Marc Billow 5e2c23a62d Add device support for dual-cavity range TP1X_DA-KS-RANGE-0101X (issue #324)
This board (NE63T8751SG/AA-class) reports no /information/vs/0 at all --
the modelNum-based routing fallback has nothing to read -- so it fell
back to 'unknown' and lost the whole range registry (oven mode/setpoint/
door/connected, cooktop monitoring). /oic/d does carry oic.d.range,
though, so this is a routing fix, not a new capability: adds 'oic.d.range'
to _OIC_TYPE_TO_KEY.

The second oven cavity is a genuine Pattern A indexed subdevice at
/device/1 (issue #177's mechanism) -- once routing resolves the master to
the range registry, the same registry already applies to the subdevice's
canonical view and every href on both binds with zero gaps.

_discover_full gains an optional device_types param (default (), every
other fixture unaffected) so a fixture that can only route via /oic/d can
exercise the same subdevice-aware pipeline the other composite fixtures
already do.