Rebased onto PR #36's merge (temperature fallback for /temperatures/vs/0,
display-light switch). Reconciliation, per Opus review:
- Dropped our duplicate LIGHT capability in favor of PR #36's DISPLAY_LIGHT
(same href/entity, cosmetic differences only).
- Dropped /option/muteonce/vs/0 and /selfcheck/vs/0 from the ignore list
PR #36 added -- both have confirmed, cleanly modelable contracts (a plain
On/Off field, and a documented Start/Cancel self-check action already
covered by the existing fridge.SELF_CHECK pattern), so keeping our bound
versions instead of ignoring them. This also picks up mute_once/selfcheck_*
on PR #36's own TP1X_DA-AC-RAC-01011 fixture -- regenerated its golden.
- Deduped the ~10 housekeeping hrefs both branches independently ignored.
- Added a unit test for climate.py's _temps_vs_item (the temperature-
fallback selection logic), which had no coverage -- climate.py isn't
importable in the registry-level AC tests, and the existing "no unbound
hrefs" tests only exercise binding, not the fallback itself.
Closes the coverage-gap repair for two more room-AC boards (issues #37,
- TP2X_RAC_20K reports no oneUiVersion and no '_PRAC_' modelNum token, so
its device type went unrecognized -- add a '_RAC_' fallback token to
for_device_by_model.
- Bind the resources both dumps actually populate: mute-once (switch),
display light (switch), self-check (reused from fridge.SELF_CHECK), and
the circuit-breaker current-limit setting (read-only diagnostic sensors,
since its write contract isn't confirmed from the dump).
- Ignore the rest as plumbing/opaque/unconfirmed: control-set descriptor,
keepnormalstate flag, software-reset trigger, AI Sleep handshake,
absence-monitoring stubs, remote-data-control, remote-temperature,
reservation ruleset, and the welcome-temperature tracker.
Adds scrubbed fixtures + goldens for both dumps and extends the AC
capability/golden-regression tests to assert zero unbound hrefs.
Clears the 'Node 20 is being deprecated' warnings by moving the actions
we pin to their current Node 24 majors (both released 2026-07-20).
hassfest@master and hacs/action@main are third-party and float on their
own branches.
The suite was never run in CI (only hassfest/HACS), and requirements-dev
listed only pytest + smartthings-local while conftest.py needs the full
Home Assistant test harness.
- requirements-dev.txt: add pytest-homeassistant-custom-component (pulls
in home-assistant + pytest + pytest-socket) and the integration's
runtime deps (cbor2, pyOpenSSL, cryptography) needed to import it.
- .github/workflows/validate.yml: add a Pytest job on Python 3.14
(current Home Assistant's floor) that installs requirements-dev and
runs the suite.
- test_config_flow.py: the UDP liveness-sweep test needs real loopback
sockets, which the HA harness blocks by default; take the pytest-socket
socket_enabled fixture so it runs instead of erroring.
Full suite: 249 passed.
Review follow-up. An explicit exists_fn bypasses entity._is_included's
empty-{} stub carve-out, so the sentinel-aware energy meter would drop
power_watts/energy_kwh when /device/0 returns a not-yet-fetched stub for
/energy/consumption/vs/0. Restore the carve-out (`not rep or ...`), and
hide power_watts when instantaneousPower is absent from a populated rep
(not just when it's the -500 sentinel) so a partial rep can't spawn a
phantom power sensor.
First full dryer dump (issue #14, DV90BB5245AES1) surfaced 5 unbound
hrefs and an "incomplete capability coverage" repair. Handle them and,
while here, make the washer/dryer/dishwasher families consistent instead
of each carrying a bespoke variant of the same controls.
Dryer coverage:
- /power/0, /kidslock/0, /remotectrl/0: bind via the OCF-native + vendor
fallback pairs (prefer the standard OCF resource, fall back to -vs).
- /buzzersound/vs/0: new Buzzer sound select.
- /course/vs/0: cycle select shared with washer/dishwasher; ignore the
/st/dryercourse/vs/0 re-encoding (mirror of /st/washercourse/vs/0).
Consistency / de-duplication:
- Move generic OCF controls (power/kids-lock/remote-control fallback
pairs, energy meter) into common.py; every registry uses them.
- Move shared laundry controls (buzzer, job-beginning-status, and the
/course/vs/0 cycle-select machinery) into laundry.py; washer and
dishwasher stop hand-rolling their own copies.
- Energy meter is now sentinel-aware everywhere: the dead '-500'
instantaneousPower reading no longer shows a misleading 0 W (fixes it
on dryers and dishwashers, matching the earlier washer fix).
- Job-beginning-status reads x.com.samsung.da.currentStatus, the field
every dump actually carries; the dryer sensor was previously blank.
Adds a scrubbed dryer fixture, golden, and capability tests, plus an
.claude/skills/adding-device-support skill capturing the dump-reading,
OCF-vs-vendor, entity-taxonomy, and coverage workflow. Bumps to 0.6.0.
The config flow only probed 49154/49155, so appliances whose local
CoAP/DTLS API binds elsewhere in the ephemeral range (e.g. a dishwasher
answering on 49153) could never be added.
Add a fast UDP liveness sweep across 49152-49160 that uses the ICMP
port-unreachable / ECONNREFUSED asymmetry to find the live port(s)
before attempting the expensive DTLS handshake. Closed ports fall out
immediately; a live-but-silent port is kept as a candidate. The real
handshake then runs only against discovered ports, preferring the
historically known 49154/49155 when several look live.
Also drop the probe's /device/0 GET deadline from a bare 15s literal to
a named PROBE_GET_TIMEOUT_S constant (10s) — the slowest observed full
dump is ~8s, and 10s matches the per-resource read timeout used
elsewhere.
Bumps version to 0.5.0.
machine_state was rendering the raw lowercase OCF values (idle/active/
pause) untranslated in the UI. Add device_class=enum, options, and a
translation_key matching the existing pattern used by ice_making_status
and connection_mode, in both the shared operational.py capability and
oven.py's separate machine_state sensor.
Bump patch version for this fix plus the ice_type 'off' translation and
iot_class correction earlier on this branch.
The refrigerator fixture's x.com.samsung.da.iceType.supported list
includes "Off" alongside the whiskey_iceball_* values, but strings.json
only translated the whiskey_iceball options, leaving "Off" to render
untranslated in the ice-type select.
Coordinator prefers CoAP OBSERVE push notifications (observe.py) over
polling when the device supports it, falling back to polling only when
observe mode isn't available or drops.