Both the /subdevices/vs/0 subdeviceIdList (Pattern B) and an /oic/res
link's UUID prefix (Pattern C) can name the same physical subdevice --
TP2X_FAC_BORA_21K, the Pattern B reporter's own board, does. Filtering
the two candidate lists against each other with a plain set difference
missed this when the two sources disagree on the UUID's case, letting
the same subdevice get probed and materialized twice under two
different keys.
Move the guard into _probe_prefixed itself, keyed on a
case-normalized id, so neither pattern can add a candidate the other
already claimed regardless of casing.
AWM-WW-AID-26-ONEBODY (washer+dryer combo) reports numofsubdevice='2' on
/multidevice/vs/0 but carries no /subdevices/vs/0 (no subdeviceIdList --
Pattern B's signal) and 4.04s /device/1 and /device/2 (Pattern A's). The
washer subdevice's UUID appears only as the path prefix of the
x.com.samsung.da.multidevice link in /oic/res; GET /<uuid>/device/0
answers the washer's own full Collection batch (model ..._WF80H vs the
master's ..._DV80H27H).
Treat every UUID path prefix seen in /oic/res as a prefixed-subdevice
candidate (minus ones subdeviceIdList already named), probed with the
same tolerated-404 seed RETRIEVE as Pattern B -- the shared body is
factored into _probe_prefixed. discover_partitioned's entity-level
liveness gate still decides materialization, so a UUID link with no live
sibling behind it contributes nothing.
Fixture is a live capture from the reporting board (serials/MACs/di
scrubbed); tests cover discovery, probe hygiene, washer-side entity
binding, and that the master's own entity set is unchanged.
Adds a device registry for the TP1X_DA_AC_EHS board family: separate
zone1 (space heating/cooling) and dhw (domestic hot water) loops.
zone1 is exposed as power switch + mode select + current/target
temperature sensor/number -- it's a leaving-water-temperature
setpoint, not a thermostat, so no HA platform fits it better. dhw
gets a composite water_heater entity, using the same
primary-resource-plus-sibling-reads shape climate.py already uses
for the AC (PR #247 review feedback: "Having water heaters
automatically leverage the right platform would be pretty cool!").
The unit's away mode is a device-wide switch, not the water_heater
AWAY_MODE feature -- /option/outgoing/vs/0 has no dhw-scoped sibling
and covers zone1 too, so presenting it on the DHW card would
misstate its scope.
Operation modes (Eco/Std/Force/Power) map onto HA's own standard
water_heater states, the same mapping HA core's smartthings
integration uses for this exact Samsung capability over the cloud
API. Device codes are matched case-insensitively on the read side.
The DHW entity takes a catalog name ("Hot water") rather than the
bare device name -- unlike the AC's climate card, it is one loop of
a two-loop device.
Both temperature ranges fall back as a pair: a resource reporting a
minimum but no maximum yields no range at all rather than mixing a
device bound with an invented default, matching climate._range().
Increment fallbacks test for None instead of using `or`, so a
genuine 0 survives.
set_temperature honours the optional operation_mode HA's
water_heater service schema forwards, setting the mode (and powering
the loop on) before the setpoint, the same way climate's
set_temperature handles hvac_mode.
Entity names are translated into Czech and Dutch following each
file's existing terminology conventions.
Verified against a real TP1X_DA_AC_EHS_01001_0000 diagnostics dump
(firmware AEH-WW-TP1-22-AE6000_17260402); golden-regression fixture
and full test coverage included.
`/option/autoclean/vs/0` carries three fields and only `settingStatus` was read.
That one says the feature is enabled, which it is whether or not the unit is
drying right now, so nothing reported an actual cycle.
settingStatus: On <- the existing auto_clean switch
status: Stop supportedStatus: [Start, Stop]
progress: 0
Adds a binary sensor for `status` and a percentage sensor for `progress`.
Measured on a TP1X_DA-AC-CAC-01001, sampling the resource every eight seconds
across a cycle: `Start` with progress 98 while it ran, then `Stop` with progress 0
the moment it finished. The percentage matches the figure the appliance shows on
its own display, checked against 55% mid-run.
Golden state keys updated for the 18 fixtures that bind AUTO_CLEAN. The change is
additive — no key was removed from any of them.
Full suite passes (1070 tests, Python 3.13 via requirements-dev.txt).
Complete Spanish translation for LocalThings: 257 entity names across
all platforms + full UI strings (config flow, options, issues, exceptions).
Transparency: AI-assisted (Hermes Agent), reviewed and verified by the
owner against the official Samsung SmartThings app on real hardware
(washer DA_WM_TP1_21_COMMON). Translation files only, no code changes.
Washer cycles verified one-by-one against the official app; 4 cycle codes
missing from the catalog were added from real hardware (08, 74, 06, A0).
Washer options verified: volume, finish alarm, bubble soak.
Measured on nine Samsung appliances on Korean-market firmware, every one of
which populates /oic/d with a concrete type:
4x oic.d.airconditioner AJ023CN1UBC1 system A/C, "Samsung System A/C"
3x oic.d.refrigerator "[refrigerator] Samsung"
1x oic.d.cooktop TP1X_DA-KS-COOKTOP, "Samsung Cooktop"
1x x.com.st.d.hood AHD-WW-TP1-22-COMMON, "Samsung Hood"
Every one agreed with what for_device_by_model already concluded from the board
token, so this is corroboration rather than a correction.
`x.com.st.d.hood` was the one type with a registry to point at and no row, so
this adds it.
`oic.d.cooktop` is left out on purpose, with a comment saying why: the induction
above reports it, but `cooktop` and `induction_cooktop` are unrelated registries
that happen to share the English word, and the OCF type cannot tell them apart.
Mapping it to either key would misroute the other, and since resolve() consults
this table first it would override a COOKTOP/CT board token that had it right.
Same shape of argument as the existing oic.d.robotcleaner note.
One incidental data point on the docstrings' "only ever helps a minority of
dumps": that may understate it. Nine out of nine here answer /oic/d with a usable
type, across four families. Not enough hardware to generalise from, but enough
that it looks less like a rare bonus than the comments assume.
Verified: the full suite passes (1024 tests, Python 3.13 via
requirements-dev.txt).
The Czech translation landed in commit d0c68fb (PR #233) and was
immediately out of date with en.json: subsequent commits added new
entity/option keys that didn't get backfilled. cs.json fell behind
in three buckets, all caught by test_every_language_mirrors_the_english_catalog:
- 6 dryer cycle codes added to en/nl by commit 873ed56 (PR #237):
'17' Super Speed, '21' Hygiene Care, '22' Silent Dry, '29' AI Dry,
'2b' Self Tub Dry, '4c' Air Refresh. cs.json's dryer_cycle_table_03
still had the pre-PR-#237 set.
- 'finish_time_hysteresis_minutes' option added to en/nl by commit
d905620 (PR #239). Same omission in cs.json.
- 8 entities added to en.json by the issue-triage batch now in main
(PR #224): binary_sensor.battery_charging, binary_sensor.child_lock,
sensor.air_quality_standard, sensor.battery, sensor.co2,
switch.dnd, time.dnd_end, time.dnd_start. cs.json had none of them.
nl.json was in sync, so the gap was specific to cs. Keys placed in
their natural alphabetical position within each section.
common:
- Make KIDS_LOCK_GENERIC also a read-only BinarySensorDesc (device_class='lock'),
flipping value_fn to not bool(v) so /kidslock/0 value=False and
/kidslock/vs/0 kidsLock='Ready' render with the same polarity ('On'
means open/unlocked per HA's lock device class). The old SwitchDesc
form never honored device_class='lock' -- HA's switch platform only
accepts 'outlet'/'switch' -- so the surface was a plain switch whose
'On' meaning drifted across boards. Tests updated.
air_monitor:
- Add state_class='measurement' to dust/fine_dust/super_fine_dust so
the readings feed HA long-term statistics (co2 already had it).
- Import _AIR_QUALITY_SENSORS from air_purifier instead of duplicating
it byte-for-byte; update common.sensor_item_value's docstring to
mention the third caller.
by_type/__init__: drop trailing whitespace on the new 'ASM' line.
translations/en.json + nl.json: move the new 'dnd' switch entry to its
correct alphabetical position (after display_light, before fast_preheat).
SKILL.md: add an explicit read-side rule to §5's educated-guesses
section -- guessed unit/device_class/state_class on a SensorDesc
silently mislabels readings forever with no 4.xx to catch it (unlike
guessed writes, which the device rejects). The prior air_monitor
docstring cited this carve-out as if it existed; now it does.
tests/water_purifier (issue #196): change the ailite fixture's
favorite.defaultTemperature from '85' to '50' so the test actually
reproduces the reported bug -- '50' is in showList only, so a
descriptor reading from supportedList would fail the assertion that
the current default is in its options list.
Bypass-remote-control already existed but was undocumented; finish_time
hysteresis is new. Both live under the same Configure > Device settings
menu, so cover them together as Part 4 rather than leaving a reader to
discover them by opening the options flow.
The gate holds finish_time at its last reported value until a new one
differs by at least a configured number of minutes, regardless of how
long that difference has been building up -- a magnitude-based deadband,
not a time-based debounce (which would wait for the value to stay put for
N minutes before accepting it). debounce invited the wrong mental model
for anyone reading the option name or the code later, so rename it
throughout before the option name ships: CONF_FINISH_TIME_DEBOUNCE_MINUTES
-> CONF_FINISH_TIME_HYSTERESIS_MINUTES, SensorDesc.debounce -> hysteresis,
LocalThingsSensor._debounce/_debounced_value -> _apply_hysteresis/
_hysteresis_value, and the options-flow data key/translations to match.
Minute-rounding stopped identical values from re-logging, but finish_time
still updates on nearly every poll because now() + remaining is a
continuously-drifting value between the device's own remaining-time
revisions, and washers/dryers/dishwashers commonly revise that estimate
by a minute or two mid-cycle anyway -- both are real, small changes that
individually don't matter but each cost a recorder/logbook entry.
Add a per-device Options Flow setting (finish_time_debounce_minutes,
default 3) and a SensorDesc(debounce=True) opt-in. LocalThingsSensor now
caches the last value it actually reported and only adopts a new one once
it differs by at least the configured threshold, a cycle starts (no prior
cache), or a cycle ends (new value is None) -- 0 disables it entirely,
restoring today's behavior.
Also pass config_entry explicitly into DataUpdateCoordinator's
super().__init__() -- self.config_entry previously relied on an
undocumented ContextVar fallback that upstream has flagged as removed in
HA 2026.8, which the new debounce lookup needed to not be built on top of.
_finish_time added datetime.now(timezone.utc) (fresh seconds/
microseconds every call) to the device's remaining-time duration, so the
returned timestamp differed at the sub-minute level on nearly every poll
even when remainingTime itself hadn't changed. The recorder logged a new
history/logbook entry each time, while the UI rounds the display down to
the minute, making repeated polls look like duplicate identical entries.
Round the result down to the minute so the entity only changes state
when the estimate actually shifts.
CI caught it: 8 pre-existing AC fixtures also carry genuine SmartCoolClean_/
ProgressSmartClean_ tokens in /mode/vs/0 (lnx_rac_heatpump, ara_ww_tp1_22,
windfree_oscillation, tp1x_rac_01001, fac_bora, fac_bora_2in1,
fac_bora_205_flat, cac), so odor_controller_active/odor_controller_progress
now correctly bind there too -- their golden state_keys lists just hadn't
been regenerated. Verified against the actual downloaded CI job log.
- airconditioner.py: odor_controller_active binary_sensor + odor_controller_progress
sensor, read from the /mode/vs/0 SmartCoolClean_/ProgressSmartClean_ option tokens
(SmartThings cloud custom.airConditionerOdorController capability). Read-only --
no confirmed write command.
- Reporter's TP1X_DA-AC-RAC-01001_0000 dump: fan speed and WindFree preset already
bind via the existing composite climate entity, no code change needed there.
- en.json/nl.json: new entity names for the two additions.
- cs.json: new, full Czech translation catalog (mirrors en.json topology 1:1).
- New fixture + golden + tests locking in the odor-controller behavior.
Adds the Select the official app offers next to the filter reminder --
180/300/500/700 hours -- which this board generation keeps as a FilterAlarmTime_
token in /mode/vs/0's options[] rather than on a /filter/* resource.
Confirmed on hardware: stepping through all four radio positions in the app
moved that one token and nothing else across all 19 resources, so the token
carries the hour count verbatim; and a local write of 500 to a unit sitting on
700 was accepted and kept, surviving a restart. The cloud exposes none of this,
so it is only available locally. Gated with the counter it belongs to, so
boards carrying a real /filter/airdustfilter/vs/0 threshold keep using that one
-- the gate is covered by a test that injects the token into a newer board's
dump, since no non-legacy fixture carries it and the assertion would otherwise
pass for the wrong reason.
Also settles what filter_time measures: it counts UP -- running time
accumulated since the last filter reset, not time remaining -- which an earlier
revision of that comment explicitly left open. Three independent things agree:
the token rising while the unit runs, FilterAlarmTime_ being the threshold it
is measured against, and /alarms/vs/0's filter entry tracking the counter
across two units on one site (a live unsuffixed 'FilterAlarm'/'Created' at
FilterTime_5595 against the 'FilterAlarm_OFF'/'Deleted' placeholder at 1915).
The alarm clearing by itself the moment the counter dropped under the threshold
is the causal half of that, not just correlation.
Resetting the counter is NOT solved and no reset entity is added. The
descriptor records what was tried, and what the failures do and do not prove,
so the next attempt starts from evidence instead of from scratch. Short
version: the reset is a *command* (custom.dustFilter/resetDustFilter), not a
value write, which is why nothing that writes the counter works; I could not
work out how to drive that command locally. /actions/vs/0 is the obvious local
command channel but publishes no schema, and I did not enumerate guessed action
names against a live appliance.
Written with Claude (AI), on the author's own hardware; every result quoted
above is measured on the device rather than inferred.
Replace the fixed time.sleep(GRACE_PERIOD_S) in try_enter_observe_mode
with a threading.Condition.wait_for(predicate, timeout=grace_period_s)
that returns as soon as success_fraction of subscribed hrefs have
notified. Production data (fridge TP2X_REF_20K): all 13 hrefs notify
within ~0.34s of subscribe, so every successful first-refresh / observe
retry was waiting ~14.6s of dead time. AC retry cycles showed the same
16s-fetches-that-transition pattern.
No behavior change on the fallback path (fraction not reached → wait
the full ceiling → MODE_POLL, identical to today). GRACE_PERIOD_S and
SUCCESS_FRACTION unchanged. No smartthings_local library change.
New device family: a standalone, battery-powered air-quality sensor
puck (ASM-KR-TP1-22-* board) with no controllable-appliance state at
all -- no /power/*, only /energy/battery/vs/0. Routes via both /oic/d
('x.com.st.d.airqualitysensor', confirmed against the real dump) and
the 'ASM' modelNum board token as a fallback.
/sensors/vs/0 reuses air_purifier.AIR_QUALITY's existing {type, value}
items-list decode (common.sensor_item_value) for dust/fine_dust/
super_fine_dust/odor/clean_level, sharing those capabilities' catalog
entries, and adds a CO2 reading those families don't report. The
particulate sensors deliberately get no pm10/pm25/pm1 device_class:
the values read as physically consistent (coarser >= finer) but
Samsung's own two-tier dust naming doesn't confirm where this board's
three-tier split actually maps, and mislabeling a read-side unit is a
standing, not one-shot, kind of wrong -- exposed as plain named
sensors instead. Humidity, battery/charging, and the informational air
quality standard are otherwise straightforward field reads.
/dnd/vs/0 (do-not-disturb window) is a flagged educated guess: the
write contract mirrors the read side's own string/time-format shape
(the safest kind of guess) but has no idle-vs-active dump to confirm
it end-to-end, so it's called out as such in code and will need a
reporter to verify on real hardware. /keepnormalstate/vs/0 and
/sensordatasinks/vs/0 are genuinely opaque (single unexplained value,
no supported-values list) and are ignored rather than guessed at.
Locked in with a scrubbed fixture, golden, and capability tests.
The old "don't guess" rule banned shipping any write whose contract
wasn't already confirmed end-to-end, even when the dump gave strong
supporting evidence (a supported-values/range field, an idle-vs-active
dump diff, a pattern already confirmed on a sibling board). That's
overly conservative: a CoAP write against an invalid value gets
rejected rather than acted on, so the worst case for a wrong guess is
a no-op, not a damaged appliance -- and this project already ships
flagged guesses and asks reporters to confirm them on real hardware
routinely (issues #196, #181).
Replace it with guidance to make educated guesses and ship them, but
mark them explicitly as unconfirmed (in code comments and in a direct
ask to the reporter) rather than silently presenting a guess as a
confirmed contract. Still forbids inventing a write or entity with no
supporting evidence at all, and calls out that the "worst case is
rejected" safety margin covers invalid values, not wrong-but-valid
units/semantics.
favorite_hotwater_temperature's options_field read
favorite.supportedList, which is only the four fixed presets. The
SmartThings app also lets the user add one custom value to their own
display list via its "temperatures to display" editor (bounded by
/setting/waterpurifier/vs/0's hotwaterRange), and that value shows up
in favorite.showList but never in supportedList. A unit whose current
default was that custom value rendered as HA's "unknown" state, since
current_option wasn't among the (too-narrow) options list.
showList is a superset of supportedList that always includes whatever
the current default actually is. /setting/waterpurifier/vs/0's own
hot_water_temperature select is untouched -- its write contract for
values off the old preset list still isn't confirmed, so it stays
gated off on boards that don't report supportedHotTemperatures.
KIDS_LOCK_VS_FALLBACK's write_fn wrote 'Enable', a value no dump in the
fixture corpus (washers, dryers, dishwashers, ovens, ranges, microwaves,
air purifiers, air dressers -- everything that lacks the OCF-standard
/kidslock/0) has ever reported back; every one reports 'Ready' or 'Run'.
It was never a confirmed write contract.
#181's reporter tested directly: writing the *correct* value ('Run')
still returns 4.05, and the SmartThings app itself has no control for
kids lock either -- the resource is genuinely read-only on that
hardware, not just wrong-valued. #183's reporter hit the identical
symptom (toggle does nothing) on a different device family reporting
the same Run/Ready vocabulary.
Convert the entity to a read-only BinarySensorDesc. binary_sensor's
'lock' device class is inverted from the old switch reading (On means
open/unlocked), so value_fn flips accordingly -- callers reading the
flattened 'child_lock' state key need to account for the new polarity.
KIDS_LOCK_GENERIC (the OCF-standard /kidslock/0 boolean) is untouched;
nothing suggests that one is broken.
DA_DF_TP1_21_COMMON reports a plain {setBuzzerSound, supportedFinishSound}
buzzersound resource -- the same shape laundry.BUZZER_SOUND already
handles for washers/dryers -- but it was unbound because the air_dresser
registry never included that capability. Add it, and lock the board in
with a scrubbed fixture, golden, and capability tests.
The reporter's actual complaint (course cycles showing as raw codes) is
a labelling gap, not a coverage one: this board's course table has no
code->name mapping anywhere in the dump, same as issue #162's board, so
there's nothing to bind here -- it needs a reporter to identify the
codes before they can be named in translations.
_is_placeholder_serial only caught the ARTIK051_DONGLE_REF family's
'Nothing(SVC)' sentinel. The DA_WM_A51_20_COMMON (ARTIK051) laundry
board family reports a different one instead -- every character the
same repeated hex digit -- which passed through as a real, non-unique
serial. Two different physical units (a washer and a dryer) both
reporting the literal serialNum 'FFFFFFFFFFFFFFF' collided on the
config-entry unique_id, so the second device's config flow aborted as
already configured. Widen the check (both the config_flow.py and
coordinator.py copies) to also catch that sentinel shape.
_run_subpolls is a self-limiting background loop the coordinator already
cancels and recreates every refresh cycle, but scheduling it with
async_create_task ties it into HA's startup/shutdown task tracking
anyway. A subpoll cycle in flight (up to ~27s) then delays both.
async_create_background_task is HA's supported API for exactly this
case -- a task the integration owns and manages the lifecycle of.
One commit per issue/logical change, and every commit's author and
committer must be the human accountable for the work -- never a tool,
bot, or AI agent identity, and no AI co-author trailers. AGENTS.md points
any AI coding agent working here back to CONTRIBUTING.md as the
authoritative source for this.
The "issue #N" / "OCF spec" trailing comments and the header paragraph
explaining them added noise without adding anything the value side of
the table (a real _REGISTRY_BY_KEY key) doesn't already guarantee. Update
the skill's guidance to match.