Rebased onto PR #36's merge (temperature fallback for /temperatures/vs/0,
display-light switch). Reconciliation, per Opus review:
- Dropped our duplicate LIGHT capability in favor of PR #36's DISPLAY_LIGHT
(same href/entity, cosmetic differences only).
- Dropped /option/muteonce/vs/0 and /selfcheck/vs/0 from the ignore list
PR #36 added -- both have confirmed, cleanly modelable contracts (a plain
On/Off field, and a documented Start/Cancel self-check action already
covered by the existing fridge.SELF_CHECK pattern), so keeping our bound
versions instead of ignoring them. This also picks up mute_once/selfcheck_*
on PR #36's own TP1X_DA-AC-RAC-01011 fixture -- regenerated its golden.
- Deduped the ~10 housekeeping hrefs both branches independently ignored.
- Added a unit test for climate.py's _temps_vs_item (the temperature-
fallback selection logic), which had no coverage -- climate.py isn't
importable in the registry-level AC tests, and the existing "no unbound
hrefs" tests only exercise binding, not the fallback itself.
Closes the coverage-gap repair for two more room-AC boards (issues #37,
- TP2X_RAC_20K reports no oneUiVersion and no '_PRAC_' modelNum token, so
its device type went unrecognized -- add a '_RAC_' fallback token to
for_device_by_model.
- Bind the resources both dumps actually populate: mute-once (switch),
display light (switch), self-check (reused from fridge.SELF_CHECK), and
the circuit-breaker current-limit setting (read-only diagnostic sensors,
since its write contract isn't confirmed from the dump).
- Ignore the rest as plumbing/opaque/unconfirmed: control-set descriptor,
keepnormalstate flag, software-reset trigger, AI Sleep handshake,
absence-monitoring stubs, remote-data-control, remote-temperature,
reservation ruleset, and the welcome-temperature tracker.
Adds scrubbed fixtures + goldens for both dumps and extends the AC
capability/golden-regression tests to assert zero unbound hrefs.
Clears the 'Node 20 is being deprecated' warnings by moving the actions
we pin to their current Node 24 majors (both released 2026-07-20).
hassfest@master and hacs/action@main are third-party and float on their
own branches.
The suite was never run in CI (only hassfest/HACS), and requirements-dev
listed only pytest + smartthings-local while conftest.py needs the full
Home Assistant test harness.
- requirements-dev.txt: add pytest-homeassistant-custom-component (pulls
in home-assistant + pytest + pytest-socket) and the integration's
runtime deps (cbor2, pyOpenSSL, cryptography) needed to import it.
- .github/workflows/validate.yml: add a Pytest job on Python 3.14
(current Home Assistant's floor) that installs requirements-dev and
runs the suite.
- test_config_flow.py: the UDP liveness-sweep test needs real loopback
sockets, which the HA harness blocks by default; take the pytest-socket
socket_enabled fixture so it runs instead of erroring.
Full suite: 249 passed.
Review follow-up. An explicit exists_fn bypasses entity._is_included's
empty-{} stub carve-out, so the sentinel-aware energy meter would drop
power_watts/energy_kwh when /device/0 returns a not-yet-fetched stub for
/energy/consumption/vs/0. Restore the carve-out (`not rep or ...`), and
hide power_watts when instantaneousPower is absent from a populated rep
(not just when it's the -500 sentinel) so a partial rep can't spawn a
phantom power sensor.
First full dryer dump (issue #14, DV90BB5245AES1) surfaced 5 unbound
hrefs and an "incomplete capability coverage" repair. Handle them and,
while here, make the washer/dryer/dishwasher families consistent instead
of each carrying a bespoke variant of the same controls.
Dryer coverage:
- /power/0, /kidslock/0, /remotectrl/0: bind via the OCF-native + vendor
fallback pairs (prefer the standard OCF resource, fall back to -vs).
- /buzzersound/vs/0: new Buzzer sound select.
- /course/vs/0: cycle select shared with washer/dishwasher; ignore the
/st/dryercourse/vs/0 re-encoding (mirror of /st/washercourse/vs/0).
Consistency / de-duplication:
- Move generic OCF controls (power/kids-lock/remote-control fallback
pairs, energy meter) into common.py; every registry uses them.
- Move shared laundry controls (buzzer, job-beginning-status, and the
/course/vs/0 cycle-select machinery) into laundry.py; washer and
dishwasher stop hand-rolling their own copies.
- Energy meter is now sentinel-aware everywhere: the dead '-500'
instantaneousPower reading no longer shows a misleading 0 W (fixes it
on dryers and dishwashers, matching the earlier washer fix).
- Job-beginning-status reads x.com.samsung.da.currentStatus, the field
every dump actually carries; the dryer sensor was previously blank.
Adds a scrubbed dryer fixture, golden, and capability tests, plus an
.claude/skills/adding-device-support skill capturing the dump-reading,
OCF-vs-vendor, entity-taxonomy, and coverage workflow. Bumps to 0.6.0.
The config flow only probed 49154/49155, so appliances whose local
CoAP/DTLS API binds elsewhere in the ephemeral range (e.g. a dishwasher
answering on 49153) could never be added.
Add a fast UDP liveness sweep across 49152-49160 that uses the ICMP
port-unreachable / ECONNREFUSED asymmetry to find the live port(s)
before attempting the expensive DTLS handshake. Closed ports fall out
immediately; a live-but-silent port is kept as a candidate. The real
handshake then runs only against discovered ports, preferring the
historically known 49154/49155 when several look live.
Also drop the probe's /device/0 GET deadline from a bare 15s literal to
a named PROBE_GET_TIMEOUT_S constant (10s) — the slowest observed full
dump is ~8s, and 10s matches the per-resource read timeout used
elsewhere.
Bumps version to 0.5.0.
machine_state was rendering the raw lowercase OCF values (idle/active/
pause) untranslated in the UI. Add device_class=enum, options, and a
translation_key matching the existing pattern used by ice_making_status
and connection_mode, in both the shared operational.py capability and
oven.py's separate machine_state sensor.
Bump patch version for this fix plus the ice_type 'off' translation and
iot_class correction earlier on this branch.
The refrigerator fixture's x.com.samsung.da.iceType.supported list
includes "Off" alongside the whiskey_iceball_* values, but strings.json
only translated the whiskey_iceball options, leaving "Off" to render
untranslated in the ice-type select.
Coordinator prefers CoAP OBSERVE push notifications (observe.py) over
polling when the device supports it, falling back to polling only when
observe mode isn't available or drops.
Add missing washer support to the appliance table, fix stale test-count
and repo-layout claims, trim protocol-internals jargon that belongs to
the smartthings-local library rather than this integration, and point
"Adding a new appliance type" at HA's own diagnostics download instead