty check custom_components tests` -- what CI actually runs, not the
  narrower `ty check custom_components` this branch had only been
  spot-checked against -- flags as invalid-assignment. Switched to
  monkeypatch.setattr, matching every other new test on this branch.

- coordinator.py's subdevice-enumeration failure comment claimed the
  probe "retries naturally next cycle." It doesn't: _run_discovery sets
  self._discovered = True unconditionally later in the same cycle, which
  is what gates the whole block, so a failure here is a first-and-only
  attempt, not a retried one -- a composite appliance's sibling
  subdevices are missing for the config entry's lifetime until reload.
  (A separate flag to retry wouldn't actually fix that either: every
  platform's async_setup_entry enumerates coordinator.bound exactly
  once, so a later-successful enumeration still couldn't add entities
  without a reload.) Corrected the comment and raised debug to warning,
  since the effect is silent and permanent otherwise.

- config_flow.py's new diagnostic-handshake fallback (_resolve_alert)
  was being called once per failing candidate, inside _handshake_and_read's
  scan loop -- contradicting _diagnostic_alert's own docstring ("only
  runs once every real candidate has already failed"). Two real costs:
  up to CLIENTHELLO_PROBE_TIMEOUT_S extra latency per failing port on
  the sweep-fallback path (several candidates), and -- more seriously --
  the diagnostic commits DTLS association state on each port it touches,
  which can make _probe_and_validate's own CertRejected re-mint retry
  (a fresh _handshake_and_read call against that same scan) time out
  against the very port it just polluted, per the RFC 6347 §4.2.8
  concern already documented elsewhere in this file. Moved to a new
  _diagnose_failures helper called once, after the loop, against the
  single best (confirmed-live) candidate.

- _resolve_alert also ignored the alert's level: ProbeResult.alert is
  set for a received alert of either severity, but only a fatal one (2)
  means the appliance broke off the handshake over it -- a warning
  (e.g. close_notify) was being read as a rejection reason. Older
  library exception text never had this ambiguity (OpenSSL only renders
  an exception for a fatal alert), so this was a bug the redaction
  fallback introduced. Now filters to level == 2.

- async_raw_read's new HomeAssistantError wrapper reported a translated
  error but left a confirmed-dead session installed, so every
  subsequent read/write would keep failing identically for up to the
  next full poll interval. Now closes the session on any non-TimeoutError
  failure, matching _poll_once's own posture.

- async_raw_write_sequence's verify_after fallback (vcode, vrep = 0, {})
  is indistinguishable from a real 4.04 by raw_code alone. Added a
  read_error field so a caller can tell "couldn't verify" from "the
  device said no."

Tests: 8 new/extended (once-not-per-port diagnostic count, alert-level
filtering, the warning log + permanent-loss framing, session-closing on
both async_raw_read and the verify_after path, read_error surfacing).
Full suite (1527 tests), ruff, ruff format, and -- critically --
`ty check custom_components tests` (the CI-matching invocation) all pass.
2026-08-14 18:43:44 +00:00
..