Marc Billow c181a8b447 feat(subdevices): support multi-indoor-unit systems (#177)
Samsung 2-in-1 air conditioners put more than one logical indoor unit
behind a single IP and a single DTLS session. Only the unit the config
entry was set up against was ever discovered; the second one -- a whole
physical appliance the user can see in SmartThings -- had no entities at
all. Two reporters turned out to have two different mechanisms:

  ARTIK051_DONGLE_FAC_18K -- indexed siblings. /oic/res registers the
  whole tree discoverable and lists three complete parallel resource
  sets whose trailing path segment is the index (/mode/vs/0, /mode/vs/1,
  ...), on OCF-standard and vendor hrefs alike. /device/0's batch
  carries only the index-0 hrefs, so a sibling is reachable only through
  its own /device/<n> collection.

  TP2X_FAC_BORA_21K -- UUID-prefixed tree. /oic/res hides the appliance
  tree entirely (which is why a direct /device/1 probe returns nothing
  on this board). /subdevices/vs/0 carries subdeviceIdList instead, and
  that UUID appears as a literal href prefix; /<uuid>/information/vs/0
  was confirmed live to return the wall unit's own model and serial
  (TP2X_FAC_BORA_RAC_21K) against the master's TP2X_FAC_BORA_21K.

The detection signals don't overlap on either board, so no
disambiguation is needed -- enumeration checks both and takes what
answers.

Both patterns are the same thing underneath: a logical unit is a seed
collection path to poll plus an href transform between the canonical
href the registry knows and the actual on-the-wire href. That is the
whole abstraction (SubUnit), applied at four boundaries -- discovery,
the coordinator, the adapter, and the platforms. Capabilities, the
registry and the climate composite stay written against canonical hrefs
and are untouched.

Uniqueness comes from a key_prefix inside the flattened state key, so
the master unit's keys are byte-identical to every release before this
and every existing golden file is an unchanged regression guard. Each
sub-unit gets its own device-registry entry linked by via_device and
named from its own /information/vs/<n>, so it lands in its own room
rather than crowding the master's device page.

A sub-unit materializes only when it yields at least one primary
(non-diagnostic) entity with a populated value. That gate is not
decoration: the reporter's /device/2 is an unused slot that SmartThings
shows disabled, yet it answers with a full 14-href batch, and it
flattens to exactly one non-None value -- a diagnostic alarm_code
derived from an empty /alarms/vs/2. Without the entity-category filter
it becomes a phantom third climate card. The rule is deliberately
domain-agnostic rather than a list of HVAC hrefs, so a multi-drum
washer (#19) gets the same treatment with no new curation. Units that
answer but fail the gate are logged and reported in diagnostics, so a
genuinely missing unit stays diagnosable from a dump.

Enumeration fetches things that must not then be treated as appliance
state. A rejected candidate's seed has to be read to evaluate the gate,
but only units that pass are polled again, and StateCache has no
eviction -- so discovery runs before the first cache apply and those
reps are held aside for diagnostics rather than frozen into the cache
forever. /multidevice/vs/0 is probed on every device regardless of
family, so merging it into the resources dict would have reached
discovery on any board whose registry doesn't ignore that href -- only
the air conditioner one does -- raising a spurious coverage-gap repair
for a washer or fridge whose firmware answers it. It is corroborating
metadata (numofsubdevice, confirmed read-only) and now lives beside the
resources rather than in them.

Diagnostics reports each unit separately: top-level `resources` is this
unit's own and only its own, which is what the module docstring and the
adding-device-support skill have always claimed it was, and each
sibling or rejected candidate carries its own reps canonicalized so a
block reads exactly like the master's instead of needing to be
de-indexed by hand.

Fixtures are real captures. The ARTIK051_DONGLE_FAC_18K one is entirely
verbatim, both sibling seeds and the hand-read /multidevice/vs/0
included. The TP2X_FAC_BORA one has a real device0, oic_res and
sub-unit /information/vs/0, with the remainder of that unit's tree
constructed and documented as such in seeds_note; /<uuid>/device/0 is
the one part of that pattern still inferred rather than observed, and
can't be tested through the debug panel because a Collection returns a
list.
2026-07-29 19:14:51 +00:00
Marc Billow 119a4f443c Bump version to 0.16.0 2026-07-29 04:15:41 +00:00
Marc Billow 10d5c81d9a feat(diagnostics): speculatively probe /device/1 and /device/2
/oic/res's baseline-Interface response only lists resources with the
discoverable policy bit set, and a real dump (issue #177 follow-up,
TP1X_REF_21K) confirms /device/0's whole x.com.samsung.da.* tree is
registered without it -- so a second logical Device's Collection, if
one exists, would be just as invisible to /oic/res as /device/0 is.
Probe /device/1 and /device/2 directly instead: a plain non-mutating
RETRIEVE, tolerated-404 same as every other speculative read in this
module. Parsed with the same parse_device0_batch used for /device/0
itself, and folded into identity.raw so diagnostics can tell "checked,
found nothing" apart from "never checked".
2026-07-29 04:08:19 +00:00
Marc Billow 0c8d39fb73 feat(diagnostics): capture /oic/res discovery links
/oic/res is OCF's baseline resource-discovery endpoint: a unicast
RETRIEVE returns every href/Collection the connection hosts, not just
the one /device/0 seed path the coordinator polls. Relevant to the OCF
"Composite Device" model (issue #177) -- a single physical unit sharing
one IP/session across more than one logical Device, each exposed as its
own Collection resource (same rt shape as our own /device/0). Nothing
routes on this yet; captured alongside the existing /oic/p and /oic/d
reads so a report from a multi-unit device shows us whether its
firmware actually implements that model before any code assumes it does.
2026-07-29 03:53:27 +00:00
Marc Billow a7aea3764b feat(airconditioner): make absence/motion-detect enable switches writable
status on both /mds/absencepowersaving/vs/0 and
/option/motiondetectwind/stateful/vs/0 is a bare On/Off boolean, the same
shape already shipped writable elsewhere in this file (MUTE_ONCE,
AUTO_CLEAN, AIR_PURIFY) without a live-confirmed write either -- worst
case a wrong token no-ops. The paired mode selects (switchPowerSaveMode,
motion-detect modes) stay read-only: their behavioral effect on live HVAC
isn't inferable from the dump, same reasoning as ANOMALY_LOAD's mode field.
2026-07-29 03:34:18 +00:00
Marc Billow a6eb1c62d4 feat(microwave): add filter reminder / end signal reminder switches (#181)
Both FilterRemind_*/RemindBeep_* option-array tokens are already
present -- and both On and Off already confirmed -- on the existing
ME7500D fixtures (issue #152), so this is a straight sibling of the
Sound/Lamp switches rather than new discovery work. Gated with
exists_fn like Lamp since the MW7300B combi dump has neither token.

Doesn't address the rest of issue #181 (power-level slider,
non-reported cooking modes, 3-level light, child lock, send-to-
microwave) -- those need write-contract confirmation this dump
doesn't carry.
2026-07-29 02:55:47 +00:00
Marc Billow 90d79f117a build: pin minimum Python to 3.13 in pyproject.toml
README.md and requirements-dev.txt already document that the test
harness needs Python 3.13+ (pytest-homeassistant-custom-component
doesn't resolve below it), but only in prose. Add requires-python so
pip fails fast with a clear message on an older interpreter instead of
a wall of "Requires-Python >=3.13" version-list noise.
2026-07-29 02:52:38 +00:00
Marc Billow 2b24152276 feat(registry): cover absence-power-saving and motion-detect-wind on AC (#173)
Lennox-branded heat pump on the Samsung RAC board family (modelNum
TP1X_LNX-AC-RAC-01001_0000) already routes correctly via the existing
'-RAC-' token, but its dump has two resources no prior AC fixture
carried: /mds/absencepowersaving/vs/0 and
/option/motiondetectwind/stateful/vs/0. Bind both as read-only
sensors, matching the CURRENT_LIMIT/ANOMALY_LOAD precedent -- nothing
in the dump confirms write safety on live HVAC hardware.
2026-07-29 02:52:33 +00:00
Marc Billow 40c7033b1b docs(readme): update device-type routing and test setup
Three things this branch left stale.

"Adding a new appliance type" step 4 told contributors to key the registry
on the lowercased suffix of oneUiVersion and pointed at _type_key() for the
transform. Neither exists any more, and oneUiVersion no longer routes at
all. Describe the board-token table instead, including the two rules that
keep it a table: whole-token matching covers every delimiter spelling, and
an entry must name the specific device type rather than the board family
that contains it.

The repo-layout line for identity.py said "Reads device identity for type
detection". It has never fed type detection -- it reads /oic/p and /oic/d
for the HA device registry, and now also carries OCF's device-type
declaration into diagnostics.

The test setup installed pytest-homeassistant-custom-component and
homeassistant unpinned on top of requirements-dev.txt, which already pulls
both in at matching versions, and used whatever `python3` resolves to. On
3.12 or older nothing resolves and the install fails outright with a wall of
version-conflict output that doesn't name the real cause. Say 3.13+, drop
the redundant install, and note CI runs 3.14.
2026-07-29 02:27:00 +00:00
Marc Billow c9620b47b3 fix(diagnostics): redact the OCF device name; log description on unknown type
Two things a review of this branch turned up.

/oic/d's `n` is free text the owner sets from the SmartThings app, so it may
carry a person's name. Nothing in the /device/0 dump has ever exposed it --
it only became reachable when diagnostics started reporting /oic/d earlier
in this branch, which would have started carrying it into public issue
reports. Redact it. `rt`, the device-type signal the block exists for, is
untouched, and no /device/0 resource uses a bare 'n' key, so nothing else
changes.

The unknown-device-type warning logged only modelNum. That line is what a
user pastes into an issue, and modelNum alone can't identify a washer from a
dryer -- both report the shared DA_WM_ laundry board, and detection reads
the consumer-model code out of `description` for exactly that reason. Log
both fields.
2026-07-29 02:20:37 +00:00
Marc Billow cafd7d5afa refactor(registry): drop oneUiVersion from device-type detection
oneUiVersion looks like the signal you'd want -- the device naming its own
type, '7.0 Dishwasher' -- and it was the first thing detection consulted. It
never earned the position:

- Only 7 of 49 fixtures report it at all.
- All 7 resolve to the same registry from their modelNum board token alone.
- No device-support issue has ever been fixed by adding a mapping for it.
  Every one went through modelNum. The alias keys it needed in
  _REGISTRY_BY_KEY ('airpurifier', 'air_conditioner', 'hood') were
  speculative when the registries were first written and never used since.

So it bought a key-normalizing helper (_type_key), a lookup with a suffix
fallback (for_device), three alias keys, and a second config-flow step whose
only reason to exist was phrasing a sentence about oneUiVersion -- for a
signal that has never once been decisive.

Remove it from detection. It stays in diagnostics, where it's genuinely
useful: it names the firmware generation ('7.0 Air conditioner' is Tizen
Lite), which matters when triaging an issue.

Detection order was also duplicated in four places -- the coordinator, the
config flow's probe, the golden-regression harness, and the skill -- which
is how the harness and the shipped order drift apart. Collapse it into
by_type.resolve(resources), and call that everywhere.

The two "appliance type not recognized" config steps become one. They
differed only in whether they blamed a missing oneUiVersion, which is not a
distinction a user can act on, and never was.

Verified by the full suite (795 passing), including every golden regression
-- so entity output is byte-identical for all 49 device fixtures.

TestOneUiVersionIsNotConsulted locks in the premise rather than just the
outcome: for every dump that reports a oneUiVersion, the model strings alone
must still reach a registry. If a future device breaks that, the test says
so instead of the device silently losing half its entities.

Also note in requirements-dev.txt that Python 3.13 resolves the pinned
harness floor -- 3.12 and older resolve nothing and fail the whole install.
2026-07-29 02:14:13 +00:00
Marc Billow a863df1e59 refactor(registry): match board families by token table, not substring ladder
for_device_by_model() had grown to 21 sequential `if key is None` branches
and 102 comment lines against 59 lines of code -- 33 of the repo's 243
commits have touched this file. Most of that bulk came from one wrong
primitive: substring matching on a delimited string.

Samsung spells the same board family with either delimiter, so '_RAC_' and
'-RAC-' each needed their own rule, and 'ARTIK051_DONGLE_REF' (issues #77,
#83) matched no '_TOKEN_' spelling at all because REF lands at the end of
the pipe-prefix with no trailing underscore -- which is what
_model_num_segments() existed to work around. Which field a rule searched
(modelNum, or modelNum + description) was historical accident. Collisions
like WAC vs WA were resolved by one `if` physically preceding another,
invisible in the code and explained at length in prose.

Tokenize on any non-alphanumeric run, upper-case, and look the tokens up in
a flat table. Every delimiter spelling collapses to one entry, both fields
go through the same matcher in a documented order (modelNum, then
description, then the fuzzy consumer prefix), and specificity is a property
of the table rather than of line ordering.

Two behaviours are preserved deliberately:

- modelNum is matched before description, which is what keeps the legacy
  gas cooktop correct: it reports 'ARTIK051_GB_CT_001' (CT) alongside
  'ARTIK051_GLOBAL_COOKTOP' (COOKTOP, which otherwise means induction).
  It is the only known device whose two fields disagree.
- _consumer_model_key still splits on '_' only. Widening it to '-' would
  read the dishwasher's 'ADW-WW-RTL-24-AILITE' board segment as a bare 'WW'
  washer.

Verified identical: all 49 device fixtures resolve to the same registry
before and after, and every existing for_device_by_model test case passes
unchanged. The table also picks up two families that previously depended on
oneUiVersion alone (TP1X_DA-AC-AIR air purifiers, ADW dishwashers), so they
now survive firmware that omits it.

TestBoardTokenAmbiguity guards the one property the flat lookup needs --
that no real model string contains two tokens naming different device types
-- across the whole fixture corpus, so a newly added dump exercises it
automatically.

The skill gains a section on routing: what each detection stage is for, the
rules for adding a token (name the specific type, never the board family;
never add a delimiter spelling; two-letter tokens are a last resort), when
to reach for the consumer prefix or a resource signature instead, and the
measured stake -- an unrouted device loses roughly half its entities.
2026-07-29 01:57:10 +00:00
Marc Billow 288ba02cc5 feat(diagnostics): capture /oic/p and /oic/d identity
Device-type detection currently parses board part numbers out of
/information/vs/0's modelNum. OCF has a standard field for exactly this
question -- /oic/d's `rt` -- and read_identity() already fetches the
resource, but kept only `n` and threw the rest away. No captured dump has
ever included it either: /device/0 batch responses don't carry /oic/d, and
diagnostics didn't report it, so there's no evidence on whether real
hardware populates it usefully.

Keep `rt` as DeviceIdentity.device_types, keep both raw payloads whole
(we don't yet know which of their fields identify a type), and surface
them in diagnostics so incoming issue reports answer the question.

Nothing routes on it yet.

/oic/d and /oic/p identify the unit with bare two-letter keys -- 'di' and
'pi' -- as sensitive as the serial number redact.py already covers but far
too short to match on: 'di' alone is a substring of 'condition', 'display'
and 'dispenser'. Add a whole-key match alongside the substring rules.
2026-07-29 01:56:52 +00:00
Marc Billow bbf3f3f833 Revert unsound air-quality gating from #170, cover remaining fan-speed icons
An Opus review of merged PR #170 found the cleanLevel-scalar existence
gate on AIR_QUALITY doesn't hold up as a general rule: three fixtures
in this repo (air_purifier_device.json, air_purifier_vtww_device.json,
range_hood_device.json) carry genuinely populated Dust/FineDust/
SuperFineDust readings with no such scalar, so requiring it risks
silently dropping real air-quality readings on AC hardware this repo
hasn't seen yet. Reverted _has_sensor_type to item-type presence only
(as before #170) and moved the #166 fix to enabled_default=False on
all five entities instead -- same conservative, non-existence-gated
treatment already used for tropical_night_mode and the fridge/cooktop
precedents it was modeled on. Golden fixtures and tests updated to
match; the five sensors are bound-but-disabled on windfree/#17-style
boards again rather than unbound.

Also added icons for the AC fan_mode values #170 missed -- the raw
numeric labels ("1".."5") that TP1X_DA-AC-RAC-01001 and the window-AC
board report instead of turbo/max -- and swapped the whole fan-speed
icon family to mdi:fan-speed-1/2/3 for a more purpose-built look than
the generic speedometer, applied consistently to both the AC climate
card and the air purifier fan. Fixed motiondirect/motionindirect to
match core's smartthings integration's arrow pairing (previously
inverted).

Known limitation, not fixed here: enabled_default only affects newly
registered entities. Anyone who already has tropical_night_mode or the
five air-quality sensors enabled from #164 (a narrow window before
this fix, but real) won't see them auto-disable -- they'd need to
disable them by hand in Settings > Devices > Entities. A real fix
needs a one-time entity-registry migration, which this integration has
no existing infrastructure or test coverage for; scoping that felt
like its own follow-up rather than something to bolt on here.
2026-07-28 19:07:59 +00:00
Marc Billow 91b129282b Bump version to 0.15.0 2026-07-28 18:56:07 +00:00
Marc Billow 6d185e4e3d Match WindFree icon to the official smartthings integration's choice
HA core's bundled smartthings integration (the cloud counterpart to
this same Samsung AC feature set) uses mdi:weather-dust for its
wind_free preset rather than a generic windy icon -- a better fit for
a feature about avoiding direct airflow, not blowing harder. Match it
for both the AC climate preset and the air purifier fan preset.
2026-07-28 18:47:10 +00:00
Marc Billow 5f47fc0477 Add per-state icons for the remaining entities that render with none
HA only consults icon-translation state icons when the entity has no
static icon of its own (Entity.icon, if set, always wins -- see
homeassistant.helpers.entity's state_attributes construction). Audited
every entity with a labelled state/state_attributes catalog in
translations/en.json against its descriptor's icon= setting: every
select (cycles, courses, brightness levels, ...) and most sensors
already carry a fixed icon in code, so per-state icons there would be
silently shadowed. The three that don't -- air_purifier_fan's
preset_mode, machine_state, and connection_mode -- get one per value
here.
2026-07-28 18:31:31 +00:00
Marc Billow cfa82e8853 Add icons for AC preset/fan modes not covered by HA's built-ins (#169)
HA's core climate component already ships default icons for common
preset_mode/fan_mode values (eco, away, sleep, auto, low/medium/high,
...), but this integration's own values -- WindFree (nano/nanosleep),
Quiet, Smart, Speed, Long wind, the motion-aware direct/indirect
presets, Dry comfort, 2-Step, and the turbo/max fan speeds some boards
report -- fall outside that vocabulary and rendered with the generic
circle-dot fallback (the icon the #169 screenshot is missing). Adds
icons.json with an icon per value, mirroring the state-label catalog
these same values already have in translations/en.json.
2026-07-28 18:20:10 +00:00
Marc Billow 739881de16 Gate AC tropical night mode and air-quality sensors on real capability signals (#166)
Issue #166 (ARxxTXFCAWKNEU, board ARTIK051_PRAC_20K) reported tropical
night mode, clean level, dust, fine dust, odor, and super fine dust
entities showing up even though the reporter's units have no such
physical features. All six were added in #164.

The Sleep_<N> options token backing tropical_night_mode is present in
every AC dump on record regardless of confirmed reality, so there's no
usable signal at boot time -- it's now registered but disabled by
default (matching the precedent already set by fridge.rack_count /
cooktop.paired_hood_model), letting units that do have it opt in.

/sensors/vs/0's item-type list has the same problem (all five types
always listed, permanently zero on this board), but there turned out
to be a real tell: a top-level x.com.samsung.da.cleanLevel scalar is
present only alongside genuinely populated readings on every dump on
record (tp1x_da_ac_rac_01011, the tp1x_da_ac_air air purifier fixture)
and absent on every all-zero ARTIK051_PRAC_20K dump, including both
#166 units and the original windfree/#17 fixtures this capability was
first verified against -- which, per their /information/vs/0, turn out
to be the same board revision as #166's units, so that "verification"
never actually proved a real sensor either. AIR_QUALITY's exists_fn now
requires that scalar, and the windfree/airconditioner golden fixtures
are updated to match (those five entities no longer bind there).
2026-07-28 18:12:02 +00:00
Marc Billow 71e026b804 Fix hot/warm href tiers dropped for no-entity coverage capabilities
discover() only emitted a BoundEntity per capability *entity*, so a
coverage-only Capability (entities=(), used to mark a href as handled
elsewhere -- e.g. the AC climate card's wind/strength, wind/direction,
temperature/control hrefs) produced zero rows. The coordinator computed
its hot/warm href lists by walking `bound`, so every such href's
poll_tier was silently discarded and it fell back to the ~30s summary
poll only -- no sub-poll cadence and never attempted for OCF OBSERVE.

This is the root cause of issue #166's "up to a minute" lag for
remote-driven fan-speed changes: /wind/strength/vs/0 carries poll_tier
'warm' via airconditioner.COVERAGE but never reached
_hot_hrefs/_warm_hrefs, so it wasn't in the OBSERVE-attempt href list
and only refreshed on the summary poll.

discover() now takes an optional tier_log(href, poll_tier) callback
fired for every href a capability matches, entities or not. The
coordinator uses it directly instead of deriving tiers from `bound`.
2026-07-28 15:08:12 +00:00
Marc Billow 65b0326d62 Merge remote-tracking branch 'origin/main' into claude/issue-triage-138-latest-y90g78
# Conflicts:
#	tests/test_airconditioner_capabilities.py
2026-07-28 14:51:29 +00:00
Marc Billow 6007505e6b Stop surfacing '_OFF'-suffixed placeholder alarm codes (#166)
Samsung pre-populates /alarms/vs/0 with one row per supported alarm type,
each carrying a '<Name>_OFF' placeholder code (no 'Deleted' state at all)
when that alarm isn't firing. common._active_alarm_codes only ever
filtered on 'Deleted' state, so every device using this shared capability
(including the AC family) showed these inert placeholders --
'ErrorCode_OFF', 'FilterAlarm_OFF' -- as if they were live alarms.

Confirmed the '_OFF' suffix convention holds across every alarm code seen
in this repo's fixtures so far (ErrorCode_OFF, FilterAlarm_OFF, OV_E_OFF,
CT_E_OFF, WaterTankFull_OFF, AC_V_0002_OFF, all placeholders; DoorA_Opened,
FilterAlarm, SNSF_Reached, all genuinely active with no suffix) -- issue
#166's own dump has both a FilterAlarm_OFF placeholder and, on a second
unit, a live FilterAlarm/state=Created alert, which is what motivated
generalizing range_hood.py's existing (but narrower, ErrorCode_OFF-only)
special case into the shared helper instead of duplicating it further.

The other three points in #166 (filter-usage percentage vs. filterStatus
disagreement, an "air purification" config toggle the reporter says has no
physical effect, a "beep on/off" control) don't have a confirmed code fix:
the percentage math already matches the device's own filterUsage/
filterCapacity fields (filterStatus is a separate device-computed field we
already relay verbatim, not something we derive), the air-purify resource
is correctly wired to what the board reports and its absence from the
official app's own options list suggests an inert shared-board-profile stub
rather than an integration bug, and a "Beep volume" NumberDesc keyed off
the same Volume_100 option both dumps report already exists (0 mutes it).
2026-07-28 14:43:21 +00:00
Marc Billow 5a73a25005 Address independent code review findings on PR #167
Two real bugs, both latent (no shipped fixture exercised them), plus a
consistency gap and a couple of correctness/DRY nits flagged by review:

- async_set_fan_mode resolved a fan_mode label against the static
  _FAN_TO_DEVICE reverse map before checking whether the resulting code is
  actually one of the unit's own supportedModes. A board using non-standard
  wind-strength codes while still spelling a standard-looking label in
  modesName (e.g. codes "31"-"33" named "Low"/"High"/"Turbo") would silently
  write a code ("1"/"3"/"4") the device never advertised. Now validates the
  static hit against the unit's own supported codes before trusting it,
  falling through to the live modesName scan otherwise.

- air_purifier.WIND_STRENGTH_FAN reused key='fan', the same key as FAN in
  the same registry -- BoundEntity's unique_id is built from key alone, not
  href, so a board reporting both hrefs would have one fan entity silently
  shadow the other. Renamed to 'wind_strength_fan' (translation_key
  unchanged). No shipped fixture reports both hrefs today, but the two caps
  living in the same registry made this a real latent hazard, the exact one
  AIRFLOW_GENERIC's own comment already documents and deliberately avoids.

- microwave.py's cooking_mode select still used a static, union-of-all-
  dumps mode list, even though both shipped microwave fixtures already
  report x.com.samsung.da.supportedModes on /mode/vs/0 -- the same shape
  oven._oven_mode_options was just built to prefer over exactly this kind
  of static list (issue #138's follow-up, this same PR's skill update).
  ME7500D advertises 4 modes; the select was offering 11. Applied the same
  live-first, static-fallback pattern.

- Added the issue #152 fixture the microwave lamp fix was missing (the
  SKILL.md step this PR itself added asks for one).

- climate.py's _legacy_airflow rebuilt a 2-key presence dict from
  coordinator.resource()'s truthiness, which collapses "href absent" and
  "href present with an empty {} rep" to the same falsy value -- while
  is_legacy_board (and discover()'s own binding) test key membership, not
  truthiness. Simplified to pass last_resources through directly, matching
  is_legacy_board's actual contract instead of a cheaper approximation of
  it, so the "can never disagree" claim in both docstrings is actually true.

- Hoisted the 'power' payload branch duplicated verbatim across
  _airflow_fan_write/_fan_write/_wind_strength_fan_write into one
  _power_write helper (registry/capabilities/air_purifier.py).

- Removed two now-unused imports (test_air_dresser_capabilities.py,
  test_air_purifier_vtww_fan.py) and replaced a tautological
  code-in-_DEVICE_TO_FAN check with one that actually exercises the live
  climate entity's fan_modes/fan_mode (test_climate_ac_modes.py).

- Fixed a pre-existing (not from this PR) no-op test on main --
  test_registry_reproduces_golden_state_keys_for_induction_cooktop computed
  golden/state_keys and never asserted on them.

756 tests pass.
2026-07-28 14:37:32 +00:00
Marc Billow dc3e1255d1 Ignore fridge /rm/control/vs/0 plumbing href (#165)
TP1X_REF_21K's EU region variant reports a bare resource-monitoring
poll-interval config (minPeriod in ms) the US variant doesn't -- the only
unbound href keeping the coverage-gap repair open. Door sensors, the
reporter's actual ask, were already covered generically by
fridge.DOOR_GENERIC/DOORS_FALLACK.
2026-07-28 14:27:15 +00:00
Marc Billow daa7546208 Add device support for Wind-Free 2-in-1 AC TP2X_FAC_BORA_21K (#150, #153)
This board (a floor-standing + wall-mounted indoor unit pair sharing one
outdoor unit and one local IP) reports no oneUiVersion and carries the
'_FAC_' modelNum token, which no existing routing rule matched -- it fell
back to 'unknown' and exposed nothing but a power switch, with no climate
entity generated at all (both issues' reported symptom).

Once routed to the existing airconditioner registry, it binds cleanly
against the exact same CLIMATE composite every other room-AC family uses --
same Cool/Dry/Wind/AIComfort mode vocabulary, same wind-strength/humidity/
filter/energy resource shapes already modeled. Only two hrefs are unique to
this board: /subdevices/vs/0 (an opaque paired-subdevice id list -- issue
#150 asked whether the second indoor unit can be controlled separately;
it can't through this or any other resource in the dump, the same
"remote device ids, not locally actionable" role as the existing
/remotedeviceinfo/vs/0 ignore) and /runn/vs/0 (a single undocumented int
with no supported-values list to interpret). Both added to _AC_IGNORED
rather than guessed at.
2026-07-28 14:09:21 +00:00
Marc Billow e568145deb Fix microwave lamp switch reading/writing the wrong tokens (#152)
The lamp SwitchDesc was modeled on issue #137's dump, which only ever
showed 'Lamp_Off' -- 'On' was never actually confirmed as the paired
value. Issue #152's ME7500D dump (same TP1X_DA-KS-MICROWAVE-01051 family)
is the first to report a real non-Off value, and it's 'Lamp_High' (a
brightness level), not 'Lamp_On'. So the switch always read as off
regardless of the device's real state, and toggling it on wrote a token
('On') the device has never been observed to accept -- matching the
reported "light control does not have any effect."

value_fn now treats any non-Off/non-absent value as on; write_fn now
writes back 'High'/'Off', the two tokens actually confirmed live, instead
of the never-confirmed 'On'.

The reporter's suspicion about the fan is unconfirmed and this dump's own
/hood/fanspeed/vs/0 shape already matches the no-separate-power case
fan.py's LocalThingsRangeHoodFan handles correctly (issues #137/#142), so
no fan change was needed here. A second dump attached in a comment on this
issue (model ME8000T, a large combi wall-oven with a very different mode
vocabulary) reports its own distinct gap and doesn't resolve to any known
device type at all -- that's a separate, substantial device-support task
left for its own follow-up rather than folded into this fix.
2026-07-28 14:03:56 +00:00
Marc Billow fcd34f73e5 Add device support for BESPOKE Cube Air A-VTWW-TP2-21-COMMON (#151)
This board reports no oneUiVersion and no modelNum token any existing
family routed on, so it fell back to unknown -- exposing nothing but power
even though most of its resources (air quality sensors, HEPA filter,
device-active, diagnosis, plumbing hrefs) are already handled generically
by the existing air_purifier registry via the '-VTWW-' modelNum fallback.

The one genuinely new piece is its fan: this board reports wind strength as
numeric codes ("87"/"89"/"90"/"91") on /wind/strength/vs/0 with a separate
modesName array ("SMART"/"MAX"/"WINDFREE"/"Sleep") giving the actual names,
unlike the existing TP1X_DA-AC-AIR family where supportedModes IS the name
list already. Generalized LocalThingsAirPurifierFan to resolve a mode code
through modesName when present (same live-label pattern as climate.py's AC
wind-strength fix, issue #155) instead of adding a second hardcoded fan
class, and added WIND_STRENGTH_FAN reusing the same 'air_purifier_fan'
translation catalog -- both board generations land on the identical
smart/max/windfree/sleep vocabulary already labelled there.

/mode/convenient/vs/0 is empty on this dump and added to COVERAGE alongside
the existing plumbing hrefs this board also shares with the TP1X_DA-AC-AIR
family.
2026-07-28 13:58:08 +00:00
Marc Billow a3d9cce164 Extend AirDresser support to DA_DF_TP2_20_COMMON (#157)
A different board generation from issue #162's DA_DF_A51_20_COMMON, also
carrying the '_DF_' modelNum token and so already routed into the
air_dresser registry -- but reporting two resources #162's board doesn't:

  /st/airdressercourse/vs/0 -- the course table id (Table_00), read the
    same way washer/dryer read /st/washercourse|dryercourse/vs/0. Wired up
    as AIR_DRESSER_COURSE's table_href and added to the global ignore list,
    mirroring that existing pair exactly.
  /airdresseroption/sanitize/vs/0 -- a genuine on/off setting (not covered
    by any existing capability), added as AIR_DRESSER_SANITIZE.

Introducing table_href means the course select's translation_key is now
always the table-lookup callable, so the bare 'air_dresser_cycle' catalog
entry added for #162 (only ever used when no table_href was passed) is
unreachable in every case and is removed -- both boards fall back to the
shared 'cycle' entry until their course tables get named, same as
washer/dryer's own precedent for an unrecognized table.
2026-07-28 13:50:59 +00:00
Marc Billow 053e15bba6 Add device support for Samsung AirDresser DA_DF_A51_20_COMMON (#162)
This board reports no oneUiVersion and no modelNum token any existing
family routed on, so it fell back to the global unknown-device CAPABILITIES
set -- exposing only power/child-lock/start-stop-pause/delay/energy/machine
state, with /course/vs/0, /diagnosis/vs/0, and /washer/vs/0 all unbound and
no course/mode select at all (the actual reported gap).

Every one of those resources turns out to already be handled by the shared
laundry machinery: /diagnosis/vs/0 reuses dishwasher.DIAGNOSIS, and
/course/vs/0's cycle select works unmodified through laundry.cycle_options'
existing supportedOptions fallback (this board has no /wm/editcourse/vs/0
at all, so editCourseList never populates). /washer/vs/0 gets a new minimal
AIR_DRESSER_SETTINGS capability (wrinkle_prevent only) rather than reusing
dryer.DRYER_SETTINGS wholesale, since this device never reports
dryLevel/dryTime/dryerType at all and binding them would ship three
permanently-unavailable sensors.

Course codes aren't identified yet (no code->name mapping was reported), so
they render as their raw codes until named in translations, same as
dryer.py's precedent for unidentified codes.
2026-07-28 13:45:49 +00:00
Marc Billow aa9cdd83b7 Read AC fan speeds from the device's own modesName, not just 0-4 (#155)
TP1X_DA-AC-RAC-01001_0000 (model AR07C9150HZN) reports /wind/strength/vs/0
supportedModes as "0"/"31"-"35" instead of the "0"-"4" scale climate.py's
_DEVICE_TO_FAN was built from. Only "0" matched, so fan_mode/fan_modes
silently dropped every speed but Auto -- exactly the reported symptom.

Rather than hardcoding a second numeric scale, codes _DEVICE_TO_FAN doesn't
cover now fall back to the device's own modesName label (parallel-indexed
with supportedModes), mirroring how preset_mode already resolves dynamically
off a device's own supportedModes instead of a per-model table. Boards using
the standard 0-4 scale are unaffected -- _DEVICE_TO_FAN is still tried
first, so existing auto/low/medium/high/turbo labels don't change.
2026-07-28 13:38:42 +00:00
Marc Billow 57e06c5ccb De-duplicate the legacy ARTIK051 AC board-generation test (#161)
capabilities/airconditioner.py's is_legacy_board() (renamed from the
private _is_legacy_board -- it's now a cross-module helper) and
climate.py's _legacy_airflow() implemented the same "does this board have
/airflow/vs/0 but no /wind/strength/vs/0" test independently, one via
literal href strings and the other via coordinator.resource() truthiness.
is_legacy_board() now uses the module's own HREF_AIRFLOW/HREF_WIND_STRENGTH
constants, and _legacy_airflow() delegates to it via a minimal two-key
presence dict (cheaper than a full last_resources snapshot copy) instead of
re-implementing the check, so the token entities and the climate card's
legacy read/write paths can't drift apart on which board generation is in
play.
2026-07-28 13:31:37 +00:00
Marc Billow 5c962801b4 Fix _tropical_night_value, which had the same stale _option_token assumption
Same issue as the beep fix in the previous commit: this also assumed
_option_token returned the full 'Sleep_<N>' token and tried to split
off the prefix itself. With the canonical value-half _option_token,
that always returned None. Read the value directly instead.
2026-07-28 13:29:49 +00:00
Marc Billow c8597532b0 Stop collapsing a genuine fivepercentHumidity=0 reading to unknown (#160)
#146's zero-as-"not measuring" carve-out was meant for ARTIK051 boards'
plain x.com.samsung.da.humidity field, which only populates while Air
monitoring is briefly on and zeroes out afterward. It was accidentally
applied to fivepercentHumidity too, which every other AC board relies on
and which has never been documented getting stuck at zero -- so a real 0%
reading on those boards silently became "unknown". Only the humidity
fallback field now collapses 0; fivepercentHumidity passes 0 through as a
real reading.
2026-07-28 13:28:46 +00:00
Marc Billow 00c1d78373 Merge main into ac-additive-entities, resolve conflicts with #146
Both PRs independently modeled the same /mode/vs/0 Volume_*/Sleep_*
option tokens: #129 as beep/tropical_night_mode, #146 (already merged)
as buzzer_volume/good_sleep gated to the legacy ARTIK051 board
generation. They also each defined a helper named _option_token with
different return semantics (full token vs. value half) in
non-overlapping parts of the file, so git didn't flag it as a
conflict even though the second definition silently shadowed the
first.

Keep a single _option_token (value-half, the one already used by
buzzer_volume/good_sleep/spi/etc.), adjust beep's read/write to that
convention, and gate beep/tropical_night_mode off the legacy board so
they don't duplicate buzzer_volume/good_sleep on ARTIK051_KRAC-class
devices. Added a regression test locking in the gate.
2026-07-28 13:28:20 +00:00
Marc Billow 1cdad7f84c Read oven cook modes live from the device instead of a hardcoded list
Follow-up to the issue #138 fix: rather than hand-adding
ConvectionRoast/KeepWarm/BreadProof/AirFryer/Dehydrate/SelfClean/SteamClean
to oven._OVEN_MODES, read them from the device's own /mode/vs/0
supportedModes when it reports one, falling back to the static
NV7000BS-era guess only when it doesn't. Matches the adding-device-support
skill's preference for device-reported option lists over hardcoded ones,
and the SelectDesc's write validation now checks the same live list it
displays instead of a separate static tuple.
2026-07-28 13:26:41 +00:00
Marc Billow 1fb27c30ae Skill: call out preferring dynamic select options over hardcoded lists
Prompted by issue #138's fix, which extended oven._OVEN_MODES with newly
confirmed modes instead of reading them from the device's own
supportedModes field via options_field -- the pattern laundry.py already
uses for buzzer/finish sound. Document that preference so future
device-support work reaches for options_field/a callable first and treats
a static tuple as a last resort, not the default.
2026-07-28 13:18:46 +00:00
Marc Billow 123455a873 Add missing oven cook modes for NE63A6511SS/AA range (issue #138)
The range/oven-combo device in issue #138 (NE63A6511SS/AA, no
/information/vs/0) already resolves cleanly to the range registry via the
issue #74 for_device_by_resources fallback, with zero unbound hrefs -- the
reporter was just on an older release (0.11.1) predating that fix.

However its /mode/vs/0 supportedModes advertises ConvectionRoast, KeepWarm,
BreadProof, AirFryer, Dehydrate, SelfClean, and SteamClean, none of which
were in oven._OVEN_MODES. Since range.py reuses oven.OVEN_MODE's SelectDesc
wholesale, those modes were silently rejected by the mode select's write
validation and missing from its options. Extend the confirmed mode list and
lock in a scrubbed fixture, golden, and test for this dump.
2026-07-28 13:12:40 +00:00
Marc Billow 6239706065 Keep entity._is_included's default gate permissive on confirmed-empty reps
Opus review of #149 caught that swapping is_stub_rep(rep) in for the
default field-presence gate (not just the 9 hand-audited exists_fn call
sites) was too broad: it silently excludes entities on ANY resource whose
normal, valid state includes reporting {} -- /alarms/vs/0's {} is
fridge.py's documented no-alarm state, not an absence signal, and it's not
the only one (job_beginning_status, diagnosis_status, sabbath_mode,
defrost_delay, ice_maker_enabled all lost entities on real fixtures under
the broader change). That's the opposite of #127's fix: a real fridge
would have dropped its alarm sensor on first-poll timing, not just its
phantom energy sensors.

Restored the default gate to include on either a stub or a genuinely-empty
rep -- verified byte-identical to the pre-#149 baseline across all 40
fixtures, apart from the 9 deliberately-audited exists_fn sites (energy
meter, self-check error, cooktop burner, range-hood auto-op), which are
unaffected and still fix #127. Added tests/test_entity.py exercising
_is_included directly (previously untested) and fixed two now-stale
"not rep" doc references the review also flagged.
2026-07-28 03:18:23 +00:00
Marc Billow 33786ad584 Distinguish not-yet-fetched stub reps from confirmed-empty ones (issue #127)
parse_device0_batch used to collapse /device/0's {"href": "..."} "no data
yet" marker into a plain {}, indistinguishable from a resource the device
had actually polled and confirmed empty. Every exists_fn using the "not
rep or ..." stub carve-out (and entity._is_included's default field-gate)
then treated both the same way, creating phantom always-"unknown" entities
for any resource a model simply doesn't support (e.g. GSzabados's fridge's
/energy/consumption/vs/0).

is_stub_rep() now recognizes only the literal {"href": ...} marker as a
stub; a genuine {} is treated as the device's real (if empty) answer and
gates the entity off like any other missing field. Updated the energy
meter, self-check error, cooktop burner, and range-hood auto-operation
exists_fn call sites, plus three golden fixtures that had baked the
phantom-entity behavior in as "expected".
2026-07-28 02:57:30 +00:00
Marc Billow 9011f84787 Model after_run_progress as a percentage, fix Dutch after-run-progress name
runningProgress's own field name states its domain, so restore unit='%' and
state_class='measurement' rather than leaving it an opaque passthrough --
that hedge made sense for activationState (no supported-values list, no
write contract to invent) but not here, where the name itself is the
evidence.

"Nadraaien voortgang" also wasn't idiomatic Dutch (nouns don't stack that
way); "Voortgang nadraaien" matches how the rest of the catalog compounds
these names.
2026-07-28 02:29:01 +00:00
Marc Billow 0640ac3477 Fix hotwater_lock key-collision hazard, address Opus review of triage fixes
An Opus review of the previous commit found that giving the switchHotwater
fallback and LOCK.hotwater_lock the same key introduced a real bug:
adapter.flatten() (the source of coordinator.data, which every switch's
is_on reads) only ever honours exists_fn, never entity.py's implicit
own-field-presence default that gates plain registration. With only one
side of the pair gated, both descriptors still wrote the same key into the
flattened state dict, and whichever was processed last -- decided by
device-reported href order, not correctness -- silently won. Reproduced
with the existing coffee fixture: reversing resource order flipped
hotwater_lock from correct (False) to a stuck True.

Fixed by gating both sides symmetrically via a shared tri-state helper that
also treats an unfetched /status/lock/vs/0 stub as "outcome pending" rather
than "confirmed absent" -- otherwise the stub window let both descriptors
pass exists_fn at once, which would have registered two switch entities
with the same unique_id. The fallback also re-asserts its own field's
presence, a check it used to get for free before it shared LOCK's key.

Also addresses two smaller findings from the same review, both in the
range-hood after-run capability (#147): runningProgress's unit='%' was a
guess from a single "0" sample with no supported-values/range field to
confirm the domain -- inconsistent with treating activationState as
read-only for the same "don't guess" reason -- so it's now a bare
passthrough sensor; and entity_category='diagnostic' was dropped from the
two read entities since after-run is a feature the user actively watches
and cancels via the (correctly uncategorized) button, not passive
diagnostics.
2026-07-28 02:25:42 +00:00
Marc Billow cc3ce12aa4 Fix range hood fan power targeting and kimchi mode write validation
- _speed_zero_is_off now keys off the hood resource's own
  settableMinFanSpeed/supportedFanSpeed fields instead of asking whether
  the device has any power resource at all, so a combi appliance's cavity
  /power/0 can no longer be toggled off by turning off just the vent fan.
- async_turn_on() no longer resets an already-running fan to its lowest
  speed when called without a percentage.
- _has_separate_power() reads through the O(1) resource cache instead of
  copying the full resource snapshot on every property access.
- _kimchi_mode_write rejects values the compartment didn't advertise in
  supportMode instead of writing them blind.
- kimchi_ripening_status no longer lowercases its value, since it has no
  enum catalog entry to translate the lowercased token back through.
- Documented why KIMCHI_DOOR_GENERIC isn't deduped against the /doors/vs/0
  aggregate fallback on the one fixture that reports both.

Adds regression tests for the combi-appliance power targeting, the
already-on turn_on no-op, kimchi mode write validation, and a kimchi
select display/write casing round-trip; a translation-coverage guard for
kimchi_zone_mode codes mirroring the existing AC preset one.
2026-07-28 02:10:01 +00:00
Marc Billow 5055d6bb72 Fix water-purifier hot-water lock mislabel, add range-hood after-run support
Water purifier (#144, #145): /favorite/hotwater/vs/0's switchHotwater field
is a Locked/Unlocked hot-water lock, not a "favorite enabled" flag. It's the
same lock as LOCK.hotwater_lock, just surfaced through this href on boards
that don't populate /status/lock/vs/0's hotwaterLock -- the two now share
the hotwater_lock key/translation, gated so only one is ever active.

Range hood (#147): binds /afterrun/vs/0 (after-run activation state,
progress, and a cancel button), clearing the last unbound href for
AHD-WW-TP1-22-COMMON.
2026-07-28 02:00:57 +00:00
Marc Billow 265d94eded Add kimchi-refrigerator compartment coverage (issue #26)
TP2X_REF_20K-class 3-compartment kimchi refrigerators report each
compartment's storage mode and ripening status/timer on
/status/kimchi/<slot>/vs/0, plus a top-compartment door sensor on
/kimchidoors/top/vs/0 -- all previously unbound. Bind them as pattern
capabilities (fridge.KIMCHI_ZONE, fridge.KIMCHI_DOOR_GENERIC), deriving
the per-compartment entity key and display name from the href's
top/middle/bottom segment, the same way DOOR_GENERIC/TEMP_CURRENT_GENERIC
already do.

Storage-mode option labels were translated directly from the reporter's
own SmartThings app screenshots rather than guessed from the raw device
codes or their English paraphrase, confirming the on-screen option order
matches supportMode's array order (including the freezer triplet's
-19/-21/-17°C -> Standard/Strong/Weak mapping).

Also tighten FLEX_ZONE's exists_fn: this device's /mode/vs/0 also
populates modes/supportedOptions, but with a token shape that never
overlaps (a "_[n]:[n]" suffix supportedOptions carries that modes never
repeats), so the existing "supportedOptions is nonempty" check let the
entity bind anyway and get stuck permanently on "unknown". Requiring an
actual resolvable value keeps it working for the RF9000/Bespoke-class
fridges it was built for while leaving it absent here.
2026-07-28 00:35:21 +00:00
Marc Billow e9281aaead Bind microwave built-in vent fan's /hood/fanspeed/vs/0 (issues #137, #142)
Combi microwave units report their vent fan on the same resource shape a
standalone range hood uses, so reuse range_hood.HOOD_FAN directly in the
microwave registry. Unlike a standalone hood, this board has no sibling
/power/0 or /power/vs/0 resource, so LocalThingsRangeHoodFan now falls
back to treating fan speed 0 as the off state when no separate power
resource is present. Also gate HOOD_FAN's automatic_operation sensor on
field presence, since this board doesn't report it.
2026-07-28 00:18:38 +00:00
Marc Billow 5af9d951c6 Simplify README microwave row label 2026-07-27 22:05:54 +00:00
Marc Billow a1f14cd633 Split microwaves into their own device type instead of the oven registry
Microwaves (combi and plain) were routed onto the oven registry (issue
#121), which meant entities carried oven-flavored keys (oven_state,
oven_mode, oven_setpoint) and inherited oven-specific behavior that's
wrong for this family: a 30-270C setpoint range instead of this family's
actual 40-200C, a cooking-mode list missing MicroWave/MicroWaveGrill/
MicroWaveConvection/KeepWarm entirely, and a lamp switch that read/wrote
the oven's 'UpperLamp' option token instead of this family's 'Lamp' token.

Adds a microwave device type (by_type/microwave.py,
capabilities/microwave.py) that reuses the oven board family's shared
operational-state/door/connected/recipe-cook capabilities but defines its
own cooking-mode, setpoint, and cavity capabilities with the corrected
bounds/vocabulary, plus a new power_level sensor for the cavity's Watt
setting that was previously unexposed.
2026-07-27 22:05:54 +00:00
Marc Billow 2be742489b Fix airflow fan power-href preference and unique_id collision risk
Opus review of the previous commit caught two real bugs. The airflow fan's
power writes preferred /power/vs/0, copied from the TP1X fan class -- but
that order is only harmless there because TP1X never reports /power/0 at
all. This family's dumps carry both hrefs, and the power_switch entity is
unconditionally bound to /power/0 when present, so the fan was writing to
a different resource than power_switch reads/writes, leaving the two
entities disagreeing until the next poll. Flipped to prefer /power/0,
matching the range hood's fan and common.POWER_GENERIC.

Also renamed the new FanDesc's key from 'fan' to 'airflow_fan': BoundEntity
unique_ids are derived from key alone, not href, so it collided with
air_purifier.FAN's own 'fan' key on the (currently unobserved, but
unenforced) possibility of a board reporting both.

Added a platform-level test file covering the power-href preference and
percentage<->speed-code mapping, mirroring test_range_hood_fan.py's harness.
2026-07-27 21:48:23 +00:00
Marc Billow d4583b3240 Add real fan-speed control for ARTIK051_TVTL air purifiers (issue #56)
/airflow/0's speed was left read-only because the first round of diagnostics
wasn't conclusive (0 for both Auto and High, 3 for Low/Medium and Sleep) --
likely because all five dumps were captured within about a minute of each
other, faster than this integration's own poll cycle could settle each
change. A second round, captured 60-90s apart per setting on two independent
units, confirmed a clean monotonic 0-4 mapping across Auto/Sleep/Low/Medium/
High instead.

Builds an ordered-speed fan off that confirmed range, the same SET_SPEED
shape as the range hood's fan -- this board never self-reports a
supportedModes-style label list, so there's no named-preset table to
preserve, just percentage steps over the raw code. /airflow/vs/0's vendor
speedLevel stays a read-only fallback since it was unreliable in that same
second round.
2026-07-27 21:32:44 +00:00
Marc Billow 7c68d478af Bump version to 0.13.0 2026-07-27 14:54:26 +00:00
Marc Billow e9eb38740d Deduplicate ISO-timestamp parsing and document the new device type (review follow-up, issue #131)
- vacuum_station._parse_iso_utc was a verbatim copy of
  water_purifier._parse_iso_utc; promoted to common.parse_iso_utc and
  pointed both families at it. Also made it tzinfo-aware rather than
  unconditionally overwriting with UTC -- harmless today since every
  dump seen is a bare or Z-suffixed UTC timestamp, but a board that
  ever emits a real offset would otherwise have it silently clobbered.
- Added the new vacuum_station type to the README's supported-appliance
  table, and noted that combi microwaves route through the oven
  registry.
2026-07-27 14:43:02 +00:00
Marc Billow f37c9ec4ef Fix air-purifier fan power write and silent preset-mode rejection (review follow-up, issue #130)
- The fan's power write hardcoded /power/vs/0 while is_on already read
  /power/0 as a fallback -- a board reporting only the OCF resource
  would show correct state but silently no-op on every turn-on/off.
  Mirrors LocalThingsRangeHoodFan's existing _power_payload pattern:
  target whichever power href the board actually reports.
- async_set_preset_mode fell off the loop silently on an unmatched
  mode with no log and no error, unlike the rest of this codebase's
  write-rejection handling. Logs a warning now.
- Deduplicated HEPA_FILTER's usage-percent calculation, which was an
  inline reimplementation of airconditioner._filter_usage_percent;
  promoted the shared logic to common.filter_usage_percent and pointed
  both families at it.
- Gave air_purifier.SOUND_MODE its own translation_key instead of
  defaulting to the same catalog entry laundry.SOUND_MODE uses. That
  entry's state table is {voice, tone, mute}; this board's is
  {mute, buzzer} -- sharing it left 'buzzer' with no label.
2026-07-27 14:42:34 +00:00
Marc Billow d26e7b957b Fix unreachable reconnect-warning threshold (review follow-up, issue #119)
The 60s/5-reconnect window from the original fix could never actually
fire: consecutive reconnect attempts are never closer together than one
summary poll interval (30s) plus the 5s reconnect pause, so at most ~2
timestamps can ever land inside a 60s window regardless of how unhealthy
the connection is. That silently downgraded every reconnect to INFO
permanently, including the persistently-broken case the change was
supposed to still surface at WARNING.

Widen to a 300s window with a threshold of 3, which is reachable under
sustained failures and still a reasonable proxy for the README's
"actually broken" case.
2026-07-27 14:41:43 +00:00
Marc Billow 8b44fd5710 Add device support for the stick-vacuum clean/auto-empty station (issue #131)
A-VSKR-TP1-22-VS9500AL connects successfully but its dump shows no
vacuum-body state at all -- no suction level, no battery, no cleaning
mode -- only the clean/auto-empty station's own dustbag, dustbin
auto-empty settings, and UV-C sanitizing-cycle status. This strongly
suggests the WiFi/DTLS module lives in the station, not the handheld
stick, so the station is the only "device" this integration's local
API can reach at all.

New vacuum_station device type (these hrefs share nothing with any
existing family, so there's no shared-href ambiguity to resolve
against another type) routed via a new '-VSKR-' modelNum fallback.
Binds with zero unbound hrefs: dust-bag full/usage sensors, auto-empty
and dustbin auto-close switches, a discharging-time select, and
clean-station status including UV-C intensive mode, operation time,
and finished/emitted timestamps. A couple of fields with unconfirmed
exact semantics (stick_status, dustbag_usage's unit) are exposed as
plain diagnostic values rather than an asserted binary/percentage
meaning.
2026-07-27 14:11:06 +00:00
Marc Billow 4e1eb7d03d Add fan-mode control for TP1X_DA-AC-AIR air purifiers (issue #130)
This newer board family reports fan modes (Smart/Max/Mid/WindFree/Sleep)
directly on /mode/vs/0's top-level modes/supportedModes fields, unlike
the older ARTIK051_TVTL family this registry already supported, which
packs everything into an options[] array with no usable fan-speed
selector at all (see the module docstring's Comode_Off finding). Both
board generations share the /mode/vs/0 href, so the existing MODE
capability and a new FAN capability are discriminated by a match_fn
checking for the top-level supportedModes field, rather than adding a
new device type.

The fan entity only exposes PRESET_MODE, not an ordered percentage --
WindFree/Smart/Sleep are named behaviors, not "faster/slower" positions
relative to Max/Mid, matching how the AC family's own named convenient
modes are modeled as a preset rather than a speed number.

Also picked up the rest of this board's previously-unbound hrefs while
in there (display, HEPA filter, panel status, pet-filter mode, sound
settings), reusing airconditioner.DISPLAY_LIGHT and
airconditioner.MUTE_ONCE for the two hrefs identical to the shared
DA-AC- board family, since the "incomplete capability coverage" repair
was firing on more than just the fan gap the issue described.
2026-07-27 14:08:32 +00:00
Marc Billow e44fef7085 Route combi microwaves onto the existing oven registry (issue #121)
TP1X_DA-KS-MICROWAVE-01041 (MW7300B) reports no oneUiVersion and an
unrecognized consumer token, so it fell back to 'unknown' and only got
common capabilities. It shares the same '/oven/vs/0' cavity resource
and '/mode/vs/0' cook-mode shape (Convection/AirFryer/Grill/MicroWave*)
as the wall oven already supported, so this reuses that registry via a
new '-MICROWAVE-' modelNum fallback rather than adding a new device
type. The only href it didn't already cover was /recipe/cook/vs/0, an
empty quick-recipe-display blob bound with no entity per the 'don't
guess' rule.
2026-07-27 13:41:36 +00:00
Marc Billow 6f10a3b796 Support 2-axis wind oscillation and overload-protection status on newer WindFree boards (issue #126)
Newer TP1X_DA-AC-RAC-01011_0000 firmware (Bespoke AI WindFree Deluxe,
AR60H10D1JWNME) drops /wind/direction/vs/0 entirely and reports swing
via a separate vertical/horizontal Swing|Fix pair on
/wind/oscillation/vs/0 instead, which left swing_mode/swing_modes
silently empty and the href unbound. climate.py now falls back to the
oscillation resource when /wind/direction/vs/0 is absent, mapping the
same off/vertical/horizontal/both vocabulary the existing swing control
already uses.

Also binds the board's /anomalyload/vs/0 overload-response resource as
read-only diagnostic sensors (operation state + mode) -- the same
"don't guess" precedent as the existing CURRENT_LIMIT capability, since
nothing in the dump confirms the exact behavioral difference between
its 'Alarm' and 'PowerSaving' modes or whether toggling it is safe on
live HVAC hardware.

Most of the other gaps this issue reported (Fan-only mode, WindFree
preset labels, target-temperature channel selection, power on/off via
the vendor resource) turned out to already be fixed by the just-merged
cool-only global RAC work.
2026-07-27 13:41:04 +00:00
Marc Billow 2c8a765036 Downgrade a lone poll-failure reconnect to info (issue #119)
Samsung's firmware occasionally drops the DTLS session briefly --
normal appliance-side behavior per the README's "Known device
behavior" section -- so the coordinator recovering from that on its
own doesn't need a WARNING. Only escalate once reconnects pile up
within a trailing 60s window (5+), matching the README's own "more
than a handful per minute" definition of an actually broken
connection.
2026-07-27 13:40:32 +00:00
Marc Billow f62b4aeec8 Detect ARA-WW-TP1-22-COMMON wall-mount RACs as airconditioner (issues #115, #116, #117, #120)
AR10/13/18BYEAAWKNME report no oneUiVersion and no '_RAC_'/'-RAC-'
token at all, so for_device_by_model() fell through to 'unknown' and
every href went uncovered. The board carries the same TP1X-class
resource surface as every other room AC already supported (mode/
convenient/wind/temperature/power/filter/humidity), so this reuses the
existing airconditioner registry via a new 'ARA-WW-' modelNum fallback
rather than adding a new device type -- confirmed against all four
reporters' dumps binding cleanly with zero unbound hrefs.
2026-07-27 13:40:12 +00:00
Marc Billow 46dd91ce32 Add regression coverage for NE8300D range (issue #112)
TP1X_DA-KS-RANGE-0102X already resolves via the '-RANGE-' modelNum
fallback and /cooktopmonitoring/vs/0 already binds through
range.COOKTOP_MONITORING, so this model binds with zero unbound hrefs
today -- add a fixture to lock that in.
2026-07-27 13:39:51 +00:00
Marc Billow 085e80c92c Add regression coverage for WA55A7700AV washer (issue #111)
The DA_WM_TP1_21_COMMON board family already routes through the 'WA'
consumer-model-prefix fallback and binds cleanly against the washer
registry with zero unbound hrefs, but no fixture locked that in for
this specific board generation -- add one.
2026-07-27 13:39:30 +00:00
Marc Billow 5547c401ed Address independent review findings on the RAC finish-up branch
- Pin the FAN_ONLY reverse-write fallback to 'Wind' (the original single
  spelling) instead of letting it silently flip to 'Fan' just because
  'Fan' was added second to the dict -- _device_code_for_hvac() resolves
  the code from a unit's own supportedModes first, so this dict is only
  a fallback for a unit reporting none at all, and that fallback
  shouldn't change behavior as an unintended side effect of insertion
  order.
- Add direct tests for _preset_to_ha() (pure function, previously
  untested) and the FAN_ONLY fallback pin.
- Cross-reference the AC family's inverted Light_On/Light_Off polarity
  against air_purifier.py's plain-polarity use of the same token name on
  the same resource name, so a future refactor doesn't assume they're
  the same thing.
- Fix a one-column continuation-line misalignment and a stale PR-number
  reference in a comment.
2026-07-27 05:11:58 +00:00
Marc Billow fa8f1b8675 Add cool-only global RAC support: WindFree, Auto mode, display light
Finishes PR #91's contribution (pedroperosin) with the requested review
changes applied, on our own branch:

- Preset resolution is now fully dynamic, read from each unit's own
  /mode/convenient/vs/0 supportedModes instead of a static per-model
  table -- any board's convenient modes (including WindFree's Nano/
  NanoSleep) surface without code changes. Unlabelled codes across
  existing fixtures (longwind, motionindirect, motiondirect, drycomfort)
  plus the two new WindFree ones are added to en.json/nl.json.
- 'Auto' now maps to HVACMode.AUTO instead of HEAT_COOL: these are
  single-setpoint "device decides" units, not two-setpoint heat+cool
  ones. 'Fan' is added alongside 'Wind' as a second FAN_ONLY spelling;
  a new _device_code_for_hvac() picks the code from the unit's own
  supportedModes since the flat map can't disambiguate two device codes
  mapping to one HA value.
- Detection gains a hyphenated '-RAC-' modelNum fallback (alongside the
  existing '_RAC_') for cool-only global RAC variants whose
  /otninformation/vs/0 ships no swVersionInfo block.
- Adds a display_light switch sourced from /mode/vs/0's opaque options
  blob (inverted Light_On/Light_Off token) for boards with no dedicated
  /light/vs/0 switch.

Write-path behavioural change (touches the path iterated on across
#9/#17/#27/#38/#54): power now targets the vendor /power/vs/0 instead of
the OCF /power/0, and _is_on() reads vendor-first. /power/0 is absent on
several known AC boards, so the previous OCF-first read/write pair could
report and act on stale state -- consistent with #53's "can turn on but
not off". Target temperature now picks its channel (OCF pair vs. vendor
items[]) based on which the unit actually reports, reading and writing
the same one.

The vendor temperature write and the new display-light write both carry
only the changed field(s), not the whole resource -- confirmed sufficient
on the wire, the device merges the rest itself. That requires the
coordinator's optimistic cache to do the same merge on the read side so a
setpoint change doesn't blank out current/min/max/unit for the settle
window: common.py gains merge_items_field() next to the existing
merge_options_field(), and async_send_command wires it in for any write
touching x.com.samsung.da.items.

New fixture/golden for the cool-only global RAC variant (TP1X_DA-AC-RAC-
01001, AI_RAC_GLOBAL_COOLONLY_3.0); display_light added to the goldens
for boards that gain the new options-based switch. Regenerated against
current main rather than copied from the original PR, since those
goldens had already shifted (current_temperature_c/humidity from issue
#75).
2026-07-27 05:00:06 +00:00
Marc Billow 35775c3d4a Add coffee-maker capabilities to the water purifier registry (issue #107)
Some TP2X_WATERPURIFIER_20K units are coffee-capable and expose five
resources issue #90's original dump never had:
/favorite/coffee/vs/0, /favorite/hotwater/vs/0,
/brand/recipe/info/vs/0, /coffee/custom/recipe/vs/0,
/recipe/coffee/vs/0, and /recipe/coffee/deletion/vs/0.

Adds FAVORITE_HOTWATER (a switch + select pair on
/favorite/hotwater/vs/0, mirroring the existing FAVORITE_CAPACITY
pattern) and COFFEE (a switch + status sensor on
/favorite/coffee/vs/0). The remaining four hrefs are static
capability-advertisement blobs or empty on every dump seen so far --
no live "current recipe" or "current custom slot" field to expose --
so they're added to the ignored coverage list per the 'don't guess'
rule rather than modeled speculatively.

Confirmed against the issue #107 diagnostics dump with zero unbound
hrefs.
2026-07-27 04:19:19 +00:00
Marc Billow 8ac1d11d17 Add WA (top-load washer) consumer-model prefix (issue #106)
WA8000T reports no oneUiVersion and used the 'WA' consumer-model
prefix, unmapped in _CONSUMER_PREFIX_TO_KEY (only WW/WD/WF/WV were
covered), so it fell into the unknown-device-type fallback.

Adding a bare 'WA' entry collided with the unrelated '_WAC_' (Window
Air Conditioner, issue #87) board-family token: some devices report
description == modelNum, so 'WAC' shows up as its own description
segment and 'WAC'[:2] == 'WA' matched the new washer prefix before the
more specific '_WAC_' modelNum check ever ran. Fixed by reordering
for_device_by_model() to check board-family modelNum tokens first and
the fuzzier 2-letter consumer-model-prefix scan only as a fallback,
rather than patching the prefix matching itself (an earlier attempt --
requiring a digit immediately after the prefix -- broke issue #79's
real DVE50A8800 case, which has no digit there either). Added a
regression test pinning the WAC/WA disambiguation directly.

Confirmed against the issue #106 diagnostics dump with zero unbound
hrefs.
2026-07-27 04:15:08 +00:00
Marc Billow 634f367e96 Merge remote-tracking branch 'origin/main' into claude/device-support-issue-86-cooktop
# Conflicts:
#	custom_components/localthings/registry/by_type/__init__.py
2026-07-27 04:04:19 +00:00
Marc Billow f31cee206b Merge remote-tracking branch 'origin/main' into claude/device-support-issue-77-freezer
# Conflicts:
#	custom_components/localthings/registry/by_type/__init__.py
#	tests/test_by_type.py
2026-07-27 04:03:38 +00:00
Marc Billow 8628ae6864 Merge remote-tracking branch 'origin/main' into claude/device-support-issue-86-cooktop
# Conflicts:
#	custom_components/localthings/registry/by_type/__init__.py
#	custom_components/localthings/translations/en.json
#	custom_components/localthings/translations/nl.json
2026-07-27 04:00:15 +00:00
Marc Billow 38263eaa72 Merge remote-tracking branch 'origin/main' into claude/device-support-issue-88-dehumidifier
# Conflicts:
#	custom_components/localthings/registry/by_type/__init__.py
#	tests/test_by_type.py
#	tests/test_golden_regression.py
2026-07-27 03:58:53 +00:00
Marc Billow ff6e1ecff4 Rename gas cooktop registry's display name to avoid induction_cooktop confusion
Renames DeviceRegistry.name from 'cooktop' to 'gas_cooktop' for the
NA9300K-class gas-cooktop registry (PR #23), so diagnostics/device-info
labels no longer collide with the unrelated induction_cooktop family
(issue #86) -- two different OCF surfaces that happen to share the
English word "cooktop".

Safe rename: _REGISTRY_BY_KEY's 'cooktop' lookup key is unchanged, so
all three existing detection paths (oneUiVersion "Cooktop" exact
match, the legacy ARTIK051 modelNum rule, and the resource-signature
fallback) keep routing real devices exactly as before. Entity
unique_ids are built from device serial + entity key, not registry
name, so existing entities are unaffected. Only the DeviceInfo.name
and diagnostics device_type strings change, both cosmetic.
2026-07-27 03:56:32 +00:00
Marc Billow 78f1bb0f92 Fix unclosed PROBE_STATUS capability from a bad merge conflict resolution
The merge of main into this branch dropped PROBE_STATUS's closing
),\n) and glued issue #74's COOKTOP_MONITORING addition directly onto
its entities tuple, leaving an unclosed paren (SyntaxError on import,
breaking Pytest and Hassfest CI). Restores the closing parens; no
functional change.
2026-07-27 03:46:55 +00:00
Marc Billow 5e60f9b953 Fix stale Window AC golden fixture (current_temperature_c, humidity)
PR #75 (WindFree AC) added CURRENT_TEMPERATURE/HUMIDITY capabilities
to the shared airconditioner registry, which every AC device picks up
-- including the Window AC from PR #87. Both branches built their
golden fixtures independently against their own base commit before
either landed, so neither saw the other's addition; once both merged,
the Window AC's fixture went stale. The two extra keys are real,
working sensors from #75's work, not a regression.
2026-07-27 03:45:32 +00:00
Marc Billow 45931332d4 Rework AIComfort as an HVACMode.AUTO + preset overlay, add unmapped-mode warning (issue #93)
AIComfort isn't a distinct thermodynamic operation like Cool/Dry/Heat --
it's an AI-driven overlay on top of the device's own 'Auto' behavior,
confirmed by A-CAWW-TP2-20-COMMON reporting both 'Auto' and 'AIComfort'
as separate, mutually-exclusive entries in /mode/vs/0's supportedModes.
Modeled the idiomatic HA way instead of a flat _DEVICE_TO_HVAC entry:
hvac_mode reports AUTO and a new 'ai_comfort' preset carries the
distinction. Entered/left only via the preset (writes the primary mode
resource, not the convenient one) -- there's no dedicated HVACMode
value for it, so it's not offered in the hvac_mode dropdown directly.

Also adds a once-per-(href, code) warning log when a device-reported
mode has no entry in the relevant map, so a future gap like this one
surfaces in the log instead of silently vanishing -- the exact failure
mode issue #93 called out ("this class of gap is invisible without
diffing against supportedModes").
2026-07-27 02:01:51 +00:00
Marc Billow 8c3250b163 Map AC's AIComfort mode to HVACMode.AUTO (issue #93)
A-CAWW-TP2-20-COMMON (and likely other CAWW/TP2X-class boards) reports
'AIComfort' as a distinct entry in /mode/vs/0's supportedModes,
alongside 'Auto' (already mapped to HEAT_COOL). _read_modes() silently
drops any code missing from _DEVICE_TO_HVAC, so AIComfort was
unreachable -- one of HA's five other AC hvac_modes, unused by this
device family until now.

The other two gaps in issue #93 are already addressed elsewhere and
not duplicated here:
- Fan-only via the 'Fan' device code, and the WindFree/LongWind/
  NanoSleep preset codes, are covered by the still-open PR #91, which
  replaces the static preset table with a fully dynamic resolver over
  the device's own supportedModes.
- The 'Left_And_Right' -> horizontal swing mapping is already on the
  still-open claude/device-support-issue-75-windfree-ac branch.
2026-07-27 01:43:22 +00:00
Marc Billow d53459d047 Add device support for Samsung water purifiers (issue #90)
The TP2X_WATERPURIFIER_20K water purifier reports no oneUiVersion and
its modelNum/description don't match any consumer-prefix or existing
board-family token, so it fell into the unknown-device-type fallback
with only common capabilities. Add a new water_purifier registry,
routed via a 'WATERPURIFIER' modelNum/description fallback rule.

Models dispense settings (type/temperature/capacity/pouring status),
sterilize and filter status, favorite-capacity presets, and the three
water/buzzer locks. Per the adding-device-support skill's "never
hard-code the one dump's values" rule: dispense-capacity bounds and
step come live from the device's own desiredCapacityRange/
capacityResolution fields (range_field/step_fn), not a hardcoded
constant, and the hot-water-temperature control is a select over the
live supportedHotTemperatures list rather than a number with invented
bounds, since only a few discrete temperatures are selectable.

/mode/vs/0 and /automation/waterpurifier/vs/0 are left unmodeled: the
former carries an opaque wizard-workflow token with no coherent
current-value contract, the latter is a static support-flags blob with
no live setting to expose.

Confirmed against the issue #90 diagnostics dump with zero unbound
hrefs. Updates the README's supported-appliance-types table for the
new device type.
2026-07-27 01:40:05 +00:00
Marc Billow 89429039fb Add device support for Samsung dehumidifiers (issue #88)
The AY18CG7500GED dehumidifier (modelNum TP1X_DA_AC_DHM_01001_0000)
shares the DA_AC_ board family with the room-AC models but carries the
'_DHM_' token instead of '_RAC_'/'_PRAC_'/'_WAC_', so it fell into the
unknown-device-type fallback. Add a new dehumidifier registry, routed
via a '_DHM_' modelNum fallback rule, distinct from airconditioner
since target humidity (not temperature) is the primary control and
there's no climate composite.

Reuses airconditioner.py's AUTO_CLEAN/AIR_FILTER/MUTE_ONCE capabilities
directly (identical resource shapes on the shared board family). Adds
a new humidity sensor + target-humidity number pair and an
operating-mode select. Per the adding-device-support skill's
"never hard-code the one dump's values" rule, the target-humidity
number has no hardcoded min/max (falls back to HA's own 0-100 default
for a percentage field) and reads its step live from the device's own
`increment` field rather than a spec-sheet-derived constant. The
operating-mode select's options come live from supportedModes.

/mode/convenient/vs/0 is left unmodeled: only supportedModes is present
on this dump, with no live current-value field to confirm a read/write
contract.

Confirmed against the issue #88 diagnostics dump with zero unbound
hrefs. Updates the README's supported-appliance-types table for the
new device type.
2026-07-27 01:29:25 +00:00
Marc Billow b47eeaf7bc Add device support for Bespoke Window AC (issue #87)
The AW06C7155EWAZ window air conditioner (modelNum
TP1X_DA_AC_WAC_01001_0000) reports no oneUiVersion and uses the '_WAC_'
(Window Air Conditioner) modelNum token instead of the '_RAC_'/'_PRAC_'
tokens already handled by for_device_by_model. Add a fallback rule for
that token, routing it to the existing airconditioner registry.

The device's resource surface (mode/convenient/wind/temperature/power/
filter/humidity) is already fully modeled by the airconditioner
capability set, so this is purely a detection-routing fix -- confirmed
against the issue #87 diagnostics dump with zero unbound hrefs.
2026-07-27 01:17:45 +00:00
Marc Billow a453dc9ece Add standalone induction-cooktop support (issue #86)
TP1X_DA-KS-COOKTOP-01011 (NV8500T-/KO4) is the same board family and
/cooktop/status/vs/0 resource shape as issue #44's range combo, minus
the oven -- but its modelNum uses the hyphenated '-COOKTOP-' token,
which for_device_by_model's existing '_COOKTOP' check (underscore-
delimited, matching the unrelated NA9300K gas-cooktop family in
cooktop.py) doesn't match. The device fell back to 'unknown' with only
energy/alarms from the global fallback.

Add the hyphenated token check, routing to a new 'induction_cooktop'
registry (by_type/induction_cooktop.py) that reuses range.py's
COOKTOP_STATUS/COOKTOP_SPEC/COOKTOP_SAFETY/PROBE_STATUS and
cooktop.PAIRED_HOOD_STATUS wholesale rather than pulling in range.py's
oven capabilities, which this device has no hrefs for at all.

Along the way, three fields the reporter asked for turned out to be
gaps in the shared range.py capability itself, not just missing
routing -- also present (and previously unmodeled) on issue #44's
original combo-range dump:
- /cooktop/status/vs/0's own `power` and `childLock` fields (distinct
  from common.POWER's /power/0 or /power/vs/0, which a combo range
  additionally carries for the whole appliance) -- childLock gets a
  write_fn (a safe lock toggle, direct single-field PUT), power stays
  read-only (no live device to confirm a remote write wouldn't leave a
  burner active unattended).
- Each burner's `panDetection` field.

New: a Bluetooth meat-probe capability for /bluetooth/probe/status/vs/0
(read-only -- connection, battery, current/target temperature), and
/cooktop/recipe/status/vs/0 is ignored (every field empty on this idle
dump, same treatment as the microwave family's /recipe/cook/vs/0).

Regenerates the range golden fixture (gains cooktop_power/
cooktop_child_lock/burner_N_pan_detected) and adds a dedicated fixture
for the standalone cooktop.
2026-07-27 01:12:16 +00:00
Marc Billow 2c9fda3db1 Catch the 'Nothing(SVC)' placeholder serial in both fallback sites (issue #83)
The ARTIK051_DONGLE_REF firmware family reports the literal string
"Nothing(SVC)" as serialNum on every unit -- non-empty, so the existing
`if not serial` checks in config_flow.py's _probe_and_validate and
coordinator.py's _run_discovery don't catch it. Two such appliances on
one install (a fridge and a freezer, each its own dongle) then collide:
config_flow gives both the same unique_id and rejects the second as
"already configured" (bug 2), and even once that's worked around,
device_serial feeds every entity's unique_id too, so the second
appliance's entities get silently dropped with "does not generate
unique IDs" log lines (bug 4).

Add _is_placeholder_serial (duplicated in both modules rather than
imported, to avoid pulling config_flow into the runtime coordinator's
import graph or vice versa for a two-line check) and treat it the same
as an empty serial: fall back to host/port.

Type detection (bug 1) and the door sensor's field-name gap (bug 3),
also reported in this issue, are already fixed via the
claude/device-support-issue-77-freezer branch, which hit the same
ARTIK051_DONGLE_REF family from a different report -- not duplicated
here.
2026-07-27 01:00:05 +00:00
Marc Billow 5d7789eb4e Add confirmed washer/dryer cycle code labels (issue #80)
Five raw course codes were rendering unlabeled because no translation
entry existed for them, confirmed by the reporter selecting each cycle
on the physical appliance and reading back the raw code from the
entity's state:

- washer_cycle_table_02: '52' Eco Cold, '54' Towels, '60' Self Clean+
  (a WF50A8600AV/US). '54' shares a display name with the existing '24'
  Towels -- a different code on the same table legitimately landing on
  the same label, matching the existing '21'/'65' Colors and
  '27'/'5E' Rinse+Spin pairs, not a duplicate-in-error.
- dryer_cycle_table_03: '01' Normal, '06' Time dry (a DVE50A8600V/A3,
  the same model added in the previous commit's detection fix).

No code changes -- select.py already derives which raw values it
normalizes from the shipped catalog, so labelling a code is purely a
translations/en.json (mirrored to nl.json) addition.
2026-07-27 00:47:16 +00:00
Marc Billow bae1ac4337 Fix dryer detection when description pairs two model numbers (issue #79)
DVE50A8600V/A3 reports description
'DA_WM_TP1_21_COMMON_DVE50A8800_8600/DC92-02835A_0080' -- a paired
listing of two related model numbers (DVE50A8800 and DVE50A8600) joined
by an underscore, rather than the usual single trailing consumer-model
token. for_device_by_model only ever checked the literal last
underscore segment ('8600', which has no recognizable 2-letter prefix
on its own), so the real 'DV' token one segment earlier was never
reached and the device fell back to 'unknown' with only common
capabilities -- no dry level, cycle, or wrinkle-prevent entities.

Replace the single last-segment extraction with _consumer_model_key,
which scans segments from the end and returns the first one that
resolves. Behavior is unchanged for every existing single-token
description (the last segment still matches first); it just keeps
looking when that segment doesn't.
2026-07-27 00:44:23 +00:00
Marc Billow 643aac92f8 Lock in the same ARTIK051_DONGLE_REF fix for the fridge half (issue #78)
RR40M7165WW is the fridge half of the same household dongle setup as
issue #77's freezer -- identical pipe-delimited ARTIK051_DONGLE_REF
modelNum, so the previous commit's detection and door-sensor fixes
already cover it with no further code changes. Add its fixture as a
second, independent regression case: it exercises the 'cooler' instance
segment instead of 'freezer' for both the temperature pattern caps and
DOOR_GENERIC, and notably reports /door/onedoorfreezer/vs/0 despite
being a single-door fridge (shared firmware naming across the product
line, not an actual second compartment) -- worth having its own golden
so that stays working too.
2026-07-27 00:41:25 +00:00
Marc Billow 8194ea9e87 Fix ARTIK051_DONGLE_REF freezer type detection and door sensor (issue #77)
RZ32M713EWW/EE (an ARTIK051-dongle standalone freezer) reports no
oneUiVersion and a pipe-delimited modelNum
('ARTIK051_DONGLE_REF|<rest>') -- REF is the last underscore segment
before the pipe, not wrapped in underscores on both sides like the
'..._REF_...' shape for_device_by_model's substring check expected, so
the device fell through to 'unknown' with only common capabilities:
no door sensor, no temperature sensors, nothing fridge-specific.

Replace the substring check with a segment-based one
(_model_num_segments splits the pipe-delimited prefix on '_') that
catches both shapes. Same root cause, same fix, and same device family
independently reported and root-caused in issue #83 (which also covers
two further bugs -- config-flow/coordinator serial collisions on a
second symptom of this firmware, 'Nothing(SVC)' as a literal serial --
not needed here since this reporter has a single unit; left for #83).

Once routed to the refrigerator registry, fridge.py's existing pattern
capabilities pick up /temperature/current/freezer/0 and
/temperature/desired/freezer/0 for free -- they were never the actual
problem, just unreachable under the 'unknown' fallback (which never
tries pattern capabilities at all). The door sensor needed one more
fix: /door/onedoorfreezer/vs/0 reports the vendor-prefixed
x.com.samsung.da.openState, not the bare openState DOOR_GENERIC read,
so the entity existed but stayed permanently unavailable. Check both
field names via rep_fn.
2026-07-27 00:39:33 +00:00
Marc Billow 3afbe6c6c1 Add humidity/temperature sensors and horizontal swing for AC (issue #75)
Three gaps reported against an ARTIK051_PRAC_20K WindFree unit vs. the
SmartThings integration:

1. Missing WindFree/motion convenient-mode presets -- left alone here.
   PR #91 replaces climate.py's static _DEVICE_TO_PRESET table with a
   generic resolver that reads any preset code straight off the unit's
   own supportedModes, which already covers this (and more generically
   than a per-model dict would) -- adding one here would just conflict.

2. No horizontal oscillation: /wind/direction/vs/0's supportedModes
   includes Left_And_Right, which _DEVICE_TO_SWING had no mapping for.
   Add it to HA's standard 'horizontal' swing constant.

3. No standalone humidity/current-temperature sensors: the climate card
   already reads both internally, but nothing exposed them as entities
   for history/automations. Add CURRENT_TEMPERATURE (OCF
   /temperature/current/0) with a CURRENT_TEMPERATURE_VS vendor fallback
   (same match_fn-gated pair shape as common.py's POWER_GENERIC/
   POWER_VS_FALLBACK), and a HUMIDITY sensor reading /humidity/vs/0's
   fivepercentHumidity field -- the only one of the three
   humidity-shaped fields across /humidity/0 and /humidity/vs/0 that
   isn't permanently stuck at 0 on every dump seen.

Regenerates the five existing AC goldens (all pick up
current_temperature_c; most pick up humidity) and adds a dedicated
fixture from the issue's WindFree dump, whose /humidity/vs/0 actually
has live fivepercentHumidity data.
2026-07-27 00:33:35 +00:00
Marc Billow c72b5a988e Add range/oven detection for boards missing /information/vs/0 (issue #74)
NE63B8411SS reports no oneUiVersion and no /information/vs/0 resource at
all, so neither for_device nor for_device_by_model's modelNum tokens have
anything to key off -- it fell through to the unknown-device fallback,
which also mis-binds /temperatures/vs/0 against fridge.py's setpoint
capability (a collision the oven family's own capabilities are normally
excluded from the global registry specifically to avoid).

Add a resources-based signature to for_device_by_resources(): 'Bake' in
/mode/vs/0's supportedModes is oven/range-exclusive vocabulary, and paired
with the /oven/vs/0 cavity resource it reliably identifies this family
even with no model info at all. Route to 'range' when a cooktop-status
resource is also present, else plain 'oven'.

This board's cooktop half also doesn't expose the per-burner
/cooktop/status/vs/0 array range.py already models -- only the coarser
/cooktopmonitoring/vs/0 summary resource. Add a read-only
COOKTOP_MONITORING capability for it (cooktop running state, warming
center state) rather than leaving it unbound.
2026-07-27 00:23:04 +00:00
Marc Billow 35e2c79b14 brand: use updated localthing logo 2026-07-24 20:23:48 -05:00
Marc Billow f185951a8a i18n: missed a quick wash translation 2026-07-24 15:42:24 -05:00
Marc Billow adcb8a0ecb chore: add additional translations provided in #1 dutch 2026-07-24 15:33:31 -05:00
Marc Billow ee77e3bda8 chore: add additional translations provided in #1 2026-07-24 15:20:19 -05:00
Marc Billow ea986fe8e5 refactor: adopt cleaner write pattern for options arrays 2026-07-24 15:05:26 -05:00
Marc Billow 10c850f2b9 refactor(i18n): drop the vestigial descriptor name field
Since entity.py started routing named descriptors through the catalog
under desc.key, SamsungEntityDescription.name has been read for its
value nowhere -- only twice as a flag, to decide whether an entity was
translated at all. That left 148 English names duplicated between Python
and translations/en.json with nothing keeping them honest: six had
already drifted, invisibly, because editing the Python side changes
nothing a user sees.

So the field is gone, and translation_key defaults to desc.key. A
descriptor now sets translation_key only to share one catalog entry
across descriptors or to point at a differently-named one, and the
catalog is the only place an entity name exists.

Every descriptor resolves to exactly the translation key, icon, entity
category, enabled-default and gating it did before -- with one
deliberate exception: the hood fan, previously the sole descriptor with
no key at all, now resolves to 'fan'. That is inert, because fan.py sets
_attr_name = None so the entity presents as the device itself.

The three helpers that forwarded a name into a descriptor
(laundry.bool_option_switch, washer._bool_option_switch, air_purifier's
sensor table) lose that parameter. test_translations.py now requires a
catalog entry for every descriptor rather than only translated ones.

Claude-Session: https://claude.ai/code/session_01GiibJZZLWVvyxq7mc7EDNp
2026-07-24 19:45:37 +00:00
Marc Billow 6281b40549 refactor(i18n): make the shipped catalog the single source of truth
PR #68 restated its own translation data in Python: a 60-line
TRANSLATED_SELECT_STATES table of frozensets duplicating every
entity.select.*.state key, a second _TRANSLATED_COURSE_TABLES table
naming which course tables have translations, and a strings.json that
was a 835-line byte-for-byte copy of translations/en.json save 43
[%key:...%] references. Each needed hand-syncing, and one was already
drifting.

Home Assistant loads exactly one file per language for a custom
integration -- translations/<lang>.json. It never reads strings.json and
never resolves [%key:...%]; both belong to Core's build tooling, which
custom integrations don't run through (hassfest skips a missing
strings.json and validates translations/en.json instead). So en.json is
the source, and the new catalog.py reads the keys and states back out of
it for the two decisions Python genuinely has to make:

  - select._display() normalizes a raw Samsung option to a lowercase
    state key only when the catalog knows it, else leaves the vendor's
    casing alone. Derived sets are identical to the removed literals.
  - laundry.cycle_select() keys off a device-reported course table only
    when that table has an entry, else falls back to the name-only
    'cycle' key. Translating Table_00 is now a translations-only change.

Also fixes six names that had already drifted between the Python
descriptors and the catalog, restoring HA's sentence case for two
generic ones (Auto release dry, Bubble soak) and taking the catalog's
wording for the rest, and adds a test so the vestigial descriptor names
can't silently disagree with the UI again.

Claude-Session: https://claude.ai/code/session_01GiibJZZLWVvyxq7mc7EDNp
2026-07-24 19:32:09 +00:00
Marc Billow 0b6cc6aa9f Merge branch 'pr68' into claude/home-assistant-i18n-iwwyvr 2026-07-24 19:24:59 +00:00
Marc Billow c731ecefe5 feat: add debug options panel for arbitrary resource-href writes (#54)
Power users can now pick a resource href from a live dropdown, view its
current value, and POST a minimal patch straight to the device -- to pin
down device-specific write behavior without waiting on a new release.
Bypasses the remote-control block and all write_fn/validate_fn logic by
design; the existing remote-control settings toggle moves behind the same
options-flow menu.
2026-07-24 14:02:15 +00:00
Marc Billow 3b3dd54372 Simplify table-scoped translation key; fix stale resolution; correct docstring
Simplification (feedback: this was overcomplicated): drop the
validated_table gate entirely. cycle_select's table_href now just builds
the translation key directly from whatever course table the device
reports (washer_cycle + Table_02 -> washer_cycle_table_02) instead of
comparing against a hardcoded known-good value and falling back to no key
on any mismatch. A table we haven't shipped translations for yet (e.g.
FlexWash's Table_00) still gets a key built for it -- Home Assistant's own
missing-translation handling takes it from there, the same graceful
fallback already relied on for any individual untranslated code within an
existing table. Adding a newly-confirmed table later is just new
strings.json entries, no code change.

Independent (Opus) review of the prior version caught two real issues,
fixed here regardless of the simplification above:

- translation_key was resolved once at entity construction from whatever
  coordinator.last_resources held at that moment. Discovery can run while
  a sibling resource is still an empty stub (documented precedent: see
  _is_included), so a callable translation_key could permanently bake in
  a stale value for the entity's lifetime. Moved resolution into a
  translation_key property override (Entity.translation_key is a property
  upstream, not a plain attribute), re-evaluated against live coordinator
  data on every access, matching how options/current_option already work.

- The supportedOptions fallback's "smallest passing K wins" docstring
  claimed every larger passing K is an exact multiple of the true one.
  False: the shipped dishwasher fixture has passing K=7 (true) alongside
  10, 14, and 35, none of which are multiples of 7 -- position 0 always
  lands on the same real course code regardless of K, which alone
  satisfies the current-course guard for several unrelated splits.
  Corrected the reasoning to what's actually true (an empirically-matched
  heuristic across six real dumps, not a proof) and added a regression
  test locking in the real dishwasher case so this isn't silently lost.
2026-07-24 05:55:04 +00:00
Marc Billow b2c32a90b6 Scope washer/dryer cycle translations to the device's own course table
Course codes on the shared /course/vs/0 contract aren't guaranteed
consistent across board generations: washer/combo devices report course
table Table_02, dryer devices Table_03 (x.com.samsung.da.st.courseTable,
previously fully ignored), and every code in washer_cycle/dryer_cycle was
confirmed exclusively against those. FlexWash's older DA_WM_A51 board
reports Table_00 instead -- applying the same translations there risked
showing a wrong name for any code that happens to numerically collide
between tables, not just an untranslated one.

SelectDesc.translation_key can now be a callable (resources -> key or
None), mirroring the existing pattern for `options`. laundry.cycle_select
gains optional table_href/validated_table params: when given, the renamed
washer_cycle_table_02/dryer_cycle_table_03 keys only apply when the
device's own course table matches exactly -- a different table, or no
table id at all, gets no translation_key (raw code display) rather than
a guess. dishwasher's call site is unchanged (static key, unconditional):
no equivalent table-id resource exists in any dump seen, and no evidence
its course codes vary by table the way washer/dryer's do.

entity.py and select.py resolve a callable translation_key once (via
coordinator.last_resources) and reuse that resolved value everywhere
_display() needs it, rather than re-checking the raw descriptor field.
2026-07-24 05:42:12 +00:00
Marc Billow b2c0517115 feat: derive washer/dryer/dishwasher cycle list from supportedOptions when editCourseList is empty
Some DA_WM_TP1/TP2-class boards populate /wm/editcourse/vs/0 without ever
filling in editCourseList itself (issue #1), so the Cycle select never gets
created even though the device clearly has one (confirmed via SmartThings
app screenshots and a currently-selected course).

/course/vs/0's own x.com.samsung.da.supportedOptions turns out to already
carry the course list, just undocumented: a 1-hex-nibble header followed by
one fixed-width record per course, self-indexed by a course-code first byte
rather than positional like editCourseList. Confirmed against six
independent real-world dumps pulled from open and closed GitHub issues.

cycle_options() now falls back to deriving this when editCourseList is
empty, gated on two checks: the derived codes must all be distinct, and
must include whatever course is currently selected. Larger multiples of
the true record width trivially re-pass both checks too (they're just a
sparser sampling of the same table), so the smallest passing width wins
rather than requiring one unambiguous match.

Also fires on the washer_flexwash fixture, newly creating a Cycle select
there -- unconfirmed against any ground truth for that device (a different,
older board generation with no editCourseList and no screenshots to check
against), flagged for follow-up discussion rather than silently accepted.
2026-07-24 05:06:39 +00:00
Marc Billow 39dcf6a7b8 Drop unexplained Blooming_* diagnostic, confirm remaining air purifier fields (issue #56)
Per the five running-state diagnostics dumps (Auto/Sleep/Low/Medium/High)
gathered in the issue thread:
- Blooming_* has no corresponding SmartThings app setting, so it's dropped
  entirely rather than kept as an unexplained diagnostic.
- Comode_* reads 'Off' on all five, ruling out the original guess that it
  was the fan-speed selector -- still exposed read-only, purpose unconfirmed.
- OptionCode_60282 and the missing humidity sensor are confirmed correct as
  already modeled.
- /airflow's speed doesn't map monotonically to the five settings and the
  dumps were all captured within one ~30s poll cycle of each other, so it
  stays read-only pending a cleaner, time-spaced capture.

FilterProgress is untouched here: an earlier pass on this issue read the
thread as confirming 100 means "fresh" and renamed the sensor to filter_life
to match, but that reading was backwards -- the reporter clarified 100
means fully used and needs replacing, which is what filter_progress (the
already-shipped name) already implies. That rename was caught before
merging and is not part of this change.
2026-07-24 04:20:42 +00:00
Marc Billow efe87381b7 Bump version to 0.11.1 2026-07-24 04:06:31 +00:00
Marc Billow 8e25e6dc71 Recognize A-CAWW-TP2-20-COMMON system air conditioners (issue #52)
New '-CAWW-' modelNum token for multi-indoor-unit commercial AC
installs -- these report no oneUiVersion, same as the other RAC/PRAC
boards. Once routed to the existing airconditioner registry, every
resource in the reporter's dump already binds except one new
SAC-specific installation-topology blob, now ignored.
2026-07-24 04:06:31 +00:00