Commit Graph
139 Commits
Author SHA1 Message Date
Marc Billow ccdfe7088e Merge pull request #281 from atc722/agent/nv9000d-regression-fix
Fix read-only sensor categories and add NV9000D coverage
2026-08-04 21:40:03 -04:00
Marc Billow b59b5ae1b4 Merge pull request #290 from perseus177/ac-autoclean-stop
feat(airconditioner): stop a running auto clean, and read its progress
2026-08-04 20:53:44 -04:00
perseus177 290a348017 feat(airconditioner): stop a running auto clean, and read its progress
Three tokens describe the drying cycle these boards run after cooling, and the
switch only covered the first. AutocleanProgress_ is how far a running cycle
has got, and StopAutoClean_ is a channel for ending one early -- its presence
is what says the appliance accepts that at all, which is how the appliance's
own app gates its stop button. Both tokens are reported by the ARTIK051_KRAC_18K
that issue #136 was about, and by every KRAC fixture here.

The percentage scale is the app's own: it renders the token into a
`<progress max="100">` with a "{{value}}%" label beside it. An idle unit reports
1 rather than 0 -- the same floor the laundry firmware's progressPercentage sits
at when Ready -- so 0-vs-1 is not a reliable "is it running" test, and the
button is deliberately not gated on it.

The sensor shares AUTO_CLEAN's catalog entry the way auto_clean_legacy already
shares the switch's: same figure, different board generation, distinct key so
nothing collides if a board ever reported both.

Stacked on #289 (this branch is cut from it) -- rebase or merge that first.
2026-08-05 00:45:20 +02:00
hoon 3d0dca20f9 Add NV9000D cooktop coverage and fix sensor setup 2026-08-04 14:47:42 +09:00
kkqq9320 412fff9b99 feat(air_purifier): expose the AI Purify sensing engine on /airlevelcheck/vs/0
/airlevelcheck/vs/0 has been covered as "periodic air-quality sensing
scheduler plumbing" since the registry gained a coverage stub for it. Two
AVT-WW-TP1-23-AXX500 dumps (issues #84 and #190) show it is not plumbing: it
drives the feature the SmartThings app calls AI Purify, where the unit wakes
on a timer, samples the air, and optionally acts on the result. Every field
is named, none are opaque, and two of them are already user-set on the
reported units.

The select's three on-states are the app's own options rather than an
invented grouping -- it offers exactly "Sensing only" (sample, take no
action), "Auto clean" (purify while the air reads bad, stop once it
improves) and "Get notified" (raise a SmartThings notification). Labels were
transcribed from the Korean app and rendered in English; the auto-stop half
of "Auto clean" is the app's own description and is not otherwise visible in
the dump, which reports only the selected autoExeState. The remaining entity
names follow their raw fields rather than inventing a concept -- the skip
window is "sensing skip", after periodicSensingSkipStatus/Time.

Three of this registry's four board families report the resource with the
same field names -- TP1X_DA-AC-AIR (#130), A-VTWW-TP2 (#151) and AVT-WW-TP1
(#84, #190). Only ARTIK051_TVTL (#56) has no such href, and its golden is
unchanged. Bound unconditionally rather than behind a match_fn; the one field
that genuinely varies (periodicSensingInterval, absent on the #130 board) is
gated per-entity, so that board gets eight entities instead of nine rather
than a broken one.

range_hood.AIR_LEVEL_CHECK already models this same href, and its read-only
keys are reused verbatim here so both families share one catalog entry. It is
deliberately not imported: the hood exposes periodic_air_sensing as a
read-only BinarySensorDesc and this board needs a writable SwitchDesc on that
key, so reusing the hood's capability would migrate every hood user's entity
to a different platform.

Every write was exercised on AVT-WW-TP1-23-AXX500 hardware. This board hands
out 2.04 for writes it silently discards (see HEPA_FILTER's filter-reset
note), so an echo proves nothing -- each was judged by whether the value
survived a reconnect, which forces a new DTLS session, fresh discovery and a
fresh observe of the href, leaving no cached state to read back:

  * sensing_mode's combined two-field PUT lands both fields, both ways:
    sensing_only -> auto_purify raises autoExeState with activation still On,
    and back again lowers it.
  * The sensing-skip switch holds Off -> On and back.
  * The half-preserving time writes hold: from 13:00-23:00, writing
    start=07:30 then end=22:00 left the device on '07302200' -- each write
    kept the half it wasn't given.
  * periodic_air_sensing and sensing_interval: writing 60 s drove an observed
    ~60 s sensing cycle.
  * The read side of the skip window is separately cross-confirmed on two
    units: #84's sits at the inert '00000000', #190's carries a real
    '03002300' (03:00-23:00), which is what pins the HHMMHHMM split.
  * The other two families get the writes on field-shape grounds -- the same
    basis on which they already share MODE, HEPA_FILTER and the air-quality
    sensors.

range_hood._timestamp moves to common.epoch_to_utc so both callers share it,
matching how filter_usage_percent was shared. No behaviour change.

Every existing entity is untouched: the three golden updates are purely
additive, no renames, no unit or device_class changes.
2026-08-04 12:57:03 +09:00
Marc Billow fb5ed32b0f Add discrete freezer setpoint support for TP1X_REF_21K (issue #229)
The reporter's fridge/freezer combo reports the issue #186 discrete
definite-setpoint pattern on both compartments, but only the cooler half
was modeled -- /temperature/definite/freezer/vs/0 was unbound. Adds
DEFINITE_TEMPERATURE_FREEZER, identical shape to the existing cooler
capability (same fields, just negative supportedList values).
2026-08-03 19:24:59 +00:00
Marc Billow e6d7dcddc8 Add dryer Drum Clean+ tracking; fix multi-entry DrumCleanLog parsing (#258)
Dryers report the same DrumCleanProposal_/WashingTimes_/DrumCleanLog_
options[] tokens washer.py already models for issue #9, so
drum_clean_cycles_remaining/drum_clean_last_cleaned move to laundry.py and
get bound on dryer's /course/vs/0 too.

DrumCleanLog_ on the reporter's dump is a '|'-joined history of every past
clean rather than washer's single bare timestamp -- the shared helper now
takes the last (most recent) entry, which turns out to also fix a latent
bug on four existing washer fixtures whose own DrumCleanLog_ was already
multi-entry and silently failing to parse into drum_clean_last_cleaned.

No heat-exchanger-clean tracking was found in either dump #258 supplied;
noted in dryer.py so a future report knows this was checked.
2026-08-03 19:14:29 +00:00
Marc Billow cf09247e39 Add AC UV LED, ventilation alarm, and PM1 filter support (issue #270)
TP1X_FAC_TIME_23K reports three previously unbound hrefs: a UV-C
sterilization LED and a ventilation-reminder alarm (both plain On/Off
toggles), and a second PM1-rated dust filter with no live usage/status
fields on this particular dump.

The PM1 filter capability gates each entity on its own field's presence
rather than a blanket ignore, since the TP1X_DA-AC-CAC-01001_0000 cassette
AC (issue #191) reports the same href with full live data -- this also
closes two of that device's ten documented coverage gaps (UV LED and the
PM1 filter) as a side effect.
2026-08-03 19:07:03 +00:00
Marc Billow 3ef64eae52 Add dehumidifier display switch and watertank lighting (issues #271, #231)
The TP1X_DA_AC_DHM_01001_0000 revision (model AY70H18100GTD) additionally
reports /display/vs/0 (same shape as air_purifier's screen toggle, reused
directly) and /watertank/lighting/vs/0 (on/off, color, and brightness for
the tank's ambient light, plus a diagnostic alarm-status flag). Both issues
submitted the identical dump, so one fix covers both reports.

Also adds x.com.st.d.dehumidifier to the /oic/d device-type routing table
now that a dump confirms it.
2026-08-03 18:59:22 +00:00
Marc Billow 42a1812967 Merge pull request #261 from mbillow/claude/pr-242-review-merge-nny8ug
feat: discover UUID-prefixed subdevices advertised only via /oic/res (Pattern C, #241)
2026-08-02 17:42:46 -04:00
Hyunook 6bcf8f3bec feat: discover UUID-prefixed subdevices advertised only via /oic/res (Pattern C, #241)
AWM-WW-AID-26-ONEBODY (washer+dryer combo) reports numofsubdevice='2' on
/multidevice/vs/0 but carries no /subdevices/vs/0 (no subdeviceIdList --
Pattern B's signal) and 4.04s /device/1 and /device/2 (Pattern A's). The
washer subdevice's UUID appears only as the path prefix of the
x.com.samsung.da.multidevice link in /oic/res; GET /<uuid>/device/0
answers the washer's own full Collection batch (model ..._WF80H vs the
master's ..._DV80H27H).

Treat every UUID path prefix seen in /oic/res as a prefixed-subdevice
candidate (minus ones subdeviceIdList already named), probed with the
same tolerated-404 seed RETRIEVE as Pattern B -- the shared body is
factored into _probe_prefixed. discover_partitioned's entity-level
liveness gate still decides materialization, so a UUID link with no live
sibling behind it contributes nothing.

Fixture is a live capture from the reporting board (serials/MACs/di
scrubbed); tests cover discovery, probe hygiene, washer-side entity
binding, and that the master's own entity set is unchanged.
2026-08-02 21:40:34 +00:00
Ian P. Christian 6efee761d9 Add Samsung EHS (Eco Heating System) heat pump support
Adds a device registry for the TP1X_DA_AC_EHS board family: separate
zone1 (space heating/cooling) and dhw (domestic hot water) loops.
zone1 is exposed as power switch + mode select + current/target
temperature sensor/number -- it's a leaving-water-temperature
setpoint, not a thermostat, so no HA platform fits it better. dhw
gets a composite water_heater entity, using the same
primary-resource-plus-sibling-reads shape climate.py already uses
for the AC (PR #247 review feedback: "Having water heaters
automatically leverage the right platform would be pretty cool!").
The unit's away mode is a device-wide switch, not the water_heater
AWAY_MODE feature -- /option/outgoing/vs/0 has no dhw-scoped sibling
and covers zone1 too, so presenting it on the DHW card would
misstate its scope.

Operation modes (Eco/Std/Force/Power) map onto HA's own standard
water_heater states, the same mapping HA core's smartthings
integration uses for this exact Samsung capability over the cloud
API. Device codes are matched case-insensitively on the read side.
The DHW entity takes a catalog name ("Hot water") rather than the
bare device name -- unlike the AC's climate card, it is one loop of
a two-loop device.

Both temperature ranges fall back as a pair: a resource reporting a
minimum but no maximum yields no range at all rather than mixing a
device bound with an invented default, matching climate._range().
Increment fallbacks test for None instead of using `or`, so a
genuine 0 survives.

set_temperature honours the optional operation_mode HA's
water_heater service schema forwards, setting the mode (and powering
the loop on) before the setpoint, the same way climate's
set_temperature handles hvac_mode.

Entity names are translated into Czech and Dutch following each
file's existing terminology conventions.

Verified against a real TP1X_DA_AC_EHS_01001_0000 diagnostics dump
(firmware AEH-WW-TP1-22-AE6000_17260402); golden-regression fixture
and full test coverage included.
2026-08-02 22:18:43 +01:00
Marc Billow e309d3e7b8 Merge pull request #225 from atc722/agent/qooker-support
Route Samsung Bespoke Qooker to microwave registry
2026-08-02 12:22:10 -05:00
Geunwon Mo 5c275753d4 Report whether the auto-clean cycle is running, and how far through
`/option/autoclean/vs/0` carries three fields and only `settingStatus` was read.
That one says the feature is enabled, which it is whether or not the unit is
drying right now, so nothing reported an actual cycle.

    settingStatus: On      <- the existing auto_clean switch
    status:        Stop    supportedStatus: [Start, Stop]
    progress:      0

Adds a binary sensor for `status` and a percentage sensor for `progress`.

Measured on a TP1X_DA-AC-CAC-01001, sampling the resource every eight seconds
across a cycle: `Start` with progress 98 while it ran, then `Stop` with progress 0
the moment it finished. The percentage matches the figure the appliance shows on
its own display, checked against 55% mid-run.

Golden state keys updated for the 18 fixtures that bind AUTO_CLEAN. The change is
additive — no key was removed from any of them.

Full suite passes (1070 tests, Python 3.13 via requirements-dev.txt).
2026-08-02 22:01:27 +09:00
hoon f9cd857ced Support Samsung Bespoke Qooker routing 2026-08-01 10:47:00 +09:00
Marc Billow 3c6c7f246f Merge branch 'main' into ac-filter-reset 2026-07-31 20:13:40 -05:00
Marc Billow 6166f63570 Merge pull request #224 from mbillow/claude/issue-triage-batch-h4n2wq
Issue triage batch: #207, #189, #208, #181/#183, #196, #210 + contributing docs
2026-07-31 15:22:55 -05:00
Marc Billow b7d3f86ec7 fix: address code review feedback on issue-triage batch PR (#181, #183, #189, #196, #207, #208, #210)
common:
- Make KIDS_LOCK_GENERIC also a read-only BinarySensorDesc (device_class='lock'),
  flipping value_fn to not bool(v) so /kidslock/0 value=False and
  /kidslock/vs/0 kidsLock='Ready' render with the same polarity ('On'
  means open/unlocked per HA's lock device class). The old SwitchDesc
  form never honored device_class='lock' -- HA's switch platform only
  accepts 'outlet'/'switch' -- so the surface was a plain switch whose
  'On' meaning drifted across boards. Tests updated.

air_monitor:
- Add state_class='measurement' to dust/fine_dust/super_fine_dust so
  the readings feed HA long-term statistics (co2 already had it).
- Import _AIR_QUALITY_SENSORS from air_purifier instead of duplicating
  it byte-for-byte; update common.sensor_item_value's docstring to
  mention the third caller.

by_type/__init__: drop trailing whitespace on the new 'ASM' line.

translations/en.json + nl.json: move the new 'dnd' switch entry to its
correct alphabetical position (after display_light, before fast_preheat).

SKILL.md: add an explicit read-side rule to §5's educated-guesses
section -- guessed unit/device_class/state_class on a SensorDesc
silently mislabels readings forever with no 4.xx to catch it (unlike
guessed writes, which the device rejects). The prior air_monitor
docstring cited this carve-out as if it existed; now it does.

tests/water_purifier (issue #196): change the ailite fixture's
favorite.defaultTemperature from '85' to '50' so the test actually
reproduces the reported bug -- '50' is in showList only, so a
descriptor reading from supportedList would fail the assertion that
the current default is in its options list.
2026-07-31 15:17:18 -05:00
Petr Divis f15ee7e563 Update golden fixtures for the new odor-controller entities
CI caught it: 8 pre-existing AC fixtures also carry genuine SmartCoolClean_/
ProgressSmartClean_ tokens in /mode/vs/0 (lnx_rac_heatpump, ara_ww_tp1_22,
windfree_oscillation, tp1x_rac_01001, fac_bora, fac_bora_2in1,
fac_bora_205_flat, cac), so odor_controller_active/odor_controller_progress
now correctly bind there too -- their golden state_keys lists just hadn't
been regenerated. Verified against the actual downloaded CI job log.
2026-07-31 16:39:08 +02:00
Petr Divis d0c68fb5ac AC: bind SmartCoolClean odor-controller option tokens; add Czech translation
- airconditioner.py: odor_controller_active binary_sensor + odor_controller_progress
  sensor, read from the /mode/vs/0 SmartCoolClean_/ProgressSmartClean_ option tokens
  (SmartThings cloud custom.airConditionerOdorController capability). Read-only --
  no confirmed write command.
- Reporter's TP1X_DA-AC-RAC-01001_0000 dump: fan speed and WindFree preset already
  bind via the existing composite climate entity, no code change needed there.
- en.json/nl.json: new entity names for the two additions.
- cs.json: new, full Czech translation catalog (mirrors en.json topology 1:1).
- New fixture + golden + tests locking in the odor-controller behavior.
2026-07-31 16:02:13 +02:00
perseus177 9ee0dbb8f9 feat(airconditioner): filter alarm interval on legacy ARTIK051 boards
Adds the Select the official app offers next to the filter reminder --
180/300/500/700 hours -- which this board generation keeps as a FilterAlarmTime_
token in /mode/vs/0's options[] rather than on a /filter/* resource.

Confirmed on hardware: stepping through all four radio positions in the app
moved that one token and nothing else across all 19 resources, so the token
carries the hour count verbatim; and a local write of 500 to a unit sitting on
700 was accepted and kept, surviving a restart. The cloud exposes none of this,
so it is only available locally. Gated with the counter it belongs to, so
boards carrying a real /filter/airdustfilter/vs/0 threshold keep using that one
-- the gate is covered by a test that injects the token into a newer board's
dump, since no non-legacy fixture carries it and the assertion would otherwise
pass for the wrong reason.

Also settles what filter_time measures: it counts UP -- running time
accumulated since the last filter reset, not time remaining -- which an earlier
revision of that comment explicitly left open. Three independent things agree:
the token rising while the unit runs, FilterAlarmTime_ being the threshold it
is measured against, and /alarms/vs/0's filter entry tracking the counter
across two units on one site (a live unsuffixed 'FilterAlarm'/'Created' at
FilterTime_5595 against the 'FilterAlarm_OFF'/'Deleted' placeholder at 1915).
The alarm clearing by itself the moment the counter dropped under the threshold
is the causal half of that, not just correlation.

Resetting the counter is NOT solved and no reset entity is added. The
descriptor records what was tried, and what the failures do and do not prove,
so the next attempt starts from evidence instead of from scratch. Short
version: the reset is a *command* (custom.dustFilter/resetDustFilter), not a
value write, which is why nothing that writes the counter works; I could not
work out how to drive that command locally. /actions/vs/0 is the obvious local
command channel but publishes no schema, and I did not enumerate guessed action
names against a live appliance.

Written with Claude (AI), on the author's own hardware; every result quoted
above is measured on the device rather than inferred.
2026-07-31 12:41:40 +02:00
Marc Billow a7d57086e9 feat: add Samsung Air Monitor Plus support (#210)
New device family: a standalone, battery-powered air-quality sensor
puck (ASM-KR-TP1-22-* board) with no controllable-appliance state at
all -- no /power/*, only /energy/battery/vs/0. Routes via both /oic/d
('x.com.st.d.airqualitysensor', confirmed against the real dump) and
the 'ASM' modelNum board token as a fallback.

/sensors/vs/0 reuses air_purifier.AIR_QUALITY's existing {type, value}
items-list decode (common.sensor_item_value) for dust/fine_dust/
super_fine_dust/odor/clean_level, sharing those capabilities' catalog
entries, and adds a CO2 reading those families don't report. The
particulate sensors deliberately get no pm10/pm25/pm1 device_class:
the values read as physically consistent (coarser >= finer) but
Samsung's own two-tier dust naming doesn't confirm where this board's
three-tier split actually maps, and mislabeling a read-side unit is a
standing, not one-shot, kind of wrong -- exposed as plain named
sensors instead. Humidity, battery/charging, and the informational air
quality standard are otherwise straightforward field reads.

/dnd/vs/0 (do-not-disturb window) is a flagged educated guess: the
write contract mirrors the read side's own string/time-format shape
(the safest kind of guess) but has no idle-vs-active dump to confirm
it end-to-end, so it's called out as such in code and will need a
reporter to verify on real hardware. /keepnormalstate/vs/0 and
/sensordatasinks/vs/0 are genuinely opaque (single unexplained value,
no supported-values list) and are ignored rather than guessed at.

Locked in with a scrubbed fixture, golden, and capability tests.
2026-07-31 02:40:02 +00:00
Marc Billow 5bbc7aeece fix(air_dresser): bind /buzzersound/vs/0 on the TP1_21 board (#208)
DA_DF_TP1_21_COMMON reports a plain {setBuzzerSound, supportedFinishSound}
buzzersound resource -- the same shape laundry.BUZZER_SOUND already
handles for washers/dryers -- but it was unbound because the air_dresser
registry never included that capability. Add it, and lock the board in
with a scrubbed fixture, golden, and capability tests.

The reporter's actual complaint (course cycles showing as raw codes) is
a labelling gap, not a coverage one: this board's course table has no
code->name mapping anywhere in the dump, same as issue #162's board, so
there's nothing to bind here -- it needs a reporter to identify the
codes before they can be named in translations.
2026-07-31 02:03:32 +00:00
Marc Billow 5e86f147d4 fix(subdevices): don't materialize a slot whose only live state is a meter
Issue #214: a single-split ARTIK051_KRAC_18K showed up in HA as two air
conditioners. Its /device/1 answers the same unused-slot shape the Pattern A
reporter's /device/2 does -- every operational rep empty {} -- but also
reports a populated /energy/consumption/vs/1. Running discovery against the
reporter's own quoted subdevice block reproduces their diagnostics exactly
(21 bound entities, the same six hrefs), and of those 21 the only primary
entity with a non-None value is energy_kwh: a lifetime kWh total was the
sole thing passing discover_partitioned's liveness gate and materializing
the phantom.

A single-split AC has one compressor and one energy meter, so a
whole-appliance running total appearing under a second index is the
appliance's own bookkeeping, not evidence that hardware is installed at that
slot. Exclude cumulative meters (HA's total/total_increasing state classes,
plus the energy/water/gas device classes for the descriptors that
deliberately declare no state class) from the gate. The gate never applies
to MAIN, and across the whole fixture corpus every device has at least one
non-meter live primary, so no existing device's entities change -- verified
by the golden for the new fixture being identical to the plain KRAC one.

Also implement async_remove_config_entry_device. A subdevice's HA device
outlives the discovery that created it, so a phantom materialized by an
earlier release stays in the registry with no way to delete it from the UI
-- which is the state the second reporter on that issue is in, with a
refrigerator whose diagnostics now report no subdevices at all. Devices the
entry currently provides still refuse removal. No automatic pruning:
enumeration is one-shot and a real sibling can miss a poll (issue #205 on
the reference hardware), so auto-removal would discard a live subdevice's
name, area and automations on a transient miss.

The new fixture's /device/1 seed is the reporter's verbatim capture; its
master half comes from the corpus's other KRAC unit, with the deviations
spelled out in seeds_note.

Claude-Session: https://claude.ai/code/session_01HzUMLnSWBT64o4BQkVEzXp
2026-07-30 18:23:47 +00:00
Marc Billow ca27bf7f6e docs: de-identify reporter usernames repo-wide, add PII rule to skill
Extended the earlier de-identification (jhkwon19) to the other issue #177
reporter (HJcom), who was named in ~20 spots across coordinator.py,
diagnostics.py, subdevices.py, identity.py, capabilities/airconditioner.py,
a fixture's seeds_note, and several test docstrings/function names. Swapped
all of it for "the reporter"/"the Pattern A reporter", matching the
convention already established for the other reporter.

Added a rule to the adding-device-support skill (end of "Lock it in"):
don't put a reporter's name or GitHub username in code comments,
docstrings, seeds_note, or test/function names -- that prose ships and
sits in git history indefinitely, unlike an issue thread or a
release-notes thank-you. Use "the reporter" / "issue #NNN's reporter" /
a pattern label instead.
2026-07-30 03:06:06 +00:00
Marc Billow ce92d71a92 docs: de-identify the reporter's username in code comments
Comments/docstrings across subdevices.py, coordinator.py, the two fac_bora
fixtures, and their tests named the issue #177/#205 reporter directly.
Swapped to "the reporter"/"the Pattern B reporter" throughout -- no
behavior or test-assertion changes, string content only. HJcom (the
Pattern A reporter) is unaffected.
2026-07-30 02:50:49 +00:00
Marc Billow 8600985a36 review: address Opus findings on the subdevice flat-href fallback
- coordinator: _poll_subdevice_flat_hrefs called sess.pace() outside its
  try block and re-read self._session instead of using the caller's
  already-None-checked reference -- a session closed mid-poll (async_close()
  doesn't hold _session_lock) could crash the whole poll cycle instead of
  just dropping that one sibling. Now takes sess from the caller and guards
  pace() the same as get().
- coordinator: skip flat hrefs already covered by the hot/warm sub-poll
  tiers -- those are refreshed every few seconds by _run_subpolls already,
  so re-fetching them again on the once-per-summary-poll flat pass only adds
  GETs, not freshness. Matters because, unlike the Collection path (always
  one GET), a flat subdevice's summary-poll cost scales with its href count.
- subdevices.py module docstring: corrected an overclaim inherited from PR
  #199 that GET /<uuid>/device/0 had been "confirmed live" on jhkwon19's
  unit. Only an individual /information/vs/0 read was ever actually
  confirmed; the Collection endpoint itself has never been observed to
  answer on any known unit, which is exactly what issue #205 exposes.
- SKILL.md: fixed the numofsubdevice cross-check formula to match what
  coordinator.py actually compares (len(materialized) + 1, not
  len(subdevices) + len(subdevices_skipped)).
- Documented, not yet guarded against: a firmware that echoes state back
  under any unrecognized prefix instead of 4.04ing could pass the flat probe
  and the liveness gate, materializing a phantom duplicate of the master.
  Every board seen so far genuinely 4.04s on paths it doesn't own.
- Added test coverage the review flagged as missing: a materialized (not
  just skipped) flat subdevice re-polling end-to-end through to
  canonical_resources, the hot/warm skip itself, zero-master-hrefs and
  two-UUID no-cross-contamination edge cases, and a golden file for the
  #205 fixture (SKILL.md's "fixture + golden + test" discipline).
2026-07-30 02:44:26 +00:00
Marc Billow e78d941af3 fix(subdevices): fall back to per-href probing when a prefixed subdevice has no /device/0 Collection
Issue #205 shows the UUID-prefixed pattern's own reference device
(TP2X_FAC_BORA_21K) doesn't always answer /<uuid>/device/0, contrary to
what the pattern was built against. When that Collection GET comes back
empty, enumerate_subdevices now probes every href the master itself
answered this cycle individually under the UUID prefix, keeping whichever
ones respond. Subdevice gains a flat_hrefs field for this, and the
coordinator re-polls those hrefs individually each cycle instead of
re-fetching a Collection batch that doesn't exist.

Built a fixture from the reporter's real #205 diagnostics dump: the
fallback finds a candidate through the one href already confirmed live
under this UUID (/information/vs/0, from the #177 thread), and
discover_partitioned's liveness gate correctly holds it back since that
href alone binds no entity -- honest current state, not a guessed
resolution.
2026-07-30 02:25:26 +00:00
Marc Billow fb2d267632 fix(water_purifier): route AILITE_DA-REF-WATERPURIFIER boards correctly (#196)
The AILITE water-purifier board (RWP70F15ANW) spells its modelNum
'...-REF-WATERPURIFIER-...', so the board-token scan hit the bare 'REF'
token before ever reaching 'WATERPURIFIER' and misrouted the device to
the refrigerator registry, whose resource surface shares almost nothing
with a water purifier -- hence the incomplete-coverage warning. Add a
documented carve-out for this one token co-occurrence and a matching
TestBoardTokenAmbiguity exception.

Also bind the water-purifier hrefs this board additionally exposes:
cup-detection status, the settings/sound/{mode,output,volume} trio (read
live, since this board's own supportedModes vocabulary differs from both
laundry's and air_purifier's hardcoded/live sets), and last-pour
statistics.

Separately, gate hot_water_temperature off when the device doesn't report
a supportedHotTemperatures list (only a hotwaterRange/hotwaterLevel pair
with no confirmed write contract) -- previously an empty options list
plus a live current value rendered as 'unknown' in HA, the second bug
reported in #196. The existing water_purifier_coffee fixture (#107) turns
out to hit the same shape, so its golden drops the entity too.

Issue #195 (TP1X_REF_21K) needed no change: its diagnostics show zero
unbound hrefs and the model already routes to the refrigerator registry,
matching the maintainer's own comment on the issue.
2026-07-29 23:23:56 +00:00
Marc Billow 9e85395b44 rename: unit/sub-unit -> subdevice, matching OCF terminology
"Unit"/"sub-unit" from #199's multi-indoor-device support wasn't OCF
idiomatic -- OCF calls each component of a composite device a
"subdevice" (see subdeviceIdList), so rename SubUnit -> Subdevice
throughout: the registry module, coordinator state, BoundEntity's
subdevice field, diagnostics keys (subdevices/subdevices_skipped/
subdevice_probes), entity unique_id prefixes (unit1_/sub_<uuid>_ ->
subdevice1_/subdevice_<uuid>_), device-name fallback labels, golden
fixtures, tests, README, and the adding-device-support skill.

Breaking change to entity unique_ids and diagnostics keys, acceptable
since this hasn't been released yet.
2026-07-29 22:57:11 +00:00
Marc Billow 9442248c20 Merge origin/main into multi-device sub-unit support
Conflict was purely additive: both sides appended golden-regression
tests at the same point in the file, and each side's last test shared
the single trailing assert block. Kept every test from both sides, each
with its own copy of that assert.

One real semantic merge on top of that. #136 (on main) remodelled the
legacy ARTIK051 board's beep from a buzzer_volume Number to a beep
Switch, and HJcom's ARTIK051_DONGLE_FAC_18K is exactly that board
generation (is_legacy_board -> True), so its golden -- written before
that change existed -- still expected buzzer_volume. Regenerated it:
buzzer_volume/unit1_buzzer_volume -> beep/unit1_beep on the master and
the second indoor unit alike, with nothing else moving and still no
unit2_ keys. That is main's intended behavior reaching the sub-unit for
free, which is the point of binding siblings through the same registry.

967 passing. Re-ran the corpus-wide unique_id audit over all 57
fixtures (main added five this branch had never seen): no collisions
within a platform.
2026-07-29 19:40:32 +00:00
Marc Billow c181a8b447 feat(subdevices): support multi-indoor-unit systems (#177)
Samsung 2-in-1 air conditioners put more than one logical indoor unit
behind a single IP and a single DTLS session. Only the unit the config
entry was set up against was ever discovered; the second one -- a whole
physical appliance the user can see in SmartThings -- had no entities at
all. Two reporters turned out to have two different mechanisms:

  ARTIK051_DONGLE_FAC_18K -- indexed siblings. /oic/res registers the
  whole tree discoverable and lists three complete parallel resource
  sets whose trailing path segment is the index (/mode/vs/0, /mode/vs/1,
  ...), on OCF-standard and vendor hrefs alike. /device/0's batch
  carries only the index-0 hrefs, so a sibling is reachable only through
  its own /device/<n> collection.

  TP2X_FAC_BORA_21K -- UUID-prefixed tree. /oic/res hides the appliance
  tree entirely (which is why a direct /device/1 probe returns nothing
  on this board). /subdevices/vs/0 carries subdeviceIdList instead, and
  that UUID appears as a literal href prefix; /<uuid>/information/vs/0
  was confirmed live to return the wall unit's own model and serial
  (TP2X_FAC_BORA_RAC_21K) against the master's TP2X_FAC_BORA_21K.

The detection signals don't overlap on either board, so no
disambiguation is needed -- enumeration checks both and takes what
answers.

Both patterns are the same thing underneath: a logical unit is a seed
collection path to poll plus an href transform between the canonical
href the registry knows and the actual on-the-wire href. That is the
whole abstraction (SubUnit), applied at four boundaries -- discovery,
the coordinator, the adapter, and the platforms. Capabilities, the
registry and the climate composite stay written against canonical hrefs
and are untouched.

Uniqueness comes from a key_prefix inside the flattened state key, so
the master unit's keys are byte-identical to every release before this
and every existing golden file is an unchanged regression guard. Each
sub-unit gets its own device-registry entry linked by via_device and
named from its own /information/vs/<n>, so it lands in its own room
rather than crowding the master's device page.

A sub-unit materializes only when it yields at least one primary
(non-diagnostic) entity with a populated value. That gate is not
decoration: the reporter's /device/2 is an unused slot that SmartThings
shows disabled, yet it answers with a full 14-href batch, and it
flattens to exactly one non-None value -- a diagnostic alarm_code
derived from an empty /alarms/vs/2. Without the entity-category filter
it becomes a phantom third climate card. The rule is deliberately
domain-agnostic rather than a list of HVAC hrefs, so a multi-drum
washer (#19) gets the same treatment with no new curation. Units that
answer but fail the gate are logged and reported in diagnostics, so a
genuinely missing unit stays diagnosable from a dump.

Enumeration fetches things that must not then be treated as appliance
state. A rejected candidate's seed has to be read to evaluate the gate,
but only units that pass are polled again, and StateCache has no
eviction -- so discovery runs before the first cache apply and those
reps are held aside for diagnostics rather than frozen into the cache
forever. /multidevice/vs/0 is probed on every device regardless of
family, so merging it into the resources dict would have reached
discovery on any board whose registry doesn't ignore that href -- only
the air conditioner one does -- raising a spurious coverage-gap repair
for a washer or fridge whose firmware answers it. It is corroborating
metadata (numofsubdevice, confirmed read-only) and now lives beside the
resources rather than in them.

Diagnostics reports each unit separately: top-level `resources` is this
unit's own and only its own, which is what the module docstring and the
adding-device-support skill have always claimed it was, and each
sibling or rejected candidate carries its own reps canonicalized so a
block reads exactly like the master's instead of needing to be
de-indexed by hand.

Fixtures are real captures. The ARTIK051_DONGLE_FAC_18K one is entirely
verbatim, both sibling seeds and the hand-read /multidevice/vs/0
included. The TP2X_FAC_BORA one has a real device0, oic_res and
sub-unit /information/vs/0, with the remainder of that unit's tree
constructed and documented as such in seeds_note; /<uuid>/device/0 is
the one part of that pattern still inferred rather than observed, and
can't be tested through the debug panel because a Collection returns a
list.
2026-07-29 19:14:51 +00:00
Marc Billow bd3ca80d3c review: address Opus code-review findings on this branch
- config_flow: the #192 port-rescue made the "every port refused" fast-fail
  permanently unreachable (PREFERRED_PROBE_PORTS is always non-empty and
  always rescued), so removed the dead branch instead of leaving it as
  misleading dead code. A dead host now fails via the handshake loop's own
  error, which carries the real per-port reason.
- oven._has_option: added the is_stub_rep carve-out cooktop.py's identical
  per-token exists_fn already has on the same kind of href, so a not-yet
  sub-polled /mode/vs/0 doesn't permanently exclude energy_saving/
  cooktop_on_alert before their first real fetch lands.
- airconditioner.ENERGY_METER_LEGACY: build via dataclasses.replace() like
  its ENERGY_METER_GENERIC sibling, instead of hand-copying href/poll_tier
  (which would silently drift if common.ENERGY_METER ever gains a field).
- Fixed two stale comments: is_legacy_board()'s docstring still listed
  Volume among tokens needing legacy-only gating, though 'beep' now applies
  unconditionally across board generations; and common.py's UNIVERSAL
  invariant comment didn't mention that airconditioner also now excludes
  ENERGY_METER from the wholesale bundle.
- #191 (CAC token): added the fixture/golden/capability-test coverage the
  AVT token in the same branch got, including an honestly-documented list
  of the ten hrefs this board generation doesn't cover yet.
- fridge.cooler_temperature_setpoint: dropped the hardcoded "N °C" state
  labels -- the resource's own unit field isn't necessarily Celsius on a
  different model reporting the same href, and the options themselves are
  already read live via options_field, so a static per-value label risked
  asserting the wrong unit for a future device sharing this capability.
- airconditioner._legacy_cumulative_power_kwh: parse with float (matching
  common.wh_to_kwh's own numeric parsing) instead of this module's
  integer-only _int, so a decimal-formatted reading doesn't raise.
- test_config_flow: the port-rescue test bound the real 49154 directly,
  which could collide with an actually-running service on some machine;
  now monkeypatches PREFERRED_PROBE_PORTS to an OS-assigned port instead.
- oven.py: consolidated six byte-for-byte-identical single-token options
  write_fns (lamp/sound/fast_preheat/natural_steam/energy_saving/
  cooktop_on_alert) into one _option_switch_write(prefix) factory.

845 tests passing (up from 841 -- 4 new CAC coverage tests).
2026-07-29 18:04:23 +00:00
Marc Billow 36240b44e6 fix(oven): gate fast_preheat/natural_steam on their own tokens (#183)
Both switches were shipped unconditionally (no exists_fn) as an unverified
guess -- the module docstring already flagged them as "unproven." Every
range/oven fixture in the corpus, including the new issue #183 dump,
reports neither fastpreheat_* nor NaturalSteam_* in /mode/vs/0's options at
all, so both were phantom controls: always read as off, and toggling them
wrote a token the firmware never recognized in the first place. That
matches the reporter's exact complaint ("doesn't appear to do anything").

Also bound two tokens confirmed present on this dump but never modeled at
all: EnergySaving_On (the 120-hour energy-saving standby from the app) and
BurnerOnAlert_Off (cooktop-on alert), following the same single-token
options-merge pattern as the existing lamp/sound/fast_preheat switches.

Child lock, the setpoint mismatch, and the missing cook-start control from
this issue are not code bugs -- see the issue comment for what was verified
and what still needs more information from the reporter.
2026-07-29 13:26:39 +00:00
Marc Billow 487ac748bd fix(airconditioner): model legacy-board beep as a switch, not a volume (#136)
Every ARTIK051_KRAC_18K-generation unit confirmed on hardware (three units
across two reporters) only ever carries Volume_100 or Volume_Mute in
/mode/vs/0's options -- never an intermediate value -- so the existing
buzzer_volume Number (0-100, step 10) modeled a control this firmware
doesn't have. Worse, its write path could never produce the literal
'Mute' token needed to actually turn the beep off, since it only ever
wrote a plain integer string. The 'beep' switch already used on newer
boards is the correct model here too; it's no longer gated off the legacy
board generation, and the Number entity is removed.

The WindFree-preset-not-applying report earlier in this issue self-resolved
per the reporter's own follow-up testing, so no code change was needed for
that part.
2026-07-29 13:16:09 +00:00
Marc Billow b5c5c056f4 feat(fridge): expose discrete cooler temperature setpoint (#186)
RT42DG6630B1FZ is a single-door "cooler only" fridge that reports its
setpoint on /temperature/definite/cooler/vs/0 -- a vendor resource outside
both TEMP_CURRENT_GENERIC's '/temperature/current/' and TEMP_SETPOINT's
'/temperature/desired/' href prefixes, so it was entirely unbound and the
setting stayed app-only. Its supportedList (1/2/3/4/7 °C) isn't a
contiguous range, so this is modeled as a select over the device's own
live options rather than a NumberDesc that would let a user pick an
unsupported value like 5 or 6.
2026-07-29 13:11:07 +00:00
Marc Billow 74f34b91a5 feat(registry): route AVT-WW-TP1-23 air purifier boards (#190)
AVT-WW-TP1-23-AXX500 (AX053B810HGD) reported device_type 'unknown' with
empty oneUiVersion, falling back to common caps. It's the same BESPOKE
Cube Air lineage as A-VTWW-TP2-21-COMMON (issue #151), just with the
'-WW-' delimiter shifted one letter left ('A-VTWW-' -> 'AVT-WW-'), which
splits into an 'AVT'/'WW' token pair the existing whole-token 'VTWW' entry
can't see. Added 'AVT' as its own board token onto the same air_purifier
registry -- the resource surface (wind/strength fan, HEPA filter, air
quality sensors, alarms) already matched with zero unbound hrefs once
routed there, so no new capabilities were needed.
2026-07-29 13:06:36 +00:00
Marc Billow d83733a670 fix(airconditioner): scale legacy ARTIK051 cumulativePower correctly (#193)
ARTIK051_KRAC_18K-generation boards report /energy/consumption/vs/0's
cumulativePower in centiwatt-hours, not the plain Wh every other AC board
family reports -- confirmed against the reporter's own SmartThings-app
reading (raw 117430000 vs. the app's authoritative 1,174.30 kWh is exactly
a /100000 factor, not the shared wh_to_kwh's /1000 alone). Split
common.ENERGY_METER into generic/legacy variants on the airconditioner
registry, discriminated by the existing is_legacy_board() check, so every
other AC family keeps the unmodified shared capability.
2026-07-29 13:04:33 +00:00
Marc Billow a6eb1c62d4 feat(microwave): add filter reminder / end signal reminder switches (#181)
Both FilterRemind_*/RemindBeep_* option-array tokens are already
present -- and both On and Off already confirmed -- on the existing
ME7500D fixtures (issue #152), so this is a straight sibling of the
Sound/Lamp switches rather than new discovery work. Gated with
exists_fn like Lamp since the MW7300B combi dump has neither token.

Doesn't address the rest of issue #181 (power-level slider,
non-reported cooking modes, 3-level light, child lock, send-to-
microwave) -- those need write-contract confirmation this dump
doesn't carry.
2026-07-29 02:55:47 +00:00
Marc Billow 2b24152276 feat(registry): cover absence-power-saving and motion-detect-wind on AC (#173)
Lennox-branded heat pump on the Samsung RAC board family (modelNum
TP1X_LNX-AC-RAC-01001_0000) already routes correctly via the existing
'-RAC-' token, but its dump has two resources no prior AC fixture
carried: /mds/absencepowersaving/vs/0 and
/option/motiondetectwind/stateful/vs/0. Bind both as read-only
sensors, matching the CURRENT_LIMIT/ANOMALY_LOAD precedent -- nothing
in the dump confirms write safety on live HVAC hardware.
2026-07-29 02:52:33 +00:00
Marc Billow bbf3f3f833 Revert unsound air-quality gating from #170, cover remaining fan-speed icons
An Opus review of merged PR #170 found the cleanLevel-scalar existence
gate on AIR_QUALITY doesn't hold up as a general rule: three fixtures
in this repo (air_purifier_device.json, air_purifier_vtww_device.json,
range_hood_device.json) carry genuinely populated Dust/FineDust/
SuperFineDust readings with no such scalar, so requiring it risks
silently dropping real air-quality readings on AC hardware this repo
hasn't seen yet. Reverted _has_sensor_type to item-type presence only
(as before #170) and moved the #166 fix to enabled_default=False on
all five entities instead -- same conservative, non-existence-gated
treatment already used for tropical_night_mode and the fridge/cooktop
precedents it was modeled on. Golden fixtures and tests updated to
match; the five sensors are bound-but-disabled on windfree/#17-style
boards again rather than unbound.

Also added icons for the AC fan_mode values #170 missed -- the raw
numeric labels ("1".."5") that TP1X_DA-AC-RAC-01001 and the window-AC
board report instead of turbo/max -- and swapped the whole fan-speed
icon family to mdi:fan-speed-1/2/3 for a more purpose-built look than
the generic speedometer, applied consistently to both the AC climate
card and the air purifier fan. Fixed motiondirect/motionindirect to
match core's smartthings integration's arrow pairing (previously
inverted).

Known limitation, not fixed here: enabled_default only affects newly
registered entities. Anyone who already has tropical_night_mode or the
five air-quality sensors enabled from #164 (a narrow window before
this fix, but real) won't see them auto-disable -- they'd need to
disable them by hand in Settings > Devices > Entities. A real fix
needs a one-time entity-registry migration, which this integration has
no existing infrastructure or test coverage for; scoping that felt
like its own follow-up rather than something to bolt on here.
2026-07-28 19:07:59 +00:00
Marc Billow 739881de16 Gate AC tropical night mode and air-quality sensors on real capability signals (#166)
Issue #166 (ARxxTXFCAWKNEU, board ARTIK051_PRAC_20K) reported tropical
night mode, clean level, dust, fine dust, odor, and super fine dust
entities showing up even though the reporter's units have no such
physical features. All six were added in #164.

The Sleep_<N> options token backing tropical_night_mode is present in
every AC dump on record regardless of confirmed reality, so there's no
usable signal at boot time -- it's now registered but disabled by
default (matching the precedent already set by fridge.rack_count /
cooktop.paired_hood_model), letting units that do have it opt in.

/sensors/vs/0's item-type list has the same problem (all five types
always listed, permanently zero on this board), but there turned out
to be a real tell: a top-level x.com.samsung.da.cleanLevel scalar is
present only alongside genuinely populated readings on every dump on
record (tp1x_da_ac_rac_01011, the tp1x_da_ac_air air purifier fixture)
and absent on every all-zero ARTIK051_PRAC_20K dump, including both
#166 units and the original windfree/#17 fixtures this capability was
first verified against -- which, per their /information/vs/0, turn out
to be the same board revision as #166's units, so that "verification"
never actually proved a real sensor either. AIR_QUALITY's exists_fn now
requires that scalar, and the windfree/airconditioner golden fixtures
are updated to match (those five entities no longer bind there).
2026-07-28 18:12:02 +00:00
Marc Billow 65b0326d62 Merge remote-tracking branch 'origin/main' into claude/issue-triage-138-latest-y90g78
# Conflicts:
#	tests/test_airconditioner_capabilities.py
2026-07-28 14:51:29 +00:00
Marc Billow 5a73a25005 Address independent code review findings on PR #167
Two real bugs, both latent (no shipped fixture exercised them), plus a
consistency gap and a couple of correctness/DRY nits flagged by review:

- async_set_fan_mode resolved a fan_mode label against the static
  _FAN_TO_DEVICE reverse map before checking whether the resulting code is
  actually one of the unit's own supportedModes. A board using non-standard
  wind-strength codes while still spelling a standard-looking label in
  modesName (e.g. codes "31"-"33" named "Low"/"High"/"Turbo") would silently
  write a code ("1"/"3"/"4") the device never advertised. Now validates the
  static hit against the unit's own supported codes before trusting it,
  falling through to the live modesName scan otherwise.

- air_purifier.WIND_STRENGTH_FAN reused key='fan', the same key as FAN in
  the same registry -- BoundEntity's unique_id is built from key alone, not
  href, so a board reporting both hrefs would have one fan entity silently
  shadow the other. Renamed to 'wind_strength_fan' (translation_key
  unchanged). No shipped fixture reports both hrefs today, but the two caps
  living in the same registry made this a real latent hazard, the exact one
  AIRFLOW_GENERIC's own comment already documents and deliberately avoids.

- microwave.py's cooking_mode select still used a static, union-of-all-
  dumps mode list, even though both shipped microwave fixtures already
  report x.com.samsung.da.supportedModes on /mode/vs/0 -- the same shape
  oven._oven_mode_options was just built to prefer over exactly this kind
  of static list (issue #138's follow-up, this same PR's skill update).
  ME7500D advertises 4 modes; the select was offering 11. Applied the same
  live-first, static-fallback pattern.

- Added the issue #152 fixture the microwave lamp fix was missing (the
  SKILL.md step this PR itself added asks for one).

- climate.py's _legacy_airflow rebuilt a 2-key presence dict from
  coordinator.resource()'s truthiness, which collapses "href absent" and
  "href present with an empty {} rep" to the same falsy value -- while
  is_legacy_board (and discover()'s own binding) test key membership, not
  truthiness. Simplified to pass last_resources through directly, matching
  is_legacy_board's actual contract instead of a cheaper approximation of
  it, so the "can never disagree" claim in both docstrings is actually true.

- Hoisted the 'power' payload branch duplicated verbatim across
  _airflow_fan_write/_fan_write/_wind_strength_fan_write into one
  _power_write helper (registry/capabilities/air_purifier.py).

- Removed two now-unused imports (test_air_dresser_capabilities.py,
  test_air_purifier_vtww_fan.py) and replaced a tautological
  code-in-_DEVICE_TO_FAN check with one that actually exercises the live
  climate entity's fan_modes/fan_mode (test_climate_ac_modes.py).

- Fixed a pre-existing (not from this PR) no-op test on main --
  test_registry_reproduces_golden_state_keys_for_induction_cooktop computed
  golden/state_keys and never asserted on them.

756 tests pass.
2026-07-28 14:37:32 +00:00
Marc Billow dc3e1255d1 Ignore fridge /rm/control/vs/0 plumbing href (#165)
TP1X_REF_21K's EU region variant reports a bare resource-monitoring
poll-interval config (minPeriod in ms) the US variant doesn't -- the only
unbound href keeping the coverage-gap repair open. Door sensors, the
reporter's actual ask, were already covered generically by
fridge.DOOR_GENERIC/DOORS_FALLACK.
2026-07-28 14:27:15 +00:00
Marc Billow daa7546208 Add device support for Wind-Free 2-in-1 AC TP2X_FAC_BORA_21K (#150, #153)
This board (a floor-standing + wall-mounted indoor unit pair sharing one
outdoor unit and one local IP) reports no oneUiVersion and carries the
'_FAC_' modelNum token, which no existing routing rule matched -- it fell
back to 'unknown' and exposed nothing but a power switch, with no climate
entity generated at all (both issues' reported symptom).

Once routed to the existing airconditioner registry, it binds cleanly
against the exact same CLIMATE composite every other room-AC family uses --
same Cool/Dry/Wind/AIComfort mode vocabulary, same wind-strength/humidity/
filter/energy resource shapes already modeled. Only two hrefs are unique to
this board: /subdevices/vs/0 (an opaque paired-subdevice id list -- issue
#150 asked whether the second indoor unit can be controlled separately;
it can't through this or any other resource in the dump, the same
"remote device ids, not locally actionable" role as the existing
/remotedeviceinfo/vs/0 ignore) and /runn/vs/0 (a single undocumented int
with no supported-values list to interpret). Both added to _AC_IGNORED
rather than guessed at.
2026-07-28 14:09:21 +00:00
Marc Billow fcd34f73e5 Add device support for BESPOKE Cube Air A-VTWW-TP2-21-COMMON (#151)
This board reports no oneUiVersion and no modelNum token any existing
family routed on, so it fell back to unknown -- exposing nothing but power
even though most of its resources (air quality sensors, HEPA filter,
device-active, diagnosis, plumbing hrefs) are already handled generically
by the existing air_purifier registry via the '-VTWW-' modelNum fallback.

The one genuinely new piece is its fan: this board reports wind strength as
numeric codes ("87"/"89"/"90"/"91") on /wind/strength/vs/0 with a separate
modesName array ("SMART"/"MAX"/"WINDFREE"/"Sleep") giving the actual names,
unlike the existing TP1X_DA-AC-AIR family where supportedModes IS the name
list already. Generalized LocalThingsAirPurifierFan to resolve a mode code
through modesName when present (same live-label pattern as climate.py's AC
wind-strength fix, issue #155) instead of adding a second hardcoded fan
class, and added WIND_STRENGTH_FAN reusing the same 'air_purifier_fan'
translation catalog -- both board generations land on the identical
smart/max/windfree/sleep vocabulary already labelled there.

/mode/convenient/vs/0 is empty on this dump and added to COVERAGE alongside
the existing plumbing hrefs this board also shares with the TP1X_DA-AC-AIR
family.
2026-07-28 13:58:08 +00:00
Marc Billow a3d9cce164 Extend AirDresser support to DA_DF_TP2_20_COMMON (#157)
A different board generation from issue #162's DA_DF_A51_20_COMMON, also
carrying the '_DF_' modelNum token and so already routed into the
air_dresser registry -- but reporting two resources #162's board doesn't:

  /st/airdressercourse/vs/0 -- the course table id (Table_00), read the
    same way washer/dryer read /st/washercourse|dryercourse/vs/0. Wired up
    as AIR_DRESSER_COURSE's table_href and added to the global ignore list,
    mirroring that existing pair exactly.
  /airdresseroption/sanitize/vs/0 -- a genuine on/off setting (not covered
    by any existing capability), added as AIR_DRESSER_SANITIZE.

Introducing table_href means the course select's translation_key is now
always the table-lookup callable, so the bare 'air_dresser_cycle' catalog
entry added for #162 (only ever used when no table_href was passed) is
unreachable in every case and is removed -- both boards fall back to the
shared 'cycle' entry until their course tables get named, same as
washer/dryer's own precedent for an unrecognized table.
2026-07-28 13:50:59 +00:00
Marc Billow 053e15bba6 Add device support for Samsung AirDresser DA_DF_A51_20_COMMON (#162)
This board reports no oneUiVersion and no modelNum token any existing
family routed on, so it fell back to the global unknown-device CAPABILITIES
set -- exposing only power/child-lock/start-stop-pause/delay/energy/machine
state, with /course/vs/0, /diagnosis/vs/0, and /washer/vs/0 all unbound and
no course/mode select at all (the actual reported gap).

Every one of those resources turns out to already be handled by the shared
laundry machinery: /diagnosis/vs/0 reuses dishwasher.DIAGNOSIS, and
/course/vs/0's cycle select works unmodified through laundry.cycle_options'
existing supportedOptions fallback (this board has no /wm/editcourse/vs/0
at all, so editCourseList never populates). /washer/vs/0 gets a new minimal
AIR_DRESSER_SETTINGS capability (wrinkle_prevent only) rather than reusing
dryer.DRYER_SETTINGS wholesale, since this device never reports
dryLevel/dryTime/dryerType at all and binding them would ship three
permanently-unavailable sensors.

Course codes aren't identified yet (no code->name mapping was reported), so
they render as their raw codes until named in translations, same as
dryer.py's precedent for unidentified codes.
2026-07-28 13:45:49 +00:00
Marc Billow aa9cdd83b7 Read AC fan speeds from the device's own modesName, not just 0-4 (#155)
TP1X_DA-AC-RAC-01001_0000 (model AR07C9150HZN) reports /wind/strength/vs/0
supportedModes as "0"/"31"-"35" instead of the "0"-"4" scale climate.py's
_DEVICE_TO_FAN was built from. Only "0" matched, so fan_mode/fan_modes
silently dropped every speed but Auto -- exactly the reported symptom.

Rather than hardcoding a second numeric scale, codes _DEVICE_TO_FAN doesn't
cover now fall back to the device's own modesName label (parallel-indexed
with supportedModes), mirroring how preset_mode already resolves dynamically
off a device's own supportedModes instead of a per-model table. Boards using
the standard 0-4 scale are unaffected -- _DEVICE_TO_FAN is still tried
first, so existing auto/low/medium/high/turbo labels don't change.
2026-07-28 13:38:42 +00:00