Marc Billow d83733a670 fix(airconditioner): scale legacy ARTIK051 cumulativePower correctly (#193)
ARTIK051_KRAC_18K-generation boards report /energy/consumption/vs/0's
cumulativePower in centiwatt-hours, not the plain Wh every other AC board
family reports -- confirmed against the reporter's own SmartThings-app
reading (raw 117430000 vs. the app's authoritative 1,174.30 kWh is exactly
a /100000 factor, not the shared wh_to_kwh's /1000 alone). Split
common.ENERGY_METER into generic/legacy variants on the airconditioner
registry, discriminated by the existing is_legacy_board() check, so every
other AC family keeps the unmodified shared capability.