The legacy Comode codes resolve through the same dynamic resolver as a real
convenient resource, so Nano lands on the existing 'nano' preset (already
labelled WindFree) rather than on a 'windfree' value of its own -- the new
tests asserted the label instead of the value. 2Step had no catalog entry in
either language and would have surfaced as the raw code.
Also updates the existing five-percent-humidity test, which reached into the
descriptor's field/value_fn directly, to the rep_fn the fallback needs, and
covers the fallback itself.
Fixture is a scrubbed diagnostics dump from the unit the writes and
calibrations were verified on; the issue #136 unit is the same model with a
slightly different token set (no Spi, FilterTime_5460, OutdoorTemp_81), which
the presence gating handles the same way.
Covers the pieces the golden's state_keys can't: that the token entities stay
off newer boards, that an absent token yields no entity, that humidity's zero
reads as unknown, that fan/swing/preset read and write through /airflow/vs/0
and the Comode token, and that a board with /wind/* and /mode/convenient/vs/0
still takes the resource paths.
Refs #136
This board generation predates every AC dump the registry was built from and
differs in three ways, all handled here behind presence checks so no other
family's behaviour changes:
* No /wind/* resources at all. Fan speed and vane direction share a single
/airflow/vs/0 resource, whose speedLevel uses the same 0-4 scale as
_DEVICE_TO_FAN and whose direction uses the same codes as _DEVICE_TO_SWING,
so the existing maps are reused rather than duplicated. The resource reports
no supportedModes, so the full scale is offered.
* No /mode/convenient/vs/0. The convenient-mode preset is a Comode_* token in
/mode/vs/0's options, synthesised into a convenient-shaped rep so the
existing dynamic preset resolver keeps working unchanged. Codes were learned
by driving one unit through its cloud integration and reading the token back
each time: Nano is what the app calls WindFree, plus Quiet/Comfort/2Step/
Speed (Fast Turbo) and Off.
* Several settings that newer boards expose as dedicated resources are options
tokens here: SPI, auto clean, air monitoring, beep volume, Good Sleep,
outdoor temperature and filter time. Writes reuse option_write's single-token
merge, the same mechanism the display light already uses on this href.
Newer families carry some of the same tokens *alongside* dedicated resources
for those settings, so the token entities are gated on this generation's
resource shape (/airflow/vs/0 present, /wind/strength/vs/0 absent -- the same
test the climate entity's fan/swing fallback uses, so the two can never
disagree). Without that gate they duplicated auto clean on TP1X/TP2X boards
and applied a calibration from this board to theirs.
Two calibrations, both from hardware rather than from the token names:
OutdoorTemp is offset by 55 (token 75 against a 20.3 C outdoor thermometer in
the same install, token 74 against a 19.4 C forecast; Fahrenheit fits far
worse), and FilterTime is tenths of an hour (token 1710 while the official
Samsung app displayed "171 hours 0 minutes" for the same unit's filter).
Whether filter time counts up or down is deliberately not claimed: it was seen
rising while the unit ran, which contradicts the app's "remaining" wording.
Humidity now falls back to the plain x.com.samsung.da.humidity field where
fivepercentHumidity is absent, still as one entity rather than two, and 0 reads
as "not measuring" rather than 0% -- on this board the field only carries a
reading (51%, matching the same unit's cloud integration) while Air monitoring
is on, which the unit switches back off by itself after about a minute.
Fan, swing, preset, SPI and beep-volume writes were confirmed by read-back on
hardware. Good Sleep's upper bound is a guess (only 0 has been observed), and
/airflow/0 -- the OCF-standard mirror of the vendor resource -- is ignored
rather than modelled, since air_purifier.py found the opposite reliability
ordering between these two hrefs on its own family.
Refs #136
Room air conditioners on the ARTIK051 board (ARTIK051_KRAC_18K, issue #136)
report no oneUiVersion and carry a '_KRAC_' token in modelNum. The existing
'_RAC_' check can't see it -- the 'K' sits between the underscore and 'RAC' --
and the consumer-prefix fallback only covers washers/dryers/dishwashers, so
these units fell back to 'unknown': 8 of their 19 resources ended up unbound
and the device exposed nothing but a power switch.
Same ARTIK051 board family as the '_TVTL_' air purifier handled just below.