OCF rt is a schema category shared by many unrelated resources. The stable unique resource address is the href. Update Capability, discovery, common capabilities, tests, and plan accordingly.
115 lines
3.7 KiB
Python
115 lines
3.7 KiB
Python
"""Capabilities shared across multiple appliance families.
|
|
|
|
Each capability is keyed on the stable OCF resource href (not rt), verified
|
|
against live device dumps:
|
|
/kidslock/vs/0 -> x.com.samsung.da.kidsLock
|
|
/remotectrl/vs/0 -> x.com.samsung.da.remoteControlEnabled
|
|
/power/vs/0 -> x.com.samsung.da.power
|
|
/alarms/vs/0 -> x.com.samsung.da.items
|
|
/energy/consumption/vs/0 -> x.com.samsung.da.instantaneousPower / cumulativePower
|
|
/water/consumption/vs/0 -> x.com.samsung.da.cumulativeWater
|
|
/filter/waterfilter/vs/0 -> x.com.samsung.da.filterUsage / filterStatus
|
|
"""
|
|
from ..capability import Capability
|
|
from ..entities import BinarySensorDesc, SensorDesc, SwitchDesc
|
|
|
|
|
|
def _num(v):
|
|
try:
|
|
return float(v)
|
|
except (TypeError, ValueError):
|
|
return None
|
|
|
|
|
|
def _clamp_power(v):
|
|
n = _num(v)
|
|
return 0.0 if (n is not None and n < 0) else n
|
|
|
|
|
|
def _wh_to_kwh(v):
|
|
n = _num(v)
|
|
return round(n / 1000.0, 2) if n is not None else None
|
|
|
|
|
|
def _ml_to_l(v):
|
|
n = _num(v)
|
|
return round(n / 1000.0, 1) if n is not None else None
|
|
|
|
|
|
def _last_alarm_code(items):
|
|
if items and isinstance(items, list):
|
|
return items[-1].get('x.com.samsung.da.code')
|
|
return None
|
|
|
|
|
|
KIDS_LOCK = Capability(
|
|
href='/kidslock/vs/0',
|
|
entities=(
|
|
BinarySensorDesc(key='child_lock', field='x.com.samsung.da.kidsLock',
|
|
name='Child lock', device_class='lock',
|
|
value_fn=lambda v: v != 'Ready'),
|
|
),
|
|
)
|
|
|
|
REMOTE_CONTROL = Capability(
|
|
href='/remotectrl/vs/0',
|
|
entities=(
|
|
BinarySensorDesc(key='remote_control',
|
|
field='x.com.samsung.da.remoteControlEnabled',
|
|
name='Remote control', device_class='connectivity',
|
|
value_fn=lambda v: str(v).lower() == 'true'),
|
|
),
|
|
)
|
|
|
|
POWER = Capability(
|
|
href='/power/vs/0',
|
|
entities=(
|
|
SwitchDesc(key='power_switch', field='x.com.samsung.da.power',
|
|
name='Power',
|
|
value_fn=lambda v: v == 'On',
|
|
write_fn=lambda p, rep: (['/power/vs/0'], {'x.com.samsung.da.power': 'On' if p else 'Off'})),
|
|
),
|
|
)
|
|
|
|
ALARMS = Capability(
|
|
href='/alarms/vs/0',
|
|
entities=(
|
|
SensorDesc(key='alarm_code', field='x.com.samsung.da.items',
|
|
name='Alarm code', icon='mdi:alert',
|
|
entity_category='diagnostic', value_fn=_last_alarm_code),
|
|
),
|
|
)
|
|
|
|
ENERGY_METER = Capability(
|
|
href='/energy/consumption/vs/0',
|
|
entities=(
|
|
SensorDesc(key='power_watts', field='x.com.samsung.da.instantaneousPower',
|
|
name='Power', device_class='power', state_class='measurement',
|
|
unit='W', value_fn=_clamp_power),
|
|
SensorDesc(key='energy_kwh', field='x.com.samsung.da.cumulativePower',
|
|
name='Energy', device_class='energy',
|
|
state_class='total_increasing', unit='kWh', value_fn=_wh_to_kwh),
|
|
),
|
|
)
|
|
|
|
WATER_METER = Capability(
|
|
href='/water/consumption/vs/0',
|
|
entities=(
|
|
SensorDesc(key='water_liters', field='x.com.samsung.da.cumulativeWater',
|
|
name='Water consumption', device_class='water',
|
|
state_class='total_increasing', unit='L', icon='mdi:water',
|
|
value_fn=_ml_to_l),
|
|
),
|
|
)
|
|
|
|
WATER_FILTER = Capability(
|
|
href='/filter/waterfilter/vs/0',
|
|
entities=(
|
|
SensorDesc(key='filter_usage', field='x.com.samsung.da.filterUsage',
|
|
name='Filter usage', unit='%', state_class='measurement',
|
|
icon='mdi:filter'),
|
|
SensorDesc(key='filter_status', field='x.com.samsung.da.filterStatus',
|
|
name='Filter status', icon='mdi:filter-check'),
|
|
),
|
|
)
|