feat(airconditioner): fan, swing, presets and option-token settings on ARTIK051 boards
This board generation predates every AC dump the registry was built from and differs in three ways, all handled here behind presence checks so no other family's behaviour changes: * No /wind/* resources at all. Fan speed and vane direction share a single /airflow/vs/0 resource, whose speedLevel uses the same 0-4 scale as _DEVICE_TO_FAN and whose direction uses the same codes as _DEVICE_TO_SWING, so the existing maps are reused rather than duplicated. The resource reports no supportedModes, so the full scale is offered. * No /mode/convenient/vs/0. The convenient-mode preset is a Comode_* token in /mode/vs/0's options, synthesised into a convenient-shaped rep so the existing dynamic preset resolver keeps working unchanged. Codes were learned by driving one unit through its cloud integration and reading the token back each time: Nano is what the app calls WindFree, plus Quiet/Comfort/2Step/ Speed (Fast Turbo) and Off. * Several settings that newer boards expose as dedicated resources are options tokens here: SPI, auto clean, air monitoring, beep volume, Good Sleep, outdoor temperature and filter time. Writes reuse option_write's single-token merge, the same mechanism the display light already uses on this href. Newer families carry some of the same tokens *alongside* dedicated resources for those settings, so the token entities are gated on this generation's resource shape (/airflow/vs/0 present, /wind/strength/vs/0 absent -- the same test the climate entity's fan/swing fallback uses, so the two can never disagree). Without that gate they duplicated auto clean on TP1X/TP2X boards and applied a calibration from this board to theirs. Two calibrations, both from hardware rather than from the token names: OutdoorTemp is offset by 55 (token 75 against a 20.3 C outdoor thermometer in the same install, token 74 against a 19.4 C forecast; Fahrenheit fits far worse), and FilterTime is tenths of an hour (token 1710 while the official Samsung app displayed "171 hours 0 minutes" for the same unit's filter). Whether filter time counts up or down is deliberately not claimed: it was seen rising while the unit ran, which contradicts the app's "remaining" wording. Humidity now falls back to the plain x.com.samsung.da.humidity field where fivepercentHumidity is absent, still as one entity rather than two, and 0 reads as "not measuring" rather than 0% -- on this board the field only carries a reading (51%, matching the same unit's cloud integration) while Air monitoring is on, which the unit switches back off by itself after about a minute. Fan, swing, preset, SPI and beep-volume writes were confirmed by read-back on hardware. Good Sleep's upper bound is a guess (only 0 has been observed), and /airflow/0 -- the OCF-standard mirror of the vendor resource -- is ignored rather than modelled, since air_purifier.py found the opposite reliability ordering between these two hrefs on its own family. Refs #136
This commit is contained in:
@@ -50,6 +50,7 @@ from .registry.capabilities.airconditioner import (
|
||||
HREF_WIND_DIRECTION as WIND_DIRECTION_HREF,
|
||||
HREF_WIND_OSCILLATION as WIND_OSCILLATION_HREF,
|
||||
HREF_CONVENIENT as CONVENIENT_HREF,
|
||||
HREF_AIRFLOW as AIRFLOW_HREF,
|
||||
)
|
||||
from .registry.capabilities.common import normalize_temp_unit
|
||||
|
||||
@@ -228,8 +229,45 @@ class LocalThingsClimate(LocalThingsEntity, ClimateEntity):
|
||||
|
||||
# -- resource helpers ---------------------------------------------------
|
||||
|
||||
# Preset codes on legacy ARTIK051 boards, learned by driving the same unit
|
||||
# through its cloud integration and reading the local token back each time:
|
||||
# Nano=windFree, Quiet, Comfort, 2Step, Speed=Fast Turbo, Off=none.
|
||||
_LEGACY_PRESET_CODES = ('Off', 'Nano', 'Quiet', 'Comfort', '2Step', 'Speed')
|
||||
|
||||
def _legacy_convenient(self) -> dict:
|
||||
"""A /mode/convenient/vs/0-shaped rep built from the Comode_* token in
|
||||
/mode/vs/0's options, for boards that have no convenient resource."""
|
||||
options = (self.coordinator.resource(MODE_HREF) or {}).get(
|
||||
'x.com.samsung.da.options') or []
|
||||
for option in options:
|
||||
if isinstance(option, str) and option.startswith('Comode_'):
|
||||
return {_MODES_FIELD: [option.split('_', 1)[1]],
|
||||
_SUPPORTED_FIELD: list(self._LEGACY_PRESET_CODES)}
|
||||
return {}
|
||||
|
||||
def _legacy_airflow(self) -> dict:
|
||||
"""The /airflow/vs/0 rep, but only when it is the fan/swing channel to
|
||||
use -- i.e. this board has no /wind/strength/vs/0."""
|
||||
if self.coordinator.resource(WIND_STRENGTH_HREF):
|
||||
return {}
|
||||
return self.coordinator.resource(AIRFLOW_HREF) or {}
|
||||
|
||||
def _legacy_preset(self) -> bool:
|
||||
"""Whether presets come from the Comode_* token rather than a resource.
|
||||
|
||||
Gated on the same board test as _legacy_airflow, not on the convenient
|
||||
rep being empty alone: newer boards carry Comode tokens too, so a
|
||||
momentarily empty /mode/convenient/vs/0 there must not silently switch
|
||||
the preset read (and write) over to the token path.
|
||||
"""
|
||||
return (not self.coordinator.resource(CONVENIENT_HREF)
|
||||
and bool(self._legacy_airflow()))
|
||||
|
||||
def _rep(self, href: str) -> dict:
|
||||
return self.coordinator.resource(href) or {}
|
||||
rep = self.coordinator.resource(href) or {}
|
||||
if not rep and href == CONVENIENT_HREF and self._legacy_airflow():
|
||||
return self._legacy_convenient()
|
||||
return rep
|
||||
|
||||
def _is_on(self) -> bool:
|
||||
# Prefer the vendor /power/vs/0 (present on every observed board and
|
||||
@@ -373,10 +411,16 @@ class LocalThingsClimate(LocalThingsEntity, ClimateEntity):
|
||||
|
||||
@property
|
||||
def fan_mode(self):
|
||||
airflow = self._legacy_airflow()
|
||||
if airflow:
|
||||
return _DEVICE_TO_FAN.get(str(airflow.get('x.com.samsung.da.speedLevel')))
|
||||
return self._read_mode(WIND_STRENGTH_HREF, _DEVICE_TO_FAN)
|
||||
|
||||
@property
|
||||
def fan_modes(self) -> list[str]:
|
||||
if self._legacy_airflow():
|
||||
# This resource carries no supportedModes, so the full scale is offered.
|
||||
return list(_DEVICE_TO_FAN.values())
|
||||
return self._read_modes(WIND_STRENGTH_HREF, _DEVICE_TO_FAN)
|
||||
|
||||
def _swing_via_direction(self) -> bool:
|
||||
@@ -387,12 +431,17 @@ class LocalThingsClimate(LocalThingsEntity, ClimateEntity):
|
||||
|
||||
@property
|
||||
def swing_mode(self):
|
||||
airflow = self._legacy_airflow()
|
||||
if airflow:
|
||||
return _DEVICE_TO_SWING.get(airflow.get('x.com.samsung.da.direction'))
|
||||
if self._swing_via_direction():
|
||||
return self._read_mode(WIND_DIRECTION_HREF, _DEVICE_TO_SWING)
|
||||
return _oscillation_swing(self._rep(WIND_OSCILLATION_HREF))
|
||||
|
||||
@property
|
||||
def swing_modes(self) -> list[str]:
|
||||
if self._legacy_airflow():
|
||||
return list(_SWING_TO_DEVICE.keys())
|
||||
if self._swing_via_direction():
|
||||
return self._read_modes(WIND_DIRECTION_HREF, _DEVICE_TO_SWING)
|
||||
if self._rep(WIND_OSCILLATION_HREF):
|
||||
@@ -468,9 +517,21 @@ class LocalThingsClimate(LocalThingsEntity, ClimateEntity):
|
||||
await self.coordinator.async_send_command(self._bound, (kind, device))
|
||||
|
||||
async def async_set_fan_mode(self, fan_mode: str) -> None:
|
||||
if self._legacy_airflow():
|
||||
level = _FAN_TO_DEVICE.get(fan_mode)
|
||||
if level is not None:
|
||||
await self.coordinator.async_send_command(
|
||||
self._bound, ('fan_legacy', level))
|
||||
return
|
||||
await self._set_mapped('fan', _FAN_TO_DEVICE, fan_mode)
|
||||
|
||||
async def async_set_swing_mode(self, swing_mode: str) -> None:
|
||||
if self._legacy_airflow():
|
||||
code = _SWING_TO_DEVICE.get(swing_mode)
|
||||
if code is not None:
|
||||
await self.coordinator.async_send_command(
|
||||
self._bound, ('swing_legacy', code))
|
||||
return
|
||||
if self._swing_via_direction():
|
||||
await self._set_mapped('swing', _SWING_TO_DEVICE, swing_mode)
|
||||
return
|
||||
@@ -489,5 +550,6 @@ class LocalThingsClimate(LocalThingsEntity, ClimateEntity):
|
||||
# a fixed transform of the HA value -- e.g. 'NanoSleep' -> 'nanosleep').
|
||||
for code in self._supported(CONVENIENT_HREF):
|
||||
if _preset_to_ha(code) == preset_mode:
|
||||
await self.coordinator.async_send_command(self._bound, ('preset', code))
|
||||
kind = 'preset_legacy' if self._legacy_preset() else 'preset'
|
||||
await self.coordinator.async_send_command(self._bound, (kind, code))
|
||||
return
|
||||
|
||||
@@ -15,7 +15,9 @@ different schema (see capabilities/__init__.py). They live only in the AC
|
||||
by_type registry.
|
||||
"""
|
||||
from ..capability import Capability
|
||||
from ..entities import BinarySensorDesc, ClimateDesc, SensorDesc, SwitchDesc
|
||||
from ..entities import (
|
||||
BinarySensorDesc, ClimateDesc, NumberDesc, SensorDesc, SwitchDesc,
|
||||
)
|
||||
from .common import filter_usage_percent, normalize_temp_unit
|
||||
from .laundry import option_write
|
||||
|
||||
@@ -43,11 +45,18 @@ HREF_WIND_DIRECTION = '/wind/direction/vs/0' # swing_mode
|
||||
HREF_WIND_OSCILLATION = '/wind/oscillation/vs/0' # swing_mode fallback
|
||||
HREF_CONVENIENT = '/mode/convenient/vs/0' # preset_mode
|
||||
HREF_TEMPS_VS = '/temperatures/vs/0' # vendor temp fallback (items[] array)
|
||||
# Legacy ARTIK051 boards (ARTIK051_KRAC_18K, issue #136) carry no /wind/* resources
|
||||
# at all: fan speed and vane direction sit together in this one resource, as
|
||||
# x.com.samsung.da.speedLevel (the same 0-4 scale as _DEVICE_TO_FAN) and
|
||||
# x.com.samsung.da.direction (the same codes as _DEVICE_TO_SWING). Their
|
||||
# convenient-mode preset is a Comode_* token in /mode/vs/0's options instead of a
|
||||
# resource of its own -- see climate.py's _legacy_airflow/_legacy_convenient.
|
||||
HREF_AIRFLOW = '/airflow/vs/0' # legacy fan_mode + swing_mode
|
||||
|
||||
CLIMATE_CONSUMED_HREFS = [
|
||||
HREF_POWER, HREF_POWER_VS, HREF_TEMP_CURRENT, HREF_TEMP_DESIRED,
|
||||
HREF_TEMP_CONTROL, HREF_TEMPS_VS, HREF_WIND_STRENGTH, HREF_WIND_DIRECTION,
|
||||
HREF_WIND_OSCILLATION, HREF_CONVENIENT,
|
||||
HREF_WIND_OSCILLATION, HREF_CONVENIENT, HREF_AIRFLOW,
|
||||
]
|
||||
|
||||
|
||||
@@ -127,6 +136,91 @@ def _display_light_write(payload, rep, href=None):
|
||||
{'x.com.samsung.da.options': option_write('Light', token)})
|
||||
|
||||
|
||||
# ---------------------------------------------------------------------------
|
||||
# Legacy ARTIK051 boards keep several settings that newer boards expose as their
|
||||
# own resources (/option/*, /electriccurrent/vs/0, ...) as `<Prefix>_<value>`
|
||||
# tokens inside /mode/vs/0's options blob instead. Reads pull the token apart;
|
||||
# writes reuse option_write's single-token merge, exactly like the display light.
|
||||
# ---------------------------------------------------------------------------
|
||||
|
||||
|
||||
def _option_token(rep, prefix):
|
||||
"""Value part of a `<prefix>_<value>` token in /mode/vs/0's options."""
|
||||
for option in _mode_options(rep):
|
||||
if isinstance(option, str) and option.startswith(prefix + '_'):
|
||||
return option.split('_', 1)[1]
|
||||
return None
|
||||
|
||||
|
||||
def _is_legacy_board(resources):
|
||||
"""True for the board generation whose airflow lives in /airflow/vs/0.
|
||||
|
||||
Newer families carry several of the same option tokens (Volume, Sleep,
|
||||
OutdoorTemp, Autoclean) *alongside* dedicated resources for those settings,
|
||||
so an ungated token entity would either duplicate an existing one or apply a
|
||||
scale calibrated elsewhere. Every AC dump on record has one shape or the
|
||||
other: /airflow/vs/0 with no /wind/* at all, or /wind/strength/vs/0 with no
|
||||
/airflow/vs/0. Same test as climate.py's _legacy_airflow(), so the entities
|
||||
below and the climate entity can never disagree about the generation.
|
||||
"""
|
||||
return ('/airflow/vs/0' in resources
|
||||
and '/wind/strength/vs/0' not in resources)
|
||||
|
||||
|
||||
def _has_option_token(prefix):
|
||||
return lambda rep, resources: (
|
||||
_is_legacy_board(resources) and _option_token(rep, prefix) is not None)
|
||||
|
||||
|
||||
def _option_token_on(prefix):
|
||||
return lambda rep: _option_token(rep, prefix) == 'On'
|
||||
|
||||
|
||||
def _option_token_num(prefix, offset=0, divisor=1):
|
||||
def read(rep):
|
||||
raw = _option_token(rep, prefix)
|
||||
try:
|
||||
return (float(raw) - offset) / divisor
|
||||
except (TypeError, ValueError):
|
||||
return None
|
||||
return read
|
||||
|
||||
|
||||
def _option_switch_write(prefix):
|
||||
def write(payload, rep, href=None):
|
||||
return (['mode', 'vs', '0'],
|
||||
{'x.com.samsung.da.options': option_write(prefix, payload)})
|
||||
return write
|
||||
|
||||
|
||||
def _option_number_write(prefix):
|
||||
def write(payload, rep, href=None):
|
||||
return (['mode', 'vs', '0'],
|
||||
{'x.com.samsung.da.options':
|
||||
option_write(prefix, str(int(round(float(payload)))))})
|
||||
return write
|
||||
|
||||
|
||||
def _humidity(rep):
|
||||
"""Relative humidity, preferring the 5%-rounded field where it exists.
|
||||
|
||||
ARTIK051 boards have no fivepercentHumidity field at all and report the
|
||||
plain x.com.samsung.da.humidity instead -- and only populate it while the
|
||||
Air monitoring option is on: the unit measures for roughly half a minute
|
||||
(51% observed, matching what the same unit's cloud integration reported at
|
||||
that moment), then zeroes the field and switches Air monitoring back off by
|
||||
itself. So 0 reads as "not measuring" and is reported as unknown rather than
|
||||
as 0% humidity, which would poison long-term history -- which is also why
|
||||
the boards that do have fivepercentHumidity read a permanent 0 here.
|
||||
"""
|
||||
for field in ('x.com.samsung.da.fivepercentHumidity',
|
||||
'x.com.samsung.da.humidity'):
|
||||
if field in rep:
|
||||
value = _num(rep[field])
|
||||
return value if value else None
|
||||
return None
|
||||
|
||||
|
||||
def _climate_write(payload, rep, href=None):
|
||||
"""Map a (kind, value) command from the climate platform to the
|
||||
(path_segs, body) for that one sub-write. `value` is already the raw device
|
||||
@@ -180,6 +274,16 @@ def _climate_write(payload, rep, href=None):
|
||||
'vertical': 'Swing' if value in ('vertical', 'both') else 'Fix',
|
||||
'horizontal': 'Swing' if value in ('horizontal', 'both') else 'Fix',
|
||||
})
|
||||
if kind == 'fan_legacy':
|
||||
return (['airflow', 'vs', '0'],
|
||||
{'x.com.samsung.da.speedLevel': str(value)})
|
||||
if kind == 'swing_legacy':
|
||||
return (['airflow', 'vs', '0'],
|
||||
{'x.com.samsung.da.direction': value})
|
||||
if kind == 'preset_legacy':
|
||||
# Single-token options merge, same mechanism as _display_light_write.
|
||||
return (['mode', 'vs', '0'],
|
||||
{'x.com.samsung.da.options': option_write('Comode', value)})
|
||||
if kind == 'preset':
|
||||
return (['mode', 'convenient', 'vs', '0'], {'x.com.samsung.da.modes': value})
|
||||
return None
|
||||
@@ -204,6 +308,58 @@ CLIMATE = Capability(
|
||||
exists_fn=_has_display_light_option,
|
||||
write_fn=_display_light_write,
|
||||
icon='mdi:led-on', entity_category='config'),
|
||||
# Settings that this board generation keeps as options[] tokens.
|
||||
SwitchDesc(key='spi', rep_fn=_option_token_on('Spi'),
|
||||
exists_fn=_has_option_token('Spi'),
|
||||
write_fn=_option_switch_write('Spi'),
|
||||
icon='mdi:air-purifier', entity_category='config'),
|
||||
# Shares AUTO_CLEAN's catalog entry rather than duplicating it: same
|
||||
# feature, different board generation (that one is a /option/autoclean/
|
||||
# vs/0 field, absent here). Distinct key, so nothing collides if some
|
||||
# future board ever reported both.
|
||||
SwitchDesc(key='auto_clean_legacy', translation_key='auto_clean',
|
||||
rep_fn=_option_token_on('Autoclean'),
|
||||
exists_fn=_has_option_token('Autoclean'),
|
||||
write_fn=_option_switch_write('Autoclean'),
|
||||
icon='mdi:fan-auto', entity_category='config'),
|
||||
SwitchDesc(key='air_monitoring', rep_fn=_option_token_on('AirMonitoring'),
|
||||
exists_fn=_has_option_token('AirMonitoring'),
|
||||
write_fn=_option_switch_write('AirMonitoring'),
|
||||
icon='mdi:air-filter', entity_category='config'),
|
||||
NumberDesc(key='buzzer_volume', rep_fn=_option_token_num('Volume'),
|
||||
exists_fn=_has_option_token('Volume'),
|
||||
write_fn=_option_number_write('Volume'),
|
||||
native_min=0, native_max=100, step=10,
|
||||
icon='mdi:volume-high', entity_category='config'),
|
||||
# "Good Sleep" timer. 0 = off; the upper bound is a guess (the token
|
||||
# carries no range hint and only 0 has been observed on hardware), so a
|
||||
# write above 0 is unverified.
|
||||
NumberDesc(key='good_sleep', rep_fn=_option_token_num('Sleep'),
|
||||
exists_fn=_has_option_token('Sleep'),
|
||||
write_fn=_option_number_write('Sleep'),
|
||||
native_min=0, native_max=12, step=1, unit='h',
|
||||
icon='mdi:sleep', entity_category='config'),
|
||||
# Outdoor temperature, offset by 55. Two calibration points on one unit:
|
||||
# token 75 while an independent outdoor thermometer in the same install
|
||||
# read 20.3 C, and token 74 against a 19.4 C forecast. Fahrenheit fits far
|
||||
# worse (74 F = 23.3 C); the issue #136 unit's 81 gives 26 C in a warmer
|
||||
# climate, which is also plausible.
|
||||
SensorDesc(key='outdoor_temperature',
|
||||
rep_fn=_option_token_num('OutdoorTemp', offset=55),
|
||||
exists_fn=_has_option_token('OutdoorTemp'),
|
||||
device_class='temperature', state_class='measurement',
|
||||
unit='°C', icon='mdi:home-thermometer-outline'),
|
||||
# Filter time in tenths of an hour: the token read 1710 while the official
|
||||
# Samsung app displayed "171 hours 0 minutes" for the filter on the same
|
||||
# unit, and the .0 matching the app's "0 minutes" pins the scale. Whether
|
||||
# it counts up or down is NOT established -- it was seen rising (171.0 ->
|
||||
# 171.5) while the unit ran, which contradicts the app's "remaining"
|
||||
# wording, so the entity is deliberately named neutrally.
|
||||
SensorDesc(key='filter_time',
|
||||
rep_fn=_option_token_num('FilterTime', divisor=10),
|
||||
exists_fn=_has_option_token('FilterTime'),
|
||||
device_class='duration', unit='h',
|
||||
state_class='measurement', icon='mdi:air-filter'),
|
||||
),
|
||||
)
|
||||
|
||||
@@ -357,15 +513,23 @@ CURRENT_TEMPERATURE_VS = Capability(
|
||||
# Only the vendor resource's `fivepercentHumidity` (current reading, rounded
|
||||
# to the nearest 5%) has live data on the issue #75 dump -- its `humidity`
|
||||
# field, and the OCF-standard /humidity/0 resource entirely, both read a
|
||||
# stuck "0" there and stay ignored per the 'don't guess' rule (see
|
||||
# _AC_IGNORED below).
|
||||
# stuck "0" there, so /humidity/0 stays ignored per the 'don't guess' rule
|
||||
# (see _AC_IGNORED below).
|
||||
#
|
||||
# ARTIK051 boards (issue #136) have no fivepercentHumidity field at all, and
|
||||
# there the plain `humidity` field is not stuck: it carries a real reading
|
||||
# (51%, matching the same unit's cloud integration at that moment) for as long
|
||||
# as the Air monitoring option is on, which the unit itself switches back off
|
||||
# after roughly a minute -- so most dumps catch it at 0. Hence _humidity's
|
||||
# fallback, and hence 0 reading as "not measuring" rather than 0%: on both
|
||||
# board generations a zero here means no measurement, never dry air.
|
||||
# /humidity/0 stayed 0 throughout that same observation too.
|
||||
HUMIDITY = Capability(
|
||||
href='/humidity/vs/0',
|
||||
poll_tier='warm',
|
||||
entities=(
|
||||
SensorDesc(key='humidity', field='x.com.samsung.da.fivepercentHumidity',
|
||||
device_class='humidity', state_class='measurement', unit='%',
|
||||
value_fn=_num),
|
||||
SensorDesc(key='humidity', rep_fn=_humidity,
|
||||
device_class='humidity', state_class='measurement', unit='%'),
|
||||
),
|
||||
)
|
||||
|
||||
@@ -397,6 +561,12 @@ _AC_IGNORED = [
|
||||
'/humidity/0',
|
||||
# Presence-personalization plumbing (empty item list here).
|
||||
'/personality/presence/vs/0',
|
||||
# OCF-standard mirror of /airflow/vs/0 ({speed, direction} vs
|
||||
# {speedLevel, direction}, identical values). The climate entity reads and
|
||||
# writes the vendor form, which is the one confirmed on hardware here --
|
||||
# note that air_purifier.py found the opposite ordering on its family, so
|
||||
# neither form is reliable sight-unseen and this one stays unmodeled.
|
||||
'/airflow/0',
|
||||
# --- TP1X/TP2X-class housekeeping / opaque blobs. These carry no
|
||||
# user-actionable state or no documented write contract, so per the
|
||||
# 'don't guess' rule they are ignored rather than modeled.
|
||||
|
||||
@@ -150,6 +150,9 @@
|
||||
}
|
||||
},
|
||||
"number": {
|
||||
"buzzer_volume": {
|
||||
"name": "Beep volume"
|
||||
},
|
||||
"cook_time": {
|
||||
"name": "Cook time"
|
||||
},
|
||||
@@ -159,6 +162,9 @@
|
||||
"dispense_capacity": {
|
||||
"name": "Dispense capacity"
|
||||
},
|
||||
"good_sleep": {
|
||||
"name": "Good Sleep"
|
||||
},
|
||||
"instance_setpoint": {
|
||||
"name": "{instance_name} setpoint"
|
||||
},
|
||||
@@ -569,9 +575,15 @@
|
||||
"current_limit_level": {
|
||||
"name": "Current limit level"
|
||||
},
|
||||
"filter_time": {
|
||||
"name": "Filter time"
|
||||
},
|
||||
"hepa_filter_usage": {
|
||||
"name": "HEPA filter usage"
|
||||
},
|
||||
"outdoor_temperature": {
|
||||
"name": "Outdoor temperature"
|
||||
},
|
||||
"panel_status": {
|
||||
"name": "Panel status"
|
||||
},
|
||||
@@ -820,6 +832,9 @@
|
||||
"ai_energy_level": {
|
||||
"name": "AI Energy Mode"
|
||||
},
|
||||
"air_monitoring": {
|
||||
"name": "Air monitoring"
|
||||
},
|
||||
"air_purify": {
|
||||
"name": "Air purification"
|
||||
},
|
||||
@@ -838,6 +853,9 @@
|
||||
"dustbin_auto_close": {
|
||||
"name": "Dustbin auto-close"
|
||||
},
|
||||
"spi": {
|
||||
"name": "Purifying ion"
|
||||
},
|
||||
"uvc_intensive_mode": {
|
||||
"name": "UV-C intensive mode"
|
||||
},
|
||||
|
||||
@@ -150,6 +150,9 @@
|
||||
}
|
||||
},
|
||||
"number": {
|
||||
"buzzer_volume": {
|
||||
"name": "Zoemervolume"
|
||||
},
|
||||
"cook_time": {
|
||||
"name": "Bereidingstijd"
|
||||
},
|
||||
@@ -159,6 +162,9 @@
|
||||
"dispense_capacity": {
|
||||
"name": "Schenkhoeveelheid"
|
||||
},
|
||||
"good_sleep": {
|
||||
"name": "Good Sleep"
|
||||
},
|
||||
"instance_setpoint": {
|
||||
"name": "Instelpunt {instance_name}"
|
||||
},
|
||||
@@ -569,9 +575,15 @@
|
||||
"current_limit_level": {
|
||||
"name": "Niveau stroombegrenzing"
|
||||
},
|
||||
"filter_time": {
|
||||
"name": "Filtertijd"
|
||||
},
|
||||
"hepa_filter_usage": {
|
||||
"name": "HEPA-filtergebruik"
|
||||
},
|
||||
"outdoor_temperature": {
|
||||
"name": "Buitentemperatuur"
|
||||
},
|
||||
"panel_status": {
|
||||
"name": "Paneelstatus"
|
||||
},
|
||||
@@ -820,6 +832,9 @@
|
||||
"ai_energy_level": {
|
||||
"name": "AI Energy Mode"
|
||||
},
|
||||
"air_monitoring": {
|
||||
"name": "Luchtmonitoring"
|
||||
},
|
||||
"air_purify": {
|
||||
"name": "Luchtzuivering"
|
||||
},
|
||||
@@ -838,6 +853,9 @@
|
||||
"dustbin_auto_close": {
|
||||
"name": "Stofreservoir automatisch sluiten"
|
||||
},
|
||||
"spi": {
|
||||
"name": "Ionisatie"
|
||||
},
|
||||
"uvc_intensive_mode": {
|
||||
"name": "Intensieve UV-C-modus"
|
||||
},
|
||||
|
||||
Reference in New Issue
Block a user