Marc Billow 9d28b088cb laundry: cover a device that advertises cloud cycles it has never loaded
A survey of every laundry diagnostics dump attached to an issue turned up 14
devices, 4 of which carry cloud-course tokens. Two were already known; the
two new ones are both useful, and one contradicts something the
investigation write-up asserted.

A DW5000C dishwasher (issues #113/#123) advertises four downloaded programs
and carries no payload token for any of them. That is a shape the corpus
didn't have: the feature is not washer-only (DA_DW, not DA_WM), and a device
can name programs whose payloads have never been observed. The existing code
already handles it correctly -- nothing learnable, nothing offered, gap still
counted for the Repairs issue -- so this adds the fixture, golden, and tests
that keep it that way.

A second WW5000C (issues #259/#343, firmware _B048) holds the same saved
program as the first one's captured "Towels", and the two payloads differ at
exactly one byte: byte 3, 04 against 06. Everything else -- id, slot, all
four varying tag values, the whole tail -- is identical. So byte 3 is neither
a per-board constant nor a property of the program, and the doc's claim that
it is always 04 on this board was wrong.

That is also the strongest argument yet for learning payloads per device: a
catalog keyed on program id would have shipped one unit's byte 3 to the
other. Nothing changes in the implementation as a result -- it never had a
catalog -- but the reasoning is now backed by evidence rather than caution.

Also recorded: both WW5000C units advertise the byte-identical slot list
despite different firmware, so the program set looks factory- or
region-assigned rather than user-curated; and a sentinel's byte 2 equals the
selected course on one dump but not the other, so it stays unused.
2026-08-09 21:46:29 +00:00
Marc Billow f45bd6a72c laundry: discover and offer cloud "Download" cycles (issue #342)
A washer whose course table includes "Download"/"Downloaded" runs whichever
program the SmartThings cloud last pushed down. Those programs are now
selectable from the ordinary cycle select, so a downloaded Jeans or Sports
cycle can be started without giving the appliance internet access.

The device turns out to enumerate them itself. `CloudExtraCourse_` on
/course/vs/0 lists one byte per downloaded program, and byte 2 of a
program's payload is exactly that slot id -- verified against all nine
programs on the reporter's WW5000C and against the WA55A7700AV dump already
in the corpus. So nothing here is hardcoded: the appliance says which
programs exist, the payloads are learned by watching what it reports, and
the names come from the user.

That last part is unavoidable rather than a shortcut. A payload is only
visible while its program is loaded, and the appliance never reports a name
for one. So cloudcourse.py persists what has been seen (same rationale as
learned.py's mode store), a Repairs issue tells the owner how many programs
are still unaccounted for, and an options-flow step collects the names. A
program appears in the cycle select only once it is both learned and named.

Selecting one issues the only two-token options write in the codebase --
the course token has to switch to Download in the same write, or the
appliance accepts the program token and silently ignores it (confirmed on
hardware). The Download course code is learned by observation but never
applied until the user confirms it: tokens in this array are replaced by
prefix and never evicted, so a stale program token can appear alongside an
unrelated course, and acting on that would start the wrong wash cycle. For
the same reason a stale token is never reported as the running program.

Also of note:

- There is no single "Download" course code. The WW5000C uses 87, the
  WA55A7700AV uses 17 -- same Table_02. Any per-table lookup would have
  been wrong on one of the only two devices available to check.
- Payloads are replayed byte-for-byte and never decomposed or rebuilt.
  Bytes 5/7/9 do decode to temperature/rinse/spin on the WW5000C, 9 for 9,
  and produce nonsense on the WA55A7700AV -- so that decode is written up
  in docs/investigations/download-cycle.md and not shipped, and the
  read-only sensors it would have enabled were dropped.
- The store reaches the registry as a namespaced synthetic field merged
  onto /course/vs/0's rep at read time, so exists_fn/rep_fn/options/write_fn
  all see it through their existing signatures. It never enters the state
  cache, so it can't be polled over, written to the device, or land in a
  diagnostics dump.
- A name that would render identically to another cycle in the same
  dropdown is rejected in the flow: the select maps a chosen label back to
  a raw value by matching display text.

Non-English catalogs carry the new strings in English for now; they need
real translations.
2026-08-09 21:21:10 +00:00
Marc Billow 1f7bdc9ac6 fridge: give DEODOR_FILTER its own entity keys, not AIR_FILTER's (code review)
DEODOR_FILTER reused AIR_FILTER.entities verbatim, so both capabilities
produced identically-keyed entities (air_filter_usage/air_filter_status)
despite living at different hrefs. adapter.flatten()'s key derivation has
no href component, so a unit reporting both /filter/airdustfilter/vs/0
and /filter/deodorfilter/vs/0 would silently clobber one filter's reading
with the other's -- the exact collision AIR_FILTER's own 'air_' prefix
was chosen to avoid against WATER_FILTER's filter_usage/filter_status.

Gives DEODOR_FILTER its own deodor_filter_usage/deodor_filter_status keys
(status still shares the filter_status translation_key, same as AIR_FILTER
already does). Updated the winecellar fixture's golden and test, and added
deodor_filter_usage to all seven translation catalogs.
2026-08-09 01:21:17 +00:00
Marc Billow 5e2c23a62d Add device support for dual-cavity range TP1X_DA-KS-RANGE-0101X (issue #324)
This board (NE63T8751SG/AA-class) reports no /information/vs/0 at all --
the modelNum-based routing fallback has nothing to read -- so it fell
back to 'unknown' and lost the whole range registry (oven mode/setpoint/
door/connected, cooktop monitoring). /oic/d does carry oic.d.range,
though, so this is a routing fix, not a new capability: adds 'oic.d.range'
to _OIC_TYPE_TO_KEY.

The second oven cavity is a genuine Pattern A indexed subdevice at
/device/1 (issue #177's mechanism) -- once routing resolves the master to
the range registry, the same registry already applies to the subdevice's
canonical view and every href on both binds with zero gaps.

_discover_full gains an optional device_types param (default (), every
other fixture unaffected) so a fixture that can only route via /oic/d can
exercise the same subdevice-aware pipeline the other composite fixtures
already do.
2026-08-09 00:58:26 +00:00
Marc Billow b6f0bc22cb Add device support for Samsung Refrigerator TP1X_REF_21K auto-door variants (issue #328)
Three new dumps from one household's TP1X_REF_21K fleet (regular
single-door, kimchi, wine cellar) exposed the Auto Door Open feature's
timer and voice/sound feedback toggles, plus wine-cellar-specific
coverage: a deodorizing filter at its own href, a multi-compartment
pantry select, and a table-revision info resource.

- STATUS_LOCK gains auto_door_voice_control/auto_door_sound_control,
  gated on each field's own presence.
- New AUTO_DOOR_TIMER (a discrete-options select, same shape as the
  DEFINITE_TEMPERATURE_COOLER/FREEZER pattern) and three no-entity
  AUTO_DOOR_SINGLE/KIMCHI/WINECELLAR coverage hrefs -- every dump seen
  reports exactly one openOptions value with no paired current/desired
  field to choose against.
- New DEODOR_FILTER (reuses AIR_FILTER's entities at a different href),
  WINECELLAR_PANTRY_ZONE, and WINECELLAR_INFO.
- by_type: oic.d.krefrigerator and x.com.st.d.winecellar routed to the
  refrigerator registry via /oic/d, alongside the existing modelNum-based
  routing.
- kimchi_zone_mode's translation catalog gains three supportMode codes
  (bare storage_fridge/storage_freezer without the _normal suffix, and
  the apparently-placeholder newmode_kimchi_0000) surfaced by the kimchi
  fixture, across all seven languages.

Three new scrubbed fixtures + goldens + tests, one per variant.
2026-08-09 00:57:36 +00:00
Marc Billow a7dc1db8ff Extract usable parts of PR #316 (System Fresh Air Ventilator support)
PR #316 (fork stale by several months, most of its ~2200-line diff was drift
against main rather than real changes) proposed device support for the
Samsung System Fresh Air Ventilator (ACA-KR-TP2-21-AN9000). Extracted what
holds up, adapted to this project's conventions, and left out what doesn't:

Extracted:
- ventilation_mode select on CLIMATE's own href, gated via
  _is_ventilation_mode_device so it can only ever bind on a device whose
  entire supportedModes set is Purification/Ventilation/SmartVentilation --
  verified against every real AC fixture in the corpus to confirm it can't
  false-positive on an actual air conditioner's climate card.
- WINDFREE / WINDSLEEP switches on their own dedicated hrefs.
- A CO2 sensor on AIR_QUALITY, matching air_monitor.SENSORS' already-bound
  device_class='carbon_dioxide'/unit='ppm' descriptor for the same field
  shape rather than guessing fresh.
- HEPA_FILTER / DEVICE_ACTIVE reuse from air_purifier.py.
- Removing /airlevelcheck/vs/0 from _AC_IGNORED and binding
  air_purifier.AIR_LEVEL_CHECK in its place: the PR's claim that this
  project's old "scheduler plumbing" description was wrong turned out to
  be independently verifiable against two of our own existing fixtures
  (airconditioner_cac and airconditioner_tp1x_da_ac_rac_01011 both already
  carry real, populated periodicSensingActivationState/autoExeState
  values), so this benefits existing users, not just the one new device.

Left out:
- Unit/device_class ('ug/m3', pm10/pm25/pm1) on the existing dust/
  fine_dust/super_fine_dust sensors, sourced from an unverified third-party
  screenshot description. air_monitor.py already has an explicit, reasoned
  rejection of this exact mapping for the exact same three fields:
  Samsung's PM10/PM2.5 convention doesn't confirm where a third tier or a
  PM1 reading fits, and a wrong guess mislabels the reading forever.
- A standalone common.POWER switch -- contradicts this registry's own
  documented design (power is deliberately the climate entity's job) and
  would affect every AC user, not just this device.
- Promoting wind/swing to independent selects for every AC user -- a UX
  opinion, not a coverage necessity, and out of scope for this device's
  own support.
- A model-name diagnostic sensor -- /information/vs/0 is already covered
  via the global ignore list, so this wasn't closing an actual gap.

No raw diagnostics dump for this model was ever attached to PR #316, so
there's no fixture for it here (fabricating one would violate this
project's fixture-integrity rule) -- see
tests/test_airconditioner_ventilation_windfree.py's module docstring.
2026-08-07 16:38:09 +00:00
Marc Billow e2dcc75ed5 Address Opus review findings on the device-support commits above
- Fix a real bug: airconditioner.SOUND_MODE had no exists_fn, so on
  boards (issue #319's FAC) that never report a live 'mode' value,
  entity.py's default field-presence gate silently kept the select from
  ever registering in HA -- while adapter.flatten() (what the golden/tests
  read) has no such gate, so the tests passed while documenting behavior
  the opposite of what shipped. Gate on supportedModes' presence instead.
- Add airconditioner.MDS_ABSENCE_CLEAN for the CAC-class board's
  /mds/absenceclean/vs/0 -- byte-identical shape to issue #319's
  /csi/absenceclean/vs/0, confirmed rather than guessed, closing one more
  of that board's documented coverage-gap hrefs.
- Add missing translation state labels (all 6 languages) for
  edge_lighting_mode/edge_lighting_color/indicator_light_mode's raw device
  codes, so they render as real words instead of a raw '3000K' -> '3000 K'
  fallback.
- Fix an orphaned comment above SOUND_MODE that actually described the
  unrelated DISPLAY reuse, and correct two inaccurate rationale comments:
  the sound/voice ignore reason claimed a distinction from SOUND_MODE that
  this same dump contradicts, and the /csi/* ignore block's 'same
  reasoning as air_purifier.COVERAGE' precedent only actually covers 1 of
  its 5 hrefs.
- Correct the false 'no board-token match' claim in the FAC test file and
  golden-regression docstring -- 'FAC' is a real _BOARD_TOKEN_TO_KEY entry
  (for_device_by_model alone already resolves this board); add a test
  that actually exercises that path, which nothing previously did despite
  the docstring's claim.
- Drop a tautological burner-slot test that only re-asserted what the
  golden regression test already covers via the same code path.
2026-08-07 14:50:24 +00:00
Marc Billow c203bd42c5 Add edge-lighting and indicator-light support for TP1X_DA-AC-CAC-01001 (issue #288)
Six System A/C cassette units on the same board test_airconditioner_cac.py
already documented as having an incomplete coverage gap gave real dump
evidence for two of its remaining unbound hrefs:

- /edgelighting/vs/0: an accent-light strip with on/off, a Smart/High/Low
  mode, and a Kelvin color-temperature select (3000K/4000K/6500K), all read
  from the device's own live supported-value lists.
- /light/stateful/vs/0: a second, distinct light resource with its own
  on/off and Smart/Low/High mode -- not to be confused with EDGE_LIGHTING
  or DISPLAY_LIGHT's ambient mood light.

convenientMode/operatingOption on /edgelighting/vs/0 stay unexposed: present
on every dump but no evidence of what either actually controls.

Only three hrefs remain in test_airconditioner_cac.py's documented gap now
(absence-clean, sound-optimization, smart-sensing-cooling).
2026-08-07 14:27:25 +00:00
Marc Billow 42fd9c2aa4 Close coverage gap and fix phantom lamp switch for TP2X_DA-KS-WALLOVEN (issue #300)
/diagnosis/vs/0 was the dump's only unbound href, now covered via
dishwasher.DIAGNOSIS (same shape already reused by airconditioner.py).

This steam-oven-class board's /mode/vs/0 options[] carries no UpperLamp_
token at all, unlike the NV7000BS-class board LAMP was proven against --
LAMP had no exists_fn, so it registered anyway, always read Off, and any
write to it was a no-op the device had no reason to honor. Gives it the
same options-token exists_fn gate issue #183 already added to
fast_preheat/natural_steam/energy_saving/cooktop_on_alert.
2026-08-07 14:22:32 +00:00
Marc Billow df5b704f3e Close gas-cooktop coverage gap for TP2X_DA-KS-COOKTOP-000001 (issue #314)
/alarms/vs/0 and /kidslock/vs/0 were the dump's two unbound hrefs -- both
are the exact shapes common.UNIVERSAL already models elsewhere
(common.ALARMS, common.KIDS_LOCK_VS_FALLBACK), picked individually rather
than pulling in all of UNIVERSAL to match this registry's existing
hand-picked-common style.

The six-vs-three burner count the reporter originally asked about is
expected behavior (the board's own /mode/vs/0 options genuinely advertise
six OperationState slots on hardware with three physical burners, with no
per-device signal to tell real slots from phantom ones) -- already
explained on the issue; this commit is scoped to the coverage warning.
2026-08-07 14:18:08 +00:00
Marc Billow 26c9168fb7 Add internal air-filter support for TP1X_REF_21K refrigerators (issue #318)
/filter/airdustfilter/vs/0 was the dump's only unbound href -- this board's
internal deodorizing filter, same filterUsage/filterStatus field pair as
common.WATER_FILTER, but filterUsage here is already a 0-100 percentage
with no filterCapacity to divide by (confirmed by filterStatus=="wash" at
filterUsage=="100"). Uses air_-prefixed keys so a fridge with both a
water and an air filter gets two distinct entities.
2026-08-07 14:13:38 +00:00
Marc Billow edf77309ba Add device support for AILP_DA-AC-FAC-02011 air conditioner (issue #319)
This board routes purely via /oic/d's oic.d.airconditioner type (no
board-token match) and reports several resources the sibling
TP1X_DA-AC-CAC-01001 board (issue #191) left as a documented gap:

- /display/vs/0, /settings/sound/output/vs/0, /settings/sound/volume/vs/0
  now reuse air_purifier.py's identical-shape capabilities instead of
  duplicating them.
- /settings/sound/mode/vs/0 gets a new airconditioner.SOUND_MODE reading
  the live supportedModes field, sharing laundry.py's existing
  voice/tone/mute translation catalog since the value vocabulary matches.
- /csi/absenceclean/vs/0 and /csi/energysaving/vs/0 are new, genuinely
  useful controls (absence auto-clean toggle, energy-saving mode select
  plus its state/operatingStatus diagnostics).
- /dnd/autosleep/vs/0, /outdoorsharing/vs/0, /lifestyle/survey/vs/0,
  /settings/sound/voice/vs/0 and /csi/information/vs/0 are ignored as
  plumbing/unconfirmed data with no user-actionable state.

Also fixes a latent bug in air_purifier.SOUND_VOLUME: boards that report
minLevel/resolution but no maxLevel (this one) would have produced a
min=0/max=0 number entity instead of self-gating off.

Updates test_airconditioner_cac.py's documented coverage gap now that
sound_mode/sound_output/sound_volume are covered there too.
2026-08-07 14:10:13 +00:00
Marc Billow ccdfe7088e Merge pull request #281 from atc722/agent/nv9000d-regression-fix
Fix read-only sensor categories and add NV9000D coverage
2026-08-04 21:40:03 -04:00
Marc Billow b59b5ae1b4 Merge pull request #290 from perseus177/ac-autoclean-stop
feat(airconditioner): stop a running auto clean, and read its progress
2026-08-04 20:53:44 -04:00
perseus177 290a348017 feat(airconditioner): stop a running auto clean, and read its progress
Three tokens describe the drying cycle these boards run after cooling, and the
switch only covered the first. AutocleanProgress_ is how far a running cycle
has got, and StopAutoClean_ is a channel for ending one early -- its presence
is what says the appliance accepts that at all, which is how the appliance's
own app gates its stop button. Both tokens are reported by the ARTIK051_KRAC_18K
that issue #136 was about, and by every KRAC fixture here.

The percentage scale is the app's own: it renders the token into a
`<progress max="100">` with a "{{value}}%" label beside it. An idle unit reports
1 rather than 0 -- the same floor the laundry firmware's progressPercentage sits
at when Ready -- so 0-vs-1 is not a reliable "is it running" test, and the
button is deliberately not gated on it.

The sensor shares AUTO_CLEAN's catalog entry the way auto_clean_legacy already
shares the switch's: same figure, different board generation, distinct key so
nothing collides if a board ever reported both.

Stacked on #289 (this branch is cut from it) -- rebase or merge that first.
2026-08-05 00:45:20 +02:00
hoon 3d0dca20f9 Add NV9000D cooktop coverage and fix sensor setup 2026-08-04 14:47:42 +09:00
kkqq9320 412fff9b99 feat(air_purifier): expose the AI Purify sensing engine on /airlevelcheck/vs/0
/airlevelcheck/vs/0 has been covered as "periodic air-quality sensing
scheduler plumbing" since the registry gained a coverage stub for it. Two
AVT-WW-TP1-23-AXX500 dumps (issues #84 and #190) show it is not plumbing: it
drives the feature the SmartThings app calls AI Purify, where the unit wakes
on a timer, samples the air, and optionally acts on the result. Every field
is named, none are opaque, and two of them are already user-set on the
reported units.

The select's three on-states are the app's own options rather than an
invented grouping -- it offers exactly "Sensing only" (sample, take no
action), "Auto clean" (purify while the air reads bad, stop once it
improves) and "Get notified" (raise a SmartThings notification). Labels were
transcribed from the Korean app and rendered in English; the auto-stop half
of "Auto clean" is the app's own description and is not otherwise visible in
the dump, which reports only the selected autoExeState. The remaining entity
names follow their raw fields rather than inventing a concept -- the skip
window is "sensing skip", after periodicSensingSkipStatus/Time.

Three of this registry's four board families report the resource with the
same field names -- TP1X_DA-AC-AIR (#130), A-VTWW-TP2 (#151) and AVT-WW-TP1
(#84, #190). Only ARTIK051_TVTL (#56) has no such href, and its golden is
unchanged. Bound unconditionally rather than behind a match_fn; the one field
that genuinely varies (periodicSensingInterval, absent on the #130 board) is
gated per-entity, so that board gets eight entities instead of nine rather
than a broken one.

range_hood.AIR_LEVEL_CHECK already models this same href, and its read-only
keys are reused verbatim here so both families share one catalog entry. It is
deliberately not imported: the hood exposes periodic_air_sensing as a
read-only BinarySensorDesc and this board needs a writable SwitchDesc on that
key, so reusing the hood's capability would migrate every hood user's entity
to a different platform.

Every write was exercised on AVT-WW-TP1-23-AXX500 hardware. This board hands
out 2.04 for writes it silently discards (see HEPA_FILTER's filter-reset
note), so an echo proves nothing -- each was judged by whether the value
survived a reconnect, which forces a new DTLS session, fresh discovery and a
fresh observe of the href, leaving no cached state to read back:

  * sensing_mode's combined two-field PUT lands both fields, both ways:
    sensing_only -> auto_purify raises autoExeState with activation still On,
    and back again lowers it.
  * The sensing-skip switch holds Off -> On and back.
  * The half-preserving time writes hold: from 13:00-23:00, writing
    start=07:30 then end=22:00 left the device on '07302200' -- each write
    kept the half it wasn't given.
  * periodic_air_sensing and sensing_interval: writing 60 s drove an observed
    ~60 s sensing cycle.
  * The read side of the skip window is separately cross-confirmed on two
    units: #84's sits at the inert '00000000', #190's carries a real
    '03002300' (03:00-23:00), which is what pins the HHMMHHMM split.
  * The other two families get the writes on field-shape grounds -- the same
    basis on which they already share MODE, HEPA_FILTER and the air-quality
    sensors.

range_hood._timestamp moves to common.epoch_to_utc so both callers share it,
matching how filter_usage_percent was shared. No behaviour change.

Every existing entity is untouched: the three golden updates are purely
additive, no renames, no unit or device_class changes.
2026-08-04 12:57:03 +09:00
Marc Billow fb5ed32b0f Add discrete freezer setpoint support for TP1X_REF_21K (issue #229)
The reporter's fridge/freezer combo reports the issue #186 discrete
definite-setpoint pattern on both compartments, but only the cooler half
was modeled -- /temperature/definite/freezer/vs/0 was unbound. Adds
DEFINITE_TEMPERATURE_FREEZER, identical shape to the existing cooler
capability (same fields, just negative supportedList values).
2026-08-03 19:24:59 +00:00
Marc Billow e6d7dcddc8 Add dryer Drum Clean+ tracking; fix multi-entry DrumCleanLog parsing (#258)
Dryers report the same DrumCleanProposal_/WashingTimes_/DrumCleanLog_
options[] tokens washer.py already models for issue #9, so
drum_clean_cycles_remaining/drum_clean_last_cleaned move to laundry.py and
get bound on dryer's /course/vs/0 too.

DrumCleanLog_ on the reporter's dump is a '|'-joined history of every past
clean rather than washer's single bare timestamp -- the shared helper now
takes the last (most recent) entry, which turns out to also fix a latent
bug on four existing washer fixtures whose own DrumCleanLog_ was already
multi-entry and silently failing to parse into drum_clean_last_cleaned.

No heat-exchanger-clean tracking was found in either dump #258 supplied;
noted in dryer.py so a future report knows this was checked.
2026-08-03 19:14:29 +00:00
Marc Billow cf09247e39 Add AC UV LED, ventilation alarm, and PM1 filter support (issue #270)
TP1X_FAC_TIME_23K reports three previously unbound hrefs: a UV-C
sterilization LED and a ventilation-reminder alarm (both plain On/Off
toggles), and a second PM1-rated dust filter with no live usage/status
fields on this particular dump.

The PM1 filter capability gates each entity on its own field's presence
rather than a blanket ignore, since the TP1X_DA-AC-CAC-01001_0000 cassette
AC (issue #191) reports the same href with full live data -- this also
closes two of that device's ten documented coverage gaps (UV LED and the
PM1 filter) as a side effect.
2026-08-03 19:07:03 +00:00
Marc Billow 3ef64eae52 Add dehumidifier display switch and watertank lighting (issues #271, #231)
The TP1X_DA_AC_DHM_01001_0000 revision (model AY70H18100GTD) additionally
reports /display/vs/0 (same shape as air_purifier's screen toggle, reused
directly) and /watertank/lighting/vs/0 (on/off, color, and brightness for
the tank's ambient light, plus a diagnostic alarm-status flag). Both issues
submitted the identical dump, so one fix covers both reports.

Also adds x.com.st.d.dehumidifier to the /oic/d device-type routing table
now that a dump confirms it.
2026-08-03 18:59:22 +00:00
Marc Billow 42a1812967 Merge pull request #261 from mbillow/claude/pr-242-review-merge-nny8ug
feat: discover UUID-prefixed subdevices advertised only via /oic/res (Pattern C, #241)
2026-08-02 17:42:46 -04:00
Hyunook 6bcf8f3bec feat: discover UUID-prefixed subdevices advertised only via /oic/res (Pattern C, #241)
AWM-WW-AID-26-ONEBODY (washer+dryer combo) reports numofsubdevice='2' on
/multidevice/vs/0 but carries no /subdevices/vs/0 (no subdeviceIdList --
Pattern B's signal) and 4.04s /device/1 and /device/2 (Pattern A's). The
washer subdevice's UUID appears only as the path prefix of the
x.com.samsung.da.multidevice link in /oic/res; GET /<uuid>/device/0
answers the washer's own full Collection batch (model ..._WF80H vs the
master's ..._DV80H27H).

Treat every UUID path prefix seen in /oic/res as a prefixed-subdevice
candidate (minus ones subdeviceIdList already named), probed with the
same tolerated-404 seed RETRIEVE as Pattern B -- the shared body is
factored into _probe_prefixed. discover_partitioned's entity-level
liveness gate still decides materialization, so a UUID link with no live
sibling behind it contributes nothing.

Fixture is a live capture from the reporting board (serials/MACs/di
scrubbed); tests cover discovery, probe hygiene, washer-side entity
binding, and that the master's own entity set is unchanged.
2026-08-02 21:40:34 +00:00
Ian P. Christian 6efee761d9 Add Samsung EHS (Eco Heating System) heat pump support
Adds a device registry for the TP1X_DA_AC_EHS board family: separate
zone1 (space heating/cooling) and dhw (domestic hot water) loops.
zone1 is exposed as power switch + mode select + current/target
temperature sensor/number -- it's a leaving-water-temperature
setpoint, not a thermostat, so no HA platform fits it better. dhw
gets a composite water_heater entity, using the same
primary-resource-plus-sibling-reads shape climate.py already uses
for the AC (PR #247 review feedback: "Having water heaters
automatically leverage the right platform would be pretty cool!").
The unit's away mode is a device-wide switch, not the water_heater
AWAY_MODE feature -- /option/outgoing/vs/0 has no dhw-scoped sibling
and covers zone1 too, so presenting it on the DHW card would
misstate its scope.

Operation modes (Eco/Std/Force/Power) map onto HA's own standard
water_heater states, the same mapping HA core's smartthings
integration uses for this exact Samsung capability over the cloud
API. Device codes are matched case-insensitively on the read side.
The DHW entity takes a catalog name ("Hot water") rather than the
bare device name -- unlike the AC's climate card, it is one loop of
a two-loop device.

Both temperature ranges fall back as a pair: a resource reporting a
minimum but no maximum yields no range at all rather than mixing a
device bound with an invented default, matching climate._range().
Increment fallbacks test for None instead of using `or`, so a
genuine 0 survives.

set_temperature honours the optional operation_mode HA's
water_heater service schema forwards, setting the mode (and powering
the loop on) before the setpoint, the same way climate's
set_temperature handles hvac_mode.

Entity names are translated into Czech and Dutch following each
file's existing terminology conventions.

Verified against a real TP1X_DA_AC_EHS_01001_0000 diagnostics dump
(firmware AEH-WW-TP1-22-AE6000_17260402); golden-regression fixture
and full test coverage included.
2026-08-02 22:18:43 +01:00
Marc Billow e309d3e7b8 Merge pull request #225 from atc722/agent/qooker-support
Route Samsung Bespoke Qooker to microwave registry
2026-08-02 12:22:10 -05:00
Geunwon Mo 5c275753d4 Report whether the auto-clean cycle is running, and how far through
`/option/autoclean/vs/0` carries three fields and only `settingStatus` was read.
That one says the feature is enabled, which it is whether or not the unit is
drying right now, so nothing reported an actual cycle.

    settingStatus: On      <- the existing auto_clean switch
    status:        Stop    supportedStatus: [Start, Stop]
    progress:      0

Adds a binary sensor for `status` and a percentage sensor for `progress`.

Measured on a TP1X_DA-AC-CAC-01001, sampling the resource every eight seconds
across a cycle: `Start` with progress 98 while it ran, then `Stop` with progress 0
the moment it finished. The percentage matches the figure the appliance shows on
its own display, checked against 55% mid-run.

Golden state keys updated for the 18 fixtures that bind AUTO_CLEAN. The change is
additive — no key was removed from any of them.

Full suite passes (1070 tests, Python 3.13 via requirements-dev.txt).
2026-08-02 22:01:27 +09:00
hoon f9cd857ced Support Samsung Bespoke Qooker routing 2026-08-01 10:47:00 +09:00
Marc Billow 3c6c7f246f Merge branch 'main' into ac-filter-reset 2026-07-31 20:13:40 -05:00
Marc Billow 6166f63570 Merge pull request #224 from mbillow/claude/issue-triage-batch-h4n2wq
Issue triage batch: #207, #189, #208, #181/#183, #196, #210 + contributing docs
2026-07-31 15:22:55 -05:00
Marc Billow b7d3f86ec7 fix: address code review feedback on issue-triage batch PR (#181, #183, #189, #196, #207, #208, #210)
common:
- Make KIDS_LOCK_GENERIC also a read-only BinarySensorDesc (device_class='lock'),
  flipping value_fn to not bool(v) so /kidslock/0 value=False and
  /kidslock/vs/0 kidsLock='Ready' render with the same polarity ('On'
  means open/unlocked per HA's lock device class). The old SwitchDesc
  form never honored device_class='lock' -- HA's switch platform only
  accepts 'outlet'/'switch' -- so the surface was a plain switch whose
  'On' meaning drifted across boards. Tests updated.

air_monitor:
- Add state_class='measurement' to dust/fine_dust/super_fine_dust so
  the readings feed HA long-term statistics (co2 already had it).
- Import _AIR_QUALITY_SENSORS from air_purifier instead of duplicating
  it byte-for-byte; update common.sensor_item_value's docstring to
  mention the third caller.

by_type/__init__: drop trailing whitespace on the new 'ASM' line.

translations/en.json + nl.json: move the new 'dnd' switch entry to its
correct alphabetical position (after display_light, before fast_preheat).

SKILL.md: add an explicit read-side rule to §5's educated-guesses
section -- guessed unit/device_class/state_class on a SensorDesc
silently mislabels readings forever with no 4.xx to catch it (unlike
guessed writes, which the device rejects). The prior air_monitor
docstring cited this carve-out as if it existed; now it does.

tests/water_purifier (issue #196): change the ailite fixture's
favorite.defaultTemperature from '85' to '50' so the test actually
reproduces the reported bug -- '50' is in showList only, so a
descriptor reading from supportedList would fail the assertion that
the current default is in its options list.
2026-07-31 15:17:18 -05:00
Petr Divis f15ee7e563 Update golden fixtures for the new odor-controller entities
CI caught it: 8 pre-existing AC fixtures also carry genuine SmartCoolClean_/
ProgressSmartClean_ tokens in /mode/vs/0 (lnx_rac_heatpump, ara_ww_tp1_22,
windfree_oscillation, tp1x_rac_01001, fac_bora, fac_bora_2in1,
fac_bora_205_flat, cac), so odor_controller_active/odor_controller_progress
now correctly bind there too -- their golden state_keys lists just hadn't
been regenerated. Verified against the actual downloaded CI job log.
2026-07-31 16:39:08 +02:00
Petr Divis d0c68fb5ac AC: bind SmartCoolClean odor-controller option tokens; add Czech translation
- airconditioner.py: odor_controller_active binary_sensor + odor_controller_progress
  sensor, read from the /mode/vs/0 SmartCoolClean_/ProgressSmartClean_ option tokens
  (SmartThings cloud custom.airConditionerOdorController capability). Read-only --
  no confirmed write command.
- Reporter's TP1X_DA-AC-RAC-01001_0000 dump: fan speed and WindFree preset already
  bind via the existing composite climate entity, no code change needed there.
- en.json/nl.json: new entity names for the two additions.
- cs.json: new, full Czech translation catalog (mirrors en.json topology 1:1).
- New fixture + golden + tests locking in the odor-controller behavior.
2026-07-31 16:02:13 +02:00
perseus177 9ee0dbb8f9 feat(airconditioner): filter alarm interval on legacy ARTIK051 boards
Adds the Select the official app offers next to the filter reminder --
180/300/500/700 hours -- which this board generation keeps as a FilterAlarmTime_
token in /mode/vs/0's options[] rather than on a /filter/* resource.

Confirmed on hardware: stepping through all four radio positions in the app
moved that one token and nothing else across all 19 resources, so the token
carries the hour count verbatim; and a local write of 500 to a unit sitting on
700 was accepted and kept, surviving a restart. The cloud exposes none of this,
so it is only available locally. Gated with the counter it belongs to, so
boards carrying a real /filter/airdustfilter/vs/0 threshold keep using that one
-- the gate is covered by a test that injects the token into a newer board's
dump, since no non-legacy fixture carries it and the assertion would otherwise
pass for the wrong reason.

Also settles what filter_time measures: it counts UP -- running time
accumulated since the last filter reset, not time remaining -- which an earlier
revision of that comment explicitly left open. Three independent things agree:
the token rising while the unit runs, FilterAlarmTime_ being the threshold it
is measured against, and /alarms/vs/0's filter entry tracking the counter
across two units on one site (a live unsuffixed 'FilterAlarm'/'Created' at
FilterTime_5595 against the 'FilterAlarm_OFF'/'Deleted' placeholder at 1915).
The alarm clearing by itself the moment the counter dropped under the threshold
is the causal half of that, not just correlation.

Resetting the counter is NOT solved and no reset entity is added. The
descriptor records what was tried, and what the failures do and do not prove,
so the next attempt starts from evidence instead of from scratch. Short
version: the reset is a *command* (custom.dustFilter/resetDustFilter), not a
value write, which is why nothing that writes the counter works; I could not
work out how to drive that command locally. /actions/vs/0 is the obvious local
command channel but publishes no schema, and I did not enumerate guessed action
names against a live appliance.

Written with Claude (AI), on the author's own hardware; every result quoted
above is measured on the device rather than inferred.
2026-07-31 12:41:40 +02:00
Marc Billow a7d57086e9 feat: add Samsung Air Monitor Plus support (#210)
New device family: a standalone, battery-powered air-quality sensor
puck (ASM-KR-TP1-22-* board) with no controllable-appliance state at
all -- no /power/*, only /energy/battery/vs/0. Routes via both /oic/d
('x.com.st.d.airqualitysensor', confirmed against the real dump) and
the 'ASM' modelNum board token as a fallback.

/sensors/vs/0 reuses air_purifier.AIR_QUALITY's existing {type, value}
items-list decode (common.sensor_item_value) for dust/fine_dust/
super_fine_dust/odor/clean_level, sharing those capabilities' catalog
entries, and adds a CO2 reading those families don't report. The
particulate sensors deliberately get no pm10/pm25/pm1 device_class:
the values read as physically consistent (coarser >= finer) but
Samsung's own two-tier dust naming doesn't confirm where this board's
three-tier split actually maps, and mislabeling a read-side unit is a
standing, not one-shot, kind of wrong -- exposed as plain named
sensors instead. Humidity, battery/charging, and the informational air
quality standard are otherwise straightforward field reads.

/dnd/vs/0 (do-not-disturb window) is a flagged educated guess: the
write contract mirrors the read side's own string/time-format shape
(the safest kind of guess) but has no idle-vs-active dump to confirm
it end-to-end, so it's called out as such in code and will need a
reporter to verify on real hardware. /keepnormalstate/vs/0 and
/sensordatasinks/vs/0 are genuinely opaque (single unexplained value,
no supported-values list) and are ignored rather than guessed at.

Locked in with a scrubbed fixture, golden, and capability tests.
2026-07-31 02:40:02 +00:00
Marc Billow 5bbc7aeece fix(air_dresser): bind /buzzersound/vs/0 on the TP1_21 board (#208)
DA_DF_TP1_21_COMMON reports a plain {setBuzzerSound, supportedFinishSound}
buzzersound resource -- the same shape laundry.BUZZER_SOUND already
handles for washers/dryers -- but it was unbound because the air_dresser
registry never included that capability. Add it, and lock the board in
with a scrubbed fixture, golden, and capability tests.

The reporter's actual complaint (course cycles showing as raw codes) is
a labelling gap, not a coverage one: this board's course table has no
code->name mapping anywhere in the dump, same as issue #162's board, so
there's nothing to bind here -- it needs a reporter to identify the
codes before they can be named in translations.
2026-07-31 02:03:32 +00:00
Marc Billow 5e86f147d4 fix(subdevices): don't materialize a slot whose only live state is a meter
Issue #214: a single-split ARTIK051_KRAC_18K showed up in HA as two air
conditioners. Its /device/1 answers the same unused-slot shape the Pattern A
reporter's /device/2 does -- every operational rep empty {} -- but also
reports a populated /energy/consumption/vs/1. Running discovery against the
reporter's own quoted subdevice block reproduces their diagnostics exactly
(21 bound entities, the same six hrefs), and of those 21 the only primary
entity with a non-None value is energy_kwh: a lifetime kWh total was the
sole thing passing discover_partitioned's liveness gate and materializing
the phantom.

A single-split AC has one compressor and one energy meter, so a
whole-appliance running total appearing under a second index is the
appliance's own bookkeeping, not evidence that hardware is installed at that
slot. Exclude cumulative meters (HA's total/total_increasing state classes,
plus the energy/water/gas device classes for the descriptors that
deliberately declare no state class) from the gate. The gate never applies
to MAIN, and across the whole fixture corpus every device has at least one
non-meter live primary, so no existing device's entities change -- verified
by the golden for the new fixture being identical to the plain KRAC one.

Also implement async_remove_config_entry_device. A subdevice's HA device
outlives the discovery that created it, so a phantom materialized by an
earlier release stays in the registry with no way to delete it from the UI
-- which is the state the second reporter on that issue is in, with a
refrigerator whose diagnostics now report no subdevices at all. Devices the
entry currently provides still refuse removal. No automatic pruning:
enumeration is one-shot and a real sibling can miss a poll (issue #205 on
the reference hardware), so auto-removal would discard a live subdevice's
name, area and automations on a transient miss.

The new fixture's /device/1 seed is the reporter's verbatim capture; its
master half comes from the corpus's other KRAC unit, with the deviations
spelled out in seeds_note.

Claude-Session: https://claude.ai/code/session_01HzUMLnSWBT64o4BQkVEzXp
2026-07-30 18:23:47 +00:00
Marc Billow ca27bf7f6e docs: de-identify reporter usernames repo-wide, add PII rule to skill
Extended the earlier de-identification (jhkwon19) to the other issue #177
reporter (HJcom), who was named in ~20 spots across coordinator.py,
diagnostics.py, subdevices.py, identity.py, capabilities/airconditioner.py,
a fixture's seeds_note, and several test docstrings/function names. Swapped
all of it for "the reporter"/"the Pattern A reporter", matching the
convention already established for the other reporter.

Added a rule to the adding-device-support skill (end of "Lock it in"):
don't put a reporter's name or GitHub username in code comments,
docstrings, seeds_note, or test/function names -- that prose ships and
sits in git history indefinitely, unlike an issue thread or a
release-notes thank-you. Use "the reporter" / "issue #NNN's reporter" /
a pattern label instead.
2026-07-30 03:06:06 +00:00
Marc Billow ce92d71a92 docs: de-identify the reporter's username in code comments
Comments/docstrings across subdevices.py, coordinator.py, the two fac_bora
fixtures, and their tests named the issue #177/#205 reporter directly.
Swapped to "the reporter"/"the Pattern B reporter" throughout -- no
behavior or test-assertion changes, string content only. HJcom (the
Pattern A reporter) is unaffected.
2026-07-30 02:50:49 +00:00
Marc Billow 8600985a36 review: address Opus findings on the subdevice flat-href fallback
- coordinator: _poll_subdevice_flat_hrefs called sess.pace() outside its
  try block and re-read self._session instead of using the caller's
  already-None-checked reference -- a session closed mid-poll (async_close()
  doesn't hold _session_lock) could crash the whole poll cycle instead of
  just dropping that one sibling. Now takes sess from the caller and guards
  pace() the same as get().
- coordinator: skip flat hrefs already covered by the hot/warm sub-poll
  tiers -- those are refreshed every few seconds by _run_subpolls already,
  so re-fetching them again on the once-per-summary-poll flat pass only adds
  GETs, not freshness. Matters because, unlike the Collection path (always
  one GET), a flat subdevice's summary-poll cost scales with its href count.
- subdevices.py module docstring: corrected an overclaim inherited from PR
  #199 that GET /<uuid>/device/0 had been "confirmed live" on jhkwon19's
  unit. Only an individual /information/vs/0 read was ever actually
  confirmed; the Collection endpoint itself has never been observed to
  answer on any known unit, which is exactly what issue #205 exposes.
- SKILL.md: fixed the numofsubdevice cross-check formula to match what
  coordinator.py actually compares (len(materialized) + 1, not
  len(subdevices) + len(subdevices_skipped)).
- Documented, not yet guarded against: a firmware that echoes state back
  under any unrecognized prefix instead of 4.04ing could pass the flat probe
  and the liveness gate, materializing a phantom duplicate of the master.
  Every board seen so far genuinely 4.04s on paths it doesn't own.
- Added test coverage the review flagged as missing: a materialized (not
  just skipped) flat subdevice re-polling end-to-end through to
  canonical_resources, the hot/warm skip itself, zero-master-hrefs and
  two-UUID no-cross-contamination edge cases, and a golden file for the
  #205 fixture (SKILL.md's "fixture + golden + test" discipline).
2026-07-30 02:44:26 +00:00
Marc Billow e78d941af3 fix(subdevices): fall back to per-href probing when a prefixed subdevice has no /device/0 Collection
Issue #205 shows the UUID-prefixed pattern's own reference device
(TP2X_FAC_BORA_21K) doesn't always answer /<uuid>/device/0, contrary to
what the pattern was built against. When that Collection GET comes back
empty, enumerate_subdevices now probes every href the master itself
answered this cycle individually under the UUID prefix, keeping whichever
ones respond. Subdevice gains a flat_hrefs field for this, and the
coordinator re-polls those hrefs individually each cycle instead of
re-fetching a Collection batch that doesn't exist.

Built a fixture from the reporter's real #205 diagnostics dump: the
fallback finds a candidate through the one href already confirmed live
under this UUID (/information/vs/0, from the #177 thread), and
discover_partitioned's liveness gate correctly holds it back since that
href alone binds no entity -- honest current state, not a guessed
resolution.
2026-07-30 02:25:26 +00:00
Marc Billow fb2d267632 fix(water_purifier): route AILITE_DA-REF-WATERPURIFIER boards correctly (#196)
The AILITE water-purifier board (RWP70F15ANW) spells its modelNum
'...-REF-WATERPURIFIER-...', so the board-token scan hit the bare 'REF'
token before ever reaching 'WATERPURIFIER' and misrouted the device to
the refrigerator registry, whose resource surface shares almost nothing
with a water purifier -- hence the incomplete-coverage warning. Add a
documented carve-out for this one token co-occurrence and a matching
TestBoardTokenAmbiguity exception.

Also bind the water-purifier hrefs this board additionally exposes:
cup-detection status, the settings/sound/{mode,output,volume} trio (read
live, since this board's own supportedModes vocabulary differs from both
laundry's and air_purifier's hardcoded/live sets), and last-pour
statistics.

Separately, gate hot_water_temperature off when the device doesn't report
a supportedHotTemperatures list (only a hotwaterRange/hotwaterLevel pair
with no confirmed write contract) -- previously an empty options list
plus a live current value rendered as 'unknown' in HA, the second bug
reported in #196. The existing water_purifier_coffee fixture (#107) turns
out to hit the same shape, so its golden drops the entity too.

Issue #195 (TP1X_REF_21K) needed no change: its diagnostics show zero
unbound hrefs and the model already routes to the refrigerator registry,
matching the maintainer's own comment on the issue.
2026-07-29 23:23:56 +00:00
Marc Billow 9e85395b44 rename: unit/sub-unit -> subdevice, matching OCF terminology
"Unit"/"sub-unit" from #199's multi-indoor-device support wasn't OCF
idiomatic -- OCF calls each component of a composite device a
"subdevice" (see subdeviceIdList), so rename SubUnit -> Subdevice
throughout: the registry module, coordinator state, BoundEntity's
subdevice field, diagnostics keys (subdevices/subdevices_skipped/
subdevice_probes), entity unique_id prefixes (unit1_/sub_<uuid>_ ->
subdevice1_/subdevice_<uuid>_), device-name fallback labels, golden
fixtures, tests, README, and the adding-device-support skill.

Breaking change to entity unique_ids and diagnostics keys, acceptable
since this hasn't been released yet.
2026-07-29 22:57:11 +00:00
Marc Billow 9442248c20 Merge origin/main into multi-device sub-unit support
Conflict was purely additive: both sides appended golden-regression
tests at the same point in the file, and each side's last test shared
the single trailing assert block. Kept every test from both sides, each
with its own copy of that assert.

One real semantic merge on top of that. #136 (on main) remodelled the
legacy ARTIK051 board's beep from a buzzer_volume Number to a beep
Switch, and HJcom's ARTIK051_DONGLE_FAC_18K is exactly that board
generation (is_legacy_board -> True), so its golden -- written before
that change existed -- still expected buzzer_volume. Regenerated it:
buzzer_volume/unit1_buzzer_volume -> beep/unit1_beep on the master and
the second indoor unit alike, with nothing else moving and still no
unit2_ keys. That is main's intended behavior reaching the sub-unit for
free, which is the point of binding siblings through the same registry.

967 passing. Re-ran the corpus-wide unique_id audit over all 57
fixtures (main added five this branch had never seen): no collisions
within a platform.
2026-07-29 19:40:32 +00:00
Marc Billow c181a8b447 feat(subdevices): support multi-indoor-unit systems (#177)
Samsung 2-in-1 air conditioners put more than one logical indoor unit
behind a single IP and a single DTLS session. Only the unit the config
entry was set up against was ever discovered; the second one -- a whole
physical appliance the user can see in SmartThings -- had no entities at
all. Two reporters turned out to have two different mechanisms:

  ARTIK051_DONGLE_FAC_18K -- indexed siblings. /oic/res registers the
  whole tree discoverable and lists three complete parallel resource
  sets whose trailing path segment is the index (/mode/vs/0, /mode/vs/1,
  ...), on OCF-standard and vendor hrefs alike. /device/0's batch
  carries only the index-0 hrefs, so a sibling is reachable only through
  its own /device/<n> collection.

  TP2X_FAC_BORA_21K -- UUID-prefixed tree. /oic/res hides the appliance
  tree entirely (which is why a direct /device/1 probe returns nothing
  on this board). /subdevices/vs/0 carries subdeviceIdList instead, and
  that UUID appears as a literal href prefix; /<uuid>/information/vs/0
  was confirmed live to return the wall unit's own model and serial
  (TP2X_FAC_BORA_RAC_21K) against the master's TP2X_FAC_BORA_21K.

The detection signals don't overlap on either board, so no
disambiguation is needed -- enumeration checks both and takes what
answers.

Both patterns are the same thing underneath: a logical unit is a seed
collection path to poll plus an href transform between the canonical
href the registry knows and the actual on-the-wire href. That is the
whole abstraction (SubUnit), applied at four boundaries -- discovery,
the coordinator, the adapter, and the platforms. Capabilities, the
registry and the climate composite stay written against canonical hrefs
and are untouched.

Uniqueness comes from a key_prefix inside the flattened state key, so
the master unit's keys are byte-identical to every release before this
and every existing golden file is an unchanged regression guard. Each
sub-unit gets its own device-registry entry linked by via_device and
named from its own /information/vs/<n>, so it lands in its own room
rather than crowding the master's device page.

A sub-unit materializes only when it yields at least one primary
(non-diagnostic) entity with a populated value. That gate is not
decoration: the reporter's /device/2 is an unused slot that SmartThings
shows disabled, yet it answers with a full 14-href batch, and it
flattens to exactly one non-None value -- a diagnostic alarm_code
derived from an empty /alarms/vs/2. Without the entity-category filter
it becomes a phantom third climate card. The rule is deliberately
domain-agnostic rather than a list of HVAC hrefs, so a multi-drum
washer (#19) gets the same treatment with no new curation. Units that
answer but fail the gate are logged and reported in diagnostics, so a
genuinely missing unit stays diagnosable from a dump.

Enumeration fetches things that must not then be treated as appliance
state. A rejected candidate's seed has to be read to evaluate the gate,
but only units that pass are polled again, and StateCache has no
eviction -- so discovery runs before the first cache apply and those
reps are held aside for diagnostics rather than frozen into the cache
forever. /multidevice/vs/0 is probed on every device regardless of
family, so merging it into the resources dict would have reached
discovery on any board whose registry doesn't ignore that href -- only
the air conditioner one does -- raising a spurious coverage-gap repair
for a washer or fridge whose firmware answers it. It is corroborating
metadata (numofsubdevice, confirmed read-only) and now lives beside the
resources rather than in them.

Diagnostics reports each unit separately: top-level `resources` is this
unit's own and only its own, which is what the module docstring and the
adding-device-support skill have always claimed it was, and each
sibling or rejected candidate carries its own reps canonicalized so a
block reads exactly like the master's instead of needing to be
de-indexed by hand.

Fixtures are real captures. The ARTIK051_DONGLE_FAC_18K one is entirely
verbatim, both sibling seeds and the hand-read /multidevice/vs/0
included. The TP2X_FAC_BORA one has a real device0, oic_res and
sub-unit /information/vs/0, with the remainder of that unit's tree
constructed and documented as such in seeds_note; /<uuid>/device/0 is
the one part of that pattern still inferred rather than observed, and
can't be tested through the debug panel because a Collection returns a
list.
2026-07-29 19:14:51 +00:00
Marc Billow bd3ca80d3c review: address Opus code-review findings on this branch
- config_flow: the #192 port-rescue made the "every port refused" fast-fail
  permanently unreachable (PREFERRED_PROBE_PORTS is always non-empty and
  always rescued), so removed the dead branch instead of leaving it as
  misleading dead code. A dead host now fails via the handshake loop's own
  error, which carries the real per-port reason.
- oven._has_option: added the is_stub_rep carve-out cooktop.py's identical
  per-token exists_fn already has on the same kind of href, so a not-yet
  sub-polled /mode/vs/0 doesn't permanently exclude energy_saving/
  cooktop_on_alert before their first real fetch lands.
- airconditioner.ENERGY_METER_LEGACY: build via dataclasses.replace() like
  its ENERGY_METER_GENERIC sibling, instead of hand-copying href/poll_tier
  (which would silently drift if common.ENERGY_METER ever gains a field).
- Fixed two stale comments: is_legacy_board()'s docstring still listed
  Volume among tokens needing legacy-only gating, though 'beep' now applies
  unconditionally across board generations; and common.py's UNIVERSAL
  invariant comment didn't mention that airconditioner also now excludes
  ENERGY_METER from the wholesale bundle.
- #191 (CAC token): added the fixture/golden/capability-test coverage the
  AVT token in the same branch got, including an honestly-documented list
  of the ten hrefs this board generation doesn't cover yet.
- fridge.cooler_temperature_setpoint: dropped the hardcoded "N °C" state
  labels -- the resource's own unit field isn't necessarily Celsius on a
  different model reporting the same href, and the options themselves are
  already read live via options_field, so a static per-value label risked
  asserting the wrong unit for a future device sharing this capability.
- airconditioner._legacy_cumulative_power_kwh: parse with float (matching
  common.wh_to_kwh's own numeric parsing) instead of this module's
  integer-only _int, so a decimal-formatted reading doesn't raise.
- test_config_flow: the port-rescue test bound the real 49154 directly,
  which could collide with an actually-running service on some machine;
  now monkeypatches PREFERRED_PROBE_PORTS to an OS-assigned port instead.
- oven.py: consolidated six byte-for-byte-identical single-token options
  write_fns (lamp/sound/fast_preheat/natural_steam/energy_saving/
  cooktop_on_alert) into one _option_switch_write(prefix) factory.

845 tests passing (up from 841 -- 4 new CAC coverage tests).
2026-07-29 18:04:23 +00:00
Marc Billow 36240b44e6 fix(oven): gate fast_preheat/natural_steam on their own tokens (#183)
Both switches were shipped unconditionally (no exists_fn) as an unverified
guess -- the module docstring already flagged them as "unproven." Every
range/oven fixture in the corpus, including the new issue #183 dump,
reports neither fastpreheat_* nor NaturalSteam_* in /mode/vs/0's options at
all, so both were phantom controls: always read as off, and toggling them
wrote a token the firmware never recognized in the first place. That
matches the reporter's exact complaint ("doesn't appear to do anything").

Also bound two tokens confirmed present on this dump but never modeled at
all: EnergySaving_On (the 120-hour energy-saving standby from the app) and
BurnerOnAlert_Off (cooktop-on alert), following the same single-token
options-merge pattern as the existing lamp/sound/fast_preheat switches.

Child lock, the setpoint mismatch, and the missing cook-start control from
this issue are not code bugs -- see the issue comment for what was verified
and what still needs more information from the reporter.
2026-07-29 13:26:39 +00:00
Marc Billow 487ac748bd fix(airconditioner): model legacy-board beep as a switch, not a volume (#136)
Every ARTIK051_KRAC_18K-generation unit confirmed on hardware (three units
across two reporters) only ever carries Volume_100 or Volume_Mute in
/mode/vs/0's options -- never an intermediate value -- so the existing
buzzer_volume Number (0-100, step 10) modeled a control this firmware
doesn't have. Worse, its write path could never produce the literal
'Mute' token needed to actually turn the beep off, since it only ever
wrote a plain integer string. The 'beep' switch already used on newer
boards is the correct model here too; it's no longer gated off the legacy
board generation, and the Number entity is removed.

The WindFree-preset-not-applying report earlier in this issue self-resolved
per the reporter's own follow-up testing, so no code change was needed for
that part.
2026-07-29 13:16:09 +00:00
Marc Billow b5c5c056f4 feat(fridge): expose discrete cooler temperature setpoint (#186)
RT42DG6630B1FZ is a single-door "cooler only" fridge that reports its
setpoint on /temperature/definite/cooler/vs/0 -- a vendor resource outside
both TEMP_CURRENT_GENERIC's '/temperature/current/' and TEMP_SETPOINT's
'/temperature/desired/' href prefixes, so it was entirely unbound and the
setting stayed app-only. Its supportedList (1/2/3/4/7 °C) isn't a
contiguous range, so this is modeled as a select over the device's own
live options rather than a NumberDesc that would let a user pick an
unsupported value like 5 or 6.
2026-07-29 13:11:07 +00:00
Marc Billow 74f34b91a5 feat(registry): route AVT-WW-TP1-23 air purifier boards (#190)
AVT-WW-TP1-23-AXX500 (AX053B810HGD) reported device_type 'unknown' with
empty oneUiVersion, falling back to common caps. It's the same BESPOKE
Cube Air lineage as A-VTWW-TP2-21-COMMON (issue #151), just with the
'-WW-' delimiter shifted one letter left ('A-VTWW-' -> 'AVT-WW-'), which
splits into an 'AVT'/'WW' token pair the existing whole-token 'VTWW' entry
can't see. Added 'AVT' as its own board token onto the same air_purifier
registry -- the resource surface (wind/strength fan, HEPA filter, air
quality sensors, alarms) already matched with zero unbound hrefs once
routed there, so no new capabilities were needed.
2026-07-29 13:06:36 +00:00
Marc Billow d83733a670 fix(airconditioner): scale legacy ARTIK051 cumulativePower correctly (#193)
ARTIK051_KRAC_18K-generation boards report /energy/consumption/vs/0's
cumulativePower in centiwatt-hours, not the plain Wh every other AC board
family reports -- confirmed against the reporter's own SmartThings-app
reading (raw 117430000 vs. the app's authoritative 1,174.30 kWh is exactly
a /100000 factor, not the shared wh_to_kwh's /1000 alone). Split
common.ENERGY_METER into generic/legacy variants on the airconditioner
registry, discriminated by the existing is_legacy_board() check, so every
other AC family keeps the unmodified shared capability.
2026-07-29 13:04:33 +00:00