Marc Billow 9d28b088cb laundry: cover a device that advertises cloud cycles it has never loaded
A survey of every laundry diagnostics dump attached to an issue turned up 14
devices, 4 of which carry cloud-course tokens. Two were already known; the
two new ones are both useful, and one contradicts something the
investigation write-up asserted.

A DW5000C dishwasher (issues #113/#123) advertises four downloaded programs
and carries no payload token for any of them. That is a shape the corpus
didn't have: the feature is not washer-only (DA_DW, not DA_WM), and a device
can name programs whose payloads have never been observed. The existing code
already handles it correctly -- nothing learnable, nothing offered, gap still
counted for the Repairs issue -- so this adds the fixture, golden, and tests
that keep it that way.

A second WW5000C (issues #259/#343, firmware _B048) holds the same saved
program as the first one's captured "Towels", and the two payloads differ at
exactly one byte: byte 3, 04 against 06. Everything else -- id, slot, all
four varying tag values, the whole tail -- is identical. So byte 3 is neither
a per-board constant nor a property of the program, and the doc's claim that
it is always 04 on this board was wrong.

That is also the strongest argument yet for learning payloads per device: a
catalog keyed on program id would have shipped one unit's byte 3 to the
other. Nothing changes in the implementation as a result -- it never had a
catalog -- but the reasoning is now backed by evidence rather than caution.

Also recorded: both WW5000C units advertise the byte-identical slot list
despite different firmware, so the program set looks factory- or
region-assigned rather than user-curated; and a sentinel's byte 2 equals the
selected course on one dump but not the other, so it stays unused.
2026-08-09 21:46:29 +00:00

261 lines
13 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# Laundry cloud "Download" cycles: solved, with one dead end
`registry/capabilities/laundry.py`'s cycle select offers a washer's
downloaded ("Download" / "Downloaded") programs alongside its ordinary
courses now, driven by the store in `cloudcourse.py` (issue #342). This file
records the byte-level work behind it, including a decode that fit one
device perfectly and collapsed on the second — the reason nothing in the
shipped code interprets a program payload at all.
Four devices in the corpus carry these tokens (a survey of every laundry
diagnostics dump attached to an issue turned up 14 devices; the other 10 have
no cloud tokens at all, so this is a minority feature):
| dump | model | slots advertised | payloads seen | blob width |
| --- | --- | --- | --- | --- |
| `washer_ww5000c_cloud` | WW5000C `_B06C`, `DA_WM_TP1_21_COMMON`, Table_02 | 9 | 2 | 20 bytes |
| `washer_wa55a7700av` | WA55A7700AV, `DA_WM_TP1_21_COMMON`, Table_02 | 2 | 1 | 16 bytes |
| `dishwasher_dw5000c_cloud` | DW5000C, `DA_DW_TP1_21_COMMON` | 4 | **0** | — |
| (not fixtured) | WW5000C `_B048`, issues #259/#343, Table_02 | 9 | 1 | 20 bytes |
Three things follow immediately from that table:
- **It isn't washer-only.** The DW5000C is a `DA_DW_` dishwasher.
- **A device can advertise programs it has never loaded.** The DW5000C names
four slots and carries no `CloudCourse_`/`OneTimeCloudCourse_` token at
all. Nothing about it is learnable until its owner runs one, which is
exactly the situation the Repairs issue exists to explain.
- **Both WW5000C units advertise the byte-identical slot list**
(`0A5C286B2D0C55301A`, same nine slots in the same order) despite different
firmware builds. Either the set is a factory/regional default rather than
something each owner curates, or the two dumps share an owner — unresolved,
but worth knowing before assuming a user picked their own programs.
## The three tokens
All on `/course/vs/0`'s `x.com.samsung.da.options` array, same
prefix-match/replace merge as every other token there.
- `CloudExtraCourse_<slot><slot>…` — the device's own list of downloaded
program slots, one byte each. The cloud counterpart of `EditCourseList_`.
- `CloudCourse_<blob>` — the persisted default program.
- `OneTimeCloudCourse_<blob>` — a this-run-only override.
### `CloudExtraCourse_` is an enumeration, and byte 2 of a blob is its slot
The WW5000C reports `CloudExtraCourse_0A5C286B2D0C55301A` — nine bytes for
its nine downloaded programs. Byte 2 of each of the nine blobs its owner
captured is exactly one of those nine, no repeats, sets equal:
```
blob byte2 program
00 21 55 04 49 28 4D 13 4A A0 4C 00 … 55 Sports
00 20 28 04 49 00 4D 00 4A B8 4C 00 … 28 Spin only
00 02 5C 04 49 28 4D 13 4A B0 4C 00 … 5C Outdoor
00 1F 6B 04 49 28 4D 13 4A A0 4C 00 … 6B Jeans
00 2E 2D 04 49 30 4D 12 4A A0 4C 00 … 2D Super quiet
00 2F 0C 04 49 58 4D 14 4A B8 4C 00 … 0C Baby care intensive
00 0D 30 04 49 30 4D 12 4A B8 4C 00 … 30 Cloudy heaven
00 30 1A 04 49 28 4D 12 4A A0 4C 00 … 1A Shirts
00 04 0A 04 49 40 4D 13 4A B8 4C 00 … 0A Towels
CloudExtraCourse_ 0A 5C 28 6B 2D 0C 55 30 1A
```
Confirmed independently on the WA55A7700AV: `CloudExtraCourse_5958`, and its
`CloudCourse` blob `00 1C 59 05 …` has byte 2 = `59`. Its
`OneTimeCloudCourse` is `FF FF 01 …` — byte 2 = `01`, which is *not* an
advertised slot, and the `FFFF` prefix marks it as "nothing loaded" rather
than naming a program. That sentinel is why `cloudcourse.is_loaded` exists.
This is what makes "3 of 9 discovered" answerable, and it is why no catalog
of program ids is hardcoded anywhere: the appliance already knows which
programs it has.
## Writing: the two-token rule
Confirmed on hardware by the issue #342 reporter. Writing
`OneTimeCloudCourse_<blob>` alone while some other course is selected is
accepted at the protocol level (no error) and then silently ignored by the
machine. It takes effect only when the same write also switches `Course_` to
the Download course — which is what `laundry._cloud_cycle_write` does, and
the only two-token options write in the codebase:
```yaml
x.com.samsung.da.options:
- Course_87
- OneTimeCloudCourse_001F6B0449284D134AA04C0035F004F005F0AC00
```
`CloudCourse_` was separately confirmed writable on its own: set while on
Download it changes the running program; set from another course it becomes
what gets preselected the next time Download is chosen. The integration
doesn't write it today — a "default download cycle" control is a possible
follow-up, deliberately left out of the first pass.
### There is no single "Download" course code
The WW5000C's Download is `Course_87`; the WA55A7700AV's is `17`
("Downloaded" in `washer_cycle_table_02`). **Same course table, different
code.** Any per-table lookup of "the Download code" would have been wrong on
one of the only two devices available to check it against, which is why the
code is learned by observation and confirmed by the user in the options flow
instead of tabled.
The observation signal is "whatever `Course_` reads while a non-sentinel
`OneTimeCloudCourse_` is loaded." That is a *candidate*, never applied
directly: tokens in this array are replaced by prefix and never evicted, so
a stale program token outlives the run it belonged to and can be reported
next to an unrelated local course. Acting on that unconfirmed would start
the wrong wash cycle.
## The dead end: bytes 5/7/9 do not decode portably
With the nine WW5000C programs and their app-reported settings side by side,
three of the varying bytes fit perfectly:
| byte | meaning | formula | fit |
| --- | --- | --- | --- |
| 5 | wash temperature | `(b - 0x10) / 0.8` °C, `0x00` = n/a | 9/9 |
| 7 | rinse count | `b - 0x10`, `0x00` = off | 9/9 |
| 9 | spin level | `(b - 0x90) / 8` | 9/9 |
Nine for nine, including the internally consistent case: "Spin only" is the
only program with `0x00` in *both* byte 5 and byte 7, matching a cycle that
skips washing entirely while still reporting a spin level.
It does not survive the second device. Against the WA55A7700AV's
`CloudCourse` blob `00 1C 59 05 49 16 4D 11 4A 22 4C 20 37 F0 AC 22`:
- temperature: `(0x16 - 0x10) / 0.8` = **7.5 °C**
- spin: `(0x22 - 0x90) / 8` = **negative**
- rinse: `0x11 - 0x10` = 1 — the only plausible one
### What *does* survive is the grammar
The two boards' payloads are different lengths (20 vs 16 bytes) but not a
different format — same header, same leading fields, two fewer optional
trailing ones:
```
WW5000C 00 | 2155 | 04 | 49:28 4D:13 4A:A0 4C:00 | 35:F0 04:F0 05:F0 | AC:00
WA55 00 | 1C59 | 05 | 49:16 4D:11 4A:22 4C:20 | 37:F0 | AC:22
```
- `00`, then the 2-byte program id, then one byte (`04` vs `05`) — identical
layout on both.
- Then a tag/value stream whose **first four tags are the same, in the same
order, at the same offsets**: `49`, `4D`, `4A`, `4C`. These are exactly the
four whose values vary per program.
- Then a fixed tail, terminated on both by an `AC:<value>` pair. The entire
width difference is two trailing pairs the WA55 doesn't carry.
The tail is not program data. Across all nine WW5000C programs bytes 12–19
are byte-identical — every trailing pair carries value `F0` except the `AC`
terminator, and `35` vs `37` looks like a board or profile marker rather than
a field. (It is not a field count either: the board with the *higher* leading
byte has *fewer* pairs.)
### Byte 3 is not part of a program's identity
Worth its own heading, because it is the single strongest argument against
ever shipping a table of payloads. The second WW5000C (issues #259/#343,
firmware `_B048`) has its saved `CloudCourse` set to the same program as the
first one's "Towels" capture — and the two payloads differ at exactly one
byte:
```
_B06C "Towels" 00 04 0A 04 49 40 4D 13 4A B8 4C 00 35 F0 04 F0 05 F0 AC 00
_B048 CloudCourse 00 04 0A 06 49 40 4D 13 4A B8 4C 00 35 F0 04 F0 05 F0 AC 00
^^
```
Same program id, same slot, same values on all four varying tags, same tail.
Only byte 3 moves, `04` → `06`. So it is neither a per-board constant (both
are WW5000C) nor a property of the program (identical in every other
respect) — most likely a download revision or sequence counter.
A hardcoded catalog keyed on program id would therefore have shipped one
unit's byte 3 to the other unit. Whether the appliance would reject that, or
accept it and do something unintended, is untested and does not need to be:
every payload is learned from the device it will be replayed to.
### Sentinels
The `FFFF` "nothing loaded" payload takes its board's own width (16 bytes on
the WA55, 20 on the WW5000C `_B048`) and always carries byte 3 = `00`. Its
byte 2 is *not* reliably meaningful: it equals the currently selected course
on the WA55 (`01`, on `Course_01`) and does not on the `_B048` (`1B`, on
`Course_1C`). Nothing keys off it — a sentinel is rejected on its `FFFF`
prefix, and its byte 2 is not an advertised slot in either dump anyway.
So the payload is tag/value, not fixed offsets — but knowing the grammar
doesn't recover the values. The same four tags carry non-overlapping ranges
between the two boards:
| tag | WW5000C (9 programs) | WA55 |
| --- | --- | --- |
| `49` | `00, 28, 30, 40, 58` | `16` |
| `4D` | `00, 12, 13, 14` | `11` |
| `4A` | `A0, B0, B8` | `22` |
| `4C` | `00` (all nine) | `20` |
Same field, board-specific encoding. Decoding it properly needs a third
device; one device's fit is a coincidence-shaped hypothesis, not a format.
**A trap for whoever picks this up:** the WA55's `/washer/vs/0` reads
Warm / High / 1, which looks like it could confirm a decode of that unit's
`CloudCourse`. It can't — that appliance is sitting on `Course_01` (Normal),
not on its cloud course, so those values describe the local cycle it has
selected, not the saved cloud program. A cross-check like this is only
evidence when the machine is actually loaded with the program being decoded.
So the shipped code never interprets a payload: a blob is recorded whole and
replayed byte-for-byte, exactly as the device reported it, and never
decomposed or rebuilt. The read-only "loaded program's temperature/spin"
sensors this decode would have enabled were dropped for the same reason.
## What is deliberately not done
- **No hardcoded program catalog.** Blobs are cloud-assigned per
account/region. One owner's captured payload is not evidence about anyone
else's appliance, and a table of them would offer options that write
another household's wash settings.
- **No invented names.** The appliance reports an opaque slot id and nothing
else. Names come from the user in the options flow, the same rule that
stops an unrecognized local course code from getting a made-up English
label (PR #251 review).
- **No blob synthesis.** Even with the byte 5/7/9 decode in hand, nothing
builds a payload from parts — the device was never tested with one, and a
fabricated blob is an untested write to a wash cycle.
## Open questions for the next dump
1. Does `OneTimeCloudCourse_` clear itself when a cycle finishes, or when the
course changes? Behavior suggests the appliance falls back to
`CloudCourse_` when Download is re-entered, but the token's own lifecycle
is unconfirmed. `laundry.cloud_current` is written to be correct either
way.
2. What does byte 1 mean? It is distinct per program and *sometimes*
coincides with a plausible local course code for that program (`2E` Baby
Care for "Baby care intensive", `30` Cloudy Day for "Cloudy heaven") and
sometimes doesn't (`21` Colors for "Sports"). Probably a base-course
reference; not reliable enough to use.
3. What does byte 3 count? It moves between two units holding the identical
program (`04` vs `06`) and is `00` on every sentinel. A revision or
download counter is the obvious guess; a dump taken before and after
re-downloading the same program would confirm it.
4. **The value encoding is still open, and a third *washer* won't
necessarily settle it.** The survey found one, but its saved program is a
duplicate of one already captured, so it adds no new tag values. What is
actually needed is a dump from a board whose `/washer/vs/0` speaks in
named levels (Cold/Warm/Hot, Low/High) *while that unit is sitting on a
downloaded program* — then the payload's `49`/`4A` values can be read
against settings that describe the same program. The WA55 is such a
board but was captured on a local course, which is why it can't be used
(see the trap above).
5. The DW5000C's four slots (`8E 8D 8F 02`) are in the same numeric range as
dishwasher course codes (its selected course is `86`), unlike the
washers' slots. One payload from that machine would show whether slot ids
are drawn from the course-code space on some boards.